Intraprocedural imaging: Flat panel detectors, rotational angiography, FluoroCT, IVUS, or still the portable C-arm?  Matthew J. Eagleton, MD  Journal.

Slides:



Advertisements
Similar presentations
Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection 
Advertisements

Feasibility of transgastric ultrasonography of the abdominal aorta
Catheter-less angiography for endovascular aortic aneurysm repair: A new application of carbon dioxide as a contrast agent  Enrique Criado, MD, Loay Kabbani,
Larisse K. Lee, MD, Peter L. Faries, MD  Journal of Vascular Surgery 
Endovascular aortic repair of a postdissecting thoracoabdominal aneurysm using intraoperative fusion imaging  Adrien Kaladji, MD, Aurélien Dumenil, PhD,
A novel tool for three-dimensional roadmapping reduces radiation exposure and contrast agent dose in complex endovascular interventions  Lars Stangenberg,
Hemodynamic evaluation using four-dimensional flow magnetic resonance imaging for a patient with multichanneled aortic dissection  Baolei Guo, MD, PhD,
Julio A. Rodriguez, MD, Dawn M
Preloaded guidewires to facilitate endovascular repair of thoracoabdominal aortic aneurysm using a physician-modified branched stent graft  Gustavo S.
Intraprocedural imaging: Thoracic aortography techniques, intravascular ultrasound, and special equipment  Rodney A. White, MD, Carlos E. Donayre, MD,
Three-dimensional spiral computed tomographic angiography: An alternative imaging modality for the abdominal aorta and its branches  Geoffrey D. Rubin,
Surgeon-modified fenestrated-branched stent grafts to treat emergently ruptured and symptomatic complex aortic aneurysms in high-risk patients  Joseph.
Jacques Kpodonu, MD, Venkatesh G. Ramaiah, MD, Edward B. Diethrich, MD 
Daniel F. Leotta, PhD, Benjamin W. Starnes, MD 
Initial experience characterizing a type I endoleak from velocity profiles using time- resolved three-dimensional phase-contrast MRI  Thomas A. Hope, MD,
The use of dynamic volumetric CT angiography (DV-CTA) for the characterization of endoleaks following fenestrated endovascular aortic aneurysm repair.
Toronto PowerWire fenestration technique to access false lumen branches in fenestrated endovascular aneurysm repair for chronic type B dissection  Steffan.
Volume changes in aortic true and false lumen after the “PETTICOAT” procedure for type B aortic dissection  Germano Melissano, MD, Luca Bertoglio, MD,
Feasibility of transgastric ultrasonography of the abdominal aorta
Douglas M. Cavaye, FRACS, William J. French, MD, Rodney A
Preliminary clinical outcome and imaging criterion for endovascular prosthesis development in high-risk patients who have aortoiliac and traumatic arterial.
A single-center experience treating renal malperfusion after aortic dissection with central aortic fenestration and renal artery stenting  Dawn M. Barnes,
Time-resolved magnetic resonance angiography as a noninvasive method to characterize endoleaks: initial results compared with conventional angiography 
Stent graft–induced new entry tear (SINE): Intentional and NOT
True lumen re-entry devices facilitate subintimal angioplasty and stenting of total chronic occlusions: Initial report  Donald L. Jacobs, MD, Raghunandan.
Endovascular aortic aneurysm repair with carbon dioxide-guided angiography in patients with renal insufficiency  Enrique Criado, MD, Gilbert R. Upchurch,
Preoperative assessment of abdominal aortic aneurysm: The value of helical and three- dimensional computed tomography  Mario N. Gomes, MD, William J. Davros,
Lower extremity compartment syndrome after elective percutaneous fenestrated endovascular repair of an abdominal aortic aneurysm  John F. Charitable,
Martijn L. Dijkstra, BA, Matthew J. Eagleton, MD, Roy K
Mark F. Conrad, MD, Robert S. Crawford, MD, Christopher J
Thoracic endovascular aortic repair of aortobronchial fistulas
Thoracic endovascular repair as a safe management strategy for aortobronchial fistulas  Charles J. Bailey, MD, Seth Force, MD, Ross Milner, MD, Karthikeshwar.
Risk factors of incomplete thrombosis in the false lumen after endovascular treatment of extensive acute type B aortic dissection  Yong-Lin Qin, MD, Gang.
Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection 
Late endoleak after endovascular repair of an abdominal aortic aneurysm with multiple proximal extender cuffs  Yehuda G. Wolf, MD, Bradley B. Hill, MD,
Three-dimensional spiral computed tomographic angiography: An alternative imaging modality for the abdominal aorta and its branches  Geoffrey D. Rubin,
Ali Khoynezhad, MD, Irwin Walot, MD, Matthew J
Feasibility and accuracy of fusion imaging during thoracic endovascular aortic repair  Christof Johannes Schulz, Matthias Schmitt, Dittmar Böckler, MD,
Staged hybrid approach using proximal thoracic endovascular aneurysm repair and distal open repair for the treatment of extensive thoracoabdominal aortic.
Computer-aided endovascular aortic repair using fully automated two- and three- dimensional fusion imaging  Giuseppe Panuccio, MD, Giovanni Federico Torsello,
Diseases of the thoracic aorta in women
Vladimir Neychev, MD, PhD, Emilia Krol, MD, Alan Dietzek, MD 
Pegge Halandras, MD, Ross Milner, MD  Journal of Vascular Surgery 
Late complications of thoracic endografts
Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair 
Carbon dioxide digital subtraction angiography as an option for detection of endoleaks in endovascular abdominal aortic aneurysm repair procedure  Eijun.
Endovascular management of an acute type B aortic dissection in a patient with fibromuscular dysplasia  Jeanette H. Man, BS, Abby Rothstein, MD, Parag.
Acute iatrogenic type A aortic dissection following thoracic aortic endografting  Gabriele Piffaretti, MD, Giovanni Mariscalco, MD, PhD, Matteo Tozzi,
Douglas M. Cavaye, FRACS, Rodney A. White, MD, George E
Double-chimney technology for treating secondary type I endoleak after endovascular repair for complicated thoracic aortic dissection  Rui Feng, MD, PhD,
Aortic dissection: Percutaneous management of ischemic complications with endovascular stents and balloon fenestration  Suzanne M. Slonim, MD, Ulf Nyman,
First experience using intraoperative contrast-enhanced ultrasound during endovascular aneurysm repair for infrarenal aortic aneurysms  Reinhard Kopp,
Anthony Carnicelli, BA, Adam Doyle, MD, Michael Singh, MD 
Treatment of an early type II endoleak causing hemorrhage after endovascular aneurysm repair for ruptured abdominal aortic aneurysm  Olivier Hartung,
Fenestrated and branched endovascular aortic repair for chronic type B aortic dissection with thoracoabdominal aneurysms  Atsushi Kitagawa, MD, Roy K.
Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair 
The first endovascular repair of an acute type A dissection using an endograft designed for the ascending aorta  Matthew J. Metcalfe, MD, MRCS, Alan Karthikesalingam,
Aortic type B dissection with acute expansion of iliac artery aneurysm in previous endovascular repair with iliac branched graft  Raffaele Pulli, MD,
Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair  Yehuda.
Emergent endovascular stent-graft placement to treat ruptured Stanford type B acute aortic dissection  Saori Kawamura, MD, Hiroshi Nishimaki, MD, PhD,
Relationship between preoperative patency of the inferior mesenteric artery and subsequent occurrence of type II endoleak in patients undergoing endovascular.
Balloon expandable stents facilitate right renal artery reconstruction during complex open aortic aneurysm repair  Rajendra Patel, MD, Mark F. Conrad,
Type B aortic dissection after endovascular abdominal aortic aneurysm repair causing endograft collapse and severe malperfusion  Vikram Iyer, MD, Mark.
Sukgu M. Han, MD, Warren J. Gasper, MD, Timothy A.M. Chuter, MD 
John L. Anderson, Donald J. Adam, MD, Michael Berce, David E. Hartley 
A novel percutaneous double-lumen stent graft technique for treatment of chronic type B aortic dissection under local anesthesia  Sophie Wang, BS, Mahmoud.
Endovascular repair of a type B aortic dissection with a ventricular septal defect occluder  Guangqi Chang, MD, Huishen Wang, MD, Wei Chen, MD, Chen Yao,
Endovascular longitudinal fenestration and stent graft placement for treatment of aneurysms developing after chronic type B aortic dissection  Neal R.
Endoleaks after endovascular repair of thoracic aortic aneurysms
Percutaneous fenestrated endovascular aortic graft treatment of aortocaval fistula with aortic pseudoaneurysms secondary to penetrating trauma  Sheila.
Presentation transcript:

Intraprocedural imaging: Flat panel detectors, rotational angiography, FluoroCT, IVUS, or still the portable C-arm?  Matthew J. Eagleton, MD  Journal of Vascular Surgery  Volume 52, Issue 4, Pages 50S-59S (October 2010) DOI: 10.1016/j.jvs.2010.06.144 Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig 1 Schematic representation of the image intensifier. Journal of Vascular Surgery 2010 52, 50S-59SDOI: (10.1016/j.jvs.2010.06.144) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig 2 Representation of the effects of spatial distortion with conventional image intensifier (II) system. The image becomes “pin-cushioned.” Note in (A) how the grid has lines that are all parallel/perpendicular to each other. Alternatively, (B) the spatial distortion causes the lines further from the center of the image to become curved, like a pin cushion. Similar distortion is visualized with a conventional II system. Journal of Vascular Surgery 2010 52, 50S-59SDOI: (10.1016/j.jvs.2010.06.144) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig 3 Schematic representation of a flat panel detector. Journal of Vascular Surgery 2010 52, 50S-59SDOI: (10.1016/j.jvs.2010.06.144) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig 4 Photographs demonstrating (A) a characteristic portable C-arm, (B) a conventional II-television monitor system, and (C) a flat panel detector-based imaging system. Journal of Vascular Surgery 2010 52, 50S-59SDOI: (10.1016/j.jvs.2010.06.144) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig 5 Intra-operative DynaCT images obtained following endovascular repair of a branched/fenestrated aortic aneurysm repair. (A) The images obtained are able to be viewed with and without contrast, and in multiple planes similar to a conventional CT. Similarly, (B) 3D reconstructions can be generated based on the data, and (C) segments of the image can be removed and color added to highlight specific aspects of the image. Journal of Vascular Surgery 2010 52, 50S-59SDOI: (10.1016/j.jvs.2010.06.144) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig 6 Intra-operative fluoroCT performed at the completion of a fenestrated/branched aortic endograft to treat an aortic aneurysm. (A) In one case, a type II endoleak is identified arising from a lumbar artery (arrow). This endoleak was not treated, and on follow-up CT, it had resolved. In another case (B), a type III endoleak (arrow) arising from the junction of the left renal branch and the fenestrated graft was identified. This was not visualized on completion aortography. The junction underwent a balloon angioplasty with resolution of the endoleak. Journal of Vascular Surgery 2010 52, 50S-59SDOI: (10.1016/j.jvs.2010.06.144) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig 7 Images demonstrating the fusion of preoperative MDCT and intra-operative DynaCT. (A) and (B) demonstrate the registration of the preoperative CT (color image) with the intraoperative DynaCT (black and white segment). Registration typically occurs by aligning, in multiple planes, bony landmarks and areas of calcifications within the aorta. Once registered, the preoperative CT image can be displayed on the fluoroscopic monitor (C), or a computer-generated outline of the image can be displayed (D). The fused image will rotate in 3D with movement of the C-arm and alterations in the gantry angle. Alternatively, specific sites can be highlighted on the preoperative CT, such as the origins of the visceral branches as depicted here (E), and only those markings displayed on the fluoroscopy screen (F). As with the entire CT image as described above, the location of these markers will move with repositioning of the C-arm. Journal of Vascular Surgery 2010 52, 50S-59SDOI: (10.1016/j.jvs.2010.06.144) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig 8 Image from intra-operative use of fusion of preoperative CT and with the live fluoroscopic image. There is an overlay of the aortic aneurysm with a catheter traversing the aorta and entering the left renal artery (arrow). The catheter was easily advanced to this location based solely on the fusion of the two images. Note how the wire in the renal artery does not exactly follow the course of the projected path (double arrow) due to displacement of the artery by the wire and catheter. Journal of Vascular Surgery 2010 52, 50S-59SDOI: (10.1016/j.jvs.2010.06.144) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig 9 Images obtained from IVUS during treatment of a patient with an acute aortic dissection. (A) Demonstrates the most proximal aspect of the dissection with evidence of an intramural hematoma and an entry tear (arrow). (B) and (C) demonstrate the more distal aorta with clear evidence of the dissection flap (arrow) and evidence of expansion of the false lumen (FL) and some compression of the true lumen (TL). IVUS can aid in the treatment of this disease by verifying that the wire is traversing the true lumen, identifying sites of entry tears or fenestrations, and demonstrating true lumen expansion after successful exclusion of flow into the false lumen. Journal of Vascular Surgery 2010 52, 50S-59SDOI: (10.1016/j.jvs.2010.06.144) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig 10 The AcuNav probe positioned with the elements as a line to the left, viewing into the left inferior renal artery, as seen on (A) fluoroscopy (arrow) and (B) digital subtraction angiography. (C) Corresponding color Doppler image with AcuNav. The probe is placed close to the aortic wall (arrow). (D) Color Doppler image of the right renal artery with the probe at the opposite wall. Reproduced from Eriksson M-O, Wanahainen A, Nymen R. Intravascular ultrasound with vector phased-array probe (AcuNav) is feasible in endovascular abdominal aortic aneurysm repair. Acta Radiolgica 2009; 50: 870-5. Authorized by the Taylor & Francis Group (http://www.informaworld.com). Journal of Vascular Surgery 2010 52, 50S-59SDOI: (10.1016/j.jvs.2010.06.144) Copyright © 2010 Society for Vascular Surgery Terms and Conditions