Increasing TKN Sample Determinations Through Automation

Slides:



Advertisements
Similar presentations
Analyze Immediately Residual Chlorine. Topics…. Background: Chlorine Chemistry Industrial Application NJAC Regulations Summary.
Advertisements

Analyze Immediately Dissolved Oxygen. Topics of Discussion *Definition & Pointers *Applications:Water Quality & Sewage Treatment *Theory *Partial Pressure.
Welcome Department of Nutrition and Food Hygiene.
Raymond Chang 10th edition Chapter 16
Nutrient Analysis in the Wastewater Laboratory FVOA Mini-Conference 2012 Presenters: Mary Johnson & Connie Potter.
Review of Analytical Methods for Nutrient Parameters focusing on Nitrates An Overview By Michael Jackman Chemistry Expert.
Mentoring Session Technical Assistance Committee Method Modifications.
Understanding colorimetric analysis. In colorimetry, light of a specific wavelength is absorbed by a coloured solution. The concentration of this solution.
Report Generation and Issue
Advanced Biochemistry Lab : Determination of Nitrogen and Crude protein Ms. Nadia Amara.
Nitrogen Analysis A bit of practice. Colorimetric Determination of NH 3 Standard solutions of ammonium hydroxide were prepared of 0.05 mM, 0.1 mM, 0.15.
TESTS ON AMINO ACIDS AND PROTEINS
Quantitative Determination of Protein by the Biuret &Lowery Reactions
Calorimetric Determination of Glucose by the 3,5-dinitrosalicylic acid Method Several reagents have been employed which assay sugars by using their reducing.
DO NOW How can muscle cells maintain (or keep) a high concentration of potassium inside the cell? If a cell increases or decreases in volume, what type.
Spectrophotometric Analysis of Aspirin
S PECTROPHOTOMETRIC A NALYSIS OF A SPIRIN.  Introduction:  A colored complex is formed between aspirin and the iron (III) ion. The intensity of the.
Chapter 4 – Analysing Acids and Bases Week 2, Lesson 1.
Applied Water and Spent water Manual Chapter 14
Warittha (Mint) Palita (Preem) Peeraya (Sui) Punyawee (Earl) Punyathip (Ping) Members:
Food analysis (473 PHG).
Experts in Chem-Feed and Water Treatment Chlorine Chemistry.
COLORIMETRYCOLORIMETRY Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit Note: A printed description of.
Determination of Iron in Water
Determination of Iron in Water
AUTOANALYZER T. Elsarnagawy 22/12/ Elsarnagawy, MASH
Chemistry group: Iuffredo Raffaela Castellone Gennaro Pollio Alessio Tortorella Attila.
Experiment 33: Colorimetric determination of iron
Lecture 7: Digestion of Samples Digestion of water samples with Kjeldhl method for determination of N Destruction and extraction of soil and sludge for.
DETERMINATION OF AN UNKNOWN DIPROTIC ACID THROUGH VOLUMETRIC ANALYSIS
An Introduction to the Spectrophotometer. Meet your Spectrophotometer Meet your spectrophotometer.
The Islamic University of Gaza- Environmental Engineering Department
Free Residual Chlorine Measurement
AP Free Response Questions 2003
Experiment 33 Colorimetric Determination of Iron CHE1181.
Introduction to Chemical Analysis
Experiments in Analytical Chemistry -Spectrophotometric determination of Mn(II) and Cr(III)
Does my food have glucose?
Determination of Protein Content SMK Negeri 13 Bandung.
Brian Cornwell NASA GSFC Wallops Flight Facility, Wallops Island, VA
Determination of TKN by Subtraction using ASTM D and ASTM D
Titration Chapter 21 section 1.
Quantitative tests for proteins
Medical Electronics - K.Srinivasamoorthi
Colorimetric Determination of Iron
Strontium Extraction from Urine Samples
Determination of Total Nitrogen By Kjeldahl’s Method
Determination of Protein Concentration of a Solution
Technical Sales & Support Chemist
Technical Support Chemist
Quantitative tests for proteins
Why we need new Total Nitrogen parameter and methods for CWA reporting
Ammonia Colorimetric Testing by Gas Diffusion on Segmented Flow Analyzers
Temperature vs. Solubility
Reaction Rates.
Chapter 4 – Analysing Acids and Bases
Quantitative tests for proteins
Experiment 4-4: Determination of Glucose in Blood Serum
Elsarnagawy, MASH Autoanalyzer T. Elsarnagawy 22/12/1432.
Titration of Mixtures of Acids Using a Strong Base For two acids to titrate separately, the ka of the stronger one should be at least 104 times greater.
Exp. Iron in Vitamin Tablet
Analysis of an Acid Base Titration Curve the Gran Plot
Automated Methods of Analysis
Quantitative tests for proteins
Quantitative tests for proteins
Determination of Nitrogen By Kjeldahl’s Method
Analysis of an Acid Base Titration Curve the Gran Plot
ANALYSIS OF COMPUNDS B.Sc. Sneha S. Mule Assistant Professor
Urine Analysis Protein. Protein: Urine normally contains a scant amount of protein, which derives both blood and urinary tract itself. Proteins present.
Experiment 1 Analysis of Some Common Anions
Presentation transcript:

Increasing TKN Sample Determinations Through Automation Benjamin Sanchez & Hayden Maccagno Monterey Bay Analytical Services Introduction Equipment Decreasing Run Time Conclusion MBAS Lab had traditionally analyzed TKN by SM-4500 NH3 BCE Kjeldahl Nitrogen. Our existing digestion block only held 20 places, limiting analysis to 16 unknown samples in an 8 hour day. This procedure required a 4-hour digestion time and 4 hours to determine concentration by titration. Automating this analysis and purchasing a new digestion block has allowed MBAS to increase sample output from 16 samples per day to 24 samples per day. Automating TKN has also cut analysis time by 3 hours, which now allows the analysts to focus on other tasks. Two TKN runs per week by SM-4500 NH3 Kjehldahl Nitrogen required 16 hours for 32 unknown samples to be analyzed. Switching methods to EPA 351.2 and using a 40-place Gerhardt Kjeldatherm and OI Analytical FS3700 analyzer reduced overall time for 2 TKN runs per week to 10 hours, while increasing sample output from 32 to 48 samples per week. The pairing of a 40-place digestor and automated analyzer has improved lab efficiency by increasing sample throughput for TKN while reducing labor requirements, freeing up the analyst for other tasks. Solution About the Authors In order to increase sample output and decrease the amount of time spent on the analysis, MBAS switched to EPA Method 351.2, Revision 2.0: Determination of Total Kjeldahl Nitrogen by Semi-Automated Colorimetry. We purchased the Gerhardt Kjeldatherm for digestion, which holds 40 tubes. This allowed analysts to increase sample output from 16 to 24 samples per run. The digestion block is coupled with the OI Analytical FS3700, which automates the analysis after digestion, freeing analyst time. This has improved laboratory productivity by allowing more analyses to be accomplished with less labor. Benjamin Sanchez Laboratory Scientist CWEA Grade I Laboratory Analyst The graph above shows a Kjeldahl run by method EPA 351.2 consisting of calibration standards, quality control samples, matrix spikes, and 24 unknown samples with a total time of approximately 103 minutes. Hayden Maccagno Principal Analyst – Chemistry CWEA Grade II Laboratory Analyst Gerhardt Kjeldatherm 40 Place Block Digestor Gas Diffusion Module for TKN Contact information Monterey Bay Analytical Services 4 Justin Court Suite D Monterey, CA 93940 Telephone: 831-375-6227 info@mbasinc.com bsanchez@mbasinc.com hmaccagno@mbasinc.com Summary of Method 351.2 25mL samples are digested in the presence of sulfuric acid, potassium sulfate, cupric sulfate on the Gerhardt Kjeldatherm block. Step 1 of the digestion heats the samples at 160˚C for 90 minutes. Step 2 ramps the temperature up gradually for 60 minutes to a final temperature of 380˚C, where the samples then digest for 30 minutes. After the digestion cycle is complete, all samples are automatically raised off the digestion block. Once cool, the samples are diluted to 50mL. All digested samples along with calibration and QC standards are vortexed and transferred into 10mL test tubes. Once all samples are in place, the automated analyzer is started, which mixes each sample with a complexing reagent, raising the pH to >11. Ammonia is generated and passes through a gas diffusion membrane, which is then absorbed into a hypochlorite solution to form chloramine. The chloramine reacts with salicylate to form indophenol blue in an amount proportional to the ammonia concentration. Addition of sodium nitroferricyanide intensifies the blue color prior to the sample passing through the photometric detector for measurement at a wavelength of 660nm. References Standard Methods for the Examination of Water and Wastewater, 20th Edition, 1998 O.I. Analytical, a Xylem brand, In-line Gas Diffusion Total Kjeldahl Nitrogen (TKN) and Ammonia, by Gas Diffusion Segmented Flow Analysis (SFA). (Document #40861214). College Station, TX   O'Dell, J. (1993). Determination of Ammonia of Total Kjeldahl by Semi-Automated Colorimetry. Method 351.2. (Revision 2.0). Cincinnati, OH: Inorganic Chemistry Branch, Office of Research and Development, USEPA . TKN determination using peak height takes 2 minutes per sample vs. approximately 6-8 minutes for distillation and titration using method SM-4500 NH3, Kjeldahl Nitrogen. OI Analytical FS3700 Segmented Flow Analyzer, Set Up for TKN by EPA 351.2