Vicente J. Correa-Gomez MD, Guillermo Tapia MD, Oscar Macias Manuel MD, Alejandro Navas Perez MD, Gilberto Islas MD, Tito Ramírez-Luquin MD, Enrique O.

Slides:



Advertisements
Similar presentations
Authors have no financial interest
Advertisements

Anterior Segment OCT Angle and Vault Analysis After Implantable Collamer Lens  Implantation in Patients With High Myopia Arturo Ramirez-Miranda M.D. Alejandro.
Comparison of Endothelial Cell Count by Manual and Automated Methods in Normal Corneas and in Fuchs' Endothelial Dystrophy Somasheila I Murthy, Debarun.
Pooja B. Jamnadas, MD, Peter Russo, OD, William Bonk, Shuchi Patel, MD Loyola University Chicago, Stritch School of Medicine, Department of Ophthalmology,
Comparison of corneal astigmatism measured with 3 devices Mariko Shirayama, M.D, Li Wang, M.D, PhD, Mitchell P. Weikert, M.D, Douglas D. Koch, M.D. Cullen.
Eugene Ng, Arthur B. Cummings, Patrick P. Collins, Alexander V. Goncharov, Diana Bogusevschi, Chris Dainty, Michael C. Mrochen. The authors of this paper.
Long-Term Follow-Up of Toric Intraocular Lens Implantation for Keratoconus Alejandro Navas, MD, MSc, Martha Jaimes, MD, Jesús Cabral, MD, Arturo Ramirez.
Purpose We studied the interdevice agreement of three systems in the different measurements of the corneal and anterior segment biometric parameters. The.
INTRAOPERATIVE FLAP COMPLICATIONS IN LASIK SURGERY PERFORMED BY OPHTHALMOLOGY RESIDENTS IN TRAINING Arturo Gómez-Bastar MD Arturo Ramirez-MirandaMD Lorena.
Anterior Chamber Depth, Iridocorneal Angle Width, and Intraocular Pressure Changes After Phacoemulsification: Narrow vs Open Iridocorneal Angles Huang.
David Zadok MD, Isaac Avni MD
Accelerated Transepithelial CXL for keratoconus in pediatric population Enrique O. Graue-Hernández, Andrew Olivo-Payne, Lucero J Pedro-Aguilar, Arturo.
Dept. of Ophthalmology, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. Outcome after big-bubble deep anterior lamellar keratoplasty.
Comparison of Orbscan and Ultrasound Pachymetry Measurements Faik Orucov, MD, Abraham Solomon, MD,Ziv Caspi, David Landau, MD, Eyal Strassman, MD, and.
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
Correlation Between Corneal Biomechanics and Wavefront Aberrations Alejandro Rivera, MD Private Practice Mexico City The author has no financial interest.
Hong Kong Eye Hospital Ms Frenchy Chiu Dr Victoria Wong IOL master
Seyed Javad Hashemian MD Eye Research Center Rasoul Akram Hospital Tehran University of Medical Sciences No financial interest
Implantable Collamer Lens Complications
Artemis tm II VHF Ultrasound for Sizing the Visian ICL ASCRS 2008 Philip C. Roholt, MD N. Canton, Ohio, USA The author has no proprietary interest in products.
Paul “Butch” Harton, MD Harbin Clinic Eye Center Rome, GA USA ASCRS Boston Poster, 2010 The Author has no financial interest in the subject matter of this.
A Prospective Study Examining Contact Lens Wear, Refractive Error, and Optical Coherence Tomography Retinal Nerve Fiber Layer Measurements Marie Brenner.
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Phoebe D. Lenhart, M.D. 1, Amy K. Hutchinson, M.D. 1, Michael J. Lynn, M.S. 2, Scott R. Lambert M.D. 1 1 Department of Ophthalmology, Emory University,
Khairidzan Mohd Kamal MD
A case of hypermature cataract formation following implantation of a posterior chamber phakic intraocular lens with a central hole The Catholic University.
Endothelial Keratoplasty in Patients With an Anterior Chamber Intraocular Lens: A Montreal Experience Georges M. Durr, MD 1,2 Johanna Choremis, MD, FRCSC.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Partial Coherence Interferometry Failure Rate in a Teaching Hospital Leslie A. Wei 1,2, BA, Nickolaus P. Katsoulakis 2, MD, Theodoros Filippopoulos 3,
Adriana S. Forseto1, MD Walton Nosé1,2, MD
Scheimpflug and OCT analysis of posterior keratoconus
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group The study of the correlations of the optic disc size with Cornal Geometry and Biomechanical.
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
IOL Calculations Based on Partial Biometry in Humanitarian Missions Joseph Schmitz, MD Kimberly Davis, MD, FACS Scott McClatchey, MD The authors have no.
Ultrasound Biomicroscopy Diagnosis of Benign Iris Cysts in Patient Presenting for Implantation of Copolymer Phakic IOL Muhammad Aman-Ullah MD Howard V.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Minimizing Risk in Visian ICL Implantation.
COMPARISON AND EVALUATION OF OCULAR BIOMETRY USING A NEW NON-CONTACT OPTICAL LOW COHERENCE REFLECTOMETER David Goldblum 1,3, Kaspar Rohrer 1, Rudolf Waelti.
Simulated Experiments on IOL Power Calculation Using Anterior Segment OCT Dong Hyun Jo, M.D., 1,2 Mee Kum Kim, M.D., 1,2 Won Ryang Wee, M.D. 1,2 1 Department.
Evaluating Post Laser Refractive Surgery Corneal Thickness Using Artemis-2 Very High Frequency Arc-Scanning Ultrasonography Versus Pentacam * † Sharon.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
CORNEAL ENDOTHELIAL PROFILE AFTER FERRARA RING IMPLANTATION Leonardo Torquetti, MD, PhD Paulo Ferrara, MD, PhD Paulo Ferrara Eye Clinic Belo Horizonte.
Intraocular Lens Outcomes: Comparison of Technologies and Formulas Carolina Eyecare Physicians, LLC Research Assistant Professor of Ophthalmology Storm.
Instituto para Preservación de la Visión
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
Mumbaieyecarecornealasik.com.
Corneal Pachymetry in Prediction of Refraction After Cataract Surgery
Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation Zina Zhang MD1, Logan.
Comparison of Single-Scheimpflug and Dual-Scheimpflug Pachymetry Measurements and Effect of Decentration World Cornea Congress VI April 7-9, 2010.
Aug 11, 2017 Comparison of predictive accuracy on Partial coherence interferometry (PCI) and swpt-source optical coherence tomographry (SS-OCT) Choun-Ki.
Effect of Axial Length Measurement Method on Refractive Outcomes of Cataract Surgery: Real World Comparison of Partial Coherence Interferometry and Immersion.
Hôpital Ophtalmique Universitaire
Comparison of Central Corneal Thickness measured by
Early Experience with Descemet’s Stripping Automated Endothelial Keratoplasty Combined with Phacoemulsification: Clinical and Refractive Outcome University.
Johnson CH TAN, MBBS, MRCSEd(Ophthalmology)
Mehdi Ghajarnia, MD Mark Mifflin, MD John A. Moran Eye Center
Comparison of corneal powers obtained from four different devices
Eric Dai MD, Pawan Prasher MD, James McCulley MD, R. Wayne Bowman MD.
Comparison of Automated and Manual Measurements of Horizontal Corneal Diameter in Contact Lens Wearers Using Orbscan Eye Metrics Function and Orbscan 11z.
The authors have no financial interest
Associate Professor of Ophthalmology
Roxana Ursea, MD Matthew T. Feng, MD Ovette Villavicencio, PhD
Sun Woong Kim, M.D.1, Hae Jung Sun, M.D.1,
New 3-Dimensional Scheimpflug Analysis of Cataract Density
Bernilla E; Izquierdo Jr. L; Miranda M.
Joshua C. Teichman, MD Richard Lee, MD Andrea Butler, BSc
Khairidzan Mohd Kamal MD
The authors have no financial interest
“Accommodating IOL Implantation Experience”
International Vision Correction Research Centre
Presentation transcript:

Vicente J. Correa-Gomez MD, Guillermo Tapia MD, Oscar Macias Manuel MD, Alejandro Navas Perez MD, Gilberto Islas MD, Tito Ramírez-Luquin MD, Enrique O. Graue-Hernandez MD Anterior Biometry After Phakic Intraocular Lenses. Comparison of 3 Different Technologies: Ultrasound Biomicroscopy, Pentacam HR, and Slit lamp OCT Institute of Ophthalmology “Fundacion Conde de Valenciana” , Mexico City , Mexico. Department of Cornea and External Diseases. Authors have no financial interest.

Introduction Ultrasound Biomicroscopy (UBM) has brought about improvements in viewing the anterior chamber, allowing for a high level of spatial resolution and objective measuring capacity of the anterior chamber structures UBM is a contact exploration technique with an immersion system which requires patients to be in recumbent position. Non-contact imaging technologies like OCT and Pentacam are available to anterior chamber biometry These devices are becoming more popular as they are more comfortable for the patient and decrease the risk of corneal abrasions or infections due to direct corneal contact.

Optical coherence tomography (OCT) is a non-contact high resolution (2 to 20 μm) imaging technology that provides detailed cross-sectional images (tomography) of internal structures. The Pentacam is a Scheimpflug camera based imaging system, which rotates about the eye and collects 50 scans of the anterior chamber in less than 2 seconds.

Purpose To evaluate and compare three different instruments in the biometry of the anterior chamber and after Implantable Collamer Lens (ICL) .

Methods We analyzed 9 eyes from five patients. After surgery values for central anterior chamber depth (ACD), vault, and pachymetry were obtained with ultrasound biomicroscopy , Pentacam HR (Pcam, Oculus) and slit lamp optical coherence tomography (SL-OCT, Heidelberg engineering). Results were analysed by paired T-test , one-way ANOVA, and Pearson correlation coefficient

SL-OCT  PENTACAM  UBM 

Results

Results

Results A ver si le pones barras de error..

Differences in ACD and Vault measured by OCT and Pentacam Vs UBM were statistically significant (p< 0.05). One-way ANOVA revealed that the differences in pachymetry, and anterior chamber depth as measured with AC-OCT and Pcam were statiscally signficant when compared to UBM (p< 0.05). Pearson correlation coefficient was > 0.85 with all tests.

Conclusions Excellent correlation between these 3 instruments was observed. OCT & Pentacam had similar results Vs UBM. The measurements with UBM were smaller in comparison with pentacam and OCT, therefore they offer a range of greater security. However in order to increase the safety of ICL phakic IOL implantation, ACD and vault safety values need to be standardized to each equipment.

References JL Branco, Yan Li, D Huang, MD . Clinical and research applications of anterior segment optical coherence tomography – a review Clin Experiment Ophthalmol. 2009 January ; 37(1): 81–89. Muriël Doors et al. Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation. Graefes Arch Clin Exp Ophthalmol (2009) 247:1139–1146 Lara-Medina et al. Exploration of the anterior segment by optical coherence tomography . Arch Soc Esp Oftalmol. 2006; 81: 647-652 J. Woodmass, G. Rocha. A comparison of Scheimpflug imaging simulated and Holladay equivalent keratometry values with partial coherence interferometry keratometry measurements in phakic eyes. Can J Ophthalmol 2009;44:700–4