Water and Energy management auditor to project manage and provide technical expertise for a range of utility reduction projects - mainly in the Food &

Slides:



Advertisements
Similar presentations
Click to edit Master text styles – Second level Third level – Fourth level » Fifth level Integrated Solutions for Hospitality Projects.
Advertisements

Indoor Water Conservation Presented by Travis Andrews City of Arlington Water Utilities.
Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
Energy Efficient Steam Systems
Energy Efficiency and Conservation Program Overview Taking the heat off the bottom line…
PRESENTERS NDENGA D.L,ASSOCIATED BATTERY MANUFACTURERS,NAIROBI AND KILONZI F.M,MOI UNIVERSITY,ELDORET. APPLICATION OF PINCH TECHNOLOGY IN MINIMISATION.
How It’s Done. Determine where water is being used in the facility Examine and analyze all areas of water use Calculate and account for water use Propose.
ENERGY SURVEYING Please Click through this presentation.
Introduction Build and impact metric data provided by the SGIG recipients convey the type and extent of technology deployment, as well as its effect on.
Heat Exchanger Network Retrofit
Water mass balance Cirencester, 20 October 2009 Carole Bond Envirowise Advisor ADVICE LINE
Preparing for a Water Audit Thomas Pape Technical Advisor, AWE Principal, BMP
CARBERY MILK PRODUCTS BALLINEEN Co. Cork Energy Saving Programme Application of “Pinch” Technology.
Calculating Efficiency Opportunities in Insulation Workgroup Meeting May 2014 Charlie Schreier, PE Engineer.
STEAM TRAPS.
Heat Recovery for Commercial Buildings
1 CE 548 Analysis and Selection of Wastewater Flowrates and Constituent Loading.
Janie Harris, Extension Specialist Housing and Environment.
Plumbing John Arent Architectural Energy Corporation © 2005 CHPS.
MENG 547 LECTURE 3 By Dr. O Phillips Agboola. C OMMERCIAL & INDUSTRIAL BUILDING ENERGY AUDIT Why do we audit Commercial/Industrial buildings Important.
Water Management and Water Audits. WATER MANAGEMENT The basic processes of managing water for human use are: –collection –storage –treatment and, –distribution.
Cleaner Production Assessment (Chapter 4)
Program Name or Ancillary Texteere.energy.gov Process Heating Assessments Michael R. Muller USA Rutgers University, Center for Advanced Energy Systems.
Utility Metering – Saving Energy Dollars and Meeting the Requirements for LEED v4 William Broome – CFM, SFP, LEED GA Brandi Williams – LEED BD+C, FMP,
Lesson 15 Heat Exchangers DESCRIBE the difference in the temperature profiles for counter-flow and parallel flow heat exchangers. DESCRIBE the differences.
Whatever the nature of your business, often simple changes in behaviour or processes can save water and reduce your water bill. These water savings can.
TRP Chapter Chapter 4.2 Waste minimisation.
Energy Audit- a small introduction A presentation by Pune Power Development Pvt. Ltd.
Energy Management Proposed At KTPS. Objectives for Energy Management Generate energy at lowest possible price Manage energy use at highest energy efficiency.
Utility Rebates Services and Funding to Help Build “Green” Restaurants and Hospitality Facilities Tom Coughlin Program Manager.
Slides 9 – Audits Cleaner Production Audit. Slides 9 – Audits CP audit  Knowing where you are and what you have got is the essence of good management.
 Water conservation programs are typically initiated at the local level, by either municipal water utilities or regional governments water utilities 
ISAT Module V: Industrial Systems
Facilities Management and Design Chapter 5 Water and Wastewater systems.
Implementing an Energy Management System Brendan Thorne Aughinish Alumina Limited.
1 By Zenith Energy Services (P) Limited Hyderabad Presentation on Surat Textile Cluster Surat, Gujarat State.
Managing Operational Energy in Buildings
High Efficiency Clothes Washers n Reduce energy costs by 50% per year n Reduce water and sewer costs by 35-50% per year n Use 50% less laundry detergent.
April, 2002Energy Audits1 Heating Degree Days The difference between the base temperature (balance point) and the mean ambient temperature for the day.
Energy Efficiency in Industrial and Commercial Facilities 2003 Energy and Environmental Conference September 16, 2003.
California Urban Water Conservation Council March 1,
Phoenix Convention Center Phoenix, Arizona Federal Water Efficiency Sustainability TrackWater Efficient Operations Kate McMordie Stoughton Pacific Northwest.
NOVO ETS IMPROVING YOUR ORGANIZATIONS’ ENVIRONMENTAL, HEALTH AND SAFETY PERFORMANCE ENERGY MANAGEMENT IN THE CONTEXT OF GREEN PRODUCTIVITY.
LADWP WATER CONSERVATION IEPR Workshop August
Commissioning of New and Existing Buildings Alexander P. Boucher, P.E., CEM, LEED BD+C.
Approaching Water Sustainability through Water/Wastewater Reductions William Fifty and Laura Lokey-Flippo USACHPPM - Surface Water and Wastewater Program.
Kendal at Oberlin Energy Conservation & Sustainability Initiatives.
Week 9 Common Commercial Building energy efficiency measures (Energy Management Opportunities)
Week 6 The Energy Walk Through. Possible elements of a walk through Understand on-site information collection and listing of essential data for collection.
Introduction to Energy Auditing. Major Topics in Introduction to Energy Auditing Course Introduction to energy auditing Residential energy auditing Calculators.
Week 7 Utility Data Analysis. Essential Elements Identify sources for obtaining utility data: paper form, electronically or from the internet Review utility.
Better together... we deliver MODELLING, CONTROL AND OPTIMISATION OF A DUAL CIRCUIT INDUCED DRAFT COOLING WATER SYSTEM February 2016 C.J. Muller Sasol;
Water Efficiency in Buildings Preparations for the Stakeholder and Public consultations Meeting of the Strategic Co-ordination Group Brussels, 8 November.
California Energy Commission Funded Research Project
Energy Auditing – Energy Conservation and Efficiency Measures PRESENTER Mr. A. Hamukale BENG, Meng,MBA,PEEIZ,REng.
Water Audits and Best Management Practice Life Cycle Cost Analyses for Army Medical and Health Care Facilities Presented By: Lisa Raysby Hardcastle, P.E.
1 Workshop “Energy Efficiency management in chemical Industry sector" Thessaloniki, Greece Use of CARE +Tools in Bulgaria energy management.
PROCESS DESIGN DEVELOPMENT
© INTECHNICA Energy efficiency assessment Systematic Approach to Green Production Energy Efficiency Assessment Supported by: The sole responsibility.
Facilities Management and Design Chapter 5 Water and Wastewater systems.
Fort Stanwix National Monument Energy Audit Contract
Seminar On Energy Audit Submitted To: Submitted By:
LEED NC Water Efficiency 5 points Slide Editor: James A
Case sample of a CT option
Industrial Assessment Center Database
Electrical Gas Plumbing Heating & Cooling
Sustainability Assessments - Water
LEED BD+C – Integrative Process
Reducing Water Consumption on StFX Campus Through Water Recycling & Low-Flow Alternatives A Proposal by Megan Fudge, Ross Walker, Andrew Nicholson,
12. Heat Exchangers Chemical engineering 170.
Presentation transcript:

Water and Energy management auditor to project manage and provide technical expertise for a range of utility reduction projects - mainly in the Food & Beverage sectors, along with large commercial buildings

Evaluation of current water use and costs associated with water supply and wastewater discharge Development of a water balance that provides a detailed breakdown of water use by end-use/process Evaluation of efficiency opportunities and identification of life-cycle cost-effective measures Strategic plan for meeting water reduction goals. The objective of water assessment is to develop an understanding of facility water consumption and identify cost-effective water efficiency measures that will help to achieve the sites required water reductions

Water Assessment Phases Historical water consumption analysis Cost data analysis Team coordination 1. Hold a kick-off meeting to state the goals and objectives of the assessment to the facility team 2. Provide interim progress reports on the preliminary findings of the audits 3. Hold a final meeting to present results of the assessment 1. Calculate marginal cost of water and wastewater 2. Verify whether the facility is on proper water and wastewater rate schedules 3. Estimate the potential future water and wastewater rate escalation (to be used in life-cycle cost analysis of efficiency measures). 1. Collect and analyze at least 2 years of data for total supply, wastewater discharge, and all sub-metered water data 2. Estimate system losses based on system condition and age, and document the method used for determining system losses 3. Develop annual distribution curve (water use over time) 4. Develop baselines for both potable water, and industrial, landscaping and agricultural (ILA) use, accounting for consumptive use from both potable and non-potable sources. Document the method used to develop the baseline.

Background data – The facility will provide background information to the assessment team for prioritization of the walk-through audits. This background data includes: 1. Historic water and wastewater bills or data from supply generated and/or treated onsite 2. Sub-metered data on water processes and buildings 3. Building floor space by building type 4. Occupancy data 5. Equipment lists 6. Maintenance schedules 7. Site and individual building maps 8. Distribution system maps

walk-through audits of buildings and applications that were identified in Phase I of the water assessment. The basic documentation requirements for water end-uses are described below: Scope :Only include end-uses and processes that pertain specifically to the site. 1. Domestic plumbing fixtures – Document the following items for toilets, urinals, faucets, and showerheads: Audit approximately 10% of the restrooms at the facility to obtain a gauge on the general age and condition of fixtures 2. Commercial kitchens – Document the following items for ice machines, dishwashing machines, tray conveyor systems, garbage disposals, pre-rinse spray valves, convection steamers, steam kettles and other water consuming appliances: Note the brand and model number of the appliance, measure the flow rate of the appliance if applicable, document the operating schedule of the appliance 3. Irrigation and landscaping : Measure system pressure, Note if there is an irrigation meter, document the operating schedule (noting time of day) and hours per day or week during irrigation season, document the irrigation technology type (make and model of equipment), Estimate the number of sprinkler heads, Identify the overall system condition, noting leaking/maladjusted heads, Identify controls (type of controls and how they are used)

4. Evaporative cooling systems Determine the size of the system (this may be in terms of cooling tonnage or recirculation rate), Determine how many days the system operates per year C. Determine if make-up water is metered. If it is not metered, verify whether system water use is tracked by other means, If possible, walk the system to see if leaks or losses are apparent. For any leaks or losses found, measure and quantify the loss. 5. Closed-loop cooling systems Determine whether system losses are known and measured, If possible, inspect the system piping to see if leaks or losses are apparent. If leaks or losses are found, measure and quantify the loss. 6. Single-pass cooling Determine how many days the system operates monthly or annually, Determine flow rate of system. 7. Steam/boiler systems Determine the size of the system (this may be in terms of steam generation or boiler horsepower), determine how many days the system operates per year, Determine whether the make-up water is metered. If it is not metered, verify if the system water use is tracked by other meansDetermine if cycles of concentration are tracked routinely. If they are not tracked routinely, determine if there are operator logs available that include routine measurement of blowdown and make-up conductivity E. Determine whether the system blowdown is automated or done manually F. Verify that steam traps are operating properly and are leak free G. Determine whether the system returns condensate and where condensate losses may be occurring.

8. Hot water (closed-loop) heating systems Determine if system losses are known and measured If possible, inspect the system piping to see if leaks or losses are apparent. If any leaks or losses are found, measure and quantify the loss Assess domestic hot water heaters for temperature setting and possible leaks. 9. Laboratory and medical facilities – Document the following items for disinfection/sterilization systems, vacuum pumps, water purification systems, photographic and x-ray equipment, glassware washers, vivarium equipment, and other water-using equipment. Note the brand and model number of the equipment, Measure the flow rate of the equipment, if applicable 10. Laundry facilities Determine type of washing machines (note make and model number), Estimate the number of loads washed per day or week, Identify the overall condition of the equipment. 11. Vehicle wash stations Determine the type of wash station, Identify whether the system recycles water. 12. Alternate water sources investigation – Investigate opportunities to access alternate water sources for process on the facility premises to provide a high level recommendation including (but not limited to): [Note a detailed assessment of alternate water sources is outside the scope of a typical facility water assessment.] A. Rainwater harvesting, Grey water, Water reuse, Air conditioning condensate capture, Wastewater reclaim.

Recycled Water, W, recycle Water flow W inlet, T1 Water Flow W outlet, R1 Water Flow W outlet, R2 Water flow W inlet, T3 Water flow W inlet, T2 Total Inflow rate of Water = Total Outflow rate of water + Total Water consumed within the system And for more detailed calculations, component or sub plant usage can be focused on

Investigation and analysis of water efficiency opportunities that include the following elements: 1.Efficiency opportunity assessment – Assess opportunities for water efficiency improvements in each major end-use, including technologies that are detailed above in Phase II of the assessment. Include a consideration for retrofit, replacement, operation and maintenance improvements, and applications for sub-metering 2. Alternate water sources identification – Identify alternate water sources to offset the use of freshwater sources and provide estimated potential of annual water volume, as well as potential applications where the alternate source could be utilized 3. Life-cycle cost analysis – Perform life-cycle cost (LCC) analysis of all measures – the preferred tool for analysis is the Building Life-Cycle Cost (BLCC) analysis program for this analysis activity

1.Water and wastewater costs and other ancillary costs of water-consuming equipment, such as energy, operations and maintenance (O&M), and chemicals 2. Estimated water and wastewater escalation rates 3. Available utility rebates for installed measures, if applicable 4. Prioritization of efficiency opportunities – Rank each measure based on LCC effectiveness and installation cost, addressing both short-term and long-term investment opportunities.

[10/08/2013] Executive summary – Provide a concise overview of the major results of the assessment that includes the following: o Prioritized list of water efficiency opportunities o Baseline water use and method used to determine this value o Water and wastewater rates, marginal costs of water and wastewater, and other associated costs, such as energy o Water distribution curve that provides water use over time showing historic seasonal fluctuations o Water balance shown in graphical form that shows all major water uses by end use and comparison to incoming supply and discharged wastewater that reveals estimated losses of the system. Include general methods used to estimate end-use consumption o Detailed information on efficiency opportunities that include O&M, retrofit, and replacement options for each major water-using piece of equipment, as well as recommendation for sub- metering o Prioritized list of water efficiency opportunities that provides total water, energy, and cost savings and life-cycle cost effectiveness indicator (such as savings to investment ratio or adjusted internal rate of return) o Alternate water sources with estimated potential of annual water volume, as well as potential applications where the alternate source could be utilized o Plan for meeting annual water reduction goals.

The process data is represented as a set of energy flows, or streams, as a function of heat load (kW) against temperature (deg C). These data are combined for all the streams in the plant to give composite curves, one for all hot streams (releasing heat) and one for all cold streams (requiring heat). The point of closest approach between the hot and cold composite curves is the pinch point (or just pinch) with a hot stream pinch temperature and a cold stream pinch temperature. This is where the design is most constrained. Hence, by finding this point and starting the design there, the energy targets can be achieved using heat exchangers to recover heat between hot and cold streams in two separate systems, one for temperatures above pinch temperatures and one for temperatures below pinch temperatures.pinchenergyheat exchangersheat In practice, during the pinch analysis of an existing design, often cross-pinch exchanges of heat are found between a hot stream with its temperature above the pinch and a cold stream below the pinch. Removal of those exchangers by alternative matching makes the process reach its energy target.

Reactor Design calculation Process flow designs, Piping and Instrumentation Drawing (P&ID) Process Control -Feedback Control Systems that minimises waste and enhances process efficiency Automation Systems – linking system and also deals with plant layout Lean Techniques- Calculation of Takt time and value stream mapping

The amount into the system is 150,000m 3 and out of the system is 91,240.46m 3, if this information is fed into the material equation; the amount the system accumulated in the cause of processing the crude oil is 58,759.54m 3. This cannot disappear into the system without been accounted for within an hour. The volume of the Desalter tank was also measured and can take up to 160,000m 3 of crude oil.

The quantity S can be any of the following fundamental quantities Total mass Mass of individual component, in the case of distillation column Total energy Momentum

Hope you enjoy the presentation