XP PLUS Intro High Efficiency Circulating Water Heater

Slides:



Advertisements
Similar presentations
The next generation of VITODENS 200
Advertisements

An Introduction To Marine Steam Propulsion Plant [Source: US Navy]
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
HVAC523 Heat Sources.
VF™ Series Boiler.
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
AC-SSC-1 Installation and operation manual
Installation. Indoor Unit Installation Typical Installation.
 25,000 BTU per Cell  Cell Halves Edge Seams Folded and Crimped. Individual Cells Welded Together to Form Completed Heat Exchanger Assembly.  20 Gauge.
© 2011 Rinnai America Corporation TANKLESS WATER HEATING TECHNOLOGY Commercial Laundry.
Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.
Chapter 9: Water Heating To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Model “BTU” Model “BRT”  20 Gauge aluminized steel tubes  Single orifice (Model “BRT”) or multiple orifice (Model “BTU”) inshot burner  Tubes expanded.
Unit 12 Oil Heat Components
DIVATOP 60 New Wall Hung Gas Fired Boiler. Divatop 60: Main Features Leader in wall hung boilers Ferroli Ferroli, in line with its position as a comfort.
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
Installation. Indoor Unit Installation Typical Installation.
8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.
VENTING AND COMBUSTION AIR
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Mechanical for Oil Heat
Gas Furnace Planned Maintenance
© 2011 Rinnai America Corporation TANKLESS WATER HEATING TECHNOLOGY For Commercial.
High Density Cooling Air conditioning for high density applications
NFPA 31 Standard for the installation of Oil- Burning Equipment
Mestek History Founded in Westfield, MA in 1946 as Sterling Radiator by John E. Reed 4 employees in a rented garage Produced only hydronic finned-tube.
Air Handler Terminology
7.3.5 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Function and Characteristics of Draft Fans & Controls High efficiency.
Heat Exchange Ventilation Heat Exchange Ventilation.
CMS FPIX Cooling System Studies Joe Howell, Fermilab for the FPIX Upgrade Mechanical Working Group CMS Upgrade Workshop April 27,
Product Introduction January 2009
©2005 Armstrong International, Inc. Stainless Steel Sump Ejector.
HEAT-GENERATING EQUIPMENT INTRODUCTION SELECTION EFFICIENCY FURNACES BOILERS CENTRAL HVAC SYSTEMS.
4.0 Equipment Installation Aspects (Section 4.5 On-Rate for Fuel-Fired Equipment)
OUR AREAS OF EXPERTISE Replacement of any coil – regardless of age, make or construction Expert system and coil failure analysis Combination production.
FUTURA PICUS BOILER FOR PELLETS. Features: - Possibility of combustion of pellets and after removing burner wood (wet max.25%) - Mechanical fuel feeding.
Welcome to Baity's Inc! HVAC, Heating Repairs, Cooling Services and Air Conditioning & Heating - Winston-Salem NC Baity's Inc.
Coffee Dispenser Specifications and Installation Requirements.
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES.
The GranView Fireplace
Maturing and cold smoking
Chicago Pneumatic Compressors Company Presentation
Automotive Heating And Air Conditioning
Unit 13 Oil-Burning Equipment
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Special-Purpose Outlets— Electric Heating, Air Conditioning
PHOTO GALLERY Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 7th edition by Yunus A. Çengel and Michael A. Boles.
System Diagrams Symbol Library – Black Background David Sellers
CORAYVAC® Design and Layout
Designing DOT Exchange and Stationary Cylinder Installations
5. Outdoor unit Installation
GEYSER Heat Pump Water Heater
TheEnergyChallenge.org/Week
Presented By: Jim Lombardo Herbert & Conway, Inc.
Course PEF3006 Process Control Fall 2017 Actuators By Finn Haugen
DOMESTIC HEATING DESIGN PRINCIPLES
DC Inverter Air-cooled Chiller Aqua Tempo Super II Series
Electrical Gas Plumbing Heating & Cooling
Heat-Timer Control Options
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
Hot water Systems Heaters.
Roof Top Unit Overview (MAGNUM)
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
S8910U1000 Universal Electronic Ignition Modules Training Module
VR8345 Universal Electronic Ignition Gas Valve Training Module
Lineup (ATW) <2018> <2019> : New series Series Ref. Split
Presentation transcript:

XP PLUS Intro High Efficiency Circulating Water Heater

New XP PLUS New design high input models Replaces existing McBee large XWH models Inputs 1.25M to 4M, our largest Matches with storage tank Industrial and large commercial applications

Comparison

Circulating Water Heater Line   Model Family HW Burkay Genesis VF XP XPPLUS Design Non-Condensing Condensing BTU/HR Range 120K-670K 399K-2.1M 500K-2M 150K - 800K 1.25M – 4.0M Modulation None Staged Fired 4:1 5:1 Heat Exchanger Copper Fin Tube Stainless Steel

XP PLUS Dimensions PWH-1250NP 34" 51-1/2" 49" PWH-1500NP 52-3/4" UNIT WIDTH HEIGHT DEPTH PWH-1250NP 34" 51-1/2" 49" PWH-1500NP 52-3/4" PWH-2000NP 65-1/2" PWH-3000NP 48-1/4" 67-1/4" 79-3/4" PWH-4000NP 96"

XP PLUS Clearances

XP PLUS Heat Exchanger Heat Exchanger 5:1 Turndown Combustion System Heavy-Duty 316L Stainless Steel Heat Exchanger Rail Mounted Door for Excellent Serviceability 5-Year Non-Prorated Warranty Here is an image of the new large input heat exchanger. First, the burner is the key component in the combustion system that operates on a 5:1 turndown. The radial burner is 411 stainless steel and designed exclusively for this high quality heat exchanger. The heavy duty heat exchanger is 316L Stainless Steel. It is a water tube design meaning with put the water inside the tubes which is key for flow control and lime scale free operation. I cannot impress upon you how substantial this heat exchanger is. The door (into which the burner is mounted) is cut from 1-1/2 inch think stainless steel. It is so heavy that the door is mounted on a rail that allows us to pull the door back and turn it on a hinge for service access. A heat exchanger this strong deserves nothing less than a five year non-prorated warranty.

XP PLUS Vent Sizes and Lengths

XP PLUS Vent Materials PVC/CPVC

XP PLUS Vent Materials Polypropylene

XP PLUS Vent Materials Stainless Steel

XP PLUS Direct Vent Options

XP PLUS Venting Options – Room Air

XP PLUS Venting Options – Common Vent

XP PLUS Outdoor Applications

XP PLUS Combustion Air Filter Models PWH1.25 PWH1.5 PWH2.0 Filter Size - 16 x 20 x 1 PWH3.0 PWH4.0 Filter Size - 24 x 30 x 1

XP PLUS Water Chemistry & Pump Info Piping XP PLUS Water Chemistry & Pump Info Water Chemistry Water chemistry is very important. With this vital information found in our installation manuals, you can make important decisions. The forced circulation design of the water tube can deliver lime scale free operation. Logically though, the customer can have spectacularly hard water that would be damaging to any water heater. This information tells us what we need and how to operation the water heater based on typical water chemistry. If the water chemistry is outside the range of 5-15 grains, then action would need to be taken to bring the water into proportional quality.

XP PLUS Water Piping 2 ½” water connections for 1250-2000 models Connections are made with Victaulic adapters

XP PLUS Piping – Single Unit Weight support of circulating pump may be needed

XP PLUS Piping – Multiple Units Standard Pump Upsized Pump

XP PLUS Electrical Requirements For 1250 & 1500 models connect 120V electrical supply For 2000 & 3000 models connect 208V 3 phase electrical supply For 4000 models connect 480V 3 phase electrical supply Model Unit Amp Draw Pump Amp Draw 1250 9.9 11.2 1500 7.8 2000 1.3 9.6 3000 2 13.4 4000 2.3 6.1

XP PLUS Wiring 1250- 1500 Models 120V 1ph 1HP 115V 1ph G L N * Relay (Field Supplied) *Service switches recommended (Not illustrated) 1HP 115V 1ph *Ground Not Illustrated 120V 1ph

XP PLUS Wiring 2000 & 3000 Models Wiring 208V 3ph G L1 L2 L3 N *Definite Purpose Contactor/ Relay (Field Supplied) *Service switches recommended (Not illustrated)

XP PLUS Wiring 4000 Model 480V 3ph G L1 L2 L3 N *Definite Purpose Contactor/ Relay (Field Supplied) *Service switches recommended (Not illustrated)

XP PLUS Wiring – Low Voltage Connections

XP PLUS Gas Supply Requirements Gas lines sized per the National Fuel Gas Code Natural gas requirements are 14” w.c. maximum to 4” w.c. minimum Propane gas requirements are 14” w.c. maximum to 8” w.c minimum Unit Inlet Connection Size 1250 1 ½” 1500 2000 3000 2” 4000 2 ½”

XP PLUS Gas Supply Piping

XP PLUS LP Gas Conversion Units may be converted to propane with the addition of a propane orifice and an air orifice plate for 3000 & 4000 models. Kits available

XP PLUS LP Gas Conversion

XP PLUS Condensate Removal

XP PLUS Controls Controls Built-In Cascading Sequencer for up to 8 Water Heaters Leader Member 1 Member 2 Member 3 Member 4 Member 5 Member 6 Member 7 Cascade Sequencing will allow up to eight water heaters to communicate and work together as a team. One water heater is assigned as the Leader. The Leader can be daisy-chained together with up to seven “Member” water heaters. The Leader will guide the Member water heaters to deliver the most efficiency operation of multiple units. This is a valuable feature for large commercial applications where multiple water heaters are the norm. Extra note, each day the Leader water heater will assign “First ON” to a different water heater. This rotation of “First ON” puts equal use on the appliances over the course of the season.

XP PLUS Controls Display 8” Touch screen display

Questions?