Module 4: Technical Requirements for Prefabricated Buildings – Alberta

Slides:



Advertisements
Similar presentations
2009 IRC Bracing Provisions
Advertisements

Chp12- Footings.
Lecture 9 - Flexure June 20, 2003 CVEN 444.
Residential Foundations © 2010 Project Lead The Way, Inc.Civil Engineering and Architecture He who has not first laid his foundations may be able with.
Loads and Load Paths "Architecture is inhabited sculpture."
Building Code – Flashing Changes & Challenges Builder Breakfast and Luncheon Series Presented by:
Building Enclosure Moisture Management Institute (BEMMI)
INTRODUCTION TO THE NEW SUBPART R Prepared by the U.S. Department of Labor, OSHA Office of Construction Standards and Compliance Assistance.
NGfL CYMRU GCaD STRUCTURAL TIMBER FRAMING.
PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC.
Chapter 33 Foundation Systems.
Foundation Systems.
Chapter 19 Floors.
Floor Systems and Foundation Support
Bridge Engineering (4) Foundations – Caisson Foundations 1. *Caisson foundations 1.1 IntroductionIntroduction A caisson is basically a structure.
Commercial Foundations
Architectural Design Construction of a Wall Section Upon completion of this assignment, you will be able to accurately and neatly draw, to scale and limits,
Roof Terms Span –Distance across the building. Roof Terms Run –1/2 the distance across the building (1/2 span distance)
Reading Structural Drawings
DRAWING ON EXPERIENCE … BUILDING ON STRENGTH Six Storey Wood-Framed Buildings Unique Structural Opportunities & Challenges Kurt Ruhland, P.Eng. Director,
CAISSON FOUNDATION.
Foundations. Definition of Foundation The supporting portion of a structure located below the structure and supported only by soil or rock. The purpose.
+ Sill and Floor Construction Vocabulary. + Anchor Bolt A threaded rod inserted in masonry construction to anchor the sill plate to the foundation.
Chapter 44 Building Codes and Commercial Design. 2 Links for Chapter 44 Building Codes Design Categories Using the Codes Related Web Sites.
Engineering Analysis of NFPA 285 Tested Assemblies
Chapter 28 Structural Components of Framed Construction.
FRAMING SEMINARS 2012 PRESENTED BY KW ENGINEERING 1.
Topic 11: Timber Subfloor - Advanced
Sprinkler Loads on Trusses
Building Regulations & The Building Control System 4A7 Design & the Built Environment John O’Connor.
House Construction.
BUILDING CONSTRUCTION
UNIT 5 BRICK MASONRY.
Floor Framing.
Structural Loads.
Learning Outcome Lesson Objective
CAISSON FOUNDATION.
Leads Institute of Technology & Engineering
BOMBA BRIEFING QUESTIONAIRE FOR 30 AUGUST 2017
Review of Indian Seismic Codes
The Engineering of Foundations
Chapter 3 Loads on Buildings.
Bottom Chord Live Load Concurrency and Truss Design
APPLICATIONS OF TECHNOLOGY
Use of Cantilevered Sill Plates with MPCWT to Align with Varying Thicknesses of Exterior Sheathing Overview Revised 3/22/2017.
Prepared by John R. Henry, P.E. Senior Staff Engineer
Educational Overview Revised 6/13/2017
Wood structures Topic 3 Floor Framing
Wood Structures Topic 8 Quality Workmanship
Module 6: Confirming Compliance
Residential Foundations
Residential Foundations
Prepared for Municipal Officials in the Prairie Provinces March 2018
Engineering Project Cable Management.
INFORMATION ABOUT: EUROPEAN FIRE CLASSIFICATION.
Building Construction
Module 5: Facilitating Compliance with Prefabrication
Building Construction I Sofia Sebastian 1
STRUCTURAL TIMBER FRAMING
Component or parts of a building
Prepared for Municipal Officials in the Prairie Provinces March 2018
Module 3: The Factory-Constructed Building Industry
Water-Resistive Barriers: Assuring Consistent Assembly Water Penetration Resistance Educational Overview Revised August 31, 2018.
Prepared for Municipal Officials in the Prairie Provinces March 2018
Module 7: Challenges – Saskatchewan
Module 2: Factory-Constructed Buildings – Then and Now
Prepared for Municipal Officials in the Prairie Provinces March 2018
© OnCourse Learning.
Module 7: Challenges – Manitoba
Chapter 13 Concrete Form Design.
Presentation transcript:

Module 4: Technical Requirements for Prefabricated Buildings – Alberta Factory-Constructed Buildings in Canada – Evolution, Regulatory Requirements and Confirmation of Compliance Module 4: Technical Requirements for Prefabricated Buildings – Alberta Prepared for Municipal Officials in the Prairie Provinces March 2018

Modules Who We Are – CHBA-MOD and MHAPP Prefabricated Buildings Then and Now The Industry Technical Requirements Facilitating Compliance Confirming Compliance Challenges Take-Aways Module 4 – Applicable Technical Requirements Module 4 describes the technical requirements that apply to prefabricated buildings in Alberta 4 -

Technical Requirements National Model Construction Codes NU YK NT NL BC Alberta Module 4 – Technical Requirements Building regulations in Alberta, like building regulations in all the provinces and territories, are based on the national model codes. MB SK QC ON PE NB NS 4 -

Technical Requirements Regulations: Alberta Building Code Alberta Plumbing Code Regulation and Private Sewage Disposal Systems Regulation Alberta Fire Code Module 4 – Technical Requirements The regulations that apply across the province are: Alberta Building Code Alberta Plumbing Code Regulation and Private Sewage Disposal Systems Regulation Alberta Fire Code 4 -

Technical Requirements Regulations - Provincial: Alberta Building Code Alberta Plumbing Code Regulation and Private Sewage Disposal Systems Regulation Alberta Fire Code Module 4 – Technical Requirements This discussion of requirements that apply to factory-constructed buildings focuses on the Alberta Building Code. 4 -

Technical Requirements Current Alberta Building Code (ABC) 2014 is based on the 2010 NBC with a few variations; e.g., limits on cladding permitted on balconies on buildings with stacked dwelling units to provide additional fire protection Part 10 addressing relocatable industrial accommodation (not in the NBC) includes exemptions from energy efficiency requirements for the building envelope and fuel-fired warm air furnaces Module 4 – Technical Requirements The Alberta Building Code is based on the National Building Code with a few variations such as: requirement for fire resistant cladding at balconies on buildings with stacked dwelling units a separate Part to provide requirements for relocatable industrial accommodation 4 -

Technical Requirements Alberta Building Code (ABC) for factory-constructed buildings – All in-factory and on-site work must comply with the applicable requirements of the ABC Module 4 – Technical Requirements For factory-constructed buildings, all in-factory and on-site work must comply with the applicable requirements of the Code This subject will be discussed in more detail later. …. 4 -

Technical Requirements Current Alberta Building Code (ABC) 2014 does not reference CSA Z240 MH Series “Manufactured Homes” still includes requirements that refer to manufactured homes code change requests have been submitted to delete these Land-Use Bylaws many address manufactured homes see Module 7 Module 4 – Technical Requirements CSA Z240 MH Series, Manufactured Homes Like the NBC, the ABC does not reference CSA Z240 MH Series, Manufactured Homes. That said, they used to be allowed and there are some left-over requirements in the ABC that refer to these. Code change requests have been submitted to delete them. Manufactured homes are also addressed in many land-use bylaws. This is discussed in Module 7. 4 -

Technical Requirements Site Work must comply with the BC Building Code in all cases: siting; e.g., re. spatial separation site preparation [9.12.] footings and foundations [9.15.] service hook-ups other work not completed in the factory for multi-module buildings “stitching” together to maintain integrity of protection - air barrier, vapour barrier, insulation - weather barrier, cladding, roofing - fire protection Module 4 – Technical Requirements Site Work As noted, all site-work must comply with the BC Building Code. For all prefabricated buildings, this includes: siting; to comply, for example, with the spatial separation requirements site preparation [9.12.] footings and foundations [9.15.] service hook-ups other work not completed in the factory For multi-module buildings, the Alberta Building Code requirements apply to “stitching” the modules together to maintain integrity of the building envelope and fire protection. 4 -

Technical Requirements Foundations for All Prefabricated Buildings all buildings to be installed on “permanent foundations” foundations that comply with Code Part 9 options: perimeter foundations - depth depending on soil type and frost point-support in-ground foundations (piles designed to Part 4) - depth depending on soil type, frost depth point-support surface foundations - limits on application Module 4 – Technical Requirements Foundations Prefabricated buildings must be installed on permanent foundations. The industry considers a permanent foundation to be any foundation that complies with Code. Part 9 offers a number of options: full-perimeter foundations with depth depending on soil type and frost depth point-support in-ground foundations - engineered piles– again with depth depending on soil type and frost depth and point-support surface-foundations with some limitations on use CSA Z240.10.1-16 4 -

Technical Requirements Foundations all buildings to be installed on “permanent foundations” foundations that comply with Code Part 9 options: perimeter foundations - depth depending on soil type and frost point-support in-ground foundations (piles designed to Part 4) - depth depending on soil type, frost depth point-support surface foundations - limits on application CSA Z240.10.1 Site Preparation, Foundation and Installation of Buildings Module 4 – Technical Requirements Foundations This last option is where CSA Z240.10.1 comes into play. CSA Z240.10.1-16 4 -

Technical Requirements Foundations point-support surface foundations permitted where: foundation complies with Z240.10.1 Site Preparation, Foundation and installation of Buildings [referenced in ABC 9.15.1.3.] AND the building is not on frost-susceptible soil [see ABC Table 9.12.2.2.] OR a) has no masonry AND b) passes the deformation resistance test in Z240.2.1 Technical Requirements for Manufactured Homes [see ABC 9.12.2.2.(6) and 9.15.1.3.] Module 4 – Technical Requirements Foundations The Alberta Building Code permits point-support surface-foundations where: the building is detached the foundation complies with Z240.10.1 Site Preparation, Foundation and Anchorage of Manufactured Homes [ref. BCBC 9.15.1.3.] and the building is not on frost-susceptible soil [ref. BCBC Table 9.12.2.2.] OR a) has no masonry AND b) passes the deformation resistance test in Z240.2.1 Technical Requirements for Manufactured Homes [ref. BCBC 9.12.2.2.(6) and 9.15.1.3.] It is easy to confirm whether a building has masonry. Confirming compliance with the deformation resistance test is discussed in Module 6. 4 -

Technical Requirements Anchorage all buildings must be anchored against wind and earthquake loads unless this can be shown to be unnecessary [ref. ABC 9.23.6.1] Part 9 options: embedding floor joists in perimeter foundation [ABC 9.23.6.1.(2)(a)] anchoring sill plate to perimeter foundation [ABC 9.23.6.1.(2)(b)] anchoring in compliance with Z240.10.1 Site Preparation, Foundation and Installation of Buildings [ABC 9.23.6.3.] where the building is not more than 4.3 m wide (14’) 1 storey in building height Module 4 – Technical Requirements Anchorage Similarly, all prefabricated buildings must be anchored in accordance with the Alberta Building Code unless this can be shown to be unnecessary. Part 9 provides three options: embedding floor joists in a perimeter foundation [ABC 9.23.6.1.(2)(a)] anchoring sill plate to a perimeter foundation [ABC 9.23.6.1.(2)(b)] anchoring in compliance with Z240.10.1 Site Preparation, Foundation and Anchorage of manufactured Homes [ABC 9.23.6.3.] where the building is not more than 4.3 m wide (14’)- 1 storey in building height 4 2

Technical Requirements Anchorage Z240.10.1 Site Preparation, Foundation and Installation of Buildings [ABC 9.23.6.3.] where anchorage is required depending on resistance to overturning and pier toppling due to wind minimum pull-out resistance determined by engineering OR two deemed to comply solutions minimum installation depth maximum spacing where means of adjustment is required Module 4 – Technical Requirements Anchorage Z240.10.1 specifies where anchorage is required minimum pull-out resistance - which must be determined by engineering OR - by using one of two deemed to comply solutions minimum depth maximum spacing where means to adjust the length of the anchors is required 4 2

Technical Requirements Z240.10.1-16 Site Preparation, Foundation and Installation of Buildings Application site preparation and skirting apply to all buildings on surface foundations stitching applies to all multi-module buildings foundation requirements apply where – - the building is 1 storey - no masonry, heavy roofing, or concrete floor topping - uniformly distributed live floor load ≤ 2.4 kPa (limits to application of anchorage requirements are specified in the ABC) Module 4 – Technical Requirements Z240.10.1 – Updates - Application A new edition of Z240.10.1 was published in 2016 titled Site Preparation, Foundation and Installation of Buildings to better reflect the scope and application of the standard. The applications of various sets of requirements are more clearly and accurately stated: site preparation and skirting apply to all buildings on surface foundations stitching applies to all multi-module buildings foundation requirements apply where – - the building is 1 storey - there is no masonry, heavy roofing*, or concrete floor topping and - the uniformly distributed live floor load does not exceed 2.4 kPa the limits to the application of the anchorage requirements are specified in the building code as described previously *Heavy roofing includes concrete or clay roof tile 4 2

Technical Requirements Z240.10.1-16 Technical new Tables for minimum pier footing areas for buildings weighing not more than 1.9 kg/m2 depending on - - soil bearing pressure - snow load - tributary area supported new calculation and Tables for resistance to overturning due to wind depending on: - building weight - building width - spacing between supporting beams - 1-in-50 hourly wind pressure - updated wind exposure factors consistent with NBC Part 4 Module 4 – Technical Requirements Z240.10.1 – Updates - Technical Notable technical updates include: new Tables for minimum pier footing areas for buildings weighing not more than 1.9 kg/m2 depending on – - soil bearing pressure - snow load - the tributary area supported a new calculation and Tables for resistance to overturning due to wind to determine if anchorage is needed. The resistance values depend on – - building weight - building width - spacing between supporting beams - 1-in-50 hourly wind pressure and - exposure factors that have been updated consistent with Part 4 of the National Building Code. These up-dates should give building officials even more confidence in accepting surface foundations and anchorage that complies with the standard. 4 2