Fracture strength testing of crowns made of CAD/CAM composite resins

Slides:



Advertisements
Similar presentations
IPS e.max CAD Lithium Disilicate Study
Advertisements

Date of download: 5/31/2016 Copyright © ASME. All rights reserved. From: Fatigue Limit Prediction of the Matrix of 17-4PH Stainless Steel Based on Small.
Figure 1. (a, b) Preparation design of nano-composite CAD/CAM restorations. (a) full crown and (b) mesio-occluso-distal inlay with a cusp capping; (c,
Microbial colonization at the implant-abutment interface and its possible influence on periimplantitis: A systematic review and meta-analysis  Marco Tallarico,
The Glossary of Prosthodontic Terms
Chairside CAD/CAM materials. Part 2: Flexural strength testing
Clinical marginal and internal gaps of zirconia all-ceramic crowns
Clinical application of removable partial dentures using thermoplastic resin. Part II: Material properties and clinical features of non-metal clasp dentures 
Abdulaziz Alsahhaf, BDS, Wael Att, DDS, Dr Med Dent, PhD 
Early in contrast to recent methods to evaluate masticatory function in implant patients  Gunnar E. Carlsson, LDS, Odont Dr/PhD, Dr Odont hc, Dr Dent hc,
The effect of two marginal designs (chamfer and shoulder) on the fracture resistance of all ceramic restorations, Inceram: An in vitro study  Ezatollah.
Multiparticle Adhesive Dynamics
Micro-shear bond strength of different resin cements to ceramic/glass-polymer CAD- CAM block materials  Isil Cekic-Nagas, DDS, PhD, Gulfem Ergun, DDS,
Zahid Iqbal, BDS, FCPS, Muhammad Sohail Zafar, BDS, MSc, PhD 
Tariq F. Alghazzawi, BDS, MS, MSMtE, PhD 
Adhesion procedure for CAD/CAM resin crown bonding: Reduction of bond strengths due to artificial saliva contamination  Asuka Kawaguchi-Uemura, Atsushi.
A double blind randomized clinical trial comparing lingualized and fully bilateral balanced posterior occlusion for conventional complete dentures  Yasuhiko.
Madoka Suzuki, Hideaki Fujita, Shin’ichi Ishiwata  Biophysical Journal 
Date of download: 11/27/2018 Copyright © ASME. All rights reserved.
Current status of zirconia restoration
Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible  Hironari.
All-ceramic inlay-retained fixed dental prostheses for replacing posterior missing teeth: A systematic review  Raquel Castillo-Oyagüe, Rocío Sancho-Esper,
Investigation of accuracy and reproducibility of abutment position by intraoral scanners  Shota Fukazawa, DDS, Chikayuki Odaira, DDS, PhD, Hisatomo Kondo,
Comparison of fracture resistance between cast, CAD/CAM milling, and direct metal laser sintering metal post systems  Mehmet Selim Bilgin, DDS, PhD, Ali.
Mini dental implants retaining mandibular overdentures: A dental practice-based retrospective analysis  Franz Sebastian Schwindling, DDS, Dr. med. dent.,
Extrinsic compression of the external iliac artery following internal fixation of an acetabular fracture  Erin Koelling, MD, Dipankar Mukherjee, MD  Journal.
Effect of short glass fiber/filler particle proportion on flexural and diametral tensile strength of a novel fiber-reinforced composite  Rodrigo Borges.
Bone morphological effects on post-implantation remodeling of maxillary anterior buccal bone: A clinical and biomechanical study  Nobuhiro Yoda, DDS,
A paradigm shift for bone quality in dentistry: A literature review
Evaluating the influence of ambient light on scanning trueness, precision, and time of intra oral scanner  Toshio Arakida, Manabu Kanazawa, Maiko Iwaki,
Agnieszka Tarkowska, Lukasz Katzer, Marcus Oliver Ahlers, Priv. -Doz
Shariq Najeeb, BDS, MSc, Muhammad S
Cross-sectional observational study exploring clinical risk of titanium allergy caused by dental implants  Maki Hosoki, Keisuke Nishigawa, Toyoko Tajima,
Early in contrast to recent methods to evaluate masticatory function in implant patients  Gunnar E. Carlsson, LDS, Odont Dr/PhD, Dr Odont hc, Dr Dent hc,
Influence of buccal cusp reduction when using porcelain laminate veneers in premolars. A comparative study using 3-D finite element analysis  Carlos Marcelo.
Clinical evaluation of a dental color analysis system: The Crystaleye Spectrophotometer®  Chikayuki Odaira, DDS, PhD, Sozo Itoh, DDS, PhD, Kanji Ishibashi,
Bone metabolism of residual ridge beneath the denture base of an RPD observed using NaF-PET/CT  Hanako Suenaga, DDS, PhD, Masayoshi Yokoyama, DDS, PhD,
Effect of surface treatments on the bond strength between resin cement and differently sintered zirconium-oxide ceramics  Murat Yenisey, Doğu Ömür Dede,
Biomechanical analysis of immediately loaded implants according to the “All-on-Four” concept  Satoshi Horita, DDS, Tsutomu Sugiura, DDS, PhD, Kazuhiko.
Ten-year longitudinal study on the state of dentition and subjective masticatory ability in community-dwelling elderly people  Naoko Sato, Takahiro Ono,
Comparison of fracture resistance between cast, CAD/CAM milling, and direct metal laser sintering metal post systems  Mehmet Selim Bilgin, DDS, PhD, Ali.
Microbial colonization at the implant-abutment interface and its possible influence on periimplantitis: A systematic review and meta-analysis  Marco Tallarico,
Strategies for alveolar ridge reconstruction and preservation for implant therapy  Chihiro Masaki, DDS, PhD, Tetsuji Nakamoto, DDS, PhD, Taro Mukaibo,
Effects of a fluoride etchant and a phosphate primer on bonding of veneering composite to Ti–6Al–4V alloy for CAD/CAM restorations  Yohsuke Taira, DDS,
Kenji Fueki, DDS, PhD  Journal of Prosthodontic Research 
Effect of priming agents on shear bond strengths of resin-based luting agents to a translucent zirconia material  Shogo Yagawa, Futoshi Komine, Ryosuke.
Clinical marginal and internal gaps of zirconia all-ceramic crowns
A digital approach for one-step formation of the supra-implant emergence profile with an individualized CAD/CAM healing abutment  Tim Joda, DMD, MSc,
Verification of finite element analysis of fixed partial denture with in vitro electronic strain measurement  Gaoqi Wang, PhD, Song Zhang, PhD, Cuirong.
Current barrier membranes: Titanium mesh and other membranes for guided bone regeneration in dental applications  Yunia Dwi Rakhmatia, DDS, Yasunori Ayukawa,
Effect of veneering materials on fracture loads of implant-supported zirconia molar fixed dental prostheses  Tomohide Kondo, Futoshi Komine, Junichi Honda,
A.C. Dang, M.D., A.P. Warren, M.D., H.T. Kim, M.D., Ph.D. 
Hanako Uesugi, DDS, Hiroshi Shiga, BEng, DDS, PhD 
Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone (PEKK) and zirconia  So-Yeon Bae, PhD, Jin-Young.
H. Sadeghi, D.E.T. Shepherd, D.M. Espino  Osteoarthritis and Cartilage 
Fig. 1. Observation of LAVA surfaces: (A, C, E): top surfaces of sandblasted CAD/CAM blocks; (B, D, F): cross-sectional view; the specimens were sandblasted.
Sleep less and bite more: Sleep disorders associated with occlusal loads during sleep  Takafumi Kato, DDS, PhD, Taihiko Yamaguchi, DDS, PhD, Kazuo Okura,
M. Hufeland, M. Schünke, A.J. Grodzinsky, J. Imgenberg, B. Kurz 
The effect of fatigue loading on the screw joint stability of zirconium abutment  Mitsuyoshi Tsumita, DDS, PhD, Yuji Kokubo, DDS, PhD, Takamitsu Kano,
Fracture resistance of premolars restored with inlay and onlay ceramic restorations and luted with two different agents  Gloria Beatriz de Azevedo Cubas,
Highly producible method for determination of occlusal vertical dimension: relationship between measurement of lip contact position with the closed mouth.
Primer of statistics in dental research: Part II
Primer of statistics in dental research: Part I
The effect of surface treatment on bond strength of layering porcelain and hybrid composite bonded to zirconium dioxide ceramics  Minori Hatta, DDS, PhD,
Biological behavior of fibroblast-like cells cultured on anodized-hydrothermally treated titanium with a nanotopographic surface structure  Shingo Miura,
Cell-based bone regeneration for alveolar ridge augmentation – Cell source, endogenous cell recruitment and immunomodulatory function  Masaru Kaku, DDS,
A fixed movable resin-bonded fixed dental prosthesis – A 16 years clinical report  Michael G. Botelho, BDS, MSc (Lond), PhD (Wits), MRDRCSEd, FRACDS, Walter.
Imaging of the colonoscope: magnetic, fluoroscopic, or neither?
Performance and perception of dental students using three intraoral CAD/CAM scanners for full-arch scanning  Khaled E. Ahmed, Ting Wang, Kar Yan Li, Wai.
Madoka Suzuki, Hideaki Fujita, Shin’ichi Ishiwata  Biophysical Journal 
Presentation transcript:

Fracture strength testing of crowns made of CAD/CAM composite resins Ryota Okada, Masaki Asakura, Akihiro Ando, Hirokazu Kumano, Seiji Ban, Tatsushi Kawai, Jun Takebe  Journal of Prosthodontic Research  Volume 62, Issue 3, Pages 287-292 (July 2018) DOI: 10.1016/j.jpor.2017.10.003 Copyright © 2017 Japan Prosthodontic Society Terms and Conditions

Fig. 1 Photographs and an illustration of fracture strength test of CAD/CAM crowns. (A) Abutment made of stainless steel. (B) CAD design for a crown specimen with a thickness of 1.5–2.0mm at the occlusal surface and 1.0mm at the margin. (C) CAD/CAM composite resin crown bonded to the abutment. (D) Loading points on the occlusal surface for testing. (E) Universal testing machine (model 4481; INSTRON) used in testing. Journal of Prosthodontic Research 2018 62, 287-292DOI: (10.1016/j.jpor.2017.10.003) Copyright © 2017 Japan Prosthodontic Society Terms and Conditions

Fig. 2 Schematic diagram for biaxial flexural strength testing. P is the total load at fracture (N). r1 is the radius of support circle (5mm), r2 is the radius of the loaded area (1.2mm), r3 is the radius of the specimen (6mm), and b is the specimen thickness at the fracture origin (1.0±0.2mm). Journal of Prosthodontic Research 2018 62, 287-292DOI: (10.1016/j.jpor.2017.10.003) Copyright © 2017 Japan Prosthodontic Society Terms and Conditions

Fig. 3 Fracture strength of CAD/CAM crowns before degradation testing. Each bar represents the mean and standard deviation (SD) values of five measurements. Different letters above the bars indicate statistical significance (p<0.05). Journal of Prosthodontic Research 2018 62, 287-292DOI: (10.1016/j.jpor.2017.10.003) Copyright © 2017 Japan Prosthodontic Society Terms and Conditions

Fig. 4 Fracture strength of CAD/CAM crowns before and after degradation testing. Each bar represents the mean and standard deviation (SD) values of five measurements. Horizontal lines above bars denote groups of means that are statistical significance (p<0.05). Journal of Prosthodontic Research 2018 62, 287-292DOI: (10.1016/j.jpor.2017.10.003) Copyright © 2017 Japan Prosthodontic Society Terms and Conditions

Fig. 5 Biaxial flexural strength of CAD/CAM materials before degradation testing. Each bar represents the mean and SD of five measurements. Different letters above the bars indicate statistical significance (p<0.05). Journal of Prosthodontic Research 2018 62, 287-292DOI: (10.1016/j.jpor.2017.10.003) Copyright © 2017 Japan Prosthodontic Society Terms and Conditions

Fig. 6 Biaxial flexural strength of CAD/CAM materials before and after degradation testing. Each bar represents the mean and SD of five measurements. Horizontal lines above bars denote groups of means that are statistical significance (p<0.05). Journal of Prosthodontic Research 2018 62, 287-292DOI: (10.1016/j.jpor.2017.10.003) Copyright © 2017 Japan Prosthodontic Society Terms and Conditions

Fig. 7 SEM images of surface in CAD/CAM materials before degradation testing. Journal of Prosthodontic Research 2018 62, 287-292DOI: (10.1016/j.jpor.2017.10.003) Copyright © 2017 Japan Prosthodontic Society Terms and Conditions

Fig. 8 SEM images of surface in CAD/CAM materials after degradation testing. HC had cracks (yellow arrows) in the surrounding area of the spherical fillers, whereas KZR2 had void spaces (yellow arrows) due to the dissolution or desorption of the fillers. Journal of Prosthodontic Research 2018 62, 287-292DOI: (10.1016/j.jpor.2017.10.003) Copyright © 2017 Japan Prosthodontic Society Terms and Conditions

Fig. 9 SEM images of fracture surface in different CAD/CAM composite resin crowns and lithium disilicate glass-ceramic crown after fracture strength testing. HC and KZR had a depression at the compression site (yellow arrow). Radial cracks were observed in KZR, KZR 2 and AVE (blue arrow). Journal of Prosthodontic Research 2018 62, 287-292DOI: (10.1016/j.jpor.2017.10.003) Copyright © 2017 Japan Prosthodontic Society Terms and Conditions

Fig. 10 Photographic images of different CAD/CAM composite resin crowns and lithium disilicate glass-ceramic crown after fracture strength testing. While the CAD/CAM composite resin crowns were broken consistently at the lingual cusp, the lithium disilicate glass-ceramic crown only had cracks, but not major fractures. Journal of Prosthodontic Research 2018 62, 287-292DOI: (10.1016/j.jpor.2017.10.003) Copyright © 2017 Japan Prosthodontic Society Terms and Conditions