Weighbridge Training Course Beijing - September 2017

Slides:



Advertisements
Similar presentations
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Advertisements

Is the shape below a function? Explain. Find the domain and range.
Functions S S T : S P R E A D S H E E T S SST 5 Spreadsheet 5 Function.
InnoSys Process Sequence. End Effector Components End Effector Prox Switch Load Cell Wire Conduit Crows Foot Nut Runner.
This workbook consists of four worksheets: Summary (tests) small tests BIG TESTS E X A M.
Registering for Classes. Go to the Senior to Sophomore homepage : Scroll down and click on the:
Calibration Procedure.  A winch calibration is completed via a linear interpolation between 2 points.  Requires 2 references  Known lower weight 
Weighing Patients for diagnostic purposes Staff toolkit.
Attainable Region S,S&L Chapt. 7. Attainable Region Graphical method that is used to determine the entire space feasible concentrations Useful for identifying.
Lesson Title DAGR Troubleshooting Lesson Number
Lecture 6: PLC: Timers and Counters
Logic Functions OR Operation
BLC Training for Instructors Presented By: Banner Health Learning & Development Team.
Scout Pro Training Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface.
Welcome to the Manage Scoping module of the “MIP Release 3 Study Workflow Training” course! This module guides you through the process of managing the.
It’s a GasBadge…
Controller Timers or timing processes Minimum green Maximum green Vehicle extension/passage time/gap time The minimum green timer becomes active.
Timers and Counters by Dr. Amin Danial Asham. References  Programmable Controllers-Theory and Implementation, 2nd Edition, L.A. Bryan and E.A. Bryan.
Computational Biology, Part 13 Spreadsheet Basics II Robert F. Murphy Copyright  1996, 1999, 2000, All rights reserved.
Sequencers SQO,SQC,SQL.
Version 3.0.
InnoSys Park Brake Tool Master Control Panel Screens Revision A, 12Dec /12/20071.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
717th MEDICAL COMPANY M-130 CHAFF DISPENSING SYSTEM.
PowerScheduler Creating a Load Only Scenario. Characteristics of Load Only Current Master Schedule serves as the Master Schedule for next year Much quicker.
CFM S4 Auditor Guide THE FUTURE OF CASH AUTOMATION.
Performing a Medix Drug Test. 2 Equipment required for a Medix drug test 1.
Joint Mission Planning System and Low Level Navigation
Idaho Transportation Department Winter Maintenance Best Practices
Chapter 8. Electrical Systems
Joint Mission Planning System Review
Welcome! To the ETS – Create Client Account & Maintenance
Commercial Skills Testing Information Management System (CSTIMS)
Mastering Autodesk Revit MEP 2016 CHAPTER 14: Circuiting and Panels
Tutorial 5: Working with Excel Tables, PivotTables, and PivotCharts
Weighbridge Training Course Beijing - September 2017
Goal: use counters to add integers
Microsoft Official Academic Course, Microsoft Excel Core 2016
LCGAA nightlies infrastructure
FedEx Billing Online (FBO) Non-Revenue Quick Guide
Joint Mission Planning System and Low Level Navigation

Lesson Four: Building Custom Patient Lists
T-6B On-Board Oxygen Generation System (OBOGS)
Measurements and Uncertainties
Automatic Test Station for GasAlertClip Extreme Portable H2S Monitors
Register training Using the college register system
LIFEPAK® 1000 Defibrillator Orientation Guide
Unit 4 Polynomials.
This presentation document has been prepared by Vault Intelligence Limited (“Vault") and is intended for off line demonstration, presentation and educational.
التدريب الرياضى إعداد الدكتور طارق صلاح.
Lesson Four: Building Custom Patient Lists
Weighbridge Training Course Beijing - September 2017
Digital Chart Recorder Operation
PrognosTILs app Damien Drubay –
Claims Upload and Security
Introduction To Computing BBA & MBA
Using a microscope Key points:
Malaysia- Economy Report Highlights
PowerChart Overview Tab New Feature for Physicians
Add Studbook Animal.
Lesson 4: Managing Events in Case Tracking
Loading… Please Wait $ $ $100 $100 $100 $100 $100 $200 $200 $200 $200 $300 $300 $300 $300 $300 $400 $400 $400 $400 $400 $500 $500 $500 $500 $500.
VISUAL COMMUNICATION USING ADOBE PHOTOSHOP CREATIVE SUITE 5
[INDONESIA] - Economy Report Highlights
Ladder programming Counter Instruction S7 300
This presentation document has been prepared by Vault Intelligence Limited (“Vault") and is intended for off line demonstration, presentation and educational.
Microsoft Official Academic Course, Microsoft Excel Core 2016
T-6B On-Board Oxygen Generation System (OBOGS)
Partner Portal Training document
Presentation transcript:

Weighbridge Training Course Beijing - September 2017 Zero Setting Devices

Zero setting devices A zero setting device is a device for setting the indication to zero when there is no load on the load receptor The following are zero setting devices found on NAWI: Semi automatic zero-setting device Non-automatic zero setting device Zero tracking Automatic Zero setting device

Zero setting devices Semi automatic zero setting device Device for setting the indication to zero automatically following a manual command ( zero button) Non automatic zero setting device Device for setting the indication to zero by the operator Zero tracking device Device for maintaining the Zero indication within certain limits automatically Automatic zero setting device Device for setting the indication to zero automatically without the intervention of the operator Equilibrium is stable means = it can maintain the reading / maintain the accuracy requirement

Zero setting devices Zero setting requirements The effect does not alter maximum capacity The accuracy is ± 0.25e The range is 4% of max for zero setting and zero tracking Equilibrium is stable means = it can maintain the reading / maintain the accuracy requirement

Zero setting devices Zero tracking device To test zero tracking: Reset the instrument to zero using the zero setting device Apply a load of 1e to the load receptor If after 5 seconds the indicator changes and stabilises at 1e :Pass remains on zero : Fail

Zero setting device accuracy Non-Automatic and Semi-automatic zero -setting device To test non-automatic and Semi-automatic zero setting: Apply a load that is within the range of the instrument. This range varies between 0 to 4% of maximum capacity , in most cases it will be ± 2% around zero Add small additional loads of 0.1e to take the load just below the next change over point Zero the instrument using the zero setting device ( zero button) Ensure that: The numerical indicator displays zero

Zero setting device accuracy The zero indication lamp or enunciator is illuminated Apply a load of 10e Lightly apply an additional 0.25e If the instrument changes and stabilises at +1e from the original indication the instrument fails If the indication remains unchanged firmly apply an additional 0.5e If the indication changes and stabilises at +1e from the original indication the instrument passes If the indication remains unchanged the instrument fails

Zero setting device accuracy (cont’d)

Zero setting device accuracy Automatic Zero setting To test automatic zero setting: Initiate the automatic zero setting device by: Applying a load of 5e Zero the instrument using the zero setting device and remove the load Wait for the automatic zero setting to occur and the indication displays zero , this should take a minimum of 5 seconds Note: if the indication does not change after 15 seconds , the instrument does not have automatic zero setting and should be tested as semi-automatic zero setting Quickly apply a load of 10e to the load receptor Lightly apply an additional 0.25e

Zero setting device accuracy Automatic zero setting continued If the indication changes and stabilises at +1e from the original indication then the instrument fails If the indication remains unchanged firmly apply an additional 0.5e If the indication changes and stabilises at +1e from the original indication the instrument passes If the indication remains unchanged the instrument fails

Zero setting device accuracy Non-self indicating Instrument ( eg. Steelyard weighing instrument) It is essential that the instrument is set on zero before any tests are performed After completing any test , remove the load and visually check that the instrument has returned within ± 0.25e of its equilibrium position. If it has not returned to its equilibrium position apply 0.25e to the load receptor. Then: If the indicator moves through its equilibrium point , the instrument passes If the indicator does not move through its equilibrium point , the instrument fails

Zero setting device accuracy Analogue indicating instrument It is essential that the instrument is set on zero before any tests are performed After completing any test , remove the load and visually confirm that the instrument has returned to within ± 0.25e of zero

Zero Setting Devices That’s the End of the presentation Are there any questions? Thankyou