Epoc® blood analysis: a cost-effective point of care solution for the entire healthcare enterprise1 November 2010 1. A Patient-centred Approach. June.

Slides:



Advertisements
Similar presentations
Using the Palm Pilot for Data Collection. Overview: These procedures will assist when using the Palm Pilot for: Physical Inventory Counts Bar Code Collection.
Advertisements

Separation of blood components
NexSentry Imaging Solutions
An Example of a Portable Computing Device. A PDA as an Example of a Portable Computing Device Recharger and connection to computer for replication Recharger.
3/17 Dividend Street, Mansfield, 4122, Queensland, Australia phone: web: The SuperCycler A Software.
5387 Avion Park Drive Highland Heights, Ohio INTUNE v4.4 Demonstration.
NEXGEN Four All automated microplate processors today can perform the steps required to process an ELISA microplate test However, most systems today operate.
Glucose, Whole Blood Accu-Chek Inform II®
StatSensor® Creatinine Operator Training Program
Neoteric Technology Ltd – All Rights Reserved - © 2006
PulseHR Time and Attendance software development and coding web development, web hosting IT project management and consulting Str. Ghioceilor.
Simple Accurate Reliable Economical. M Series Platforms 16 Parameter, 3 Part Differential Systems  Open Tube Sampling  Closed Sampling  Automated Sampling.
Jewelry Inventory Management Software Your Logo Here Welcome to a demonstration of Del Mar Data Systems Jewelry Inventory Management.
MCDST : Supporting Users and Troubleshooting a Microsoft Windows XP Operating System Chapter 5: User Environment and Multiple Languages.
EPOCH 1000 File Management Data Logging and Reporting
Bar|Scan ® Asset Inventory System The leader in asset and inventory management.
SDReaderCE An Overview on Use and Functionality. Using SDReaderCE After loading the route to the handheld from SDReader6, select the route folder from.
GeneXpert Installation and Xpert MTB/RIF Set-up
GPS. Meet the Bad Elf GPS Pro The Bad Elf GPS Pro offers the first Apple approved GPS with an informative user interface.
Presented to: Name of Customer Enhanced MET ONE 3400 Series Portable Airborne Particle Counters.
Setting up the NICO monitor to measure pulmonary dead space fraction (V d /V t )
Data Management Solutions DMS Products Overview IntelliTrack Inc.
Ch 11 Managing System Reliability and Availability 1.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Technical Support Training Common Tech Support Enquiries.
Strengthening Supportive Supervision Training for Supervisors Session 3: Smartphones, introduction to SS Tool.
1 BRIDGEPAD (BP) SYSTEM TRAINING Adapted for ScoreBridge Users By John de Ridder PSBC Revised 2 November 2009.
Josh Probert – Yankee A Prototype based on Sierra’s SRS.
Accu-Chek Inform II Blood Glucose Monitoring System.
ENVIROTRAC: A Premier Chamber Monitoring and Data Acquisition System Envirotrac A Guided Tour.
Technical Support Training Overview
Dynatest LWD Program - Sections
Home Media Network Hard Drive Training for Update to 2.0 By Erik Collett Revised for Firmware Update.
Cullen College of Engineering RFID-Based Solutions for Piping Technology Piping Tech & UH July, 2007.
THE EASY WAY TO STAGE ZEBRA’S ANDROID MOBILE COMPUTERS
Iomega iConnect Wireless Datastation Training Presentation
© CCI Learning Solutions Inc. 1 Lesson 5: Basic Troubleshooting Techniques Computer performance Care of the computer Working with hardware Basic maintenance.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Epoc Veterinary Software Dave McComas. Vet Software Released in Two Phases Phase I Due for release 1 st April 2011 “epoc Veterinary analyser” bottom right.
StageNow The easy way to stage Android mobile computers from Zebra Technologies.
Access Method. “ ” A key is usually intended to operate one specific lock or a small number of locks that are keyed alike, so each lock requires a unique.
ACCU-CHEK Inform II Operator Training
SNG via Webinar. Where’s Webinar??  Double click Aflac 2000 folder  Highlight “SNGWebCommunicator”  Right Click and “Send To - Desktop”
IPad Basic Training Everything you wanted to know but were afraid to ask a 3-year-old.
A Cost Effective Centralized Single parameter Patient Monitoring System Abstract Lack of Medical monitoring equipment's in rural areas of underdeveloped.
Component 8/Unit 1bHealth IT Workforce Curriculum Version 1.0 Fall Installation and Maintenance of Health IT Systems Unit 1b Elements of a Typical.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
THE NEW MOBILE WORKSPACE Enable Business Applications on Mobile Devices hopTo Work “I am amazed to see how easily hopTo transforms the user interface of.
Quick Start Guide ST30/ST32 Series mobile computer.
Freestyle Precision Pro
Frequently Asked Questions (FAQ)
Pilot Walktour Pack Operation Guide V3.4
Cold-Chain Expert, Total Solution Quality Precision Service Value
DEVICE ORIENTATION ICT4D Session 2.
Software Application Overview
Pilot Walktour Pack Operation Guide V3.2
Always Connected introduces Tigo SMART 3.0 This guide is interactive!
StatSensor® Creatinine Operator Training Program
Bomgar Remote support software
PTS Detect™ Cotinine System Training
vInspect Application Training
AQT90 FLEX – the product 28/11/2018.
Administration Training
Rapid Automation Design
PHASE IDENTIFICATION UNIT (PIU)
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
Tuda G Kemri/Wellcome Trust Research Program
Diagnostics Analytical 920 LC Semi-Prep 940 LC
Piccolo Xpress™ Moderately Complex Training Demonstration
POINT OF CARE TESTING ABBOTT i-STAT System. Objectives: Identify the i-STAT System Features Collect and Handle Samples Perform a Patient Test Conduct.
Presentation transcript:

epoc® blood analysis: a cost-effective point of care solution for the entire healthcare enterprise1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory Care & Sleep Medicine

Contents: System components Test card analytes Features and benefits Sample requirements How to perform a test Wireless capabilities Operational specifications QC requirements Navigating through the reader screens Quality Controls

epoc® Host Mobile Computer epoc® Reader epoc® BGEM Test Card epoc® System epoc® Host Mobile Computer epoc® Reader epoc® BGEM Test Card

epoc® System: epoc® Data Manager (server-based)

epoc® Host Components Touch screen for navigation, using stylus Barcode scanner Battery-powered for portability

epoc® Test Cards: Smartcard Technology Measurement region Sensor module: contact surface Sensor module: sensor surface valve Test Panel type Blood waste chamber Bar Code Sealed calibrator reservoir Sample entry port TEST CARD - TOP TEST CARD - BOTTOM

epoc® BGEM Test Card Analytes

Test Menu – Calculated Values

Test Cards Easy to use Room temperature storage ~92uL WB sample Integrated calibration and quality checks Results in about 30 seconds after patient sample addition Bar-coded for error-free panel identification, lot number, expiry and inventory records 12 analyte capacity on one test card

epoc® Reader Components

Features Host: Integrated, modular barcode scanner Wireless Communication Bi-directional communication with epoc Data Manager & Readers via Wi-Fi and Bluetooth Flexible epoc Host Software: Reference and critical ranges by sample type Respiratory and vent parameters Automated Critical result handling Automated Reporting (read back) Operator / Patient / QC lockouts

Features Reader: Patient test time of ~30 seconds Automated, internal equivalent QC No maintenance Offers portable or fixed functionality A/C Power or Rechargeable Battery Sensor electronics: Amperometric- measures current Conductometric- measures conductivity Potentiometric- measures voltage Bluetooth technology built-in

epoc Data Management (EDM) software: Features epoc Data Management (EDM) software: Web-based (accessible via any network) Manages the entire epoc system (reports, inventory management, can be interfaced)

>92 µL sample (non-volumetric) Whole blood Sample requirements >92 µL sample (non-volumetric) Whole blood Arterial, venous, capillary Syringes or evacuated tubes for sample collection Evacuated tubes not recommended for ABGs Without anticoagulant or with lithium, sodium, or balanced heparin Must use balanced heparin if analyzing iCa epoc Care-Fill capillary tubes with balanced heparin (90 µL)

epoc® Test Process: Scan operator ID and enter password Insert test card into reader to start calibration (165 sec) Data entry (scan patient ID, enter patient temp, vent data, etc.) Collect blood sample (whole blood from arterial, venous or capillary sources) Introduce sample into card (within 5 min of calibration) View result (after 30-second test time) Transmit result to EDM and LIS via WiFi (1-2 seconds)

Existing Wi-Fi Access Points epoc® Wireless Communication Remote workstation LIS / HIS Existing Wi-Fi Access Points EPOC™ Web-based Data Manager

Operational Specifications Operation: AC or rechargeable battery Operating temperature: 15° to 30° C Relative humidity: 85% non-condensing Barometric pressure: 400 – 825 mmHg Operation on fully-charged battery: ~50 cards Time to recharge Reader: ~4 hours

QC requirements Verification of Newly Received Test Cards Cards shipped to Australia with temperature monitors Verification of Reader Performance When a connection between the Reader and the Host is established, an electronic self-check is performed. If the connection is still established after 8 hours, the Host will disconnect from the Reader. Upon reconnect, another self-check will be performed. Every device is calibrated prior to specimen testing, eliminating the need for daily controls. External controls are run when a new lot is started and every 30 days thereafter or as required.

Navigating through the Reader Screens

Log In and Start Up Screens Start Up Screen –upon reset of Host (initiates program, reads files & configures software)

Main Reader Screen ‘Lock’ icon (dedicated readers always listed) EDM Sync appears only when Host configured to EDM (exchange info)

Indicators

Navigation Lightly press stylus on Reader icon or list for menu Tap for selection

Reader Screen Print not enabled during test Save button enabled after test complete. Info entered after test saved. Close Reader connection button – cancel test and close connection

epoc® Host Application User Interface Tool bar (Bottom of screen) Screens (Bottom – Connected Readers + Open Test Record) Multiple Pages (Upper left- Tabs. Greyed out=Not for Use)

Test Pages Test in Progress (progress bar) Test Results (Measured, Calculated,Corrected) 2nd ID Hemodilution (hematocrit correction) Sample (Unknown, arterial, venous, mixed venous, cord, capillary) Temp (patient body temp for pH, pCO2 & pO2 corrected values) Test Selection (Select all, Clear all, Gases, Electrolytes)

Additional Test Information Pages

Additional Test Information Pages cont.

Screens when Running a Patient Sample Calibration process takes approx. 165 secs

Screens when Running a Patient Sample cont.

Timing of Sample Introduction After calibration, message displayed to insert sample Bar indicates time remaining Sample must be introduced within 5mins

Screens when Running a Patient Sample cont.

Critical Values Action Reporting of critical range failure On screen at the time of event Simple drop-down menu Simplifies reporting Assures compliance Unique feature Requested by customer

Basis for epoc® Measurements epoc measures either current, voltage, or conductance Potentiometric – Measures voltage Ion selective electrodes Sodium Potassium Ionized calcium pH pCO2 Nernst equation is used to convert the voltage into the assay values Amperometric – Measures current pO2 Glucose Conductometric – Measures conductivity Hematocrit

Quality Controls

Overview Reader/Host Quality Controls Test Card Quality Controls Barcode Scanner Thermal System Operating Environment iQC Test Card Quality Controls Card Temperature Monitors Verification of card shipment External Liquid Quality Controls What QCs do I run How often How to run controls

Reader/Host Quality Control Barcode Scanner Reader Within the Epoc Reader is an internal Barcode Scanner that is used to read the Test Card Barcode during card insertion. The Barcode Scanner is activated upon entry into the Card Insertion Slot where a red light inside is visible. Each Test Card has a Barcode printed on the bottom white label that contains the card lot number, serial number, “use by” date and card type. Smooth insertion of card into reader is essential. Multiple insertions are allowed as long as the card has not been damaged or the calibration sequence initiated. Successful insertion has audible “beep” and a solid red test status indicator informs of unsuccessful test. Section 5.12: Barcode Scanner

Reader/Host Quality Control Thermal System The epoc Reader is equipped with a Thermal System that provides a temperature controlledenvironment for Sensors during a test. The Heaters are two (2) Metal Heating Blocks located above and below the Test Card near the sensor module. When a Test Card is fully inserted into the Reader, the Heaters are brought in contact with the Test Card. Efficient thermal contact of the Heaters with the Test Card is provided by a spring loaded mechanism. The heating cycle begins upon successful insertion of a Test Card and is controlled by algorithms present in the Reader’s Microcontrollers. The Heaters are calibrated so that the fluid over the pO2 sensor is at 37°C. Section 5.13: Thermal System

Reader/Host Quality Controls Operating Environment Temperature Internal ambient temperature monitor 15°C – 30°C Atmospheric pressure Internal barometric pressure sensor 400 – 825 mmHg Relative humidity Electronic QC checks leakage current Humidity must be <85% at 30°C Temperature The Reader can be operated between 15°C-30°C. There is an internal Ambient Temperature Monitor that will disable the Reader function if room temperature falls outside of this range. A Reader brought from a warm or cool environment, such as during shipment, must be allowed to equilibrate before use. Atmospheric Pressure The Reader can be operated at atmospheric pressures between 400–825 mmHg. An internal Barometric Pressure Sensor monitors atmospheric pressure and disables the Reader function if outside this range. Relative Humidity The Reader must be used where the relative humidity is less than 85% at 30°C, noncondensing. The Reader’s Electronic QC checks leakage current within the Reader to detect compromised performance due to high humidity. Test Position The Reader is designed to be portable and to be used at the point-of-care (POC). It may be used within the patient vicinity, but it is not intended for direct patient contact. The Reader must rest on a flat horizontal surface without being moved during the entire testing process. Water Ingress The epoc Reader has not been evaluated to protect against the ingress of water. Degree of protection against ingress of water: IPXO Always keep the epoc Reader in a dry location. Immediately wipe away any liquids on the outside Reader surfaces (using appropriate Biohazard protection). Always follow the recommended cleaning procedure. Section 5.14: Operating Environment

Reader/Host Quality Controls 3 phases of Internal QC testing (iQC) Initialisation Performed upon connection and at start of test before calibration In-Calibration Performed after the calibrator is delivered to the sensor array During Sample Measurement Monitor procedure and sample integrity Each time a Test Card is run there are multiple monitoring tests taking place in the background that are used to control the quality of the test procedure and flag nonconforming tests. There are three (3) phases of QC tests performed by the epoc System: Initialization: An initial battery of tests covering 2 different levels over the dynamic range is performed by the epoc Reader (epoc Reader electronic QC test) every time the Reader connects with an epoc Host. In addition, QC tests are performed by the epoc Reader on the card and on the operator process after card insertion during initialization. N.B. – If connected for > 8 hrs host forces reader disconnect and must reconnect therefore re – QC-ing 2. In-calibration: QC tests performed to assess the card and sensors’ conformance during the calibration interval before sample is introduced. 3. During sample measurement: QC tests performed to monitor the operator procedure and sample integrity during and after sample introduction. A. Operator Procedures For example the system will flag the following conditions and not deliver a test result when: • Using an expired card • Rerunning an already used test card • Putting in too little sample • Introducing the sample too rapidly • Introducing the sample too slowly • Introducing the sample at the wrong time B. Sample Integrity Tests The system also detects abnormalities in the introduced sample including: • Samples with air bubbles • Samples with some interferents Limitations: The epoc System does not detect and flag pre- analytical sample handling problems. i.e. it measures the sample it receives. Preanalytical errors include sample hemolysis, sample degradation through ageing and improper anticoagulation, gassing up of non-anaerobically handled specimens, contamination with interfering chemicals arising from improper sample collection. These sample handling errors are not detected, and require proper User training for their control and minimization. Section 11.6.2: Overview of epoc System Internal QC (iQC)

Test Card Quality Controls Card Temperature Monitors Change to external controls Card Temperature monitors during shipping Test Card shipping cartons include two (2) Temperature Monitors, which change color when the shipping temperature is outside the specified range. A Low Temperature Monitor turns red below 5° C. A High Temperature Monitor turns red above 30° C. Temperature monitors must be checked when Test Cards are received to verify that the temperature limits were not exceeded during shipment. If one or both of the temperature monitors indicate any RED then the Test Cards were stored outside of the allowable temperature limits. Place the card shipment on “Hold” and isolate from possible use. Contact Epocal Inc. immediately to arrange for exchange of the Test Cards. Section 4.2.2: Shipping Controls as shipped from Canada.

External Liquid Quality Controls Verification of Card Shipment From each lot analyse 2 levels of fluid controls in duplicate on any verified reader. Section 9.2.1: Verification of newly Received Test Cards

External Liquid Quality Controls Control Fluids Bio-Rad Liquichek Blood Gas Plus EGL Level 1 and Level 3 Used for BGEM Eurotrol BGEM Mission Diagnostics Hematocrit Level A and Level B Used for Hematocrit Section 9.2.3: Control Fluids

External Liquid Quality Controls Frequency As per verification of card shipment: With each shipment cards must be analysed in duplicate with 2 levels on any verified reader. (Take average, compare to Value Assignment Datasheets) In keeping with any accrediting bodies, federal, state/territory guidelines AACB WP, AACB QC/QA Draft Guidline (April ‘10) – Guidelines for conducting quality control and quality assurance for PoCT Medium complexity devices utilising cartridge based technology (eg i-STAT, DCA) shall have a minimum of two liquid QC samples tested each month unless a higher frequency is suggested by the manufacturer. These two QC samples should contain normal and abnormal levels. In addition to the regular QC program, QC testing should also be undertaken when: 􀂙 The lot number of consumables changes 􀂙 There is a new delivery of consumables 􀂙 An operator lacks confidence in a patient result 􀂙 The health care professional does not believe that the PoCT result fits the patient’s clinical picture 􀂙 Substantial maintenance procedures have been carried out on the device. 􀂙 The device has suffered a physical insult (eg dropped, temperature extremes – hot or cold, etc) AACB WP, AACB QC/QA Draft Guidline (April ‘10)

External Liquid Quality Controls Precautions Follow manufacturer's storage instructions Allow equilibration (4 hours min) For Blood Gas QC Handle fluid carefully Once opened analyse immediately Multiple tests only if using multiple readers Hematocrit QC Not gas sensitive 9.4.2 Before Use If ampoules are taken from cool storage, equilibrate Ampoule to Room Temperature (20-25°C). Equilibration time for blood gas QC Fluids is four (4) hours minimum. 9.4.3 Ampoule Use for Blood Gas QC fluids Handle Fluid carefully to avoid air contamination. Air contains less than 1mmHg pCO2 and about 150-180mmHg pO2. Gas Levels and pH may change when Fluid is exposed to air and/or transferred into plastic Syringe. Quality Control Fluids contain dissolved gases, so they become very unstable over time after opening the Ampoule. Once opened, Fluid should be analyzed immediately. Multiple Test Cards can be tested using one (1) Ampoule only if tested at same time on multiple Readers. Never use last 0.5 mL of Control Fluid in Syringe. Always use one (1) new Ampoule for each Test Card tested when testing multiple Test Cards using a single epoc Reader. 9.4.4 Ampoule Use for Hematocrit QC fluids One or multiple Test Cards can be tested using a single Ampoule. Hematocrit Controls Fluids are not gas sensitive. Fluids do not require special handling to prevent air contamination. Section 9.4: Aqueous Fluid Handling

External Liquid Quality Controls Procedure Tests must be run as ‘QA test’ QA test results are stored separately from Blood Test Results in epoc Data Manager. Shake ampoule - 5 to 10 secs Hold at tip and at bottom with forefinger and thumb Tap, if necessary Snap ampoule off at neck Immediately transfer into syringe Transfer into test card 9.4.6 Procedure All Aqueous Control Fluids, including Proficiency Test Samples, must be run as QA Test when using epoc System. QA Test feature provides following characteristics: • Ranges are increased so User can test Levels at, or just outside of, Reportable Range • Hematocrit Result is reported as “uncorrected”, i.e. Result does not take into account Sodium Concentration of Sample. This allows for independent evaluation of Hematocrit Sensor from Sodium Sensor. Note: Sodium Sensor performance is verified separately. • QA Test Results are stored separately from Blood Test Results in epoc Data Manager. Immediately before use, shake Ampoule vigorously for 5 to 10 seconds to equilibrate liquid and gas phases. Always hold Ampoule at tip and at bottom with forefinger and thumb to minimize increasing temperature of Fluid. If necessary, tap Ampoule Tip to return Fluid into bottom section of Ampoule. Protect fingers with gauze, tissue or glove, or use Ampoule Breaker to snap off Ampoule Tip at Neck. Immediately transfer Fluid from Ampoule into a plain Syringe, avoiding fast suction and thin needles in order to preserve gases in Fluid. Transfer Fluid immediately into Test Card. Section 9.4.6: Procedure

External Liquid Quality Controls Procedure (con’t) Recommendations 1mL or 3mL sterile syringe 16-20 gauge blunt (drawing up) needles Draw 1mL from bottom of ampoule If air bubble present, do not invert syringe 9.4.7 Transfer with Syringe Epocal recommends 1 mL or 3 mL plain sterile Syringes with 16-20 gauge blunt needles to transfer Control Fluids from Ampoule to the Test Card. While loading syringe, slowly draw about 1mL of Fluid from bottom of Ampoule. If air is trapped between leading edge of Fluid and Syringe Plunger, never invert Syringe to expel because this will not affect solution near front of Syringe. If Air Bubbles are continually drawn into Syringe, or if a Bubble is trapped near Syringe Tip, discard Ampoule and Syringe. Begin again with a fresh Ampoule and Syringe. Before inserting Fluid in Test Card, expel one (1) or two (2) drops from Syringe. Remove blunt needle and apply Syringe Luer in Test Card’s Sample Introduction Port as during normal Blood Test procedure. Section 9.4.7: Procedure

External Liquid Quality Controls Value Assignment Datasheet Contain Target values, ranges. Never use values/ranges from pack insert Value Assignment Datasheets contain Target Values and Acceptable Ranges for Aqueous Control and Calibration Verification Fluids specific to the epoc System. Never use Target Values or Ranges from Package Insert included with Control Fluids. Section 9.5: Value Assignment Datasheet

External Liquid Quality Controls Value Assignment Datasheet Each Value Assignment Datasheet (VAD) is identified by Fluid Name, Level, Lot Number and epoc System Sensor Configuration Version. Assure all information is correct when using VAD to determine acceptability of Results. The epoc System Sensor Configuration version is located in epoc Host’s Help, About Menu. Section 9.5: Value Assignment Datasheet

Thank you.