Application of MSR H2 sensor transmitter in Battery Room

Slides:



Advertisements
Similar presentations
60% of deaths come about when someone tries to rescue someone else!
Advertisements

By Nayyab Nadeem IX White Industrial Use of a Computer Computers are useful tools for warehouses, distribution centers, manufacturers and other industrial.
Who is BAPI? Manufacturer of Sensors for HVAC/R Founded in 1993
Brownfield / Landfill Applications
Basic Air Monitoring Concepts And Use Of The Altair 4 Gas Meter
TraceTek Flashers. 2 Two simple units for visual leak detection In some applications it makes sense to eliminate wiring and expensive control room equipment.
MULTI-GAS MONITOR FOR CONFINED SPACE APPLICATIONS
 Volt- Is the measurement unit of the electrical potential.  Electrical Potential- The difference of voltage between two points in a circuit. It is.
Patrick Thornton, SNS/FPE June 9, 2008
WELCOME TO Gas Tester Training O2, LEL Monitoring
E VERY L IFE H AS A P URPOSE… Toxgard ® II Gas Monitor.
MINE GASES. Normal Air is made up of: Nitrogen 78% Oxygen 21% Trace Gases 1%
Tyson Burt Mathieu Gagnon
Combustible Dust Preventing and Mitigating the Effects of Fire and Explosions Developed by Western Iowa Tech Community College This material was produced.
GPS Tracking System An autonomous user tracking system is employed to navigate the vehicle using GPS data. The following diagram demonstrates the tracking.
1 Daya Bay RPC Gas Safety System - Gas Cabinet Test Report Changguo Lu, Kirk McDonald Princeton University (October 11, 2009)
Water Detectors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
1 LANDFILL GAS TRAINING. 2 INTRODUCTION  TYPE OF MONITORING -Screening -Specialized  GOALS.
Bi-Weekly Safety Meeting November 29, The days of using canaries in mines as primitive gas detectors are long gone..they've been replaced by fixed.
Truck Transport in India is a Major Part of Our
Misuse of Combustible Gas Meters Supervisor Training 1/11/08.
Atmospheric Monitoring. ATMOSPHERIC MONITORING INSTRUCTIONAL GOAL The participant will understand the need for atmospheric monitoring and the types, uses,
Mine Gases. Normal Air Is: Nitrogen 78% Oxygen 21% Trace Gases 1%
Strong room Vaults How do vault doors work  Strong room vaults are a kind of safes meant to protect your valuable assets from burglary, theft and fire.
충전시발생하는 황화수소는 유독가스이며, 불꽃에 의해 폭발가능 There is a danger of explosion when the concentr ation of hydrogen gas exceeds 3.8%. In addition, incidents.
Safe Handling of Flammable and Combustible Liquids.
Our website: Address: Village – Jawad, Near – Pipaheda Chunginaka Over Bridge, Rajsamand,
High Quality Balcony Awnings
Benefits of Adding Commercial Awnings
(345) (345)
Carbon Monoxide Detection: Code and Legislation Updates
Trench Hazards Introduce the module. Trenching & Excavations Continuing Education Third Quarter 2017 Session 3.
Welcome To Sun Sterifaab Pvt. Ltd
Safe Handling of Flammable and Combustible Liquids
SUB-STATIONS.
Gas Leakage Detector System
Global KeyAccess Technologies Ltd.
Gas Detection in Water Treatment
Steam Generation In any industrial process, large quantities of steam are consumed. If natural gas is used to heat the boiler water it is often advisable.
Fire Sprinkler System.
Data Management Solutions for a Modernized HIS
LPG / PNG Detection and Alarm, Control System - EK Engineering
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Critical Environment Control Solutions
Electrical Equipment CSP uses conventional electrical equipment in the majority of areas All installations follow the mandatory electrical codes The.
AQA GCSE 2 Energy storage Design and Technology 8552 Unit 2
Industrial Instrumentation: Transmitters
THUM Adapter Impact on Hazardous Area Classification
The FG series of explosive and toxic gas detectors and panels
Global Cryocooler Market to Witness 7.3% CAGR during 2017 – 2023.
Carbon Monoxide.
Electromagnetic Flow Meter Phone: +(91)-(20) /
Phone: +(91)-(20) /
Face Recognition App - Sara Analytics
Car Battery Recharging.
Elegant Balcony Awnings at Attractive Price
Automation & Security Pvt. Ltd.
Electrical Equipment CSP uses conventional electrical equipment in the majority of areas All installations follow the mandatory electrical codes The.
Click anywhere to get started…
RV Safety Alarms Education Test
Ventilation Measurement Tracer Gas Decay Testing
RV Safety Alarms Education Test LP Gas Alarms / Detectors
Safe Handling of Flammable and Combustible Liquids
(name) (number) Hazard Analysis and Risk Assessment Operations
ALL-ELECTRIC TEMPERATURE CONTROL FOR CHILLED, FROZEN AND
“Any Sufficiently Advanced Technology Is. Equivalent To Magic. ”
© 2016 Global Market Insights. All Rights Reserved Pressure Switch Market trends research and projections for 2019 – 2025.
India Lithium-Ion Battery Market
©2018 Graphical Research. All rights reserved. Factors behind $14bn North America Intelligent Vending Machine Market by 2025:
Presentation transcript:

Application of MSR H2 sensor transmitter in Battery Room By : ALVI AUTOMATION ALVI AUTOMATION (INDIA) PVT LTD www.alviautomation.com | info@alviautomation.com ALVI AUTOMATION (INDIA) PVT LTD

As lead acid batteries are charged, minute quantities of hydrogen (H2) gas are produced. Normally, the amount of hydrogen generated during charging is not of a sufficient quantity to cause concern. There are instances however, where for various reasons, hydrogen may accumulate to create potentially hazardous gas conditions. Battery back-up installations for equipment such as telephone switching systems and computers are normally situated in small rooms with little ventilation. This confined space provides an excellent opportunity for hydrogen to accumulate and reach combustible levels. ALVI AUTOMATION (INDIA) PVT LTD

In most instances, the sensor/transmitter is mounted on the ceiling, while the monitoring panel is mounted outside the room. Any build-up will cause an alarm and/or initiate ventilation. A second common application is in warehouses where battery powered forklifts are used. Charging stations are commonly lined up in areas where a large number of vehicles can be charged simultaneously. Because of the size and number of batteries, dangerous levels of H2 can accumulate. Key Factors: Relative density of hydrogen is 0.069.  Therefore sensors should be mounted at or near the ceiling, away from any source of fresh air, which may dilute the sample. Remote sensors are normally used, with panels being mounted away from hydrogen source.  The customer chose MSR catalytic diffusion system to monitor the battery rooms for hydrogen in the 0-100% LEL range. ALVI AUTOMATION (INDIA) PVT LTD

This explosive hydrogen gas is produced during battery charging. The MSR H2 sensors like MA-series, MC2-series and Poly-Xeta 2 series are used for monitoring battery recharging areas. The Sensors are employed for detecting hydrogen concentration in the air . This explosive hydrogen gas is produced during battery charging. MSR sensors protect person and equipment against explosions caused by ignition of the hydrogen gas. MSR MA-series and latest MC2-series are suggested for battery room application like data center inside a commercial building . MSR Poly-Xeta 2 series are usually suggested for battery room applicator in Industries /Plants . Some industries include: Telecommunications/Computing Utilities, Financial Services, Publishing Transportation Services , Automotive. ALVI AUTOMATION (INDIA) PVT LTD

Physical Appearance For Commercial Applications : Will Phase out by end of 2017 MSR MA series H2 Model no : MA-2-3440-F-M | IP 44 | also available in IP 54 and IP 65 ALVI AUTOMATION (INDIA) PVT LTD

For Commercial Applications : Latest MSR MC2 series H2 Model no : MC2-D-P3440-A*-0 | IP 54 | Also available in IP 65 ALVI AUTOMATION (INDIA) PVT LTD

For Industrial Applications : Latest MSR Poly-Xeta 2 series H2 Model no: PX2-X-X-P3440-A* |IP 65 to 68 |ZONE 1 and 2 ALVI AUTOMATION (INDIA) PVT LTD

Contact Us: ALVI Automation India Pvt Ltd (A Div. of ALVI Technologies Pty Ltd, Sydney, Australia) Phone: 0141-2293968 / +91-7091777274 / +61-411287513 / +91-9471515909 Email:        info@alviautomation.com           sales@gasalarm.com.au           Website:  www.alviautomation.com           www.gasalarm.com.au Address:  301, Plot no. 28, Nannu Marg, Devi Nagar, Jaipur-302019 Rajasthan (INDIA) ALVI AUTOMATION (INDIA) PVT LTD

Stay Safe, Stay Healthy Thank You!!! ALVI AUTOMATION (INDIA) PVT LTD