RF and DC Cabling Policy for KAGRA ISC

Slides:



Advertisements
Similar presentations
KAGRA ISC Electrical Components Layout Yuta Michimura Ando Group Department of Physics, University of Tokyo April 17, 2015.
Advertisements

Connectors Connectors are a major cause of equipment failure. Pins are wired incorrectly, bare wires touch and short circuit or connector pins are accidently.
Power supply cable Charge injection 3 channels readout (external cables to the scope) 3 channels readout (internal cables) Set up for reading two cards.
L1 Meeting 11/4/2004 – Mario Camuyrano BLS-to-ADF Transition System 230 ns 100 mV/div 200 ns/div Existing and proposed calorimeter trigger rack layouts.
40m Suspension Electronics Benjamin Abbott California Institute of Technology 10/18/01 G R.
Internal Seismic Isolation (ISC) Overview Report for the August CDS meeting Ben Abbott Caltech.
Connector Board Meets customer need 6. Accept data from auxiliary external cameras and INS units Power Input Regulation Monitoring.
Electronics and Cables around IMC Common Mode Servo Board Yuta Michimura Ando Group Department of Physics, University of Tokyo August 10, 2015.
IC-CAP Modeling Configuration Agilent Technologies November 01, 2005 Page 1 Agilent IC-CAP Modeling Configuration - Block Diagram ( GHz) E8363B.
Hardware-In-The-Loop Testbed Team 186: Douglas Pence, Ken Gobin, Aaron Eaddy, Advisor Sung Yeul Park Department of Electrical and Computer Engineering,
1 Why have we chosen to use the serial port, when it is more complicated and offers fewer connections than the printer port? For a beginners’ course using.
IC-CAP Modeling Configuration Agilent Technologies November 01, 2005 Page 1 Agilent IC-CAP Modeling Configuration - 1/f Noise Measurement Diagram GPIB.
POWER PLANT USED IN TELECOM
43.35” (LENGTH OF INNER LIQUID HE RESERVIOR)  CONNECTION CHAMBER: FF 4.75”  FF: FLANGE-TO-FLANGE DISTANCE 10.45” TO 12.45” 6.35” TO 8.35” (JACK -2” TO.
Electrical Considerations Eargle, Ch. 8 (partial).
Installation and checkout of QBPM system Hardware to be installed –Install hardware in racks –Install CPU /SIS digitizers/VMIC 3122 analog digitizers/Digital.
Readout electronics for the MUV detectors R. Fantechi 28/3/2012.
Presentation of the DriveLab Board Opal-RT Real-time institute 2009.
BNCDB9 F Pin 1 – Center (Red)6 1 – Shield (Black)1 2 – Center (Yellow)8 2 – Shield (Black)3 D OMC Tip-Tilt Adaptor Cable BNC 1(1,6) BNC 2(3,8)
July LEReC Review July 2014 Low Energy RHIC electron Cooling Al Pendzick LEReC Civil Construction.
1 Discovery 2, Ch 4 Notes. 222 Cabling Standards Standards ensure that networks perform to expectations US—IEEE & ANSI/TIA/EIA Canada—CSA (Canadian Standards.
Optical Levers Layout and Cabling Yuta Michimura, Yuya Kuwahara Ando Group Department of Physics, University of Tokyo November 19, 2015.
Requirements concerning the interface linking the BPM to the quadrupole M. Wendt, S. Zorzetti.
1 4 PCB: LEFT TOP 115 channels, LEFT BOTTOM (115), RIGHT TOP (106), RIGHT BOTTOM (106). For LEFT TOP board 115 channels we have: 115 smd connectors (AMP.
QBPM System Installation Systems –Rack mount chassis –LO and CAL RF cable plant ( need 714Mhz from eels bedroom) –Down mix boxes –DC power cable plant.
IC-CAP Modeling Configuration Agilent Technologies November 01, 2005 Page 1 Agilent IC-CAP Modeling Configuration - Block Diagram ( GHz) E8364B.
KAGRA ISC Electrical Components Layout Yuta Michimura Ando Group Department of Physics, University of Tokyo December 8, 2015.
IC-CAP Modeling Configuration Agilent Technologies November 01, 2005 Page 1 Agilent IC-CAP Modeling Configuration - Block Diagram ( GHz) E8361A.
Summary Plans Content Module assembly at CERN and Dubna Readout DAQ Procurement Stacking Summary.
IC-CAP Modeling Configuration Agilent Technologies November 01, 2005 Page 1 Agilent IC-CAP Modeling Configuration - Block Diagram ( GHz) GPIB.
Cabling Policy for KAGRA ISC Yuta Michimura Ando Group Department of Physics, University of Tokyo March 14, 2016.
Local control sensors for iKAGRA payloads and perspective (Optical lever) Kazuhiro Agatsuma 2013/Dec./5 ELiTES meeting at Tokyo1.
IC-CAP Modeling Configuration Agilent Technologies November 01, 2005 Page 1 Agilent IC-CAP Modeling Configuration - Block Diagram ( GHz) E8364B.
Arm Length Stabilization Conceptual Configuration Yuta Michimura Department of Physics, University of Tokyo JGW-T November 14, 2016.
Results with the RPC system of OPERA and perspectives
Main Interferometer Subsystem
Chapter 2: Network Design Essentials
Main Interferometer Subsystem
Veto Readout Electronics-The Big Picture
DCS: Temperature Probes
Summary of iKAGRA Test Run Apr 11-25, 2016
Electronics and Cables around IMC Common Mode Servo Board
Chassis Power Regulator Board
TNC Male Clamp/Solder connector
BNC Female Bulkhead connector
SMA Male Right Angle connector
COVER Full production should arrive today
A photo sensor to monitor the motion of the recoil mass
RF cables calibration Matteo Volpi Thomas Geoffry Lucas
Interferometer Design for bKAGRA Phase 1 and Beyond
Pierluigi Paolucci - I.N.F.N. Naples
Arm Length Stabilization Conceptual Configuration
Arm Length Stabilization Conceptual Configuration
Multimedia Training Kit
Cartoon of the optical layout around IMC, IFI and IMM
Chassis Power Regulator Board
Interferometer Design for bKAGRA Phase 1 and Beyond
Summary of iKAGRA Test Run Mar 25-31, 2016
Coaxial Cables & Connectors
Interferometer Design for bKAGRA Phase 1 and Beyond
Report on ATF2 Third Project Meeting ATF2 Magnet Movers ATF2 Q-BPM Electronics Is SLAC ILC Instrumentation Group a good name?
Beam Propagation for bKAGRA Phase 1 with flat ETMs
Intensity Stabilization Servo Plan
RF and DC Cabling Policy for KAGRA ISC
RF Distribution Amplifier Top Assembly 1U (JGW-D )
Intensity Stabilization Servo Plan
Arm Length Stabilization Conceptual Configuration
KAGRA ISC Electrical Components Layout
Preparation for Installation at ESS
KAGRA ISC Electrical Components Layout
Presentation transcript:

RF and DC Cabling Policy for KAGRA ISC December 5, 2018 RF and DC Cabling Policy for KAGRA ISC Yuta Michimura Ando Group Department of Physics, University of Tokyo

Scope Summary of RF/DC cabling policy discussed at IOO and ISC mailing list, and Kamioka References: - JGW-D1100425 (electronics racks layout) - JGW-D1402984 (Cabling around PSL+IMC) - JGW-D1402986 (ISC rough layout and cabling) - JGW-D1403017 (Oplev rough layout and cabling) - JGW-D1403033 (cable racks layout)

RF Cabling Policy Use N-connectors for RF oscillators, RF distributors, and RF delay-line Use N-N low loss cables for table to rack, rack to rack cabling (Fujikura 12D-SFA-LITE) Use SMA-SMA flexible cable for cabling around a table, around a rack (LMR195?) N-SMA conversions will be done at patch panels Use N-SMA conversion connectors when there’s no patch panel for that cabling path Use SMA connectors for RFin/out in circuits Do not use BNC, LEMO (they make glitches), TNC, etc. (they add extra complexity) unless

DC Cabling Policy Use Dsub 9 pin male-female cables for table to rack, rack to rack cabling (may be should accept some exceptions to use single-ended instead; under discussion) Use TNC-TNC cables for cabling around a table, around a rack (BNC-BNC cables are accepted for monitor channels) Auxiliary slow channels should be concentrated to Dsub 9 pin at the table Use Dsub female for circuits which “send” signals (there are some exceptions, i.e. RF PD and RF QPD) Use Dsub male for circuits which “receive” signals (there are some exceptions) Dsub 15pin for QPDs Dsub 37pin for Binary Inputs/Outputs

Cabling Example Cabling example can be found in JGW-D1403111