The undergraduate authors would like to thank D. Bundy for providing technical support and manuscript comments, Dr. E. Leuthardt for advice throughout.

Slides:



Advertisements
Similar presentations
Thought Translation Device
Advertisements

Map of Essential Concepts Definition and levels of analysis
Presented By Qingwei Zhang Mu Li  To understand the definition and classification of brain-computer interaction  To explorer various non-invasive brain-
Attention and neglect.
BRAIN PLASTICITY AFTER SPINAL CORD INJURY CORTICAL REORGANIZATION AFTER CHRONIC SCI Mar Cortes Non-invasive Brain Stimulation and Human Motor Control Lab.
TMS-evoked EEG responses in symptomatic and recovered patients with mild traumatic brain injury Jussi Tallus 1, Pantelis Lioumis 2, Heikki Hämäläinen 3,
ANNUAL MEETING RERC on Technologies for Children with Orthopedic Disabilities NIDRR H133E Program Director: Gerald F. Harris, Ph.D., P.E. Program.
Nick Gomes BRAIN CONTROL INTERFACE (BCI) Richard Canton first discovers electrical signals on the surface of animal brains 1940s - Wilder Penfield.
Notes: Assignment 4 due Fri December, 10 th Extra Credit – answer questions on the form.
RESEARCHERS ARE DEVELOPING NEW METHODS OF TESTING THE OPERABILITY OF PROSTHETICS VIA THE BRAIN. Controlling a Computer With Thought.
IntroductionMethods Participants  7 adults with severe motor impairment.  9 adults with no motor impairment.  Each participant was asked to utilize.
Brain-computer interfaces: classifying imaginary movements and effects of tDCS Iulia Comşa MRes Computational Neuroscience and Cognitive Robotics Supervisors:
1 1 MPI for Biological Cybernetics 2 Stanford University 3 Werner Reichardt Centre for Integrative Neuroscience Eberhard Karls University Tuebingen Epidural.
Brain-Computer Interfaces for Communication in Paralysis: A Clinical Experimental Approach By Adil Mehmood Khan.
Presented by: Vanessa Wong Corbetta et al..  Inability to pay attention to space  Most common cause is stroke  Caused by focal injury to temporoparietal.
HST 583 fMRI DATA ANALYSIS AND ACQUISITION Neural Signal Processing for Functional Neuroimaging Emery N. Brown Neuroscience Statistics Research Laboratory.
Brain-Computer Interface - BrainGate Chip Hillary Grimes III Homework 6 COMP 4640.
A commonly used feature to discriminate between hand and foot movements is the variance of the EEG signal at certain electrodes. To this end, one calculates.
CSE 490i: Design in Neurobotics Yoky Matsuoka (instructor) Lecture: TTH 10:30-11:20 EEB 003 Labs: TTH 11:30-1:20 CSE 003E.
A brain-machine interface instructed by direct intracortical microstimulation Joseph E. O’Doherty, Mikhail A. Lebedev, Timothy L. Hanson, Nathan A. Fitzsimmons.
BCI Systems Brendan Allison, Ph.D. Institute for Automation University of Bremen 6 November, 2008.
By Omar Nada & Sina Firouzi. Introduction What is it A communication channel between brain and electronic device Computer to brain/Brain to computer Why.
NeuroPhone : Brain-Mobile Phone Interface using a wireless EEG Headset Ilho nam.
ERP DATA ACQUISITION & PREPROCESSING EEG Acquisition: 256 scalp sites; vertex recording reference (Geodesic Sensor Net)..01 Hz to 100 Hz analogue filter;
Cortical activity changes among stroke patients following robotic upper limb rehabilitation as measured by EEG during reaching movements Pollet, S 1, Burridge,
Presenter : Jung-Ting Jin Adviser : Dr. Shih-Chung Chen Chairman : Dr. Hung-Chi Yang Date : December 31, 2014 BCI2000 : A General- Purpose Brain-Computer.
1. 2 Abstract - Two experimental paradigms : - EEG-based system that is able to detect high mental workload in drivers operating under real traffic condition.
Kasey Jones TELEKINESIS: MIND OVER MECHANICS. THE DISCOVERY Thanks to researchers from the Minnesota College of Science and Engineering, the theme of.
Motor control, motor Learning and recovery of function
Brain-Computer-Interface for Stress Detection Hassan Farooq, Ilona Wong Supervisor: Steve Mann Administrator: Cristiana Amza Section 8 Collecting Brainwave.
Signal and noise. Tiny signals in lots of noise RestPressing hands Absolute difference % signal difference.
BRAINGATE NEURAL- INTERFACE SYSTEM BY
Graz-Brain-Computer Interface: State of Research By Hyun Sang Suh.
Evaluation of a Closed-Loop BCI-FES System on Recovery of Upper Extremity Function Based on Functionality Post Stroke: A Case Series Angela Gille, OTS.
ICRA2009 Evaluation of a robot as embodied interface for Brain Computer Interface systems E. Menegatti, L. Tonin Intelligent Autonomous System Laboratory.
Md.Kausher ahmed Electrical department. Biomedical engineering Code:6875.
Functional Brain Signal Processing: EEG & fMRI Lesson 4
 A direct communication pathway between the brain and an external device.  Directed at assisting, augmenting, or repairing human cognitive or sensory-motor.
Neurochips and Neural Telemedicine Jaideep Mavoori University of Washington (currently at Neurovista) Collaborators: Andy Jackson +, Eb Fetz (Biophysics.
Gary O’ Donoghue Electronic & Computer Engineering, National University of Ireland, Galway Final Year Project A small number of consumer electronics.
BCI-based Robot Rehabilitation Framework for Stroke Patients M. Gomez-Rodriguez 1,2 J. Peters 1 J.. Hill 1 A. Gharabaghi 3 B. Schölkopf 1 M.. Grosse-Wentrup.
EEG-Based Communication and Control: Short-Term Role Feedback Present by: Yu Yuan-Chu Dennis J. Mcfarland, Lynn M. McCane, and J. R. Wolpaw.
Automatic online control of motor adjustments -P NANDHA KUMAR.
作者:Ali Bulent Usakli and Serkan Gurkan
Analysis of Movement Related EEG Signal by Time Dependent Fractal Dimension and Neural Network for Brain Computer Interface NI NI SOE (D3) Fractal and.
Workshop on direct brain/computer interface & control Febo Cincotti Fondazione Santa Lucia IRCCS Brussels, August 2, 2006.
A High-Performance Brain- Computer Interface
IPSIHAND AN EEG BASED BRAIN COMPUTER INTERFACE FOR MOTOR REHABILITATION.
BRAIN GATE TECHNOLOGY.. Brain gate is a brain implant system developed by the bio-tech company Cyberkinetics in 2003 in conjunction with the Department.
introduction Brain driven car which would be of great help to the physically disabled people. These cars will rely only on what the individual is thinking.
A Cortico-Muscular-Coupling based Single-Trial Detection in EEG-EMG based BCI for Personalized Neuro-Rehabilitation of Stroke Patients 1. Introduction.
Oregon Health & Science University
SIE 515 Brain-Computer Interfaces (BCI) and Sensory Substitution
References and Related Work
Repetitive Transcranial Magnetic Stimulation Facilitates Effective Gait Rehabilitation in Patients with Traumatic Brain Injury Forshee, C. MPT CBIS, Foreman,
Brain operated wheelchair
[Ran Manor and Amir B.Geva] Yehu Sapir Outlines Review
When to engage in interaction – and how
Fabien LOTTE, Cuntai GUAN Brain-Computer Interfaces laboratory
Major Project Presentation Phase - I
Device for Acute Rehabilitation of the Paretic Hand After Stroke
Toward More Versatile and Intuitive Cortical Brain–Machine Interfaces
An Exploration of BCI2000 Utility Across Multiple Sessions
Repetitive Transcranial Magnetic Stimulation May Benefit Motor Recovery After Incomplete Spinal Cord Injury: A Case Study Foreman, J., Masel, B. MD Transitional.
Brain-Machine Interfaces beyond Neuroprosthetics
Machine Learning for Visual Scene Classification with EEG Data
Brain-Computer Interfaces in Medicine
Volume 34, Issue 5, Pages (May 2002)
BCI Research at the ISRC, University of Ulster N. Ireland, UK
Spectra superimposed on the brain over each electrode for patient JC during a hand movement task (red curves) and resting interval (blue curves). Spectra.
Presentation transcript:

The undergraduate authors would like to thank D. Bundy for providing technical support and manuscript comments, Dr. E. Leuthardt for advice throughout the work, and Dr. A. Nehorai for his support as well. This project supported in part by The National Collegiate Inventors and Innovators Alliance, The Washington University School of Engineering, and Emotiv Systems. Combining the discovery of signals in contralesional hemisphere, electronics, and advances in rehabilitation, IpsiHand offers a new rehabilitation option for stroke and TBI survivors. IpsiHand was able to process EEG signals for real-time hand control with accuracy consistent with previous studies [8] and theoretical ROC analysis. Combining BCIs and orthotic devices induces neural plasticity and improves motor function [8]. Furthermore, IpsiHand therapy is unhampered by the severity of neural pathway injury by circumventing the injury. Compared to other devices, IpsiHand facilitates plasticity most directly, is cheaper and more portable. Future Directions: We plan improvements in portability and signal processing. Portability Goals: Currently, a laptop processes the EEG signals used for orthosis movement. We plan to miniaturize the processing to a micro- computer for portability, allowing patients to even use the device as a replacement for normal hand function in daily life. Signal Processing Goals: Expand the systems ability to adapt to spatially non-stationary EEG signals. Possibilities include adaptive feature selection and adaptive spatial reference selection. Remove muscular and other artifacts with spatial and temporal filtering. This is essential for device performance outside of a research setting. Artifact sources include eye blinks, EMG, ECG, and breathing. Build real-time feature selection to eliminate need for screening procedure and improve user friendliness. Improve control signal normalization and adaptation through least mean squares algorithm and linear regression techniques. An Emotiv EPOC TM EEG headset records EEG signals from the scalp with 14 channels. The headset aligns, bandpass filters, and digitizes the signal at 128 Hz and transmits wirelessly to a laptop. IpsiHand: An EEG-based Brain Computer Interface for Rehabilitation and Restoration of Hand Control following Stroke and Traumatic Brain Injury Using Ipsilateral Cortical Physiology Sam Fok, Raphael Schwartz, Mark Wronkiewicz, Charles Holmes, Jessica Zhang, Thane Somers, David Bundy, Dr. Eric Leuthardt Washington University in St. Louis AbstractMethodsResults Discussion Stroke and traumatic brain injury (TBI) cause long-term, unilateral loss of motor control due to brain damage on the opposing (contralateral) side of the body. Conventional therapies are ineffective at restoring function in about half affected. Brain computer interfaces (BCIs) show promise for rehabilitation but remain primarily restricted to the research stage. Furthermore, traditional BCIs cannot work if areas such as M1 are damaged. We present a novel BCI, IpsiHand, which circumvents signal sourcing issues in an injured brain as well as risk associated with invasive recordings. IpsiHand uses electroencephalography (EEG) to record novel motor intent signals and control a powered hand orthosis, which allows the undamaged hemisphere to control both hands. Through sensory and proprioceptive feedback and neural plasticity, IpsiHand can strengthen ipsilateral neural pathways. Introduction References Stroke and TBI combined are the leading cause of disability in the US, with around a million cases annually. Half report trouble with hand movement, and conventional physical therapy produces little improvement after 3 months post injury [1]. Therapies requiring the patient to actively control their impaired limb are most likely to induce reorganization of neural pathways and improving control but require intensive interaction between the patient and practitioner [2]. BCIs promise new, more effective motor therapies. They are traditionally applied in cases where central nervous signals are cut off from their destination by injury. Electrical signals are recorded from the brain to circumvent injuries and control devices to actuate a target limb, which recouples intent to move and movement [3]. Despite promise, conventional BCIs cannot be applied to cases of brain injury where damaged primary motor cortex contralateral to the affected limb produces no signals. However, recent study found distinct cortical physiology associated with ipsilateral, contralesional hand and limb movement in regions distinct and separable from the primary motor cortex [4]. These signals exist in cortex anterior to ipsilateral primary motor cortex at frequencies below 40Hz [5]. We used a non-invasive EEG consumer headset to record from cortex and control an orthosis that opens and closes a subjects hand. As the least invasive recording technique, EEG is most practical for immediate application in the clinic. IpsiHand demonstrates the synthesis of neurophysiology, consumer electronics, and signal processing to develop new devices for more effective therapies. Implementation of this design constitutes a fundamentally new approach to restoring function in stroke and TBI survivors. Synchronous neuronal firing over large areas of the cortex are recorded from the scalp and processed onboard a laptop. The signal is filtered to generate a control signal, which is then sent to a linear actuator fitted to an orthosis controlling the patients finger closure. IpsiHand was tested with three healthy subjects to verify the ability to use non-conventional signals from cortex on one side of the brain to control a hand on the same side of the body. We found that: 1. Hand movement correlates with ipsilateral signals. 2. IpsiHand can use EEG signals to move the hand. [1] HS-Jorgensen, et_al,-"Outcome and time course of recovery in stroke: Part II: Timecourse of recovery. The Copenhagen Stroke Study,"Archives of Physical Medicine and Rehabilitation, [2] G Schalk, D McFarland, T Hinterberger, N Bribaumer, and J Wolpaw, "BCI2000: a general purpose brain computer interface (BCI) system,IEEE Transactions on Biomedical Engineering, pp , [3] D Broetz and et al, "Combination of brain-computer interface training and goal-directed physical therpy in chronic stroke: A case report," J Neurorehab and Neural Repair, pp , [4] Kimberly J Wineski et al., "Unique cortical physiology associated with ipsilateral hand movements and neuroprosthetic implications, Stroke, pp , [5] KJ_Wineski et. al., "Unique cortical physiology associated with ipsilateral hand movements and neuroprosthetic implications, Stroke, [6] DJ_McFarland, et. al, "Spatial filter selection for EEG-based communication, Electroencephalography and Clinical Neurophysiology, vol. 103, [7] Ernst Niedermeyer and Fernando Lopes da Silva, Electroencephalography: basic principles, clinical applications, and related fields.: Lippincott Williams & Wilkins, [8] DJ_McFarland, et. al, "Electroencephalographic (EEG) control of three-dimensional movement," J. Neural Eng., vol. 7, Acknowledgements Signal Processing and Control Signal Acquisition Mechanical Orthosis A Becker Oregon Talon TM prefabricated orthosis, designed to couple wrist motion to hand closure, was fitted with a powered linear actuator (Firgelli Miniature Linear Motion Series L16), controlled through our LabView algorithm. The orthosis size is adjustable, which is key in a clinical setting with a variety of patients. To mechanically prevent hyperextension or hyperflexion of the hand, the range of actuator motion is mapped only onto the natural range of finger joint rotation. Left: Correlation colormap between left hand movement and rest per electrode and per frequency bin. Electrodes named according to the EEG system(Right) [7]. Bins with high correlation are good candidates for control signals. Clusters (dotted red circles) of high correlation in ipsilateral cortex noted around the 12Hz bins in F3 through P7 and also in channel F3 around the 22Hz bin. Window Length 2.6 Seconds 2.0 Seconds 1.0 Seconds 0.5 Seconds Random Guess Window Length (Seconds)Accuracy of Classification % % % % Classification accuracy using best threshold as determined by ROC analysis per window length. In actual trials, through 10 sets of trials with non-impaired individuals we achieved an 81.3% success rate for the 1D cursor task and orthosis using a 0.5s window. Note that this is slightly higher than predicted by ROC analysis. Top: Left: Spatial map of L.hand vs. rest correlations per channel at 12Hz. Note correlations present across frontal cortex. Top: Right: Spatial map of L.hand vs. rest correlations per channel at 22Hz. Note correlation only present unilaterally in channel F3. Bottom: Left: Raw spectrum of channel F3 shows difference in power around 12 and 22Hz bins during L.hand and rest conditions. Bottom: Right: ROC curves shows classification performance using varying window lengths and thresholds. Note that longer window have higher performance but also increase the system latency. The features identified during screening were used to modulate orthosis closure and 1D cursor movement. The subject was tasked with moving the cursor to a target randomly located at either the left or right side of the screen (below). Screening Results Online Performance Results