Noise in TOB modules and sensor quality

Slides:



Advertisements
Similar presentations
TEC X5 Setup (1) 1 Front + 1 Back petal, fully equipped (28 modules F.P modules B.P. + AOH + DOHM) Petal assembly IPN-Lyon (F.P.), RWTH-Aachen I.
Advertisements

US Production Report - September 4, Incandela 1 US Production Report CMS Tracker Steering Committee 4 September 2003 J. Incandela University of.
CMS week – December 8-12, TOB sensor quality Regina Demina University of Rochester.
Recent TOB Developments First LT failure and Stereo Module Status J. Incandela With slides provided by E. Chabalina, A. Affolder, Dean White.
1 Module produced with low R int sensors-Anthony AffolderSensor Meeting, Feb 11, 2004 Modules Produced With Low R int Sensors Anthony Affolder UCSB.
1 CMS week 15/03/05, Module Production Meeting, Dean White - UCSB Status of Sensor Bias Connection Dean White For the US CMS Group.
Slide 1US silicon group meeting 5/6/2003 Hybrid Testing Status 10 new hybrids brought by Lenny all tested à 9 tested with no flaws à 1 had 1 chip + 1 wirebond.
4/25/2006 Puneeth Kalavase, UC, Santa Barbara On behalf of US Tracker Outer Barrel group Construction and Testing of CMS “Rods”
1 Hybrid & Module Testing Status Week of 6/6-6/10.
Finding ST Sensors that cause CMN: A Follow up to TSC Meeting N. 215 Prof. J. Incandela UC Santa Barbara US CMS Tracker Project Leader Tracker Steering.
1 CMN Problem Review-Anthony AffolderTPO, December 11, 2003 Review of CMN Problem/Studies Ariella requested me to review the current understanding of the.
1 US Testing Status-Anthony AffolderModule Testing Meeting, Dec. 11, 2003 Update of US Testing Status Anthony Affolder On behalf of the US testing group.
1 US Testing Update-Anthony AffolderTracker Meeting, Feb 10, 2004 US Module Testing Update Anthony Affolder (On behalf of the US testing group) Update.
Identifying anomalous strips David Stuart, Noah Rubinstein University of California, Santa Barbara June 18,
Guido_Tonelli / CMS_TSC / 5 February Time stability of ST sensors The problem The sensors re-measuring campaign Failure analysis Conclusions.
Fermilab PMG - Results from module testing - April 9, 2004 – E.Chabalina (UIC) 1 Results from module testing E.Chabalina University of Illinois (Chicago)
On behalf of the US TOB testing group
Hybrid & Module Testing Status
Update of US Testing Status
US Module Production Status
Review of CMN Problem/Studies
UCSB Testing 3 Stereo Modules Tested 1 SS6 Module Tested
Results from module testing
Unexpected Failures of Modules on Rods
Overview Time structure of leakage currents
US Module Production Quality
Recent TOB Developments
Module Failures on RODs
Module Failures on RODs
On behalf of the US TOB testing group
Discoloration of Passitivation
Module production in Italy
US Testing Update Anthony Affolder (On behalf of the US testing group)
The measurement set-up
What we learned today Made test bonds on Al plate using bonding parameters of channel and bias bonds Inspected 10 bonds of each type None of them showed.
Damage under UCSB bias bonds
Hybrid Testing Status 10 new hybrids brought by Lenny all tested
UCSB Qualification Module Grading
Hybrid Status/Deliveries
Sensor probing (Summary)
First UCSB TEC Module (Pictures)
Hybrid & Module Testing Status
Passitivation Location
Modules Produced With Low Rint Sensors
FNAL Hybrid Testing Status
Noise in TOB modules and sensor quality
Production Status 39 modules produced
Status of 44 ARCS tested TOB modules, June 24, 2004
Is Increased Bias Current and CMN Correlated?
Full list of devices of May09
TOB Module Production Overview and Plan
FNAL module testing summary
Hybrid & Module Testing Status
Hybrid & Module Testing Status
Recent TOB Developments
Hybrid & Module Testing Status
Hybrid & Module Testing Status
Recent TOB Developments
Module Failures on Rods
Module Testing Status Week of 3/14-3/18.
Hybrid & Module Testing Status
FNAL Hybrid Testing Status
Hybrid & Module Testing Status
Hybrid & Module Testing Status
Hybrid & Module Testing Status
Hybrid & Module Testing Status
Status of Hamamatsu Silicon Sensors
FNAL Hybrid Testing Status
FNAL Hybrid Testing Status
FNAL Hybrid Testing Status
Presentation transcript:

Noise in TOB modules and sensor quality Regina Demina University of Rochester

Module 876 Of the 16 modules tested at UCSB, Observed peculiarity in module testing : Noise on some channels increases with bias voltage. Micro discharge effect (also seen in D0 sensors delivered by Micron)

Module 876 Defects in channels 278 and 279. Not found in sensor probing

Module 876

Module 877 Defect (scratch) in channel 333. Not found in sensor probing

Module 877

Module 878 Defect in channel 377. Not found in sensor probing

Module 878

Module 880 Strip 91 a known pinhole in the first sensor.

Module 880

Module 868 Mid-sensor opens in channels 69-71 in the 1st sensor

Module 868

Module 883 Defect in channel 166. Not found in sensor probing

Module 883 Scratch in channel 316

Module 883

Module 872 Defect in channel 303. Not found in sensor probing

Module 872 Scratch in channel 344. Not found in sensor probing

Module 872

Summary Module # Comments 875 Channel 384 has high noise, but no lithography error present. NOT SEEN IN SENSOR PROBING 874 Found High Istrip channel in 2nd sensor (294) causes noise. Remove 293-295 between sensors and module is good 873 Micro-discharge at channel 14 at 270 V (need to pluck 10-18 to remove cmn). No obvious sensor damage. NOT SEEN IN SENSOR PROBING 872 4 channels with noise increase with HV. 3 have obvious lithographic error. NONE SEEN IN SENSOR PROBING 871 Micro-discharge at channel 181 at 300 V (need to pluck 175-187 to remove cmn). No obvious sensor damage. NOT SEEN IN SENSOR PROBING 870 Good 883 Channel 166 has increasing noise with HV. Has lithographic error (see picture). NOT SEEN IN SENSOR PROBING 882 Good

Summary Module # Comments 881 Micro-discharge at channels 438-440 (need to pull 434-444 to stop high cmn). Channels start discharging at 0V and get worse 869 Micro-discharge at channels 29-30 (need to pull 24-36 to stop high cmn) at 400 V 868 3 mid-sensor opens, lithographic error (see photo). NOT FOUND IN SENSOR PROBING 880 NO PROBLEMS 879 NO PROBLEMS 878 Channel 377 has increasing noise vs bias. Lithographic error found in second sensor (see picture). NOT SEEN IN SENSOR PROBING 877 Channel 334 has slightly higher noise at 550 V. Lithographic error found in first sensor. (See picture.) NOT FOUND IN SENSOR PROBING 876 Channels 278-279 have increasing noise vs. bias voltage. Sensor lithographic error found on both channels (see picture) NOT FOUND IN SENSOR PROBING

Summary Out of 16 modules built 11 show some signs of micro discharge. Total number of noisy strips – 17 Number of strips with high I strip – 1 Number of strips with obvious lithographic error – 8 Opens - 3

Module 875

Module 874

Module 873

Module 871

Module 870

Module 882

Module 881

Module 869

Module 879