Confidential – Training Information Slide 1 C-Pulse® Implantable Counterpulsation Pump Advanced Programmer Operation LBL 02759-E Advanced Programmer Operation.

Slides:



Advertisements
Similar presentations
Time Sheet Training Press the F5 Key to view the Presentation. It may be helpful to have a printed copy of this slide presentation for the practice sessions.
Advertisements

Module 3: Block 3 Call Management
Module 1: BLOCK 1 / MAIN MENU
TI – 83 Plus1 A Quick Reference Presentation for AMSTI Year 1 Training.
1. XP 2 * The Web is a collection of files that reside on computers, called Web servers. * Web servers are connected to each other through the Internet.
Follow the instruction to install the PC Suite from the SD card: 1.Go to the settings -> SD Card & phone storage -> Enable the mass storage only mode 2.Connect.
NWCA OPC Coaches Tutorial Roster, Schedules, Weigh-Ins, Results, and Reports.
Cardiac Cycle The two atria contract at the same time, then they relax while the two ventricles simultaneously contract. The contraction phase of the ventricle.
Tutorial 9 – Creating On-Screen Forms Using Advanced Table Techniques
XP New Perspectives on Microsoft Office Word 2003 Tutorial 7 1 Microsoft Office Word 2003 Tutorial 7 – Collaborating With Others and Creating Web Pages.
State of New Jersey Department of Health and Senior Services Patient Safety Reporting System Module 2 – New Event Entry.
Determine Eligibility Chapter 4. Determine Eligibility 4-2 Objectives Search for Customer on database Enter application signed date and eligibility determination.
Child Health Reporting System (CHRS) How to Submit VHSS Data
Microsoft®.
07/30/ ODE, Office for Child Nutrition Completing Commodity Orders.
Welcome to Access Online for State of Iowa Cardholders.
1 How to Enter Time. 2 Select: Log In Once logged in, Select: Employees.
3/17 Dividend Street, Mansfield, 4122, Queensland, Australia phone: web: The SuperCycler A Software.
ABC Technology Project
SphygmoCor Cardiovascular Management Suite Software
School of Geography FACULTY OF ENVIRONMENT Working with Tables 1.
© Paradigm Publishing, Inc Access 2010 Level 1 Unit 1Creating Tables and Queries Chapter 2Creating Relationships between Tables.
Microsoft Office Illustrated Fundamentals Unit K: Working with Data.
Microsoft Access.
1 of 27 DA1241 Archive Companies Last updated: March-2004 DA1241 Archive Companies.
Introducing WebDewey 2.0. Introducing WebDewey 2.0.
EPOCH 1000 Series Software Update New Features - March 2010.
ECATS RCCA CAMP PROCESS ENHANCEMENTS
XP New Perspectives on Introducing Microsoft Office 2003 Tutorial 1 1 Using Common Features of Microsoft Office 2003 Tutorial 1.
Microsoft Office Illustrated Fundamentals Unit C: Getting Started with Unit C: Getting Started with Microsoft Office 2010 Microsoft Office 2010.
Chapter 11: The X Window System Guide To UNIX Using Linux Third Edition.
Nortel Contact Center: An Overview
Benchmark Series Microsoft Excel 2013 Level 2
Services Course Outlook Live Participant Guide.
Working with Travel Allowances (Per Diem)
CREATING A PAYMENT REQUEST FOR A NEW VENDOR
The world leader in serving science TQ ANALYST SOFTWARE Putting your applications on target.
 Copyright I/O International, 2013 Visit us at: A Feature Within from Item Class User Friendly Maintenance  Copyright.
OCFS Data Warehouse Basic Training
4 Oracle Data Integrator First Project – Simple Transformations: One source, one target 3-1.
© 2012 National Heart Foundation of Australia. Slide 2.
1 How Do I Order From.decimal? Rev 05/04/09 This instructional training document may be updated at anytime. Please visit and check the.
Using the camera and the wireless microphone Howard Goldbaum 9/17/2012.
DP-IR Detecto-Pak Infrared
25 seconds left…...
XP New Perspectives on Browser and Basics Tutorial 1 1 Browser and Basics Tutorial 1.
School Census Summer 2011 Headlines Version Jim Haywood Product Manager for Statutory Returns.
Reporting Serious Incidents in TFACTS
Travel 1: Travel Authorization. Welcome to Training! Why PeopleSoft? – PeopleSoft will help UTEP to grow. What’s Your Part? – We need your skills and.
Bump-test and Calibration Procedures
Module 12 WSP quality assurance tool 1. Module 12 WSP quality assurance tool Session structure Introduction About the tool Using the tool Supporting materials.
ACD Training.
Installing Windows XP Professional Using Attended Installation Slide 1 of 30Session 8 Ver. 1.0 CompTIA A+ Certification: A Comprehensive Approach for all.
Section 1: Process to create EAS Interface File  DoD Batch and Timecard Status Report  DoD Employee Missing Payroll Data Report  Distribute Labor Cost.
Import Tracking and Landed Cost Processing An Enhancement For AS/400 DMAS from  Copyright I/O International, 2001, 2005, 2008, 2012 Skip Intro Version.
Exony Reports User Guide Estimated Timings:
CFS 9.2 Upgrade Forum 1. Navigation Changes Main Menu Recently Used Re-organized Menu Cascading Menus Breadcrumbs Autocomplete 2.
Benchmark Series Microsoft Excel 2013 Level 2
X-Call Version V3.0 User Guide
Instructor Terry Wiseth
ACap™ Confirm. ACap™ Confirm ACap™ Confirm Benefits Automatic algorithm to adjust the atrial pacing amplitude to address changing atrial thresholds.
Chapter 11 - Monitoring Server Performance1 Ch. 11 – Monitoring Server Performance MIS 431 – created Spring 2006.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
2nd Edition / 2002 The information contained on the following pages, in conjunction with the slides provided at the back of this binder, complete the Introduction.
SMART Response Initial Set-up: Windows PC Teacher and Class Set-up Creating a Quiz, Test, or Survey Delivering an Assessment Reports Additional Question.
Self Guided Tour of TagMate™QC Display Tag DATA Tag Data: PRINT TagMate™QC SETUP Display STATS Tags: START and READ SEND All Data to PC Additional Capabilities.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
*** CONFIDENTIAL *** © Toshiba Corporation 2008 Confidential Creating Report Templates.
Capnography The EMS Version By: Ryan Felish. Why Capnography? Capnography – the measurement of carbon dioxide (CO2) in exhaled breath. Capnography provides.
Digital Chart Recorder Operation
Presentation transcript:

Confidential – Training Information Slide 1 C-Pulse® Implantable Counterpulsation Pump Advanced Programmer Operation LBL E Advanced Programmer Operation Investigational Device. Limited by federal law to investigational use only. For Clinical Trial Use Only Investigational Device To Be Used by Qualified Investigators Only Instrument de recherché Réservé uniquement à lusage de chercher compétent

Confidential – Training Information Slide 2 Programmer Operating Screen Real- time data area Immediate adjustments area Menus Current Pt ID Current rhythm stability classification Current parameter set Changes to these parameters take effect immediately – similar to IABP.

Confidential – Training Information Slide 3 Immediate adjustments area Infrared Connection Status Augmentation Mode Change Inflation Volume adjustment Deflation timing adjustment (each click changes time by 2 msec, grey indicates at limit) Connect/disconnect from driver (connection also requires push and hold of the Confirm button on Driver) Enable/Disable Counterpulsation Inflation timing adjustment (each click changes time by 5 msec, grey indicates at limit) Changes to these parameters take effect immediately – similar to IABP.

Confidential – Training Information Slide 4 Immediate adjustments area Current Inflation Hold Pressure Current Heart Rate Capture a screen shot of a transduced aortic pressure wave form by partially inflating the cuff for one cardiac cycle; this can then be used for measuring or adjusting timing Start/Stop real time data

Confidential – Training Information Slide 5 File menu Save Waveform saves an image of the current real- time data waveforms to a file Open Waveform displays a previously saved waveform file Save Driver Data saves all current driver data (including current parameters, status, and event logs) to file Open Driver Data displays a summary of a previously saved driver data file Patient Information sets the Patient ID written into the driver and used to tag all driver reports. Start Recording/Stop Recording begins/ends background recording to a file of all displayed real- time data. Recording continues indefinitely, but is paused if the display is paused. Shutdown Programmer exits from the programmer application – if driver operating on temporary parameters, it reverts to its permanent parameters

Confidential – Training Information Slide 6 Control menu Clear Event Log clears the event log after saving a copy of the current event log to file Set Driver Time adjusts the date and time stored in the driver for inclusion in event logs

Confidential – Training Information Slide 7 Parameters menu Allows programming of a range of detailed driver parameters – changes take effect when the Update button is pressed on the selected parameter screen Revert to Saved – if the Driver is currently operating from temporary parameters this will cause it to immediately discard the temporary parameters and revert to its permanently programmed parameters

Confidential – Training Information Slide 8 Display menu Zoom selects time base for real- time data between a screen width of 20 sec and a screen width of 1.25 sec Display Waveform selects which waveforms are displayed Event Log shows the current contents of the event log Driver Battery Information displays details about the battery pack currently in the driver such as state of charge Options sets the various options including the default selections for Zoom and Display Waveforms.

Confidential – Training Information Slide 9 Display/Event Log Shows any alarms that have occurred

Confidential – Training Information Slide 10 Display/Event Log Filter allows selection of type of events to be displayed

Confidential – Training Information Slide 11 Tools menu Provides capability for performing measurements on real-time data waveforms.

Confidential – Training Information Slide 12 Tools/Measure Measure ECG Amplitude (mV) Measure Time (sec) Measure Gas Pressure (mmHg) Menu allows selection of 3 measurement tools

Confidential – Training Information Slide 13 Help menu About shows information about the current driver and programmer including software and hardware version information

Confidential – Training Information Slide 14 Programming Operating Parameters Parameters can be changed using: The Immediate Adjustments area on the main screen Individual screens under the parameters menu, followed by pressing Update on the parameter screen All parameter changes are initially only temporary and will be discarded if: The driver is turned off The programmer is turned off The programmer/driver link is broken for more than about 15 seconds Revert To Saved is selected from the Parameters menu Parameters changes can be made permanent by pressing the Confirm button on the driver Confirm Button

Confidential – Training Information Slide 15 Optimizing Inflation Volume Increase Target Inflation Volume while monitoring Inflation Hold Pressure (IHP) – aim for IHP 0-20 mmHg above mean arterial pressure Monitor Inflation Hold Pressure relative to blood pressure – IHP will jump when beyond sweet-spot – reduce TIV by 1-2 cc. Volume changes may start a volume calibration cycle – wait until end of cycle before assessing IHP.

Confidential – Training Information Slide 16 Adjusting Inflation Timing Transduced aortic pressure waveform; with systolic period visible Use Partial Hold at 1:1 (with zoom at 5 sec or more) to see inflation and deflation timing at current settings Adjust timing using arrows at right (1 click = 5 msec); screen will show previous timing (grey line) and new inflation timing (green line) Repeat Partial Hold and adjustment as required Confirm timing using arterial line, carotid doppler, plethysmography, etc Deflation timing at time of Partial Hold (red line) Inflation timing at time of Partial Hold (grey line) Current (adjusted) inflation timing (green line)

Confidential – Training Information Slide 17 Adjusting Inflation Timing Regular vs Irregular Rhythms If rhythm is regular: Driver uses regular timing params Time from dichotic notch to start of inflation should be approx 60 msec (subject to optimization) If rhythm is irregular: Driver uses later irregular timing Repeat measurement several times Time from dichotic notch to start of inflation should be minimum approx 60 msec and average approx 100 msec (subject to optimization) Minimum is likely to be following a long interval (longer fill time is followed by higher ejection volume and ejection time) Time from DN to start of inflation (here 64 msec)

Confidential – Training Information Slide 18 Fine Tuning Inflation Timing Use Arterial line, Carotid Doppler, Plethysmography, etc, or Partial Hold to observe timing Measure R-wave to end-of- systole interval time at two heart rates Enter 2 points on Inflation graph into Inflation parameter settings – or drag points on Inflation Timing graph Go to basic screen and re- adjust timing with C-Pulse in 1:1 mode Use Arterial line, Carotid Doppler, Plethysmography, etc, to observe diastolic augmentation Adjust Slew Rate so that augmentation peak is similar to systolic peak

Confidential – Training Information Slide 19 Confirming Deflation Timing Latency at Implant With delay set to ZERO, latency should be at least 120 msec to ensure ability to adequately unload LV Use partial hold at 1:1 (with zoom setting at 5 sec or more) to check latency between ECG and start of systole (tools/measure time) At implant: Notes: 1. Latency greater than 220 msec may result if leads on RV and LBBB present and may lead to problems with inflation timing 2. Intermittent V-paced R waves may introduce variability of time from R-wave to beginning of systole – preferentially placing leads on LV reduces this risk

Confidential – Training Information Slide 20 Optimizing Deflation Timing During implant, and when arterial line is available, set counterpulsation to 1:2 and use arrows on right side of programmer screen (1 click = 2 msec) to adjust deflation timing for optimal unloading effect If arterial line not available (eg at follow-up), set counterpulsation to 1:1, observe duration of deflation on solenoid trace, use partial hold to determine time to start of systole, and adjust deflation delay accordingly. Very late deflation may be represented by a ski-jump effect at the end of the Cuff inflation hold pressure wave-form. Confirm timing (particularly deflation not late) using carotid doppler, plethysmography, etc. Late deflation may present as little or no unloading, or even reverse unloading. If required, deflation timing can be fine tuned using graph method similar to inflation timing Warning: Care is required if adjusting timing parameters while the patient has an irregular rhythm – deflation timing will be later when the patient reverts to a regular rhythm

Confidential – Training Information Slide 21 Adjusting ECG detection parameters Variable R-wave detection thresholdSensitivity setting changes this proportion (high sensitivity = low proportion) Minimum Threshold sets this lower limit The ECG detection algorithm automatically adjusts for ECG amplitude – default parameters are usually OK. If problems are encountered the following parameters can be adjusted:

Confidential – Training Information Slide 22 Adjusting ECG detection parameters Sensitivity controls how fast the threshold can change between beats. A higher setting means that detection is more sensitive to a low amplitude R- wave which follows a high amplitude one. However it also makes it more sensitive to T-waves and noise. Minimum Threshold controls the minimum threshold level. This should be set higher than all unwanted signals (eg noise) but well below the R-wave amplitude. Slope adjusts the sensitivity to slow moving signals – changing to Low makes it more sensitive to slow R-waves (eg wide QRS) but needs care as it is also more sensitive to T-waves. Post-Pace Refractory Period is the period after a pace detect during which following artifacts are ignored. Try increasing if problems are encountered with interference from high amplitude pacing pulses, but ensure R-waves are not missed.

Confidential – Training Information Slide 23 Adjusting ECG detection parameters Clinical Scenarios Ectopics significantly different in R-wave amplitude to intrinsic beats: Driver may intermittently miss lower amplitude R-waves Increase Sensitivity, but ensure not sensing T-waves or noise Paced beats significantly different in R-wave amplitude to intrinsic beats: Driver may intermittently miss lower amplitude R-waves Increase Sensitivity, but ensure not sensing T-waves or noise R-wave amplitude decreases significantly after implant: If amplitude of R-waves drops below minimum threshold, sensing may become intermittent or lost Reduce Minimum Threshold, but ensure not sensing T-waves or noise

Confidential – Training Information Slide 24 Setting Heart Rate Monitoring Parameters Minimum Rate and Maximum Rate set heart rate limits for counterpulsation. Sustained heart rates outside this range will cause the driver to alarm. R-R Interval Count controls the number of beats used for heart rate averaging. R-R Stability Threshold sets the heart rate variability which causes the driver to change to its (more conservative) irregular rhythm timing.

Confidential – Training Information Slide 25 Setting Other Parameters Cuff Size should match the actual cuff size implanted and limits the maximum inflation volume that can be selected. Small – 20cc max Medium – 25cc max Large – 30 cc max Partial Hold Volume controls the inflation volume used for a partial hold. MAP Threshold – inflation hold pressure change of more than this will trigger a new volume calibration cycle to keep the inflation volume constant.

Confidential – Training Information Slide 26 Transferring Driver Data to a Memory Stick Shortcut opens Reports folder Shortcut opens memory stick Reports folder contains one subfolder for each Patient ID Drag patient folder to memory stick

Confidential – Training Information Slide 27 Viewing Reports from a Memory Stick 1.Open Patient folder from memory stick 2.Select file (name includes date & time) 3.Open HTML file in browser