Training Module Presented by Steve Wright

Slides:



Advertisements
Similar presentations
ISO 9001:2000 Documentation Requirements
Advertisements

Measurement Systems Analysis with R&R INNOVATOR Lite TM The House of Quality presents.
Copyright Alan Rowley Associates Steps to an Accurate Result Select a method and validate it as suitable for the purpose envisaged. Establish that.
ISO 9001 : 2000.
Comments on the Quality Assurance Standard EN14181 VGB Working Group Emissions Monitoring.
Louisiana Department of EnvironmentalQuality LDEQ CAM Plan Overview LDEQ’s 27 th Annual Conference on the Environment Cajundome Convention Center Lafayette,
Establish Verification Procedures (Task 11 / Principle 6)
Corrective & Preventive Action Programme l Corrective and preventive action managed by one programme l Closely linked to the internal audit programme l.
Laboratory Personnel Dr/Ehsan Moahmen Rizk.
Short Course on Introduction to Meteorological Instrumentation and Observations Techniques QA and QC Procedures Short Course on Introduction to Meteorological.
Quality Assurance/Quality Control Policy
Prepared by Long Island Quality Associates, Inc. ISO 9001:2000 Documentation Requirements Based on ISO/TC 176/SC 2 March 2001.
Measurement System Analysis Kevin B. Craner Boise State University October 6, 2003.
Technical requirements  Sampling  Analysis  Reporting of the results.
ISO 9000 Certification ISO 9001 and ISO
To carry out an investigation of plant species in a local habitat using quantitative survey.
SystematicSystematic process that translates quality policy into measurable objectives and requirements, and lays down a sequence of steps for realizing.
Chapter 10 Verification Procedures. Objective In this module, you will learn: u How to define verification u What functions are part of HACCP plan verification.
Seafood HACCP Alliance for Training and Education Chapter 10 Principle 6: Establish Verification Procedures.
Effectively applying ISO9001:2000 clauses 5 and 8
Approach of a UK auditor Paul Mudway Mudway Health, Safety & Environment.
S3: Module D Physikalisch-Technische Bundesanstalt Session 3: Conformity Assessment Module D Peter Ulbig, Harry Stolz Belgrade, 31 October.
Ships in Service Training Material A-M CHAUVEL QMS Terms & Definitions 2009.
CEN workshop EN 14181, May 2006, Paris 1 Inquiry of implementation and experiences with EN in Belgium Raf De Fré, Ive Vanderreydt - VITO, Mol.
System Testing There are several steps in testing the system: –Function testing –Performance testing –Acceptance testing –Installation testing.
Answering questions about life with statistics ! The results of many investigations in biology are collected as numbers known as _____________________.
Structured COBOL Programming, Stern & Stern, 9th edition
The Role of the Internal Auditor for Maintaining System Compliance and Promoting Continuous Improvement Wayne M. Uttke
VALIDATION METHODOLOGY
18/09/2015 Technical and Marketing Resources Ltd.1 CEMSuite Plus Emissions Data logging and presentation software.
Chapter Thirteen Validation & Editing Coding Machine Cleaning of Data Tabulation & Statistical Analysis Data Entry Overview of the Data Analysis.
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
Laboratory QA/QC An Overview.
Uncertainties Using & Calculating Uncertainties for Electrical Measurement.
CALIFORNIA DEPARTMENT OF EDUCATION Tom Torlakson, State Superintendent of Public Instruction Special Education Self Review (SESR) Activity Three: Corrective.
What is SPSS  SPSS is a program software used for statistical analysis.  Statistical Package for Social Sciences.
Educational Research: Competencies for Analysis and Application, 9 th edition. Gay, Mills, & Airasian © 2009 Pearson Education, Inc. All rights reserved.
Social Science Research Design and Statistics, 2/e Alfred P. Rovai, Jason D. Baker, and Michael K. Ponton Within Subjects Analysis of Variance PowerPoint.
Exercise 1 Tor Stålhane IDI / NTNU. Intro The strength of ISO 9001 and many other standards is that they focus on “What shall be done” and leave “How.
Project quality management. Introduction Project quality management includes the process required to ensure that the project satisfies the needs for which.
EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Wenclawiak, B.: Fit for Purpose – A Customers View© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in.
Thanks for giving me an opportunity to share with you our process for controlling media and other supplies. Disclaimer: We are not yet accredited to ISO.
Control Charts and Trend Analysis for ISO 17025
John Batty DEFRA UK Bratislava November Legal Background For any given surface water body, applying the MAC-EQS means that the measured concentration.
? Training removes doubt, instills confidence, and lays the foundation for everyone’s skill and experience level.
Establishing by the laboratory of the functional requirements for uncertainty of measurements of each examination procedure Ioannis Sitaras.
ISO Certification For Laboratory Accreditation ISO Certification For Laboratory Accreditation.
Version 1.0, May 2015 BASIC PROFESSIONAL TRAINING COURSE Module XX Regulatory control Case Study This material was prepared by the IAEA and co-funded by.
Chapter 10 Verification Procedures.
Monitoring aspects of permits and inspections (1)
National Laboratory Association
RELATIONS AND FUNCTIONS
Chapter 10 Verification Procedures.
Compiled by the UK NANDTB Updated Jan 2018
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Assuring the Quality of your COSF Data
Data Upload & Management
The MIS and Dashboard.
Chapter 13 Quality Management
Writing the IA Report: Analysis and Evaluation
Queries Training Module.
ISO 9001:2008 Quality Management Systems
How to conduct Effective Stage-1 Audit
Making Use of Associations Tests
Nonconformity Writing
Assuring the Quality of your COSF Data
Presentation transcript:

Training Module Presented by Steve Wright CEMQual Training Module Presented by Steve Wright 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. CEMQual CEMQual is a module designed to assist operators comply with the requirements of BS EN 14181 It accepts data input manually It can perform all the key calculations for QAL2, AST and QAL3 It can produce CUSUM, Shewhart and moving median graphs All graphs and spreadsheet data can be printed or output as a JPEG picture. Fully compliant with EN 14181 and validated by AEA Technology 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. EN 14181 BS EN 14181 applies only to CEMs permanently installed at WID and LCPD installations. It does not apply to portable CEMs, such as those used in SRMs. These requirements are described in the applicable standards for SRMs. Also BS EN 14181 only applies to the CEMs themselves and not the data collection and recording systems. BS EN 14181 specifies three quality assurance levels (QALs) and an annual surveillance test (AST). These quality assurance levels follow a logical sequence to demonstrate the suitability of the CEM, its correct installation, commissioning, and calibration, followed by continuing and correct operation. 07/12/2018 Technical and Marketing Resources Ltd.

Quality Assurance Levels QAL1 A procedure to demonstrate that the CEM is suitable for the intended purpose before installation, by meeting required performance standards and the uncertainty budgets specified in EU Directives. QAL2 A procedure to calibrate the CEM once it has been installed, using SRMs and verify whether it still meets the required uncertainty budgets, once installed. QAL3 A procedure to maintain and demonstrate the required quality of the CEM duing its normal operation by checking the zero and span readings. AST A procedure to evaluate the CEM to show that it continues to function correctly and the calibration function is still valid. 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. QAL 1 The first level of quality assurance, QAL1, demonstrates the potential suitability of the CEM before it is installed on a stack. In England and Wales, MCERTS certification at an appropriate certification range is taken as evidence of compliance with the QAL1 requirements. The WID and LCPD specify uncertainty budgets expressed as 95% Confidence Intervals. Whilst the procedure for determining uncertainties is described in BS EN ISO 14956, making use of type-testing data, the procedure is both complex and prone to differing interpretations. Therefore the Environment Agency’s approach is to make use of the known linear relationship between uncertainty budgets and certification ranges, whereby the suitability of a CEM is determined by using certified ranges. 07/12/2018 Technical and Marketing Resources Ltd.

Baseline ranges, ELV and Uncertainties 07/12/2018 Technical and Marketing Resources Ltd.

CEMQual Configuration 07/12/2018 Technical and Marketing Resources Ltd.

CEMQual Configuration Select measurement point and measurand Enter operator name and password Enter data in CEMQual/ EN14181 data section Enter slope and zero offset data in “CemSuite calibration” section 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. QAL 2 The second level of quality assurance, QAL2, specifies procedures to verify that the CEM has been installed correctly, calibrated using Standard Reference Methods ( SRM) and that the CEM still meets the uncertainty requirements the EU Directives. The correct installation and functionality of the CEM is verified through inspection and through a set of functional tests, examining performance characteristics such as response time and linearity. SRMs are used to calculate a calibration function for the CEM. The uncertainty of the installed CEM is then determined by calculating the variability of the calibration function. Once installed, the uncertainty of the CEM’s measurements may increase due to specific (and sometimes unique) factors at the installation, such as the position of the CEMs or its sampling system, environmental conditions, stack gas conditions and uncertainties of calibration gases. 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. QAL 2 The QAL2 procedures are carried out when: - the CEM is installed (within 6 months of installation) then at least every three (under the WID) or five years (under the LCPD); whenever there is a significant change in plant operation which changes the emissions; after a failure of the CEM so that significant repair is required; after an significant upgrade or other significant change to the CEM. . 07/12/2018 Technical and Marketing Resources Ltd.

Test Data Entry QAL 2/AST 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. Manual Data Entry Select Measurement Point Select Measurand Clear grid Select number of test results to be entered Open grid for editing Make frame Enter test data pairs Save data 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. QAL2/AST analysis 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. QAL 2 data analysis Firstly click on “Import test data” to enter data from Test data page Check Spreadsheet amd QAL2/AST radio buttons Matrix will automatically fill and perform calculations. Check results box 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. QAL 2 data analysis Select slope and zero in green Slope = span of the analyser Zero = zero offset Range = range of the analyser from zero to nn.nn Variability represents the spread of results. Click on “Apply cal factors” to see effect of applying new zero and slope” Click on Graph radio button to see calibration graph 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. Calibration graph 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. QAL 3 The QAL3 procedure ensures that the CEM remains within the required specifications during continued use. QAL3 achieves this by requiring the plant operator to regularly measure the drift and the frequency of the drift measurements . The frequency between checks depends on the maintenance interval determined during the QAL1 tests, and can be anything from one week to several months. The use of CUSUM charts, however, requires drift tests to be carried out at least weekly. In many CEMS the QAL 3 tests are conducted automatically within an instrument and therefore occur more frequently. 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. QAL 3 Data Entry 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. QAL 3 data Entry To start new chart Access Test data page and select measurement point and measurand Select number of lines of data required Click on new data Select spreadsheet radio button Select Zero or span chart Enter analyser output in yt box Subsequent data entry – follow steps 1, 4, 5, 6 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. Control charts Select the chart you have selected by clicking on the appropriate radio button. Select graph radio button Shewart charts are normally used for FTIR analysers. Cusum drift , Shewhart and Moving media charts use scale 1 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. Cusum Chart 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. Cusum Precision 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. Shewhart Chart 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. Moving Median Chart 07/12/2018 Technical and Marketing Resources Ltd.

Annual Surveillance Test (AST) The annual surveillance test (AST) is a mini-QAL2 test. Its key objective is to check whether the calibration function determined during the QAL2 tests is still valid. The AST consists of the same functional tests as those used in QAL2, whilst the calibration function is checked by using a smaller number of repetitions of the SRMs (typically five repetitions.) If the calibration function is still valid, then no further action is required. If the AST shows that the calibration function is no longer valid, then a full QAL2 is required. 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. AST The AST is very similar to the QAL2 test but is performed on those years when a QAL2 is not. Normally only 5 SRM’s are performed Key difference is the variability test which is designed to check the response up to two times ELV 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. Variability Matrix 07/12/2018 Technical and Marketing Resources Ltd.

Technical and Marketing Resources Ltd. Variability test Click on test data and select measurement point and measurand Click on linearity tab Perform 5 gas injections at 0, 20, 40, 60,80 percent of twice ELV Repeat twice more Enter data in matrix Note results. 07/12/2018 Technical and Marketing Resources Ltd.