Voltage regeneration in servo systems Visual ModelQ Training

Slides:



Advertisements
Similar presentations
© 2002 QxDesign, Inc. Tuning a PI Controller This unit discusses Zone-based tuning for a PI controller Adjusting gains with Live Constants Visual ModelQ.
Advertisements

© 2002 QxDesign, Inc. Building a PI controller This unit discusses Installation of Visual ModelQ The Visual ModelQ default model Placing and configuring.
In this presentation you will:
» When you have completed this module you will know, what components do, what they physically look like and how they are represented in a circuit diagram.
Voltage and Its Measurements
© 2002 QxDesign, Inc. Variation of plant gain This unit discusses Changes in system stability with increasing plant gain Adjusting KP to correct for changing.
©1997 by Eric Mazur Published by Pearson Prentice Hall Upper Saddle River, NJ ISBN No portion of the file may be distributed, transmitted.
Cells have positive and negative electrodes.
ECE 4411 Dynamic Braking of Induction Motors Slow down a machine by converting kinetic energy stored in the rotating mass to heat energy in the rotor and/or.
Lecture 9 Resistors in series and parallel Kirchoff’s laws
Fundamentals of Circuits: Direct Current (DC)
Chapter 23 Circuits Topics: Sample question:
Lesson 15 – Capacitors Transient Analysis
Copyright © 2009 Pearson Education, Inc. Lecture 10 – AC Circuits.
Instrumentation & Power Electronics
IEEE’s Hands on Practical Electronics (HOPE)
CAPACITORS & RESISTORS. RESISTORS A resistor, like batteries and lights, can also be present in an electrical circuit. A resistor limits the flow of electricity.
Lec. (4) Chapter (2) AC- circuits Capacitors and transient current 1.
Lecture B Electrical circuits, power supplies and passive circuit elements.
Copyright © 2009 Pearson Education, Inc. Chapter 26 DC Circuits.
Engineering H192 - Computer Programming Gateway Engineering Education Coalition Lab 4P. 1Winter Quarter Analog Electronics Lab 4.
Chapter 22 Alternating-Current Circuits and Machines.
1 © Unitec New Zealand APTE 5601+DE4401 Topic 2 DC C IRCUITS.
Remember?  An electron is moving downward with a velocity, v, in a magnetic field directed within the page, determine direction of force.
Power Electronics and Drives (Version ) Dr. Zainal Salam, UTM-JB 1 Chapter 3 DC to DC CONVERTER (CHOPPER) General Buck converter Boost converter.
Chapter 22 Current Electricity.
1 Computer Power Supply Amateur Radio Conversion For Cheap +12 vdc Power March 17, 2003.
Alternating Current Circuits
Electromagnetic Oscillations and Alternating Current
Chapter 28 Direct Current Circuits. Electromotive Force An electromotive force device, or emf device, is a source of constant potential. The emf describes.
09/16/2010© 2010 NTUST Today Course overview and information.
Basic Electrical Engineering Lecture # 04 Simple Resistive Circuits Course Instructor: Engr. Sana Ziafat.
Chapter 18 Direct Current Circuits. Sources of emf The source that maintains the current in a closed circuit is called a source of emf The source that.
Direct Current And Resistance Electric Current The Battery Resistance And Ohm’s Law Power Internal Resistance Resistors In Combination RC Circuits Written.
Copyright © 2009 Pearson Education, Inc. Chapter 25 Electric Currents and Resistance.
Engineering H192 - Computer Programming The Ohio State University Gateway Engineering Education Coalition Lab 3P. 1Winter Quarter Analog Electronics Lab.
Electromagnetic Induction
Chapter 13 Principles of Electric Circuits, Conventional Flow, 9 th ed. Floyd © 2010 Pearson Higher Education, Upper Saddle River, NJ All Rights.
Applied Circuit Analysis Chapter 3 - Power and Energy Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
© Houghton Mifflin Harcourt Publishing Company Section 3 Current and Resistance Chapter 17 Current and Charge Movement Electric current is the rate at.
Chapter 12 Principles of Electric Circuits, Conventional Flow, 9 th ed. Floyd © 2010 Pearson Higher Education, Upper Saddle River, NJ All Rights.
Chapter 13 Principles of Electric Circuits, Conventional Flow, 9 th ed. Floyd © 2010 Pearson Higher Education, Upper Saddle River, NJ All Rights.
Electrical Systems. VOCABULARYOBJECTIVES  Series circuit  Voltage drop  Kirchoff’s Voltage Law Describe a series circuit. Calculate the resistance.
Exam 2: Review Session CH 24–28
1 ECE 3336 Introduction to Circuits & Electronics Set #15 Complex Power Fall 2011, TUE&TH 4-5:30 pm Dr. Wanda Wosik.
Electronic. Analog Vs. Digital Analog –Continuous –Can take on any values in a given range –Very susceptible to noise Digital –Discrete –Can only take.
ELECTRICAL SYSTEMS. Chapter Twenty One: Electrical Systems  21.1 Series Circuits  21.2 Parallel Circuits  21.3 Electrical Power.
EMT212 – Analog Electronic II
1 Electrical Skills Voltage and Its Measurements.
Lectures 7 to 10 The Electric Current and the resistance Electric current and Ohm’s law The Electromotive Force and Internal Resistance Electrical energy.
Unit 13 Electric Circuits
18240 Element two - Components INPUTS OUTPUTS PURPOSE TYPICAL USE.
Electric Circuits. Electric circuit: a complete path from the positive terminal to the negative terminal.
In practice, it is often required to make or break an electric al circuit in many operations. In some applications, it is desirable that this make and.
Simple Circuits 1 st year physics laboratories University of Ottawa
Electric Current Everything (water, heat, smells, …) flows from areas of high concentration to areas of lower concentration. Electricity is no different.
Chapter 13 The Basic Elements and Phasors. Objectives Be able to add and subtract sinusoidal voltages or currents Use phasor format to add and subtract.
Chapter 9 CAPACITOR.
Capacitance. Device that stores electric charge. Construction: A capacitor is two conducting plates separated by a finite distance Typically separated.
HOW TO SELECT A SERVO SYSTEM
Types Of Thyristors And Their Applications
Chapter 23 Electric Circuits Neurons connected together to form the electrical circuitry in the brain.
Lesson 12: Capacitors Transient Analysis
Electrical circuits, power supplies and passive circuit elements
Electronics Circuits.
Electrical circuits, power supplies and passive circuit elements
PES 1000 – Physics in Everyday Life
Diodes AIM: To understand diode characteristics
Circuits Kirchhoff’s Rules
Braking of Three Phase IM
Presentation transcript:

Voltage regeneration in servo systems Visual ModelQ Training This unit discusses What voltage regeneration is. How to model a servo system during regeneration

What is voltage regeneration? In servo systems, when a motor decelerates under power, the motor operates in “generator” mode, feeding energy back to the drive. Standard servo drives use diodes to feed line power into the bus, and those diodes block the energy from returning to the AC line. The result is that the mechanical (kinetic) energy feeds into the bus capacitor and is converted to potential energy, raising the bus voltage. If this process continues uncontrolled, the voltage can elevate to levels high enough to cause catastrophic failure. **This unit can be completed with a free (unregistered) copy of Visual ModelQ

What is voltage regeneration (cont.)? The most common solution is to use a transistor to temporarily connect a high-power resistor across the line to burn the energy as heat (I2R) losses. Many servo drives include a regen resistor that can dissipate the regen power for most applications. For systems with larger amounts of regenerative energy, an external resistor is added in parallel to the internal resistor. The external resistor is usually larger and dissipates a greater amount of power. Most drives monitor the bus voltage and shut down the drive when this voltage reaches an upper limit. This protects the drive when the regen circuit cannot hold the bus down. **This unit can be completed with a free (unregistered) copy of Visual ModelQ

To run Visual ModelQ the first time: Install Visual ModelQ To run Visual ModelQ the first time: Click here to visit www.QxDesign.com Download Visual ModelQ** Run Visual ModelQ installation Launch Visual ModelQ using the Windows start button or clicking on the icon The “default model” should appear **This unit can be completed with a free (unregistered) copy of Visual ModelQ

Load the model “Regen Voltage” Visit www.QxDesign.com/VisualModelQ#Training Download “Regen Voltage.mqd”

Review the model The next several slides will review the model for regenerative voltage section-by-section: Start with a standard servo system. Calculate the mechanical power. Deduct a constant power drain to represent system losses. Divide the power entering the bus capacitor by the bus voltage to calculate current feeding the bus capacitor. Deduct the current flowing through the regen resistors from the current feeding the bus capacitor. Integrate the current in the bus capacitor to derive the bus voltage. The integrator should never fall below the line voltage; the line voltage acts like a lower limit on the integrator, holding the bus voltage from falling below that value. Monitor the voltage for a fault condition (> 390V). Use a hysteresis block to control the regen transistor (330V to 360V). Connect the bus voltage across the regen resistors when the hysteresis block is on. Calculate the current flowing through the regen resistors due to the bus voltage using Ohm’s law. Monitor bus voltage, regen current, and regen power.

Review the model The top portion is a standard servo control system. Torque and Velocity “extenders” carry those signals to the regen circuit.

Review the model Mechanical power is formed as Velocity x Torque Multiply by -1 to calculate power from the motor to the bus

Review the model Add a constant power loss as a simple approximation In practical systems, the power loss formula is more complex

Review the model Divide the output power by the bus voltage; this forms current This step converts mechanical power to electrical power

Review the model Subtract the current flowing through the regen resistors We will discuss to how this current is calculated later

Review the model Divide by capacitance to calculate the integration rate in the bus capacitor

Review the model Integrate the cap voltage using a clamped integrator with a lower limit of 300V, the DC bus. The cap will not discharge below this.

Review the model Monitor the bus voltage. If it goes above the upper limit (400V) show a message indicating a fault.

Review the model Use a hysteresis block to control the regen transistor. Turn on when bus > 360 and off when bus < 330.

Review the model Use an analog switch as a simple model for a transistor. When hysteresis controller is on, connect bus to regen resistors.

Review the model Calculate current from internal regen resistor (80 ohm).

Review the model Calculate current from external regen resistor (10 ohm).

Review the model Sum regen resistor currents and subtract from capacitor current.

Review the model Monitor RMS regen current and RMS regen voltage. Note the RMS voltage across the resistor is not equal to the bus voltage.

Review the model Calculate and monitor average power

Review the model Also, monitor average voltage on a dial meter.

Review the model Finally, monitor cap voltage (above) and against velocity. Trigger with Vc (left of scope) to sync with upper scope.

Review the results During decel, the bus voltage (blue) grows until it reaches 360V; then the regen circuit turns on until bus voltage falls below 330V. 360V 330V 300V

Review the results In this snapshot, VBus = 343V, regen power = 489W, RMS external regen current = 15.6A, & RMS resistor voltage = 156V.

Click here for information on Visual ModelQ Visit www.QxDesign.com for information about software and practical books on controls. Click here for information on Control System Design Guide (2nd Ed.), published by Academic Press in 2000 Click here for information on Visual ModelQ Click here for information on Observers in Control Systems, published by Academic Press in 2002