SK-ACP Installation Overview

Slides:



Advertisements
Similar presentations
1 UNIT I (Contd..) High-Speed LANs. 2 Introduction Fast Ethernet and Gigabit Ethernet Fast Ethernet and Gigabit Ethernet Fibre Channel Fibre Channel High-speed.
Advertisements

Improvements in EverAccess
Modems Telemetry Products Intelligent Modems. Modems  1. What is an intelligent Modem?  2. Where can they be applied?  3. Are they easy to install?
Alarm transmission over IP networks
Remote Monitoring and Control System
California Access Controls Inc Exciting features that are extremely easy to use Exciting features that are extremely easy to use Access Control.
ACCESS CONTROL SOLUTIONS
Secura Key Access Control Product Overview.
Network Solutions
SK-NET™ Tutorial SK-NET™ is a Windows® based software program designed to monitor and control a network of up to 100 Secura Key SK-ACP 2-door control panels.
bright blue. So Smart, Its Simple! To the Presenter:
Configuring APACS & AAN Controllers
ACCESS CONTROL SOLUTIONS Since RBH Access Technologies RBH was established in 1995 and released its first Axiom system in the fall of To date.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
What we do Larotecs Web2M is an off-the shelf, end-to-end, web-based solution designed to manage multiple widely distributed devices.
HWg-Juno HW group is a manufacturer of IP-based sensors from Prague, Czech republic. HWg delivers remote monitoring & control solutions.
Introduction to Network
Model # USR8000A (Rev 02) U.S. Robotics Broadband Router.
Quick Installation Guide for Hurricane8800P
Networking | Hardware Components
ID to 8 Loop Intelligent Fire Alarm Panel
Telemetry Modules Quick Start
RK-65K Product Training Installation Operation Troubleshooting
SK-NET™ 4.0 Tutorial SK-NET™ is a Windows® based software program designed to monitor and control a network of Secura Key SK-ACP 2-door control panels.
Tecom IP Receiver. Overview The Tecom IP Receiver is a server which provides a cost-effective and secure method to monitor Challenger panels over IP networks.
Basics of Communications Presented By Patrick Bolwahnn April 14, 2005.
QUICK GUIDE MANUAL GV-DVR System Organization 2. Specification.
XT30/XT50 Basic Training System Overview
Nokia 30 technical specification
Integrated Technology!
BioSENSE I introduction
POC Security System High security system combining PIN-on-Card, information security, physical access, control and alarm – all in one system.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Total HVAC Control from anywhere Easy control that can save a fortune
GS3055-I GSM Universal Wireless Alarm Communicator
1 Strictly confidential | Engineering| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of.
PXL-500/-510 Tiger Controller II
KX-NS1000 Initial Set Up For step by step : 16 May,
SK-NET™ 5.0 Tutorial SK-NET™ is a Windows® based software program designed to monitor and control a network of Secura Key SK-ACP 2-door control panels.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Training.
Copyright © 2013 FingerTec Worldwide Sdn.Bhd. All rights reserved.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
SF-3000 Installation Manual. 2 Back of SF CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500)
1 Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
SmartLog X 3 TEAM Basic SmartLog X 3 TEAM Basic DescoEMIT.com USER STATUS USER EDIT TEST LOG ADMIN TEST MACHINE SCHEDULE INSTALL System Requirements:
CSCI 1101 Intro to Computers 6. Local Area Networks.
Chapter 5 Networks Communicating and Sharing Resources
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
10 February Doors Software Overview. 10 February This presentation is an overview of the basic fundamentals of the Doors software. –Host computer.
TL250-Internet Communicator. Compatibility Specifications VDC current draw 12 VDC input voltage Size: 3.25” × 5.25” (8.3 × 13.3)cm Operating.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
WCR 12/2002.
ETHLON LonWorks Ethernet Adapter Conventional Approach SIPAI Solution ETHLON DIRECTLY REPLACES SLTA-10 OR SLTA CONNECTIONS.
Who is Inner Range? Inner Range is an Australian Electronic Security Manufacturing Company. Established in 1988 with a Major focus on the Australian Security.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
FOX AVL SYSTEM Satellite vehicle locating, tracking and fleet management.
Computer and Information Science Ch1.3 Computer Networking Ch1.3 Computer Networking Chapter 1.
Integra32 System - Training Course
Copyright © 2008 FingerTec Worldwide Limited. All rights reserved
New product introduction:
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
CMV-NET Chigo VRF Network Centralized Control System
Frequently Asked Questions (FAQ)
COSEC ARC IP based Access Control Panel.
Level 2 Diploma Unit 10 Setting up an IT Network
Connections Topology of Apollo ACS.
Basics of Communications
Presentation transcript:

SK-ACP Installation Overview

Agenda Overview SK-ACP (Access Control Panel) Resources Available SK-NET (Software) Demo

SecuraKey Take Away Access Control System: Easy to Learn (Installers, End User) Where to Locate Resources Full Featured Robust Software Scalable Affordable

Access Control Panel Network Modules Secura Key ACP Access Control Panel Network Modules

SK-ACP Advanced Control Panel Supports Two Wiegand Output Devices (readers, keypads, etc.) 100 panels can be linked to a PC with SK-NET™ using a simple RS-485 bus LAN/Modem Capability for Unlimited Remote Locations Card Capacity: 65,535 User Capacity Transactions: 4,864 Stored Time Zones: 15 card access/1 door unlock 32 Programmable Holidays Auto-Select Daylight Savings time Facility Codes: Up to 16 Facility Codes Latch/Shunt Timer: ¼ to 30 seconds AntiPassback: Real or Timed/ 1-30 seconds Inputs (2 per door): Define as Door Monitor, Tamper Monitor, Remote Open(REX) Remote Inactive, Bell, Arming Circuit or User Defined Limited Use Cards: Block of 4000 within 65,535 1-500 uses, days, weeks, or # days after first use

SK-ACP Notes: Wiring Lock Power 2 Cond unshielded SK-ACP SK-ACP Cat5 or twisted pair Reader 6 Cond Shielded No twisted pair

Connect 1… 1

Connect 98, 99, 100 and more… Connect over 100 panels using a simple 2-wire RS-485 bus 1 100

Flexibility in Network Configuration Connect Panels in Almost any Configuration Connect to PC Using RS-232, RS-485, Modem or LAN network Hard Copy Printout of All System Activity Using a Serial Printer

Flexibility in Project Planning Connect panels in almost any configuration Connect to PC using RS-232, RS-485, Modem or LAN network Hard-copy printout of all system activity using a serial printer

Flexibility in Project Planning Daisy Chain/Multi-Drop

Flexibility in Project Planning Star/Fan-out

Flexibility in Project Planning T-Configuration

Flexibility in Project Planning LAN Connection

Plug in Terminal Blocks are Provided

Reader

Follow Status of a door

Tells me there is a problem w/ that door

SK-ACP Notes: General Use Separate Power Supplies for the SK-ACP and the Locks Use 24VDC/500mA or higher for the SK-ACP Always close SK-NET before Windows to avoid communications issues Cards and Facility Codes: up to 16 within the panel Card ID numbers must be unique, even if multiple Facility Codes are used. The system checks the FC, but uses the ID number to identify cardholders Facility code 12, ID #1-10 = FC 15, ID # 1-10 Should be: FC 12, ID # 1-10 and FC 15, ID # 11-20 (Facility codes should be kept to a minimum. More FC = less secure)

May operate under variety of user defined conditions: SK-ACP Notes: Relays Each Door has 1 “Latch” Relay and 1 “Aux” Relay, each with two sets of contacts Latch Relays Location J1, J2 1 set of contacts can: Unlock door Activate Gate Operator The other set can: Shunt Alarm Contact Start a video recorder Auxiliary relays Location J3, J4 May operate under variety of user defined conditions: (i.e.) Error Alarm Tamper Alarm Door Bell Door Held Open Emergency Exit alarm Etc. Programmed through SK-NET

J1 J3 Relays

NOTE: All inputs are configured as NO circuits SK-ACP Notes: Inputs Each Reader may be associated with up to 2 inputs. These can monitor contact closures at Remote Switches, Door contacts, Vehicle presence detectors, etc. Inputs defined through SK-NET (Tamper, Remote Open, Door Monitor, etc.) Located at J1, J2 terminals 7, 9 and share common terminal 8 NOTE: All inputs are configured as NO circuits If NC is required ( “Door Monitor” only ) Disconnect power from panel Remove jumper from pins 2, 3 on J10 Place jumper on pins 1, 2 on J10 Restore power Test Door Monitor input

J10 J1 Inputs

SK-ACP Notes: RS-232 Connection RS-232 used to connect the COM port of a PC to a single SK-ACP, or as a gateway to a series of SK-ACP’s J7 or RJ11 Jack in center of the Board Distance < 100’ NEVER connect a telephone line directly into the RJ11 Jack on the SK-ACP!

RJ11 J7 RS-232

SK-ACP Notes: RS-485 Connection RS-485 Bus is used to link multiple SK-ACP units into a network Run CAT 5 Between J8 plugs (terminals 1, 2) Distance between the PC ‘gateway’ and SK-ACP > 100’ 232/485 converter required (SK part# NET-CONV-P) Twisted pair Total Cable distance not to exceed 4000’ Terminal 3 is a signal GND. If connected to conductor of twisted pair this must be an insulated conductor and NOT connected to earth GND Starts to become a consideration at approx 2000’

J8 RS485

Networking Modules Plug-in Modules for SK-ACP LAN Applications SK-LAN-MOD Use existing network infrastructure to monitor and control the Access Control system Wireless Applications SK-WLS-MOD Uses widely accepted 802.11g protocol (existing router and wireless system in place)

SK-ACP Notes: LAN Connection SK-LAN-MOD or SK-WLS-MOD Embedded Devices (receive power from the SK-ACP) Connect to J9 Connector Disconnect Power from SK-ACP Remove 2 pin jumper from J9 pins 6, 7 Plug in Module SK-LAN-MOD connect Ethernet cable Restore Power Have available: Hardware Address Unique IP Address

J8 LAN

SK-ACP Notes: Power and Batteries SK-ACP must be connected to source of low voltage power RK-WM/ RK-WS readers 24VDC, 500mA SK-LAN-MOD, SK-WLS-MOD 24VDC, 1Amp RK-WL 24VDC, 1.5Amp (Basic config powered with SK-ACP-PS: 24VDC 500mA and a 1.9AH backup battery) Do not energize SK-ACP until all connections are made

SK-ACP Notes: General 99% of technical ‘issues’ are addressed by: Referring to: The Manual Troubleshooting Guide Following the Installation Instructions Referring to the Web Site www.securakey.com

SK-Net Software Basic Multi-Location (Remote Access) Multi-User RS232 Direct Connect RS485 Direct Connect w/ RS-232 to RS-485 converter Single LAN TCP/IP connection Multi-Location (Remote Access) Multiple LAN TCP/IP Connections Modem Dial-up Multi-User Client Server license for 2, 5, 10 or 15 workstations

Multi-Location (Remote Access) SK-ACP Notes: Basic Version SK-NET-DM RS232 Direct Connect, 1 LAN, RS485 Direct Conn w/RS-232 to RS-485 conv Single Location Single Workstation Multi-Location (Remote Access) SK-NET-MLD Multiple LAN TCP/IP connections, Modem Dial-up Multiple Locations Single Workstation Multi-User SK-NET-MLD-CS Client Server license for 2, 5, 10 or 15 workstations Multiple Locations Multiple Workstations

Features of SK-NET Multiple Locations (adding) Customize the System Location Time Zones (editing, limiting, etc) Antipassback (Timed, Real, Soft and Hard) Single Reader Time Zone Editing Creating Access Groups Changing Reader icons Setting Door Schedules Changing Latch timer for a single reader Holidays Daylight savings time IN and OUT Readers (programming) Reader Groups (creating, editing) Door Controls (setting and using) Inputs/Outputs Programming custom Wiegand formats Adding Facility Codes

Features of SK-NET Managing Users Managing Transactions Reports Adding/Deleting Customizing User Data Fields Sorting Filtering Users User Reports Limited Use Cards Managing Transactions Filtering Transactions Viewing Cardholder Photos Archiving Excluding Transaction types for all/ for one reader Reports Transaction Reports User Information Report List of Readers in a Location List of Readers in an Access Group List of Users in Access Group Security Passwords Assigning Operator Levels System Activity Log Password Protection

Transaction History

Transaction Filters

Define User Properties

Modify Single or Range of Users

Location Connections

Set Up Time Zones

Set Up Door Schedules

5 Main Steps in System Setup Establish communications to the readers. Setup any or all restrictions for times of access. Assign user with cards numbers for any restrictions necessary. Setup any inputs or outputs for special requirements. Keep track of who uses the reader, time, date, and area of entrance.