COMSOFT GmbH | NetTEST II | June 2009 | Page 1 Professional Test Tool for PROFIBUS DP Networks NetTEST II PROFIBUS Analysis and Test Tool.

Slides:



Advertisements
Similar presentations
© 2006 FedEx. All rights reserved. FedEx Ship Manager ® at fedex.com Shipping Administration.
Advertisements

Computer Networks TCP/IP Protocol Suite.
Follow the instruction to install the PC Suite from the SD card: 1.Go to the settings -> SD Card & phone storage -> Enable the mass storage only mode 2.Connect.
Chapter 7 Networking: Computer Connections
Thema: Menü Ansicht, Master, Folien-Master 1 ITU - IP Telephony Workshop June Standards for IP-telephony P.A.Probst, External Relations Swisscom.
XFEL 2D Pixel Clock and Control System Train Builder Meeting, DESY 22 October 2009 Martin Postranecky, Matt Warren, Matthew Wing.
Alarm transmission over IP networks
Slide 1 Orion Telecom Networks Inc Slide 1 XC 64 E1 Electronic Patch Panel xcvcxv Updated: Nov, 2010Orion Telecom Networks Inc XC 64 Port.
Protocol layers and Wireshark Rahul Hiran TDTS11:Computer Networks and Internet Protocols 1 Note: T he slides are adapted and modified based on slides.
Computers Are Your Future © 2005 Prentice-Hall, Inc.
1 Chapter One Introduction to Computer Networks and Data Communications.
Presented by: Eng. Karam Al-sofy
Smart.IC II project Forklift truck connection Forklift truck connection, outside of the connector Automatic data download through GPRS and anlaysis of.
Solarwind solutions The Hybrid Home Customer presentation.
Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
A presentation by Werardt Systemss P Ltd An Online Machine Monitoring System.
Module 3 Configuring Hardware on a Computer Running Windows XP Professional.
Fire Alarm Circuit Design and Fire Alarm Control Units
THE DEVICE, THE FEATURES & Centralized Management System (CMS)
SystemCheck for TestNav. Agenda 2 SystemCheck for TestNav – Overview – iPads and Chromebooks – Accessing SystemCheck SystemCheck – Check Your System Proctor.
RS-485 Data Link Tester Team Members:Raymond Weber Lance Spotted Elk Sponsor:LED Effects.
7.1 Chapter 7 Transmission Media Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Planning and Cabling Networks
DeviceNet 2400, 2500, 26/2700.
DE2-115 Control Panel - Part I
Doc.: IEEE /0587r0 Submission May 2009 Vinko Erceg, BroadcomSlide 1 40MHz BT Over the Air Demonstration Date: Authors:
MUR-System Next We want with this PowerPoint show how easy it is to install the MUR-Systems hardware. You can try the full version of the software from.
Nokia 30 technical specification
Installing Windows XP Professional Using Attended Installation Slide 1 of 30Session 8 Ver. 1.0 CompTIA A+ Certification: A Comprehensive Approach for all.
Basic Jens Neigaard.
Professor Nigel Linge Computer Networking and Telecommunications Research Group University of Salford.
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
 COMSOFT GmbH | LabVIEW PROFIBUS VISA Driver | March 2009 LabVIEW PROFIBUS VISA Driver.
Sales Manual B.Braun Space
Advanced Workgroup System. Printer Admin Utility Monitors printers over IP networks Views Sharp and non-Sharp SNMP Devices Provided Standard with Sharp.
SMART. ON Battery monitor Measured instantaneous data: V, I, T, and A Storage and analysis of history data Statistics analyses Programming of charging.
Reference Document1 Noise Cancellation Techniques This presentation is a property of Kaihatsu Techno Centre Pvt. Ltd. This is intended for the restricted.
Network+ Guide to Networks, Fourth Edition
Notes: For the installation of a PB network, you can use shielded twisted pair copper cable, glass or plastic FO and infrared components. And you can mix.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Cisco Confidential 1 © 2011 Cisco and/or its affiliates. All rights reserved.
RAID Redundancy is the factor for development of RAID in server environments. This allows for backup of the data in the storage in the event of failure.
This is the way an organisation distributes the data across its network. It uses different types of networks to communicate the information across it.
USART Communication using the RS standard ETEC6416.
PROFIBUS PA Date 09/19/00, Page 1 PROFIBUS PA s  PROFIBUS PA = PROFIBUS for Process Automation PA is based on the DP and DP Extended protocol DP Master.
Characterizing the Existing Internetwork PART 1
Diagnostic & Troubleshooting Date 06/09/00, Page 1 Diagnostic & Troubleshooting s.
CB901 Product Presentation CB901 Product Presentation Brought to you by:
PROFIBUS wiring/installation can be done with:
Chapter 9A Network Basics.
CISCO NETWORKING ACADEMY Chabot College ELEC Hyperterminal Access to Routers.
1 © 2003, Cisco Systems, Inc. All rights reserved. CCNA 2 Module 9 Basic Router Troubleshooting.
1. MAGNETIC HARD DRIVES 2. SOLID STATE DRIVES 3. OPTICAL DISKS 4. FLASH MEMORY 5. CLOUD STORAGE 6. CONNECTIVITY DEVICES Storage and connectivity devices.
Ch.2 – Introduction to Routers
CCNA 2 Week 1 Routers and WANs. Copyright © 2005 University of Bolton Welcome Back! CCNA 2 deals with routed networks You will learn how to configure.
1 Version 3.1 Module 1 WANs and Routers. 2 Version 3.1 WANS WAN operates at the physical layer and the data link layer of the OSI reference model. Provide.
 COMSOFT GmbH | NetTEST II | July 2005 | Page 1 NetTEST II PROFIBUS Analysis Tool Professional Test Tool for PROFIBUS-DP-Networks.
Computer Hardware Introduction to Computer Components and Terminology.
SmartMQn Motor Horner APG, LLC September 9, 2008.
Bluetooth In 1994, the L. M. Ericsson company became interested in connecting its mobile phones to other devices without cables. A SIG (Special Interest.
Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between.
CMV-NET Chigo VRF Network Centralized Control System
Certified PROFIBUS Engineer V4.1
Quick help for fault location and reliable detection of defects
Professional Test Tool for PROFIBUS DP Networks
IS IT EFFECTIVE TO RUN ONLINE DATING BACKGROUND CHECKS YOURSELF?
NetTEST II PROFIBUS Analysis Tool
Professional Test Tool for PROFIBUS DP Networks
The simple system solution
Quick help for fault location and reliable detection of defects
Presentation transcript:

COMSOFT GmbH | NetTEST II | June 2009 | Page 1 Professional Test Tool for PROFIBUS DP Networks NetTEST II PROFIBUS Analysis and Test Tool

COMSOFT GmbH | NetTEST II | June 2009 | Page 2 NetTEST II with Online-Function for the use with operational PROFIBUS networks NetTEST II with Online-Function for the use with operational PROFIBUS networks NetTEST II with DP-Mono-Master function for DP-Slave configuration NetTEST II with DP-Mono-Master function for DP-Slave configuration NetTEST II Basis System for performing physical measurements NetTEST II Basis System for performing physical measurements NetTEST – available in three versions

COMSOFT GmbH | NetTEST II | June 2009 | Page 3 95% of all problems in PROFIBUS DP networks are caused by incorrect installations. Installation errors enormously increase interference susceptibility, whether it is a missing terminator or a broken shield. This results in sporadic non-reproducible errors which can be caused for example by an increased EMC-load. Trouble shooting can cost days or even weeks. NetTEST II checks your PROFIBUS DP networks in detail and detects most typical installation problems. Find out for yourself that NetTEST II proves to be a powerful tool for eliminating PROFIBUS problems. Costs Stop of delay Interruption Standstill of Delays NetTEST II checks your PROFIBUS DP network

COMSOFT GmbH | NetTEST II | June 2009 | Page 4 Graphical 128 x 64 Pixels LCD- Display with background illumination Power supply via a rechargeable battery pack Battery capacity for approximately 4 hours of operation 9-pole SUB-D gender changer for connection to PC and PROFIBUS 6 x 4 - Keyboard Complete transport case with international battery charging set incl. power supply, additional battery, power supply adapter, PROFIBUS configuration tool and various adapter cables for PC and PROFIBUS NetTEST – a flexible system for mobile operation

COMSOFT GmbH | NetTEST II | June 2009 | Page 5 Determines the Impedance Cable Length as well as the of the connected PROFIBUS line Detailed measurements on physical level

COMSOFT GmbH | NetTEST II | June 2009 | Page 6 Disruption of strand A, strand B and shield (with distance measured in m) Correct terminating resistor (number and value) V Non-powered terminating resistors Branches (with distance measured in m) Inhomogeneous line segments (with distance measured in m) Short circuits (with distance measured in m) Switched pairs of strands Detection of the most typical installation problems

COMSOFT GmbH | NetTEST II | June 2009 | Page 7 Display of Live List of DP Slaves Display of Ident-Numbers of DP Slaves Signal Quality of DP Slaves Baud Rate Detection und Signal Quality at Running Systems Helpful analysis functions for superior error detection

COMSOFT GmbH | NetTEST II | June 2009 | Page 8 Generation, display and storage of up to 20 test reports Management and archiving of the test reports via connected PC or notebook Communication from PC to NetTEST II via COM-interface und standard-terminal-software (e.g.Hyperterminal). No special software is required. NetTEST II – logs & archives your measurements

COMSOFT GmbH | NetTEST II | June 2009 | Page 9 Analysis of the tested PROFIBUS segment at one glance. All requirements of modern quality systems are met: Evidence of Functionality Archiving Traceability Reproducibility ************************************************ Resulting protocol for PROFIBUS network ************************************************ Test company Name: COMSOFT GmbH Street: Wachhausstr. 5a City : Karlsruhe Phone: / User name : Kurpat ************************************************ Customer Name : Customer 1 Street: City: Phone: *********************************************** Unit: Area 1 Name: Segment 1 PROFIBUS address: 001 Number of 12 Mbit/s-conns in seg.:000 Number of PROFIBUS devices in seg.:002 Baud rate: 1.5 Mbaud Slot time: Date: 15/11/07 Time: 10:54:21 *********************************************** Analysis result for test with no termination Analysis result: No fault! ***************************************** Irregularity A B not detectable Irregularity B Shield not detectable Irregularity A Shield not detectable Capacitive load junction or Impedance changes not detectable Broken line not detectable Cabling ok Impedance app. 133 ohms Cable length app. 26m ********************************************************* Analysis result for test with 1 termination Analysis result: No fault! **************************************** Irregularity B Shield not detectable Irregularity A Shield not detectable Correct termination Number of retries: 3 ********************************************************* Analysation result for Test with 2 term. Analyzation result: No fault! **************************************** Irregularity B Shield not detectable Irregularity A Shield not detectable Correct termination Number of retries: 1 ********************************************************* Detected slaves in the segment PB address LevelStatusIdent. [Name] VOK0xAAAA VOK0xF VOK0x VOK0xAAAB VOK0x00C VOK0x000C VOK0x VOK0x00C VOK0x00C VOK0x00C VOK0xAAAA VOK0x00DD VOK0x VOK0x VOK0x0000 Expected value for level measurement: 2.5V<x<7.2V ********************************************************* PROFIBUS Baud rate detection Baud rate: 1.5 Mbaud Level: 6.0V Status: OK Expected value for level measurement: 2.5V<x<7.2V ********************************************************* End of protocol User nameCustomer ______________________ NetTEST II Measurement Report

COMSOFT GmbH | NetTEST II | June 2009 | Page 10 Performing the Measurement

COMSOFT GmbH | NetTEST II | June 2009 | Page 11 Strand A * Terminating resistor 1 * Strand B * Terminating resistor 2 * Shield * DP Master and DP Slaves * 0 V +5 V Terminating Resistor 0 V +5 V Terminating Resistor Shield A B DrivesGateways Field Device Master Typical PROFIBUS DP RS485 segment

COMSOFT GmbH | NetTEST II | June 2009 | Page 12 0 V +5 V Terminating Resistor NetTEST II is connected instead of the DP Master at either one of the two bus ends Shield DP Slaves can be left connected to the bus in online mode B A DrivesGateways Field Device Master Connection with the PROFIBUS 0 V +5 V Terminating Resistor

COMSOFT GmbH | NetTEST II | June 2009 | Page without terminating resistors 2. with one terminating resistors 3. with both terminating resistors 0 V +5 V Terminating Resistor A Shield B Drives GatewaysField Device During the measurement procedure NetTEST II requests the user to switch on and off the respective terminating resistors Performing a 3-stage test 0 V +5 V Terminating Resistor

COMSOFT GmbH | NetTEST II | June 2009 | Page 14 PROFIBUS address System Baud rate Slot time Number of 12 Mbit/s plugs used Number of devices connected to the bus Simple & quick adaptation to the DP segment

COMSOFT GmbH | NetTEST II | June 2009 | Page 15 The physical measurement of the PROFIBUS line is only carried out within electrical segments, without including repeaters. The minimum length of line to be measured is 10 m. The shorter the line lengths, the more inexactly the measurement may become. Only active stations (Masters) have to be disconnected from the bus, slaves may stay connected. NetTEST II is designed for standard PROFIBUS cable type A (150 Ohm surge impedance, core cross section >0,34 mm²). Different types of cables, e.g. obsolete cable type B (100 Ohm surge impedance) are not to be used and are recognized as faulty by NetTEST II. Start Useful information for physical measurements

COMSOFT GmbH | NetTEST II | June 2009 | Page 16 Setting into operation of DP Slaves without time-consuming implementation of an SPS Configuration of DP Slaves via comfortable PC tool on the basis of GSD file and integrated download function Comfortable access to the I/O-Data of DP Slaves via freely definable tags Display and coding of DP Slave diagnostic data NetTEST II with DP Master function

COMSOFT GmbH | NetTEST II | June 2009 | Page 17 The COMSOFT PROFIBUS Configurator supplies NetTEST II with the DP Slave configuration NetTEST II – Trouble-free & comfortable

COMSOFT GmbH | NetTEST II | June 2009 | Page 18 Start Changing all DP Slave parameters Execution of single PROFIBUS DP services Simple DP Slave start-up – not just for PROFIBUS experts Direct access to selective I/O-Data, e.g. digital outputs NetTEST II – Multi-Talent as DP Master

COMSOFT GmbH | NetTEST II | June 2009 | Page 19 NetTEST II was enhanced by very powerful online measurement functions which even on the operative PROFIBUS give detailed information about existing installation problems. NetTEST II with Online Function up to 12 Mbit/s

COMSOFT GmbH | NetTEST II | June 2009 | Page 20 DrivesGatewaysField Devices Master Measurements on the operative bus

COMSOFT GmbH | NetTEST II | June 2009 | Page 21 Baud rate detection Generate live list Rotation time Signal level measurement Signal level summary list Event log Event count Diagnostic event The following measurements can be conducted in online mode: Measurements with PLC

COMSOFT GmbH | NetTEST II | June 2009 | Page 22 During this Baud rate scan the overall signal quality at the PROFIBUS is measured and a status is indicated. Baud rate detection

COMSOFT GmbH | NetTEST II | June 2009 | Page 23 Current Slave Live List NetTEST II analyses the bus traffic and generates a Live List of all active and passive bus subscribers broken down by Masters and Slaves. Current Master Live List Generating a Live List

COMSOFT GmbH | NetTEST II | June 2009 | Page 24 NetTEST II determines the time the DP Master needs in order to poll all configured DP Slaves. The minimum and maximum values are stored and indicated. Rotation time is an explicit indicator for performance problems, e.g. in a sporadically disfunctional PROFIBUS network Roatation Time

COMSOFT GmbH | NetTEST II | June 2009 | Page 25 NetTEST II measures the signal quality of each DP Slave and visualises the value in a bar graph. Discrepancies of the measured signal levels from the allowed range point to specific errors of the PROFIBUS network, e.g. signal levels above the allowed maximum are typical for reflexions in the PROFIBUS network. Level Measurement

COMSOFT GmbH | NetTEST II | June 2009 | Page 26 In the signal level sum list, the result of the signal level measurement is indicated in form of a table: -ADD – Participant address -COUNT – Number of measurements (excl. Time-outs) -MIN – Minimum Values -AV – Average Values -MAX – Maximum Values Signal level sum list

COMSOFT GmbH | NetTEST II | June 2009 | Page 27 NetTEST II analyses the data traffic between DP Master and DP Slaves and triggers upon communication status changes. The event log is represented in form of a table: - ADD – DP Slave address - DATA OK – DP Slave is in status of data exchange - DATA NR – No Response, DP Slave is not responding - TRY – DP Slave responds only after multiple retries by DP Master - CFG – DP Slave was parameterised or configured - DIA – Diagnostic messages pending at DP Slave Event log

COMSOFT GmbH | NetTEST II | June 2009 | Page 28 Should a singular DP Slave show communication problems in the event protocol, it can be analysed in detail by the event counting. The event count shows the communication statistic for a single DP Slave in detail. Also retries and communication errors are counted. Event count

COMSOFT GmbH | NetTEST II | June 2009 | Page 29 The diagnostic event is an extended function of the event counting and serves the detailed analysis of an event. NetTEST II offers the choice between 6 events that may be triggered, e.g. diagnostic data or input/output data can be analysed. Should the selected event occur, all relevant data are displayed along with it. Diagnostic event

COMSOFT GmbH | NetTEST II | June 2009 | Page 30 Then contact us: COMSOFT GmbH Wachhausstr. 5a Karlsruhe Germany Tel:+49-(0) Fax:+49-(0) Web: Start Are you interested in more information?