Silicon strip detectors for two-dimensional soft x-ray imaging at normal incidence Pedro Rato Mendes LIP Lisbon and University of Algarve, Portugal Amsterdam,

Slides:



Advertisements
Similar presentations
Monte Carlo simulation of a silicon strip detector response for angiographic applications. First approach. C. Ceballos a, G. Baldazzi b, D. Bollini b,
Advertisements

Image quality and spectroscopic characteristics of different silicon pixel imaging systems M. G. Bisogni, D.Bulajic, M. Boscardin, G. F. Dalla Betta, P.
Combining the strengths of UMIST and The Victoria University of Manchester Conny Hansson, Supervisor: Prof. Robert. J. Cernik Funded by EPSRC Materials.
Sezione di Napoli Univ. “Federico II” Experimental study of beam hardening artefacts in photon counting breast computed tomography M.G. Bisogni a, A. Del.
Giorgio Russo National Research Council, Institute of Bioimaging and Molecular Imaging (IBFM) Fondazione Istituto San Raffaele G. Giglio di Cefalù Istituto.
PSD9, Aberystwyth, UK, 15 Sept Politecnico di Milano, Italy Development of a camera for imaging of prompt gamma rays in measurements.
PRAGUE November 2002 Monolithic Silicon Pixel Detectors in SOI Technology J. Marczewski, K. Domanski, P. Grabiec, M. Grodner,
Edoardo Cardelli – Dipartimento di Fisica – Università di Cagliari Università degli Studi di Cagliari Dipartimento di Fisica Detector Quality Control Edoardo.
Dante Nakazawa with Prof. Juan Collar
 Digital Mammography  X ray tests  Phantoms spectra  Bilateral Project (ICM-tube X-ray) Development of a silicon detector for photon counting to be.
Advanced GAmma Tracking Array
Torino Exploiting commercial CMOS technologies for:  detection of Minimum Ionizing Particles for High Energy Physics experiments  direct detection.
Introduction –Conventional radiology –Why digital? –Why dual energy? Experimental setup Image acquisition Image processing and results Dual energy radiology.
Imaging Properties of the Medipix2 System exploiting Single and Dual Energy Thresholds L. Tlustos 1, R. Ballabriga 1, M. Campbell 1, E. Heijne 1, k Kincade.
Hiroyasu Tajima Stanford Linear Accelerator Center Nov 3–8, 2002 VERTEX2002, Kailua-Kona, Hawaii Gamma-ray Polarimetry ~ Astrophysics Application ~
The performance of silicon detectors for the SiliPET project: A Small Animal PET Scanner based on Stacks of Silicon Detectors Natalia Auricchio, Giovanni.
Mass production testing of the front-end ASICs for the ALICE SDD system L. Toscano a, R. Arteche Diaz b,d, S. Di Liberto b, M.I. Martínez a,c, S.Martoiu.
Applications of a Pixellated Detection System to Digital Mammography
Recent advances on X-ray imaging with a single photon counting system I. Introduction II. The system: microstrip detectors, RX64 ASICs, testing methods.
Results about imaging with silicon strips for Angiography and Mammography I. Introduction II. The system: microstrip detectors, RX64 ASICs III. Energy.
The Magic Cube and the Pixel Ionization Chamber: detectors for monitor and dosimetry of radiotherapy beams S. Amerio 1, A. Boriano 2, F. Bourhaleb 2,3,
Imaging and spectroscopic performance studies of pixellated CdTe Timepix detector Dima Maneuski Vytautas Astromskas, Erik Fröjdh, Christer Fröjdh, Eva.
Experimental Setup of the H8-RD22 Experiment Massimiliano Fiorini (on behalf of the H8-RD22 Collaboration) University of Ferrara – INFN Ferrara CARE HHH.
H8-RD22 Experiment to test Crystal Collimation for the LHC Organized by: Walter Scandale Conducted at CERN Geneva, 27 September 2006 Participants included:
The High Resolution Array The High Resolution Array is a detector designed to detect and identify light charged particles like protons, deuterium, triton,
A PCI Card for Readout in High Energy Physics Experiments Michele Floris 1,2, Gianluca Usai 1,2, Davide Marras 2, André David IEEE Nuclear Science.
Performance of a 128 Channel counting mode ASIC for direct X-ray imaging A 128 channel counting ASIC has been developed for direct X-ray imaging purposes.
Performance limits of a 55  m pixel CdTe detector G.Pellegrini, M. Lozano, R. Martinez, M. Ullan Centro Nacional de Microelectronica, Barcelona, 08193,
Beam diagnostics in the beamlines
Beam Tests of 3D Vertically Interconnected Prototypes Matthew Jones (Purdue University) Grzegorz Deptuch, Scott Holm, Ryan Rivera, Lorenzo Uplegger (FNAL)
Introduction –Why digital? –Why dual energy? Experimental setup Image acquisition Image processing and results A silicon microstrip system with the RX64DTH.
CBM Silicon Tracking System. Microstrip Detector Module Assembly and Test V.M. Pugatch Kiev Institute for Nuclear Research GSI (CBM experiment), Darmstadt.
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
Update on the Triple GEM Detectors for Muon Tomography K. Gnanvo, M. Hohlmann, L. Grasso, A. Quintero Florida Institute of Technology, Melbourne, FL.
Hadronic interaction studies with the ARGO-YBJ experiment (5,800 m 2 ) 10 Pads (56 x 62 cm 2 ) for each RPC 8 Strips (6.5 x 62 cm 2 ) for each Pad ( 
JRA-1 ISRSI Consortium Meeting Perugia, INAF/IASF (BO,PA)
A Single Photon Emission Computer Tomograph for breast cancer imaging S. Vecchio a, N. Belcari a, P. Bennati b, M. Camarda a, R. Campanini c, M. N. Cinti.
The INFN Italy EXOTIC group Milano, Napoli, Padova, NIPNE Romania, Crakow Poland. Presented by C.Signorini Dept. of Physics and Astronomy Padova (Italy):
12 September 2006Silicon Strip Detector Readout Module J. Hoffmann SIDEREM SIlicon Strip DEtector REadout Module.
Introduction –Why digital? –Why dual energy? Experimental setup Image acquisition Image processing and results A silicon microstrip system with the RX64DTH.
August DESY-HH VFCAL Report W. Lohmann, DESY Infrastructure for sensor diagnostics FE Electronics Development Sensor test facilities Laser Alignment.
Progress with GaAs Pixel Detectors K.M.Smith University of Glasgow Acknowledgements: RD8 & RD19 (CERN Detector R.&D. collaboration) XIMAGE (Aixtron, I.M.C.,
FrontierScience G.P.1 MATRIX an innovative Pixel Ionization Chamber for Online Monitoring of Hadrontherapy Treatments Giuseppe Pittà.
1 MPGD2009 Advancements of labelled radio-pharmaceutics imaging with the PIM-MPGD J. Donnard a, N.Arlicot b,
Villa Olmo, Como October 2001F.Giordano1 SiTRD R & D The Silicon-TRD: Beam Test Results M.Brigida a, C.Favuzzi a, P.Fusco a, F.Gargano a, N.Giglietto.
DESCRIPTION OF PIXIRAD  The PIXIRAD Imaging Counter is an INFN-Pisa Spin-off  It works in photon counting  Pulse discrimination with two thresholds.
1 FANGS for BEAST J. Dingfelder, A. Eyring, Laura Mari, C. Marinas, D. Pohl University of Bonn
CdTe prototype detector testing Anja Schubert The University of Melbourne 9 May 2011 Updates.
Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation Josef Uher a,b, Jan Jakubek c a CSIRO.
First results of a novel silicon drift detector array designed for low energy X-ray fluorescence spectroscopy Alexandre Rachevski* a, Mahdi Ahangarianabhari.
PIXEL 2000 P.Netchaeva INFN Genova 0 Results on 0.7% X0 thick Pixel Modules for the ATLAS Detector. INFN Genova: R.Beccherle, G.Darbo, G.Gagliardi, C.Gemme,
Beam detectors in Au+Au run and future developments - Results of Aug 2012 Au+Au test – radiation damage - scCVD diamond detector with strip metalization.
Francesca Bisello Dosepix Midterm Review Preparatory Meeting ARDENT Project June 13th, CERN.
The design of fast analog channels for the readout of strip detectors in the inner layers of the SuperB SVT 1 INFN Sezione di Pavia I Pavia, Italy.
Progress with GaAs Pixel Detectors
Valerio Re Università di Bergamo and INFN, Pavia, Italy
H. Toyokawa1, C. Saji1, M. Kawase1, S. Wu1, Y. Furukawa1, K
INFN Pavia and University of Bergamo
A. Bergamaschi, A. Cervellino, R. Dinapoli, F. Gozzo, B. Henrich, I
M. C. Veale1, S. J. Bell1,2, D. D. Duarte1,2, M. J. French1, M
The Silicon Drift Detector of the ALICE Experiment
L. Ramello MIC-RTSD, Rome, 20 October 2004
Introduction Why digital? Why dual energy? Experimental setup
Status of n-XYTER read-out chain at GSI
L. Ramello MIC-RTSD, Rome, 20 October 2004
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
ME instrument and in-orbit performance
一种基于晶体间光分享原理的深度测量PET探测器
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Presentation transcript:

Silicon strip detectors for two-dimensional soft x-ray imaging at normal incidence Pedro Rato Mendes LIP Lisbon and University of Algarve, Portugal Amsterdam, September 2002

IWoRID AmsterdamPedro Rato Mendes et al. Outline Collaboration members Objectives Experimental setup Energy calibration Imaging results Conclusions and future work

IWoRID AmsterdamPedro Rato Mendes et al. Collaboration members M. C. Abreu a, G. Baldazzi b, D. Bollini b, E. Cabal Rodriguez c, W. Dabrowski d, A. Diaz Garcia c, M. Gambaccini e, P. Giubellino f, M. Gombia b, P. Grybos d, M. Idzik d,f, A. Marzari-Chiesa g, L. M. Montano h, F. Prino i, L. Ramello i, P. Rato Mendes a, S. Rodrigues a, M. Sitta i, P. Sousa a, K. Swientek d, A. Taibi e, A. Tuffanelli e, R. Wheadon f, P. Wiacek d a LIP and University of Algarve, Faro, Portugal b Dipartimento di Fisica dellUniversità di Bologna and INFN, Bologna, Italy c CEADEN, Havana, Cuba d Faculty of Physics and Nuclear Techniques, Academy of Mining and Metallurgy, Cracow, Poland e Dipartimento di Fisica dellUniversità di Ferrara and INFN, Ferrara, Italy f INFN, Torino, Italy g Dipartimento di Fisica Sperimentale dellUniversità di Torino and INFN, Torino, Italy h CINVESTAV, Mexico City, Mexico i Dipartimento di Scienze e Tecnologie Avanzate dellUniversità del Piemonte Orientale and INFN, Alessandria, Italy

IWoRID AmsterdamPedro Rato Mendes et al. Objectives Develop a simple prototype system for 2-D soft x-ray imaging using silicon strip detectors Motivations for this prototype –spin-off from high-energy physics –RX64 chip designed for this application –simple laboratory setup and data-acquisition –advanced education for young physicists RX64 and its main applications: talk by L. Ramello, this conference W. Dabrowski et al., RX64 – A Fully Integrated 64-channel IC for Readout of Silicon Detectors Used for X-Ray Position Sensitive Measurements, IEEE NSS/MIC 2001, San Diego

IWoRID AmsterdamPedro Rato Mendes et al. Experimental setup Equipment –board with 1-sided microstrip detectors and RX64 chips 300 m thick Si, 132 strips at 100 m pitch (ITC-IRST, Trento, Italy) RX64 chip by W. Dabrowski and collaborators (Cracow, Poland) one or two chips per board (64 or 128 channels) –PC with NI PCI-DIO-96 interface + LabVIEW 6i software –scanning system controlled by stepper motor –radiation sources ( 57 Co, 109 Cd, 241 Am for fluorescence) –power supplies, cables Two-dimensional image acquisition –acquire 1-D profiles for each collimator position –form 2-D image by juxtaposition of 1-D profiles

IWoRID AmsterdamPedro Rato Mendes et al. Experimental setup 64 silicon microstrip detector RX channels (preamp, shaper, discriminator) - 64 pseudo-random counters (20-bit) - internal calibration circuit (1 mV to 30 mV) - I/O on chip (interface with external bus) PC National Instruments PCI-DIO-96 LabVIEW 6i

IWoRID AmsterdamPedro Rato Mendes et al. First test board (one RX64 chip) cm 2 detector RX64

IWoRID AmsterdamPedro Rato Mendes et al. Energy calibration Method –perform discriminator threshold scan –differentiate integral spectrum –fit energy peaks on differential spectrum integral spectrum differential spectrum

IWoRID AmsterdamPedro Rato Mendes et al. Energy calibration Calibration using Co57 and Cd109 sources (board with one RX64 chip, average on all channels)

IWoRID AmsterdamPedro Rato Mendes et al. Energy calibration Calibration using Am241 x-ray fluorescence source (board with two RX64 chips, average on all channels)

IWoRID AmsterdamPedro Rato Mendes et al. Scanning system scanning detector board stepper motor radioactive source Pb collimator

IWoRID AmsterdamPedro Rato Mendes et al. Imaging results – one RX64 chip Pb 0.5 mm thick 300 kBq 109 Cd source – 22 keV Ag K x-rays 15 mm thick Pb collimator, 300 µm wide slit microstrip detector scanning system mm 2

IWoRID AmsterdamPedro Rato Mendes et al. Imaging results – two RX64 chips 300 kBq 109 Cd source – 22 keV Ag K x-rays 15 mm thick Pb collimator, 300 µm wide slit LOW CONTRAST snail shell HIGH CONTRAST 8-pin integrated circuit mm 2

IWoRID AmsterdamPedro Rato Mendes et al. Conclusions Prototype main features –one-sided silicon microstrip detectors –simple readout electronics based on RX64 chip –simple 2-D scanning system Future developments –larger area sensors / more readout chips –new chip version with two thresholds –x-ray tube as radiation source We have built and tested a simple prototype for 2-D soft x-ray imaging