Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing INSTALLING STICK DOWN FLOORS WITH PVC.

Slides:



Advertisements
Similar presentations
Sectional Assembly and Installation
Advertisements

NGfL CYMRU GCaD FLOOR COVERINGS.
Interior Wall and Ceiling Finish
Internal Use Only – Do Not Distribute CONFIDENTIAL How to install Laminate or Formica on SmartBOARD?
Easi-Sterilise Standard Operating Procedures & Workplace Skills Assessments Getting it right, every step of the way.
2313 W Sam Houston Parkway N Suite 105 Houston, Texas ROK Shield Application Instructions ROK Shield is a non-toxic,
NGfL CYMRU GCaD FLOOR SCREEDING, PLASTERING AND RENDERING.
Method to fix wall tiles. Preparation All wall tiles to be immersed in water for 3-4 hours for better results. Some gap in between the rows to allow the.
Grouting Ceramic Tile This step comes after the tile is installed and has had time to cure. It is very important to either follow the instructions listed.
ICRA Panel System Installation Instructions
Spiral Stairs Assembly Instruction By Laser Dollhouse Designs
Heating foil ECOFILM F Installation guide. ECOFILM F - OPTION Suitable for laminate floating floors: width(mm) input (W/m 2 ) F F (48V) 530.
SEACORK INSTALLATION ON A CATAMARAN The first step is to make templates of all corner pieces to be cut from sheet material, which will be used for border.
By David Sheil Wood manufacturing and finishing 2013.
1 Welding Module 10. 2Objectives After this module you should be able to – identify the most common welding hazards – take the necessary steps to avoid.
Direct heating system ECOFLOOR Installation guide.
Step 1: Prepare the surface The floor should be clean, dry, flat and sound. The floor should be free from oily/waxy or curing compounds.
Dry lining by direct bond – overview
Connector match the key words with their meanings Silicosis Slurry Manipulate ‘Pinch or thumb’ pot To mould or shape something Name given because you use.
INDUSTRIAL FLOOR SHEETING_. Industrial Floor Sheeting  INTRODUCTION_  BENEFITS_  SUGGESTED SPECIFICATION_  INSTALLATION INSTRUCTIONS_  MAINTENANCE.
FLOORFLEX VINYL TILES_. Floorflex Vinyl Tiles  INTRODUCTION_  BENEFITS_  SUGGESTED SPECIFICATION_  INSTALLATION INSTRUCTIONS_  MAINTENANCE PROCEDURES_.
SUPERFLEX VINYL TILES & SHEETING_. Superflex Vinyl Tiles & Sheeting  INTRODUCTION_  BENEFITS_  SUGGESTED SPECIFICATION_  INSTALLATION INSTRUCTIONS_.
FLOORWORX SD VINYL TILES & SHEETING_.  INTRODUCTION_  BENEFITS_  SUGGESTED SPECIFICATION_  INSTALLATION INSTRUCTIONS_  MAINTENANCE PROCEDURES_ 
MOUNTING PHOTOS FOR STATE FAIR
RENAISSANC E CARPET TILES_.  INTRODUCTION_  BENEFITS_  SUGGESTED SPECIFICATION_  INSTALLATION INSTRUCTIONS_  MAINTENANCE PROCEDURES_  TECHNICAL.
PRIMO SD VINYL TILES & SHEETING_.  INTRODUCTION_  BENEFITS_  SUGGESTED SPECIFICATION_  INSTALLATION INSTRUCTIONS_  MAINTENANCE PROCEDURES_  TECHNICAL.
START VINYL SHEETING_.  INTRODUCTION_  BENEFITS_  SUGGESTED SPECIFICATION_  INSTALLATION INSTRUCTIONS_  MAINTENANCE PROCEDURES_  TECHNICAL PROPERTIES_.
TAKE NOTE ON THE ORDER OF PROCEDURE FOR CONSTRUCTION OF THE LAMINATE COUNTERTOP. Countertop Procedures.
BILBOND H 4545 Formerly Bhavi International Ltd.
COLORFLOR STANDARD.  INTRODUCTION_  BENEFITS_  SUGGESTED SPECIFICATION_  INSTALLATION INSTRUCTIONS_  MAINTENANCE PROCEDURES_  TECHNICAL PROPERTIES_.
Basic Slide Show Under Tile Spooled Heating Installation Guide.
COMPACT SHEETING SARLON COMPACT UNI. INTRODUCTION  Compact vinyl flooring contribute to lowering noise disturbance within a building in a number of ways.
HOMOGENEOUS VINYL TILES & SHEETING COLORFLOR STANDARD.
Set Mat DIY Installation instructions Beautifully warm floors for New Homes and Renovations Tiles: Granite: Marble: Parquet: Vinyl: Cork: Included in each.
COMPACT SHEETING ETERNAL MARBLE. INTRODUCTION  Eternal is a compact heterogeneous vinyl floor covering with a calendared backing in 2m wide sheeting.
ENTRANCE SYSTEMS CORAL WELCOME & DUO. INTRODUCTION  A good quality entrance system provides a very effective way to reduce cleaning costs, preventing.
RUBBER TILES NORAMENT 825. INTRODUCTION  FloorworX partners with nora® to bring South Africa sustainable commercial rubber flooring solutions  Ergonomic,
COMPACT SHEETING SURESTEP STAR. INTRODUCTION  Surestep is a 2m wide glass fibre-mat reinforced compact antistatic vinyl floor covering, featuring a 0.7mm.
HOMOGENEOUS VINYL TILES & SHEETING ELITE PUR. INTRODUCTION  Homogeneous vinyl flooring has a uniform structure and composition from the top to the bottom.
ACOUSTIC SHEETING SARLON TRAFIC TOPOGRAPHY. INTRODUCTION  Acoustic floors are best way to reduce noise in buildings  The thickness of the concrete slab.
STATIC CONTROL TILES & SHEETING PRIMO SD. INTRODUCTION  Static Dissipative flooring is essential for protecting sensitive equipment from static charge.
Potting Bench Plans Matt Howell Brooks County High School ___, Georgia Georgia Agricultural Education Curriculum Office, August, 2004.
SPORT SHEETING START. INTRODUCTION  Sports and other regular physical exercise offer numerous benefits to the human body  However, an important factor.
Create decorative backsplashes, accent walls, or other focal points
SURESTEP ORIGINAL COMPACT SHEETING.
SARLON TRAFIC WOOD ACOUSTIC SHEETING.
SUPERFLEX HOMOGENEOUS VINYL TILES & SHEETING.
Linoleum Installation System
Grouting Armstrong Alterna Tile
RENAISSANCE CARPET TILES POLYPROPYLENE CARPET TILES.
Board Replacement for Floating Floors
ECLIPSE PUR HOMOGENEOUS VINYL TILES & SHEETING.
ETERNAL SAND COMPACT SHEETING.
INDUSTRIAL FLOOR HOMOGENEOUS VINYL SHEETING.
ETERNAL STONE COMPACT SHEETING.
SARLON TRAFIC FLASH CODE XXL ACOUSTIC SHEETING.
WALLCLADDING SHEETING_
FLOORWORX SD STATIC CONTROL TILES & SHEETING.
ETERNAL SMARAGD COMPACT SHEETING.
Acczent Unik Installation Instructions
Installation Instructions Acczent Classic 40, Meteor 70,
ProtectWALL: 1,5 mm & 2 CR Installation Instructions
Tapiflex Self-adhesive
Card Sort: Making a ‘pinch pot’
CANVAS PUR HOMOGENEOUS VINYL SHEETING.
SARLON TRAFIC CODE BARRES XXL ACOUSTIC SHEETING.
SARLON TRAFIC VISION 3D ACOUSTIC SHEETING.
ETERNAL PALETTE COMPACT SHEETING.
SARLON TRAFIC CRISTAL ACOUSTIC SHEETING.
SARLON TRAFIC CODE ZERO XXL ACOUSTIC SHEETING.
Presentation transcript:

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing INSTALLING STICK DOWN FLOORS WITH PVC BACKING WoodComfort glue down HPS (Series 4000) CorkComfort glue down HPS (Series 2000)

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing Transport and store the cartons in laying position Store the tiles at room temperature for at least 48 hours, still in their packaging, prior to commencing work. Do not remove the plastic wrapping from the packaging until ready to install the floor. The room temperature must be at least 18ºC (65ºF) before and during installation. GENERAL INFORMATION Please read these instructions thoroughly in conjunction with relevant country standards before starting the installation. Transport, storage and acclimatisation:

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing Amorim cannot be held responsible for claims associated with improper sub-floors or applications, or the use of any auxiliary products that are not recommended. Inspection: Prior to installation, please inspect the tiles in daylight for any visible faults or damage, and also check if the subfloor and site conditions are in accordance with the specifications described within these instructions If you are not satisfied do not install, and contact your supplier

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing Subfloor requirements : A. R. stick down floors with PVC backing can be installed in interior installation sites to on or above grade concrete or wooden sub-floors General: In the case of any other type of subfloor, please contact your supplier The subfloor must be levelled, permanently dry, clean and free from anything that may impair adhesion Use only primers and levelling compounds suitable for the existing subfloor. For A. R. stick down floors with PVC backing, the surface temperature of the subfloor must not exceed 28°C (82°F) Radiant-Heated Subfloors: For detailed information, follow the instructions supplied by the subfloor heating system manufacturer/contractor or contact your supplier.

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing Moisture protection: Despite it's age there is always a risk of moisture in subfloors For that reason it is necessary to ensure that an efficient moisture barrier is installed The moisture content of concrete subfloors should be as indicated below (when using a CM measuring instrument): Cement-screed without floor heating:> 2,0 CM% with integrated floor heating: > 0,5 CM% Gypsum/Anhydrite-screed without floor heating:> 0,5 CM% with integrated floor heating: > 0,3 CM%

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing Preventive care: If works will take place in the room where the floor is installed, protect with craft paper, plywood or hardboard Do not drag furniture across the floor Use felt pads on chair and furniture legs Office roller chairs must comply with DIN Place quality walk-off mats at all entrances to retain tracked in dirt, grit and moisture Never use latex or rubber backed mats as they can permanently stain the floor Avoid moisture on the floor

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing Ideal and healthy room conditions are % R.H. at 20°C (68°F) When using intensive room heating, the indoor air humidity may drop so low that the floor is prone to dry out As cork and wood are natural material, this may cause shrinkage of the tiles that will result in minor gaps in the flooring joints - use a room humidifier to prevent this Cork as a natural material may tend to fade, Wood as a natural material may tend to mellow/darken when exposed to sunlight- use blinds, curtains or other sunscreening system to minimise this effect.

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing Tools required: Recommended notched trowel Tape measure Craft knife Pencil Straight edge Chalk line Cloth Rubber hammer 50 Kgs Multi-Part roller

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing If laying in diagonal, mark two diagonal lines starting from the intersection point, dividing the 90º angle in half (forming like this a 45º angle). Measurements: Find the centre of the room using a chalk line, from the middle of wall A to the middle of A1, then make a line from the middle of wall B to the middle of wall B1 Check that the intersection of the two lines forms a 90° angle If necessary repeat the previous step by drawing new parallel lines to the first ones Measurement check: Check the room dimension by measuring or placing the tiles (without gluing), from the middle Make sure that the widths of the tiles that will be near the wall are identical and greater than 5 cm

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing Laying: Only use Wicanders W-336 adhesive for installation (wet set method) and recommended notched trowel (A2) Follow the instructions on the adhesive package Install the tiles from the centre along the marked line, preferably using "brick-bond" system Place tiles side by side without pushing too tightly together Lightly press each tile down by hand Remove any excess adhesive with a damp cloth or white spirit.

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing In order to ensure adhesion, spread only adhesive on an area which can be installed within the recommended adhesive open time. Important: The backing of the tiles has to be moistened with adhesive to ensure a good adhesion _ check this by lifting one tile. Adhesive transfer: After each section has been laid and tiles do not slide underfoot (approx. 30 min.), the floor must be rolled diagonally with a multi-part roller (minimum 50 kg) to ensure complete transference of the adhesive to the tile backing Rolling the floor: Roll again the entire area after completion of installation

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing Cut the tiles near the wall as indicated Last row Seal the edges by using a D3 class PVA adhesive (ex. Wicanders W-185) or another type of suitable edge sealer. On-site cutting: Each tile has sealed edges Whenever you cut a tile, the edges become unprotected

Amorim Revestimentos, S.A. Professional Training Product Management Installing stick down floors with PVC backing For correct use follow the instructions on the packaging labels of each product. Cleaning and Maintenance Use only the recommended products