29.9.2010Jiri Kvasnicka, EUDET meeting at DESY 1 Optical fibre calibration system Jiri Kvasnicka Outline Results from recent tests – LAB Test.

Slides:



Advertisements
Similar presentations
1 Electronics Simulation in the Photon Transport Monte Carlo Preamp model Receiver/discriminator circuit CAFÉ driver circuit model Examples Summary January.
Advertisements

1 Review of AC Circuits Smith College, EGR 325 March 27, 2006.
HH Dec 13Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1.
Optical Fiber Calibration System and Adaptive Power Supply Jiri Kvasnicka, Ivo Polak, Jaroslav Cvach Prague, Institute of Physics Gerald Eigen,
LED calibration systems for CALICE hadron calorimeter June 11, 2011TIPP 2011, Chicago1.
Electromagnetic shower in the AHCAL selection criteria data / MonteCarlo comparison of: handling linearity shower shapes CALICE collaboration meeting may.
AHCAL Saturation Study CALICE week – Casablanca, Morocco 2010/09/22 Jaroslav Zalesak Institute of Physics, Prague / DESY Study of single SiPM response.
The first testing of the CERC and PCB Version II with cosmic rays Catherine Fry Imperial College London CALICE Meeting, CERN 28 th – 29 th June 2004 Prototype.
LCWS2010, Beijing, 2010 MAR29 Ivo Polák, FZU, Prague1 LED notched fibre system at AHCAL Calibration system for SiPM Ivo Polák 1.Notched fibre.
Calice, UT ArlingtonJiri Kvasnicka, FZU, Prague1 LED notched fiber system Jiri Kvasnicka 1.Introduction 2.Test setup and fiber layout on HBU0.
Ivo Polák SiPM needs short optical pulses
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka, Ivo Polak Institute of Physics (FZU), Prague June 11, 2011TIPP 2011, Kvasnicka1 The.
ECFA, JUN10, 2008Ivo Polak, IPASCR, Prague1 Electronics part of AHCAL calibration system ECFA meeting at Warszawa.
ECAL electronics Guido Haefeli, Lausanne PEBS meeting 10.Jan
External calibration system - QMB6 Distribution of light: Notched Fiber Calibration and Monitoring Board (CMB) 1-ch LED driver (QMB1) Calibration System.
DESY, DEC-2013Ivo Polák, FZU, Prague1 Activity on Adaptive power & Calibration at Prague Ivo Polák, on behalf of Prague’s group QMB1A update.
Tests of the fiber-based calibration system CALICE collaboration meeting Cambridge, UK 2012/9/18 Jaroslav Zalesak Institute of Physics, Prague  QMB1 LED.
Mathias Reinecke CALICE meeting Argonne EUDET module – Electronics Integration Contents -Next prototype : architecture -HCAL Base Unit (HBU)
Feb 20, 2009 CALICE meeting, Daegu, Korea QRL in Magnetic Field 1 QRLed Driver in Magnetic Field Jaroslav Zalesak Institute of Physics of the ASCR, Prague.
Optical calibration system for EUDET AHCAL module Jaroslav Cvach IPASCR 1.Calibration system for SiPM photodetectors 2.QRLED driver photoelectron spectra.
AHCAL – Electromechanical Integration EUDET annual meeting – Paris Oct M. Reinecke.
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka Institute of Physics, Prague June 11, 2011TIPP 2011, Chicago1 Under.
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
LED calibration systems for CALICE hadron calorimeter
AHCAL Electronics. Front-end electronics and DAQ Mathias Reinecke CALICE meeting Hamburg March 21st, 2013.
06/03/06Calice TB preparation1 HCAL test beam monitoring - online plots & fast analysis - - what do we want to monitor - how do we want to store & communicate.
Uni Bergen:G. Eigen, J. Zalieckas, E. van der Kraaij FZU Prague: J. Cvach, J. Kvasnicka, I. Polák CALICE meeting, Argonne, 19/03/2014.
AHCAL Electronics. Status Commissioning and Integration Peter Göttlicher for the AHCAL developers CALICE meeting UT Arlington, March 12th, 2010.
Calibration UV LED system for CALICE scintillator based Tile Hadron Calorimeter Ivo Polák on behalf of the CALICE Collaboration Institute of Physics of.
LCWA, ALCPG 2009 Albuquerque, NM Ivo Polák, FZU, Prague1 Calibration system of CALICE AHCAL detector Ivo Polák 1.Two calibration light distribution.
AHCAL Electronics. Status and Outlook Mathias Reinecke CALICE collaboration meeting Cambridge, UK March 16th-19th, 2012.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Munich, 18 Oct 2006J. Cvach, annual JRA31 JRA3 Institute of Physics ASCR Prague 1.ECAL, VFCAL (V. Vrba) 2.HCAL (J. Cvach) 3.Exchange in NA2 (travels 8.5.
1. DESY tests 2. Electronics developments 3. Optical developments 4. Outlook Casablanca J. Cvach, CALICE Coll. meeting.
Montpellier, November 15, 2003 J. Cvach, TileHCAL and APD readout1 TileHCAL- fibre readout by APD APDs and preamplifiers Energy scan with DESY beam –Energy.
Uni Bergen:G. Eigen, E. van der Kraaij, J. Zalieckas FZU Prague: J. Cvach, J. Kvasnička, I. Polák Linear Collider Workshop, Tokyo 13/11/2013.
Scintillator tile-SiPM system development for CALICE Engineering AHCAL Prototype Michael Danilov, ITEP & CALICE LCWS10 Beijing March 2010 Outline New scintillator.
Optical Part of the CMB for AHCAL-CALICE Jaroslav Zalesak Institute of Physics, Prague.
R&D for a 2nd generation AHCAL prototype LCWS 2007 – DESY Hamburg Mathias Reinecke on behalf of the AHCAL partners.
May - 20Ivo Polák, FZU, Prague1 LED notched fibre distributing system Calibration system for SiPM Ivo Polák, on behalf prague’s group
5 July 2010Ivo Polák, FZU, Prague LED notched fibre distributing system Calibration system for SiPM Ivo Polák, Ji ř í Kvasni č ka
AHCAL Electronics. Status Commissioning Mathias Reinecke for the AHCAL developers HCAL main meeting Hamburg, Dec. 10th, 2009.
AHCAL Electronics. SPIROC2 and HBU measurement results Mathias Reinecke CALICE main meeting Univ. HASSAN II, Casablanca, Morocco Sept. 23rd, 2010.
oct - 6Ivo Polák, FZU, Prague1 Calibration system for SiPM and LED notched fibre distributing system Ivo Polák, on behalf prague’s group
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka, Ivo Polak, Institute of Physics, Prague June 11, 2011TIPP 2011, Kvasnicka1 The CALICE.
Gain stability and the LYSO beam radiation monitor measurements
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
Scintillator tile – SiPM development at ITEP Michael Danilov, ITEP CALICE Meeting, Casablanca, 23 Sep 2010.
Main HCAL, JUL1,2008Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers HCAL main meeting, DESY.
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
Calibration issues for the CALICE 1m3 AHCAL ALCPG11 - Linear Collider Workshop of the Americas Eugene, Oregon, USA 2011/3/22 Jaroslav Zalesak Institute.
Status of the PSD upgrade - Status of the PSD cooling and temperature stabilization system - MAPD gain monitoring system - PSD readout upgrade F.Guber,
ShinShu, 2012 Mar 6Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 with HBU2 test Ivo Polák, on behalf of Prague’s group
AHCAL Electronics. integration status and open issues Mathias Reinecke CALICE main meeting Univ. HASSAN II, Casablanca, Morocco Sept. 23rd, 2010.
2011 Sept 14-16Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1.
G. Eigen, Paris, Introduction The SiPM response is non-linear and depends on operating voltage (V-V bd ) and temperature  SiPMs need monitoring.
Annual EUDET, OCT6,2008 Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers for AHCAL EUDET annual meeting, NIKHEF 1.Introduction 2.QRLed.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
AHCAL Electronics. Status of Integration Mathias Reinecke for the DESY AHCAL developers AHCAL main and analysis meeting Hamburg, July 16th and 17th, 2009.
AHCAL Electronics. Status Commissioning Mathias Reinecke for the AHCAL developers EUDET electronics and DAQ meeting Paris Palaiseau, Jan. 14th, 2010.
AHCAL Electronics. status and open issues Mathias Reinecke CALICE ECAL/AHCAL - EUDET electronics and DAQ - AIDA DESY, July 5th to 6th, 2010.
LED notched fibre distributing system Calibration system for SiPM
LED notched fibre system short HBU0 party with QMB6
LED notched fibre system at AHCAL Calibration system for SiPM
Felix Sefkow CALICE/EUDET electronics meeting CERN, July 12, 2007
Status of the EUDET Prototype
Testbeam analysis on module #1
Scintillator HCal Prototype
Presentation transcript:

Jiri Kvasnicka, EUDET meeting at DESY 1 Optical fibre calibration system Jiri Kvasnicka Outline Results from recent tests – LAB Test in December 2009 – LAB Test in April 2010 – Test at Testbeam DESY 2010 Optical & electronics development

Jiri Kvasnicka, EUDET meeting at DESY 2 QMB6 (6-channel QR LED driver Main Board) 6 channels of QR LED driver Fixed pulse width, steerable amplitude 2 preamps for PinPhoto Diode Arm7 Microcontroller Canbus/dip-switch control Internal/TTL /LVDS trigger Temperature and voltage monitoring Single +15V power supply with onboard regulators

Jiri Kvasnicka, EUDET meeting at DESY 3 First test with fibre – plan Original plan was to use a special holes in the SPIROC1 HBU0 area 2 routes with holes exist in SPIROC1 area, each having a different distance among holes Special fibre was manufactured for each route Spiroc1 Spiroc2 Illuminated fibre HBU 0

Jiri Kvasnicka, EUDET meeting at DESY 4 Test setup in Dec 2009 We made an improvised setup Optimized criterion – maximize number of illuminated tiles through all holes (alignment pin, holes for integrated LED) Fibre fixed with strips of tape Illuminating notched fibre HBU0

Jiri Kvasnicka, EUDET meeting at DESY 5 Topological map of 12×6 scint. tiles. Each square represents mean of a fit to SPIROC2 ADC spectrum (low gain mode, Cf=400fF) First data – trace from the fibre Pure ADC data, no gain correction

Jiri Kvasnicka, EUDET meeting at DESY 6 Optical Crosstalk? – Dec 2009 Signal contribution from the neighboring tiles (noise) Possible reason: notches of the fiber were uncovered and shined under the cover Fine scale of the topological map of 12×6 scint. tiles. Each square represents mean of a fit to SPIROC2 ADC spectrum (low gain mode, Cf=400fF) Amplitude [ADC count]

Jiri Kvasnicka, EUDET meeting at DESY 7 Dec 2009 summary We achieve to measure a nice single P.E. spectra, even with low statistics We identified the fibre track on HBU0 We faced a big optical crosstalk No saturation visible in the scan over the V1 setting of QMB6 Test of electrical crosstalk (QMB6 HBU0) showed no such effect

Jiri Kvasnicka, EUDET meeting at DESY 8 Tests with fibre holder – April 2010 The fibre was held straight by a Balsa wood support Holes in the balsa used for correct placing on to of the HBU0 Balsa wood – it was only for the test! We used a fibre with regular. It did not fit the tile alignment pin holes (on HBU0) properly. Dec 2009 – alignment problem April 2010 – balsa support

thursday HCAL, DESYIvo Polák, FZU, Prague9 QMB6 + HBU0: optofibre-Balsa fixation

Jiri Kvasnicka, EUDET meeting at DESY 10 Single PE spectrum – April 2010 HG mode, 100fF feedback capacitance Statistics of 50K events Distance measured by hand Big spread of single_photon_peak distance [ADC count / pixel] among the channels SiPM voltage settings wrong? ASIC1 ASIC0 Fibre end

Jiri Kvasnicka, EUDET meeting at DESY 11 Amplitude scan – April 2010 RAW ADC data ! Scan at LG, 400fF ASIC should not be saturated (range up to 4095 bins) Results have to be calibrated: 1.Single PE peak distance 2.HG/LG ratio 3.LED optical power Fibre end

Jiri Kvasnicka, EUDET meeting at DESY 12 HG vs LG radio measurements – April st measurements were measured only in one fixed amplitude. Analysis showed, that some channels were saturated in HG mode. Therefore: we scanned the ratio in several (optical) amplitudes Data were taken at amplitudes, where –Signal is not saturated in HG mode –Signal is still reasonably high in LG mode Pedestal shifts during measurement! Discovered later, described here at following slides Old data 29/4/2010 Big syst. error New gain measurement

Jiri Kvasnicka, EUDET meeting at DESY 13 Amplitude scan calibrated to pixels From the distance between single photon peaks and from the HG vs. LG ratio, we are able to estimate the number of fired pixels New recalculation: –delivered optical power from the fibre is much more consistent –Curves are less crossing each other Next step (next slide): convert V1 value to optical power (energy) Presented 29/4/2010, DESY Recalculated gain Fibre end

Jiri Kvasnicka, EUDET meeting at DESY 14 Optical performance at Prague lab Equipment at Prague: Flashing with 10kHz, measurement device: Thorlabs PM100D & S130VC Slope is not linear, especially at very low amplitudes due to electrical properties of the QR driver concept Reason of non-linearity: energy is stored in the inductor and the peak voltage has to rise above the V2 and the voltage drop of the UV LED 5mm LED3mm LED

Jiri Kvasnicka, EUDET meeting at DESY 15 Amplitude scan corrected (2) – April 2010 Linear extrapolation of the initial slope indicate the dynamic range of ~200 MIPs with 12-notched fibre Final comments: The estimated number of fired pixels is larger than the real number of SiPM pixels Different shapes of saturation curve might indicate improper HG vs LG ratio Saturation curves does not match simple f(x)=1-exp(-x) function (unsuccessful fit)

Jiri Kvasnicka, EUDET meeting at DESY 16 Eudet TB setup – Jul 2010,DESY ASIC0 (green) fully working Problems with ASIC1 (red) programming Beam trigger: coincidence of PMTs Channels were illuminated by the notched fibre Control: Labview DIF + QMB6 labview control Modes of operation: –Trigger from beam trigger –Internal DIF trigger –Autotrigger not working at that time Measured data: –MIP signal in High gain and Low gain (channels ) –Gain between MIP in HG and LG using MIP signal (channels ) –Scan over various V1 setting of the QMB6 –Scan of the hold value –Scan over the period if the internal trigger

Jiri Kvasnicka, EUDET meeting at DESY 17 Gain calibration – MIP signal Clear single P.E. spectrum observed only at channel 31. Other channels too noisy (?) pedestal from beaming of the tile 30 Gain between HG and LG stable within 3-5% among all memory cells. Ratio HG/LG – important for calibration –MIP signal in High Gain and Low Gain –spread over ASIC channels –spread over memory cells (analysis error?) –ratio channel dependent and > 10(?) –Important parameter for energy scale setting Peaks are aligned

Jiri Kvasnicka, EUDET meeting at DESY 18 DESY test at TB – preliminary result o scan over various V1 setting of the QMB6, (0 – 4000) o ASIC ADC values averaged over a run o reference value (green) - last filled memory cell o decrease of pedestal during filling! V1 ADC Filling time Memory cells Readout value shift [ADC bin] Not saturated Saturated Reference cells (zero level) Always zero (ASIC BUG) Analogue memory cells filling 1 ASIC channel – high gain:

Jiri Kvasnicka, EUDET meeting at DESY 19 Pedestal shift Inconsistence among the analog memory cells – hard to predict the shift 1 dead channel discovered in ASIC1 (Ch. 3) 1 bad tile/channel (Ch. 34) – no response even at the beam Large pedestal shift in High gain Data analysis still in progress 1 row of cell iluminated: zoom Memory cells Readout value shift [ADC bin] Not saturated Saturated Reference cells (zero level) Allways zero (ASIC BUG) ASIC saturation Optical crosstalk? Iluminated Tile 34 Optical Crosstalk? Dead Ch Saturation point

Jiri Kvasnicka, EUDET meeting at DESY 20 Optical developments Full length plane = 72 tiles in row Production of 1 fibre with 72 notches is tedious and expensive Agreement reached: 3 parallel fibres, each one with 24 notches (1 fibre for 2 HBUs) For final calorimeter we plan to use full length fibre with 72 notches – automation needed Order placed to SAFIBRA comp.: by the end of 2010 we shall get and test the first set of 3 fibres, beginning of 2011 – 3 more sets will be delivered HBU6HBU5HBU4HBU3HBU2HBU1 2 HBUs = 1 fibre with 24 notches 3 fibres receive light from 1 LED

Jiri Kvasnicka, EUDET meeting at DESY 21 1 LED for more fibres – distribution of light intensity on the LED surface? We scanned a 3 mm LED S130VC by the THORLAB set up + PM100D Light intensity shows asymmetry (chip position) – inhomogeneity ±10% ±15% observed for 5 mm LEDs used in 1m 3 HCAL calibration system Not a problem - inhomegeneity from notched fibres on ±20% level Light intensity – surface 3 mm LED LED 3D fibre holder sensor PM100D fibre Optical developments 2

Jiri Kvasnicka, EUDET meeting at DESY 22 Electronics development Higher inductance improves linearity behaviour of the of the QRLED driver How to increase L? o toroid size: 11 and 9 coil turns, and diameter o thickness of PCB: 0.8, 1.2, 1.8, 3.2 mm o GND-plane geometry Inductance L measured via resonance frequency with parallel capacitance C (200 pF) o accuracy needs improvement o dominant effect of PCB thickness o impact of the coil diameter? - still to be tested Next version of the LED driver – modular based on single channel modules BCED GHIJ GND L C present QMB6

Jiri Kvasnicka, EUDET meeting at DESY 23 Outlook Focus: increase of the optical performance: increase of the pulse width from the current 3.5 ns Improvement of the optical coupling from LED into the fibre Improvement of the transmission to the scintillation tile New QR LED driver prototype envisaged only 1 electronic channel per board different onboard inductors for different pulse width in range of 4 ~ 10 ns 3cm PCB width to match the tile size Notched fibre production (Q4/10-Q1/11) 4 sets by 3 notched fibres each with 24 notches Thanks to my Prague colleagues J. Cvach, M. Janata, I. Polák, J. Smolík and M. Reinecke, M. Terwort and J. Zálešák for DESY tests support!

Jiri Kvasnicka, EUDET meeting at DESY 24 Thank you for your attention Questions?

Jiri Kvasnicka, EUDET meeting at DESY 25 ONOFF QMB6 ON/OFF test – Dec 2009 ON ON means T-calib on, LED off OFF OFF means +15V power off NO pedestal shift NO unwanted ground coupling

Jiri Kvasnicka, EUDET meeting at DESY 26 Backup: Multi-peaks of non-tuned LEDs steps in DNL graph correspond to secondary peaks. These peaks are unwanted, because they make optical pulse longer. Reason: incorrectly damped resonance of QRLED driver Derivation of the amplitude scan

Jiri Kvasnicka, EUDET meeting at DESY 27

Jiri Kvasnicka, EUDET meeting at DESY 28