Medical Ultrasound: Image Optimisation

Slides:



Advertisements
Similar presentations
Chapter3 Pulse-Echo Ultrasound Instrumentation
Advertisements

Doppler Echocardiography
Doppler Echocardiography
Foundations of Medical Ultrasonic Imaging
Doppler Ultrasound: Principles
There are three major types of Blood flow Doppler patterns: 1) Continuous Wave 2) Pulse Wave 3) Color Flow DOPPLER ULTRASOUND.
إعداد : أ. بلسم فهد صوفي 1 Ultrasound in Medicine Ch.3 Ultrasound pictures of the body.
Ultrasound machine knobology
إعداد : أ. بلسم فهد صوفي،،،المصدر:محاضرات د.حنان 1 Ultrasound in Medicine Ch.4 Ultrasound pictures of the body.
Resident Physics Lectures
Hospital Physics Group
Ultrasound Physics Have no fear Presentation by Alexis Palley MD
EPOCH 1000 Series Procedure Phase Array Straight Beam Calibration
ECE 501 Introduction to BME
Ultrasound Imaging Atam Dhawan.
Ultrasound Spring 2009 Student Final. Ultrasound AKA: 1)Diagnostic Medical Sonography 2)Sonography3) 4) Vascular Sonography 5)Echocardiography.
Sound In Medicine. Sound waves Sound is a mechanical waves travel in air as longitudinal waves in which vibrations in air causes increases (compressions)
Ultrasound – Physics & Advances
DOPPLER SONOGRAPHY By Dr/ Dina Metwaly.
Development of an Ultrasound Lab Laura Wade April 4 th Z.
THE ULTRASOUND IMAGE: GENERATION AND DISPLAY
Ultrasound Physics Sound is a mechanical, longitudinal wave that travels in a straight line Sound requires a medium through which to travel Ultrasound.
Ultrasonography.
Toshiba Medical Systems Safety in Ultrasound and Image manipulation Erica Oliver Clinical Product Specialist Ultrasound.
3/13/2009IB Physics HL 21 Ultrasound Medical Imaging Physics – IB Objectives I.2.7Describe the principles of the generation and the detection of ultrasound.
Ultrasound Spring 2013 Week 7 RT 255 C. Ultrasound AKA: 1)Diagnostic Medical Sonography 2)Sonography3)Ultrasonography 4)Vascular Sonography 5)Echocardiography.
Resident Categorical Course
1 March 2013 PGI Chandigarh Dr Sarvesh Natani.
Dr Mohamed el Safwany, MD..  The student should learn at the end of this lecture medical ultrasound imging.
US FUNDAMENTALS: B-MODE AND DOPPLER MACHINE SETTINGS.
Display of Motion & Doppler Ultrasound
Review of Ultrasonic Imaging
Sarah Gillies Ultrasound Sarah Gillies
Introduction to the Physics Echocardiography Introduction to the Physics Echocardiography Jose L. Rivera, M.D. January 9, 2010.
Doppler Ultrasound Dr Mohamed El Safwany, MD.. Introduction The Doppler Effect refers to the change in frequency that results when either the detector/observer.
EPOCH 1000 Series Procedure Phased Array Angle Beam Calibration
Saudi Board of Radiology: Physics Refresher Course Kostas Chantziantoniou, MSc 2, DABR Head, Imaging Physics Section King Faisal Specialist Hospital &
IMAGE DATA ACQUISITION
Artifacts Ultrasound Physics George David, M.S.
Performance Issues in Doppler Ultrasound 1. 2 Fundamental Tradeoffs In pulsed modes (PW and color), maximum velocity without aliasing is In pulsed modes,
Tuesday Case of the Day - Physics Zheng Feng Lu, Ph.D., Stephen Thomas, M.D. Department of Radiology, University of Chicago, Chicago, IL Question: What.
Fundamental Ultrasound Principles Karen Potts Clinical Scientist Review date Jan 2010 Department of Medical Physics Kent & Canterbury.
 Ultrasound waves are longitudinal with high frequencies ( ≈ > 20,000 Hz, though medical Ultrasound is between 1 to 15 MHz.)  When an ultrasound reaches.
Ultrasound Physics Image Formation ‘97. Real-time Scanning Each pulse generates one line Except for multiple focal zones frame one frame consists of many.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
Chapter 10 Digital Signal and Image Processing
presented by: Reham Mahmoud AbD El-fattah ali
Ultrasound Physics Image Formation ‘97.
Lecture on Ultrasonography
Sound in medicine Lect.10.
What is Doppler Weather Radar
Ultrasound.
Ultrasound Physics Image Formation ‘97.
Ultrasound.
LESSON 2 IMAGING METHODS OF ACOUSTIC FIELDS
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
Doppler Radar Basics Pulsed radar
Spatially Varying Frequency Compounding of Ultrasound Images
MCQs (1) – Questions Ultrasound propagates through the medium as a transverse wave Ultrasound velocity is equal to the product of frequency and wavelength.
Medical Ultrasound: Fundamental Physics & Safety Implications
Review of Ultrasonic Imaging
Diagnostic Medical Sonography Program
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
PARAMETRIC SUB-BOTTOM PROFILER: A NEW APPROACH FOR AN OLD PROBLEM
ArtIfacts in usg Artifacts are part n parcel of any imagin modality .Us artifact can be avoidable and may be due to improper scanning technique. Recognition.
DOPPLER ARTIFACTS.
Chapter 12 Image Artifacts
The echo time (TE) The echo time (TE) refers to the time between the application of the radiofrequency excitation pulse and the peak of the signal induced.
Ultrasonic Imaging Using Contrast Agents
Presentation transcript:

Medical Ultrasound: Image Optimisation

Ultrasound image optimisation It is essential for those working with Ultrasound to have an applied knowledge of image optimisation. Controlling technical parameters can vastly enhance image quality. Misinterpretation of images is a significant risk in ultrasound imaging; with skill required to both maximise the diagnostic information and interpret images appropriately.

Equipment set-up Ultrasound equipment generally have anatomical area pre-sets. Applications specialists can assist in the customisation of these in clinical practice. Operators must select the most appropriate transducer and pre-set and manipulate optimisation controls continually to obtain the best quality images to inform and support examination findings, whilst adhering to the ALARA principle.

Transducers Modern Broadband transducers offer a selection of operating frequencies. Transducers vary in size as well as frequency selection. Anatomical size and location in addition to depth will help dictate transducer selection (i.e. small hockey stick high frequency transducer suitable for Metatarsophalangeal Joint scanning).

Key optimisation tools There are a number of operator controls available to optimise Ultrasound images. Fundamental controls include: Frequency Depth Sector width (line density) Gain Focus/focal zones Doppler

Frequency High frequencies should be selected to interrogate superficial Musculoskeletal structures. Deeper structures including the hip, shoulder and knee may require reduced frequency to obtain adequate penetration.

Depth Depth or field of view function Used to determine area of scan field Depth required dependant on structure of interest More depth-deeper structures Less depth- superficial structures Maximum depth dependant upon operating frequency/patient size or structure location/beam penetration.

Sector Width The sector width (sometimes called scan area) can be reduced or extended dependant on the required field of view. More scan lines (collecting data) in smaller area results in increased image quality Image quality and frame rate will increase with a smaller sector width It is wise to note that image land-marking is essential for retrospective review to assist in anatomical area recognition. A larger field of view may be required to include a neighbouring reference joint. A trackball is generally used to adjust sector width in & out.

Gain Overall Gain is usually a dial control- similar to turning the volume up on a stereo this amplifies returning echo’s across the whole image (Turn up (clockwise) brightens image and turn down darkens image). Time Gain Control (TGC) is generally a slider bar which allows the operator to select specific image depths for amplification. TGC is useful in amplifying deep returning echo’s which would otherwise appear brighter due to increased attenuation.

Focus The focus control is often a dial or toggle button with position and number indicated on screen. Produces a ‘thinner’ beam. Adjusting the focal zone to the area (or just behind the area) of interest will increase resolution therefore image quality. This is achieved by a series of time delays where the peripheral elements are fired first followed by the central elements resulting in the scan lines reaching a particular area of interest at the same time.

Focal zones Multiple focal zones can be applied e.g. interrogation of a tendon may warrant a superficial and deep focal zone corresponding to the tendon borders. Increasing the number of focal zones results in a reduction of frame rate as an additional pulse along the scan line is required. With multiple focal zones, the increased time taken for the additional transmit and return echo’s can cause the image to appear a bit disjointed with time lag.

Doppler - Power Power Doppler can identify slow flow and is particularly useful in identifying synovitis. It is imperative to adjust the pulse repetition frequency (PRF) and colour gain (similar to overall gain but amplifies Doppler signals within the colour box) to ensure that images are representative of anatomy and pathology. A high PRF can result in oversampling the tissue therefore unable to detect slow flow. A low PRF is adopted to allow low amplitude slow flow detection. Low PRF required for low flow.

Doppler - Colour A colour Doppler box can be sized and positioned over a standard B-mode image to assess blood flow. Colour Doppler assigns positive and negative Doppler shifts to a colour (typically red and blue). This informs direction of flow towards or away from the transducer. The Doppler shift frequency is angle dependant with very small or no signals produced at an angle of 90 degrees. Angles of insonation of between 30-60 degrees should be achieved for representative Doppler data (using a rocking or heel toe transducer manoeuvre may help). Small colour box = greater frame rate = more real time images.

Doppler -Spectral Spectral Doppler data can be achieved by selecting this option over a colour Doppler image. This applies a range gate to the colour Doppler image and based on the principle of detecting frequency shift can determine velocity of flow. This can be appreciated in velocity graphs with a velocity scale indicator. Seldom used in Musculoskeletal imaging field.

Image optimisation summary Highest frequency for penetration Small sector width Appropriate Gain/TGC Adequate depth for structure Appropriately positioned focus/no. of focal zones Small Doppler box Low Doppler PRF for low flow NB: Adequate image quality not always achievable