09:25 Operator dump fill #2178, integrated lumi 107/108/18 nb-1. Trip of RQ4.R6 (fire heaters discharged) just after the beam dump but the QPS gave no.
Advertisements

04:01 Injection kicker timing problems B2  Injection pre-pulse shifted, causing BETS to inhibit beam injection. 144 bunches on TDI.  Run without ROF.A81B2.
Thursday 20 th April 01:53 RCBV17.R7B2 tripped as happened few days ago: SIS intercepted. 05:54 Stable beams, 1380b, still RF problems B1, abort gap cleaning.
:30 meetingEBH 1  No beam during the morning:  4:15 – 9: V distributor: Recovery after electrical interruption  access for TI services.
Saturday Coordinators weekend: Mike Lamont, Eva Barbara Holzer
Wednesday :06 Dump fill 3533: interlock BPMS in IP6
Last 24 hours RQ4.L1 Lost going into collision Test ramp Storm
Wednesday 21 March 2012.
LHC Status Wed Morning 13-April R. Assmann, B. Holzer et al
Monday fill with 1092 bunches (6 h stable beams)
Saturday 30th June - Sunday: Rocky !
Thursday 09:30 VdM scan for CMS, standard ADT gain.
02/08/ :35: Lost access chain in point 2 (PX24 PAD)  Dump after ~14.5 hours ~100 nb-1.
LHC Morning Meeting - G. Arduini
Saturday 09:40 Stable beams #1369 (56 bunch scheme)
Tue :25 Beams dumped due to RF vacuum interlock
Saturday 12:00 Fill 1992 in stable beams.
Fri 29/7 – Sat 30/7 09:00 End of fill 1990, PC trip RCBXV3.R1 (likely SEU on QPS). Integrated Luminosity: 41 pb-1. Access for MKI2 main switch replacement.
Monday – recovery from MKI flashover
Thursday 17th May 01:11 Fill #2633 dump in squeeze arc circulator load channel Ad1B 03:16 Fill #2644 Stable beams, lumi 5.2e33 cm-2s-1 04:38 Dumped by.
Summary of Week 16 G. Arduini, J. Wenninger
Friday 31st August & night
Friday day 00:51 Fill #1862 Beams lost to inner triplet skew quad power converter fault. Delivered lumi 33 pb-1 Access required for repair RQSX3.L1 converter.
Friday Morning 3:44 – 15:04 stable beams Fill (dumped by operator)
04-05/08/2010 End of physics at ~11:00 after 18.5 hours ~120 nb-1.
Friday morning 10:30 Optics measurements and corrections.
Wire almost entirely through beam before BLM triggers dump
Not the most productive 24 hours on record
Friday Morning 7:30 injection for fill 2908
Friday AM Some oscillations of the cryo conditions in MSR8 perturbed the setup for injection. RF frequency interlock fixed – required a reset of RF controls.
Sunday
Programme for Saturday 10 July
Wednesday 10/5 Cryo recovery until 18:30
Tuesday Access for RF & QPS (others in the shadow) until ~18:00.
Sunday/Monday & :30 Stable beams. Fill #1851.
Summary of week 19 Machine Coordinators: G. Arduini, M. Lamont Main aim: Luminosity production.
Thursday Physics fill 1250 (with 13b) dumped at 10.30
Monday 24 October hours of 25ns MD
Monday 14:00 beam dump Access:
Rocky last 24 hours Losses Q6.R5 Orbit SIS TCDQ OK! Power converters
Saturday Nov Stop proton operation. Switch back to ions
Monday 8th December Morning used for RF work (IP z, injection), damper noise checks. Stable beams period with LHCb spectrometer OFF – lost beam after.
Thursday – Morning Energy matching at injection with H CODs
Fill 1743 Peak luminosity ~6.7 e32 Integratated lumi ~20 pb-1
Monday 6th 07:39 Dump fill #1854, RQ6.L2 tripped, followed by access
Monday morning 09:40 Dump fill 2838, integrated ~130 pb-1.
Thursday 22 September 2011.
Friday 14th September 03:15 Beta* at 1 km. Optics measurements, see yesterday. 07:00 Dump. 08:00 Refill with 3 nominal bunches for high beta. 11:15 Beams.
Monday Fill 1803 into stable beams at 9:30. Dump at 19:45.
Thu 04:00 Fill #2729 Stable Beams. Initial lumi 6.5e33 cm-2 s-1.
Sat 15/10 New record bunch population profiting of the scrubbing period on Friday. Nb~1.42x1011p/bunch  110 MJ at 3.5 TeV. Filling slowed down by ZS sparking.
Wednesday 16th May 03:05 beam dump, RF fault crowbar problem on module M1B2 06:09 Another crowbar at injection. Access for RF; problem Beam Imminent Warning.
Thursday 30th September De-bunching test
Thursday
Coordination: Eva Barbara Holzer, Mike Lamont
Wednesday h18: 228b fill lost just before start of ramp.
Monday 26th September 7:30 Beam dump, QSP on RQX.R1, lost cryo in ITR1, 91 pb-1. Cryo recovery, needed about 1.5 h. Setting of TI2 collimators to 5 sigma.
Thursday 20th July - morning
Another Immortal Fill….
Tuesday 24/5 Fill # :00 Stable beam fill # bunches
Monday 27th August & night
Wednesday 26 October 2011.
Wednesday morning / afternoon
Monday 14th May 00:03UFO at BLMQI.06R8.B2E10_MQML. Beam dump Re-steering required for TI2 03:28 STABLE BEAMS # e11 ppb, 4.11e33 cm-2s-1 13:36.
Saturday 28th 08:17 Fill #1812: Stable beams, peak luminosity ~1.1x1033 cm-2s-1 19:00 Go to adjust for RF-checks; Record fill lumi of 31.7 pb-1 for CMS.
Tuesday End of fill 1393 Movement of suspicious Roman pots OK
Tuesday
Wednesday 8th (I) 09:22 Fill #1855. Beams dumped by Alice dipole trip Stable beams for 10.5 hours; int. lumi 31 pb-1 After investigation EPC could not.
Tuesday
Presentation transcript:

Thursday 10th May - morning Fill 2605, 480 bunches into stable beams at around 9:15 no issues 10:40 Progress through experimentation Atlas separated to ~1.7 sigma Nothing seen CMS separated to … Nothing se…. eek… beam dump Large losses on two bunches of beam 2 Access during ramp-down RF, Atlas Regulation of Alice dipole power converter problem 11-5-12 LHC status

For 8B2 the problem is not understood. Investigations following the RF problems on cavities 1B1,3B1,8B2 last night For 1B1 and 3B1, the problem was a "weak" level of the 20 MHz clock used in the electronics. The level was just below the threshold used to generate an OK status. Although processing was not impaired, it prevented from switching the Line ON as the status is checked during the switch-On sequence and leads to abort if in fault. We have increased the RF level. That called for an access in UX45 around 12:00 For 8B2 the problem is not understood. We took advantage of the access to change one module but we do not think it was the problem. The symptom is more typical of a controls problem as it was solved by rebooting the front-end last night. It could however be caused by the communication with the RF modules in the VME crate. Being followed up off-line... Greg and Philippe 11-5-12 LHC status

~1.7 sigma ~1.5 sigma 5 microns 11-5-12 LHC status

Two bunches Issue with instabilities when beam are separated by 1-2 sigma, feed-forward of (effective) correction had lead to separation at this level going into collision… 11-5-12 LHC status

Two bunches 21041 and 21061 (or 2104 and 2106 in BI lingo) Head-on on in IP1 & 5 only Of 480 bunches 471 collide in 1&5, 461 of which in LHCb as well N-3, N-2 in train where N=72… LRE: {16,15} in IP 1, {11,10} in 5, {6,5} in 8, 11-5-12 LHC status

Thursday 10th May - afternoon 13:00 Access finished Injection somewhat dirty – steering required… Leading into a booster interlock problem and… PS quadrupole problem and… CMS ramping down to 3 T 16:40 Fill with 1380 17:30 Stable beams fill 2608 Initial luminosity ~3.9e33 cm-2s-1 Apologies to LHCb again… spiked ‘em CMS low to start … some concern Dumped after ~30 minutes by a UFO at the MKI2. 11-5-12 LHC status

Thursday evening 20:40 Back in stable beams Interesting B2 lifetime dip, lost some B2 at start of collision BP Initial luminosity ~3.7e33 , ~1.1e11 11-5-12 LHC status

Tail cleaning by working point movement(?) 11-5-12 LHC status

Friday early morning 2609 dumped by BLMs BLM at point 7 triggered the dump. It seems the beams became instable. 4 ADT modules went down around 20 minutes before Vacuum and ADT piquet in action The 2 gauges VGPB_277_5R4_R and VGPB_286_5R4_B (ADT interlock) went OFF at 01.01.18 as the value spiked up to 10E-3 11-5-12 LHC status

Just now 05:00 Re-injecting 06:30 Unable to load ramp to some RF FGCs Steering required again… 06:30 Unable to load ramp to some RF FGCs “Over the past 1.5 hours we have seen periods of several minutes in which about half the channels have lost communication, but only one at a time.  Andy has noted that the affected channels (Mask 0x4503) are spread across more than one equipment crate so the FGC is the likely common point.  I have reset the statistics counters but as of now, no new errors have been reported in the past 45 minutes.  When that happens it will help to narrow down what might be the cause. At the next access, I would recommend that the RF piquet swap the FGC for the hot spare.” Quentin King  This problem must be related to the sick cfv-ux45-acsc8b2t crate. As a function chain in a faraday cage makes a daisy chain through 4 cavity controllers, (8 crates: 4 feedback + 4 tuning) the consequence is that when one crate is malfunctioning there will be a general problem on the link. John Molendijk 11-5-12 LHC status

Program for the day 1380 @ 1.3e11 11-5-12 LHC status