Theory and Applications

Slides:



Advertisements
Similar presentations
Victor Sourjik ZMBH, University of Heidelberg
Advertisements

Some structures Dansyl chloride 1,5-I-AEDANS Fluorescein isothiocyante ANS Ethidium bromide 5-[2-[(2-iodoacetyl)amino]ethylamino] naphthalene-1-sulfonic.
Fundamental in Real Time PCR
Special Applications in Fluorescence Spectroscopy Miklós Nyitrai; 2007 March 14.
Why tethered-ligand technology? It is easy to bind targets to microarrays, but in order to detect interactions, the fluorescence of a spot must either.
Lecture 3 Kinetics of electronically excited states
Oligonucleotides – Primers and Probes by … as quality counts! Competence and Service in Molecular Biology metabion´s history.
Methods: Fluorescence Biochemistry 4000 Dr. Ute Kothe.
Oligonucleotides – Primers and Probes by … as quality counts! Competence and Service in Molecular Biology metabion´s history.
Lanthanide Complexes as Luminescent Labelsby Photonic Research Systems Ltd Web: Material(c) Photonic Research Systems Ltd
Non-radiative energy transfer from excited species to other molecules
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
Fluorescence Microscopy Chelsea Aitken Peter Aspinall.
Common types of spectroscopy
Fluorescence Spectroscopy 1Dr. Nikhat Siddiqi. Principles Interaction of photons with molecules results in promotion of valence electrons from ground.
FRET and Other Energy Transfers Patrick Bender. Presentation Overview Concepts of Fluorescence FRAP Fluorescence Quenching FRET Phosphorescence.
Are You FRETting? Find Out for Sure With FLIM Frequency Domain FLIM for Your Scope Intelligent Imaging Innovations.
FRET(Fluorescent Resonance Energy Transfer)
(D) Crosslinking Interacting proteins can be identified by crosslinking. A labeled crosslinker is added to protein X in vitro and the cell lysate is added.
Fluorescence Techniques
Lecture 7: Fluorescence: Polarization and FRET Bioc 5085 March 31, 2014.
CSB Techniques Workshop May 2008 Fluorescence Methods Jeremy Moore.
Real-Time Quantitative PCR Basis
Fluorescence Absorption of light occurs within ~ seconds, leaving a molecule in an excited state What happens next? –If no photon is re-emitted,
Figure 1: Basic Principle Of PCR * Poor precision * Low sensitivity * Short dynamic range < 2 logs * Low resolution * Non-automated * Size-based discrimination.
Chapter 15 Molecular Luminescence Spectrometry Three types of Luminescence methods are: (i) molecular fluorescence (ii) phosphorescence (iii) chemiluminescence.
Powerpoint Templates Page 1 Powerpoint Templates Spectroscopic Microscopy.
Scanning excitation and emission spectra I Wavelength (nm) )Scan excitation with emission set at 380 nm -λ ex,max = 280 nm 2) Scan emission.
Use of Ethidium Bromide in gel electrophoresis  Ethidium bromide is an intercalating agent commonly used as a fluorescent tag (nucleic acid stain) in.
23.7 Kinetics of photochemical reactions
Förster Resonance Energy Transfer (Chemistry/Biology Interface) Michelle, Pauline, Brad, Thane, Hill, Ming Lee, Huiwang Facilitator: Nancy.
Today’s Announcements 1.Next Tuesday: Diffusion (Why moving in a cell is like swimming in concrete.) 2. Homework assigned today Last graded Homework:
Förster Resonance Energy Transfer (FRET)
R EAL TIME P CR 1. L IMITATIONS OF E ND -P OINT PCR Poor Precision Low sensitivity Low resolution Non - Automated Size-based discrimination only Results.
IPC Friedrich-Schiller-Universität Jena 1 Radiationless excitation energy transfer requires interaction between donor and acceptor  Emission spectrum.
Weight Encoding Methods in DNA Based Perceptron 임희웅.
Detect and identify Bioanalytic Bioluminescence Resonance Energy Transfer.
HTRF basics.
Assay development for screening on purified or partially purified targets with fluorescent and bioluminescent readouts.
Measurement Methods in Systems Biology
Ultrafast Spectroscopy
SNPs in forensic genetics: a review on SNP typing methodologies
Application of Rapid-Cycle Real-Time Polymerase Chain Reaction for the Detection of Microbial Pathogens: The Mayo-Roche Rapid Anthrax Test  James R. Uhl,
Midterm 2 (53 students wrote the exam)
Measuring Fluorescence Resonance Energy Transfer in vivo
Principles of Real-Time Quantitative PCR Techniques
Drug/Target Validation
Fluorescence Polarization Immunoassay FPIA
Nucleic acid-based methods (I)
Israel maritime college
RT-PCR ANALYSIS NOHA L. IBRAHIM.
Minimal Residual Disease (MRD) Detection Technologies
Biophysical Tools '04 - Fluorescence
AMPLIFYING AND ANALYZING DNA.
26.11 Kinetics of photochemical reactions
Reading Fluorescence with a Microplate Reader BioTek Instruments, Inc.
Application of Rapid-Cycle Real-Time Polymerase Chain Reaction for the Detection of Microbial Pathogens: The Mayo-Roche Rapid Anthrax Test  James R. Uhl,
Rapid detection of resistance in Mycobacterium tuberculosis: a review discussing molecular approaches  D. García de Viedma  Clinical Microbiology and.
Nucleic acid-based methods (I)
Today’s take-home lessons: FRET (i. e
Fluorescence Applications in Molecular Neurobiology
Today’s take-home lessons: FRET (i. e
A Fluorescence Resonance Energy Transfer Sensor Based on Maltose Binding Protein Xianhui Li
Förster Resonance Energy Transfer (FRET)
Spectrophotometric Methods for Determination of Proteins Concentration
Fluorescence: nucleic acid quantitation (DNA, oligonucleotides, RNA…)
Zihua Zeng, Ching-Hsuan Tung, Youli Zu 
The Effect of Dye-Dye Interactions on the Spatial Resolution of Single-Molecule FRET Measurements in Nucleic Acids  Nicolas Di Fiori, Amit Meller  Biophysical.
RealTime-PCR.
Real-Time PCR.
Presentation transcript:

Theory and Applications FRET, TR-FRET Theory and Applications

How to run on a microplate reader Advantages and limitations of FRET FRET: contents Introduction Theory Applications How to run on a microplate reader Advantages and limitations of FRET

FRET: Introduction FRET = Fluorescence Resonance Energy Transfer FRET is used in research laboratories typically to study molecular interactions. Like other fluorescent techniques it is used a lot in imaging applications (microscopy) Time-Resolved FRET (TR-FRET) is mostly used for screening applications in microplates (more robust than FRET, less interferences).

FRET: Theory Cy3 Cy5 Fluorescent molecules: Excitation spectrum 500 450 550 600 650 700 750 nm Fluorescent molecules: Excitation spectrum Emission spectrum Cy3: Ex max at 550 nm Em max at 565 nm Cy5: Ex max at 652 nm Em max at 667 nm Cy3 Cy5 550 nm 565 nm 652 nm 667 nm

FRET: Theory If you mix Cy3 and Cy5 in a well, they will behave as two independent dyes. Cy3 ex results in Cy3 em However, in very close proximity, FRET occurs, and Cy3 excitation results in Cy5 emission Cy3 is called the Donor Cy5 is called the Acceptor The Cy3 – Cy5 couple is called a FRET pair 550 nm 565 nm 652 nm 667 nm 550 nm 667 nm FRET

FRET: Theory FRET is the transfer of energy between a Donor molecule which is in a excited state and an Acceptor molecule This transfer happens without emission of a photon from the Donor After the transfer of energy, the excited Acceptor returns to its ground state by releasing energy as a photon 550 nm 667 nm FRET DONOR ACCEPTOR

FRET: Theory Cy3 Cy5 FRET will only occur if: 500 450 550 600 650 700 750 nm Cy3 Cy5 FRET will only occur if: The emission spectrum of the Donor (e.g. Cy3) overlaps with the excitation spectrum of the Acceptor (e.g. Cy5). Donor and Acceptor molecules are in close proximity (typically 10-100 A). 550 nm 667 nm FRET 10–100 Å (1-10 nm)

FRET: Theory FRET is extremely sensitive to distance 550 nm 667 nm FRET 50 A E = 50 % FRET is extremely sensitive to distance The efficiency (E) of FRET is described by the equation: E = Ro6/(Ro6 + r6) Where Ro is the “Förster” radius, at which E = 50 % efficiency, and r is the actual distance between the Donor and the Acceptor. For the Cy3-Cy5 FRET pair, Ro is about 50 A (5 nm) 550 nm 667 nm FRET 100 A E = 1.5 % 550 nm 667 nm FRET 25 A E = 98 %

FRET: Theory The Förster radius is typically in the 1 to 10 nm range for FRET pairs 1 to 10 nm is also the typical size range for proteins. For this reason, FRET is extremely useful to study interactions between molecules, with a spatial resolution well beyond what optical microscopy can do. 5 nm 550 nm 667 nm FRET 5 nm

FRET: Theory If you label a potential ligand and a receptor, FRET allows you to detect if they bind or not. No binding would result in high Donor fluorescence and no Acceptor fluorescence. Binding would result in reduced Donor fluorescence and measurable Acceptor fluorescence. 550 nm 565 nm 667 nm

FRET: Theory FRET can be measured as a reduction of Donor emission; an increase of Acceptor emission; or a combination of both, usually expressed as a ratio. 550 nm 565 nm 667 nm

How to run on a microplate reader Advantages and limitations of FRET FRET: contents Introduction Theory Applications How to run on a microplate reader Advantages and limitations of FRET

FRET: applications Example 1: Receptor – ligand binding Example 2: Detection of nucleic acid hybridization Example 3: Real-time detection of PCR amplification Example 4: Ion channel assay Example 5: Protease assay

FRET: applications, receptor-ligand binding The target receptor is labeled with the Donor, a positive control ligand is labeled with the Acceptor. In the absence of a competing drug candidate, FRET occurs. A potential competitor ligand is added If the competitor displaces the original ligand, FRET disappears

FRET: applications, detection of nucleic acid hybridization In this example, the Acceptor is a quencher rather than a fluorescent molecule. It absorbs light but does not fluoresce. A FRET probe with a known sequence is mixed with the target DNA. If it hybridizes with a complementary sequence, the FRET pair is separated and the Donor fluoresces.

FRET: applications, detection of real-time PCR amplification Primer Target DNA TaqMan In addition to the standard PCR reagents, a FRET-based TaqMan® probe is used Both the primers and the TaqMan probe hybridize with the target DNA During the Taq polymerase extension step, the probe is destroyed, FRET disappears FRET

FRET: applications, VSP ion channel assay (Invitrogen) + + + _ _ _ K+ Extracellular Intracellular - + + + _ _ _ FRET CC2-DMPE (Coumarin-Phospholipid) DiSBAC2(3) (hydrophobic oxonol) Copyright ©2005 Invitrogen Corporation.

FRET: applications, protease assay A peptide that can be degraded by the HIV protease is selected. It is labeled with a FRET pair (Fluorescent Donor, Quenching Acceptor) Active HIV protease degrades the substrate and separates the FRET pair. Fluorescence is measured.

How to run on a microplate reader Advantages and limitations of FRET FRET: contents Introduction Theory Applications How to run on a microplate reader Advantages and limitations of FRET

FRET: how to run on a microplate reader The question is: is there FRET or not in a given sample. Absence of FRET means that if you excite the Donor, you should mostly see Donor emission. Presence of FRET means that if you excite the Donor, you should see a mix of Donor emission and Acceptor emission. 550 nm 565 nm 550 nm 667 nm FRET

FRET: how to run on a microplate reader So for a FRET measurements: Excite at the Donor’s excitation wavelength Typically measure both emission channels (Donor and Acceptor). If the Acceptor is a quencher, you just monitor the Donor’s fluorescence. 550 nm 565 nm 550 nm 667 nm FRET

FRET: how to run on a microplate reader Most often FRET assays are end-point assays. The signal is stable over time and the Donor and Acceptor fluorescence can be measured sequentially. In the example above, the plate is measured first with an excitation at 400/30 nm and emission at 460/40 nm (Donor channel), then measured with a 400/30 nm – 590/35 nm filter pair (Acceptor channel)

FRET: how to run on a microplate reader Some FRET assays have fast signal kinetics (e.g. VSP ion channel assay). In these cases, an automated reagent injector is required, and the two emission channels are measured simultaneously and kinetically for each single well.

How to run on a microplate reader Advantages and limitations of FRET FRET: contents Introduction Theory Applications How to run on a microplate reader Advantages and limitations of FRET

FRET: advantages Cy3 Cy5 Cy3 Cy5 Study binding events at the molecular level Can be used for a wide variety of assays Homogeneous assays. No need to remove unbound reagents. Can be ratiometric, more robust: 500 450 550 600 650 700 750 nm Cy3 Cy5 EX EM1 EM2 750 nm 500 450 550 600 650 700 Cy3 Cy5 EX EM1 EM2 Cy5/Cy3=0.5 Cy5/Cy3=0.5

FRET: limitations Background due to non-specific excitation of Acceptor (1) and residual emission of Donor in the Acceptor’s emission range (2) (see below). This is a major limitation of FRET (limited assay window and sensitivity). Complex labeling, relatively complex assay development 500 450 550 600 650 700 750 nm Cy3 Cy5 EX EM 550 nm 565 nm Donor Acceptor 667 nm (1) 667 nm (2)

Benefits compared to FRET Limitations Applications TR-FRET: contents Theory Benefits compared to FRET Limitations Applications How to run on a microplate reader

TR-FRET: Time Resolved Compounds Lanthanide (e.g. Europium) chelates or cryptates are fluorescent compounds. Their lifetime after excitation is in the µs to ms range instead of ns for standard fluorescent dyes. If you excite them with a pulsed light source (e.g. Xenon Flash), wait (e.g. 20 µs) and read, all short-lived background fluorescence is gone at the time of the measurement, and the excitation light is off. H 3 C CH N Eu 3+ Time (µs) I n t e s i y 2 25-125 µs Reading

TR-FRET: Time Resolved Compounds Time-Resolved compounds provide extremely low background compared to conventional fluorescent dyes. They can be used as Donors in FRET assays. These assays are called TR-FRET or TRET assays. HTRF® (Homogeneous Time Resolved Fluorescence) is a trademarked assay platform (Cisbio) based on TR-FRET. H 3 C CH N Eu 3+ Time (µs) I n t e s i y 2 25-125 µs Reading

TR-FRET: theory 340 nm 620 nm 633 nm 665 nm TR-compound Donor Standard dye Acceptor (ms) (ns) When excited, the TR Donor emits light over a few milliseconds. When excited directly, the Acceptor emits light over a few nanoseconds. When FRET occurs, the energy transfer occurs over a few milliseconds, thus the emission of the Acceptor occurs in the same time-frame. 340 nm 665 nm FRET TR-compound Donor Standard dye Acceptor (ms)

Benefits compared to FRET Limitations Applications TR-FRET: contents Theory Benefits compared to FRET Limitations Applications How to run on a microplate reader

TR-FRET: benefits compared to FRET Recall crosstalk problem with FRET: Some direct excitation of the Acceptor at Donor excitation wavelength Some Donor emission appears in Acceptor emission channel TR-FRET eliminates problem 1, because at the time of measurement (delayed after excitation), the unwanted emission of the free Acceptor (in the ns time scale after excitation) is gone. TR-FRET reduces assay background compared to FRET. 550 nm 565 nm 550 nm 667 nm (1) 667 nm Crosstalk issue in standard FRET (2) Donor Acceptor

TR-FRET: benefits compared to FRET In addition to non-specific Acceptor fluorescence, TR-FRET eliminates all short lived interference (fluorescence from other molecules). Time (µs) I n t e s i y 2 25-125 µs Reading Short lived fluorescence (ns time scale) Measurement window

TR-FRET: benefits compared to FRET Ro (distance between Donor and Acceptor giving a 50% FRET efficiency) can be as high as 9 or 10 nm, compared to around 5 nm for standard FRET. Allows working with large proteins Makes assays more robust (it is easier to get a signal) Makes assay development easier (label position on molecule is less critical). TR-FRET is more flexible in Acceptor concentration (because no crosstalk signal from Acceptor) TR-FRET is more forgiving for incomplete labeling In general, TR-FRET provides easier assay development and more robust assays.

TR-FRET: limitations TR fluorescent dyes are not very bright (low quantum yield). They are not efficient Donors compared to standard FRET Donors. This limits the benefit of having a reduced background level. Background due to residual emission of Donor in the Acceptor’s emission range. Complex labeling, relatively complex assay development Lanthanide labeling can be expensive.

Benefits compared to FRET Limitations Applications TR-FRET: contents Theory Benefits compared to FRET Limitations Applications How to run on a microplate reader

TR-FRET: applications Because of cost of reagents and cost of instrumentation (requires high-energy pulsed light source), TR-FRET is mostly used for drug screening assays. Reagents are sometimes available as kits (cAMP assay kits, kinase assays kits) but are mostly available as “tool boxes” for assay development laboratories. HTS preferred technologies:

TR-FRET: applications Cisbio: HTRF® assay platform Perkin Elmer: LanceTM assay platform Invitrogen: LanthaScreenTM assay platform

TR-FRET: HTRF® Europium cryptate-based assay. Receptor Ligand Copyright ©Cisbio International Europium cryptate-based assay. Europium cryptate is the Donor, the Acceptor is XL665 (modified allophycocyanin, standard short-lived fluorescent label).

TR-FRET: HTRF®, example of cAMP kit 620 nm TR-FRET Copyright ©Cisbio International A labeled anti-cAMP antibody and labeled cAMP are mixed. TR-FRET occurs. The TR-FRET complex is added to the sample. If cAMP is present in the sample it displaces the labeled cAMP. Presence of cAMP is detected by a decrease in the TR-FRET ratio.

TR-FRET: LanthaScreenTM Copyright ©2005 Invitrogen Corporation Terbium chelate-based assay. Europium and Terbium are the two commonly used Lanthanides in TR assays.

TR-FRET: LanthaScreenTM, example of kinase assay Copyright ©2005 Invitrogen Corporation Fluorescein-labeled kinase substrate peptide is incubated with kinase and ATP A Tb-labeled antibody is then added Phosphorylation (kinase activity) is detected by an increase in the TR-FRET ratio

Benefits compared to FRET Limitations Applications TR-FRET: contents Theory Benefits compared to FRET Limitations Applications How to run on a microplate reader

TR-FRET: How to run on a microplate reader TR-FRET assay are almost always end-point assays. Exact same principle as standard FRET assays. In the example above, the plate is measured first with an excitation at 340/30 nm and emission at 620/20 nm (Donor channel), then measured with a 340/30 nm – 665/20 nm filter pair (Acceptor channel). The difference is that you need a pulsed light source (Xenon Flash Lamp, Pulsed Laser…). Standard FRET can be measured with a continuous or pulsed light source.

FRET, TR-FRET: Conclusion FRET used a lot in microscopy, In microplate format: Used in research labs on a regular basis TR-FRET very common in screening applications Like any other assay platform, has advantages that make it extremely useful for some applications, and limitations that make it less attractive in other areas.

TR-FRET: Conclusion For more details on FRET and TR-FRET, see: http://www.biotek.com/products/tech_res_detail.php?id=159 www.htrf-assays.com (Cisbio international)