Temperature Program Features & Benefits CPT1000 & othersB6000 Reference thermometers CTD9300 & others Dry well calibrators Features & Benefits CTM9100 Multi function calibrator CTB9430 & others Calibration baths
Temperature dry well calibrators Calibration thermocouple General Minimum Immersion depth 70 mm Consider stability time of the device under test If reference then same immersion depth as DUT CTD9300 CTD9100 CTD ZERO Calibration resistance thermometer General handling
Applications dry well calibrators Temperature Applications dry well calibrators Short description: On-site calibration of resistance thermometers or thermocouples with or without external reference thermometer depending on the depth of immersion Short description: Using in the process portable Calibration equipment Calibration of short stem thermometers Using an external reference With or without reference
干井式温度校验仪 Dry well calibrator Temperature 干井式温度校验仪 Dry well calibrator CTD9300-165 CTD9300-650 Temperature range -35⁰C to +165⁰C by Peltier elements Temperature range +40⁰C to 650⁰C by resistance heating Accuracy down to ± 0.1K, resolution 0.01K Immersion depth 150mm Heating up time 12min from 20 ⁰C to 165 ⁰C Temperature ramp function Automated calibration Integratable measuring instrument for RTD, TC, mA & thermostats Dry block temperature is user adjustable by a 6 points calibration Data sheet CT41.38
干井式温度校验仪 Dry well calibrator Temperature 干井式温度校验仪 Dry well calibrator CTD9100-COOL CTD9100-165 CTD9100-450 CTD9100-650 Temperature range -55⁰C to +650⁰C Accuracy from 0.15 to 0.8K Stability: 0.01…0.05K Immersion depth: 150mm Tell me more…
干井式温度校验仪 Dry well calibrator Temperature 干井式温度校验仪 Dry well calibrator CTD9100-375 CTD9100-ZERO CTD9100-1000 Measuring range: Tamb to 375⁰C Accuracy 0.2K Stability 0.05K Immersion depth: 100mm
Temperature multifunctional calibrator portfolio Model CTM9100-150 Range -35 …+165°C Micro- calibration bath -20 … +150°C all other applications -30 …+330°F Micro- calibration bath -4 … +300°F all other applications Accuracy +/- 0.1 K Micro-calibration bath +/- 0.3 K Drywell calibrator +/- 1 K Infrared Black Body source +/- 1 K Surface temperature calibrator Stability +/- 0.05 K Micro-calibration bath +/- 0.05 K Drywell calibrator +/- 0.2 K Infrared Black Body source +/- 0.2 K Surface temperature calibrator Immersion depth 150 mm / 6” Features Small dimensions Simple operation General Pelitier Inserts liquids Store up to four set points Select the saved temperature with U (long) Change the temperature value with P (short) Adjustment wheel for the velocity of the stirrer
Operating Manual: CTM9100 CTM9100-150 Operating elements: Store up to four set points Select the saved temperature with U (long) Change the temperature value with P (short) Adjustment wheel for the velocity of the stirrer Recommendation for an optimal calibration: use the correct operating mode incl. Int./ext. Reference Minimum immersion depth 70 mm (dB) Adjust the velocity of the stirrer acc. to the liquid (li) Stabilization time of the device under test
Temperature multifunctional calibrator portfolio Application as Dry well Application as Black Body Application as Micro-calibration Bath Application as Surface Calibrator CTM9100-150 DB ir li su DB = Dry Block LI = Liquid IR = Infrared SU = Surface What modes How to use use the correct operating mode incl. Int./ext. Reference Minimum immersion depth 70 mm (dB) Adjust the velocity of the stirrer acc. to the liquid (li) Stabilization time of the device under test