Temperature Program Features & Benefits CPT1000 & othersB6000

Slides:



Advertisements
Similar presentations
Welcome Herzlich Willkommen Bienvenue JUMO eTRON T data sheet
Advertisements

1 Calibration of Thermometry Instruments Nihal Gunasekara Sri Lanka Bangladesh BEST Programme.
01/14/2001Temperature and Humidity1 Temperature and Humidity Paul M. Fransioli, CCM AMS Short Course on Introduction to Measurements and Observation Techniques.
THE FLOW OF FOOD: AN INTRODUCTION
Temperature Handheld WIKA Calibration Line Pressure Hand-Helds Signal Calibrator Hand-Helds Temperature Hand-Helds.
Selection of measuring instruments
Measurements in Fluid Mechanics 058:180 (ME:5180) Time & Location: 2:30P - 3:20P MWF 3315 SC Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor: Lichuan.
Measurements in Fluid Mechanics 058:180:001 (ME:5180:0001) Time & Location: 2:30P - 3:20P MWF 218 MLH Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor:
The Flow of Food Objectives: How to prevent cross-contamination
The Flow of Food To keep food safe throughout the flow of food:
Module 3 Eng. Asma Abu Baker. Introduction One of the most important uses of instruments or measuring devices is in the field of process control. If you.
Water Quality, Temperature and Gloss Measurement Instrumentation.
Thermometer Calibration & Use Shannon Rohall Stevie Arroyo.
1 CPB 5000 Pressure Balance -Product overview-. 2 CPB product line CPB 5000 „Standard“ CPB 3800 „Compact Line“ CPB 5000 „Premium“ HighEnd / Laboratory.
CHAPTER 9 Control System Instrumentation
CPT2000 Platinum Resistance CED7000 & others Signal calibrators CPT9000 Thermocouple CPT1000 Platinum Resistance Features & Benefits Reference Thermometers.
Measuring Temperature
The Flow of Food Objectives: How to prevent cross-contamination
MODEL : EDF-102 SERIES 1. APPLICATION The EDF-102 thermostat is designed to provide temperature control of heating or cooling systems in villas, hotels.
Temperature Measure of internal energy of substance Four common scales Celsius (C) Kelvin (k) Fahrenheit (F) Rankine (R)
Mark Maizonnasse, Creaform IMPROVEMENT OF AIRCRAFT MECHANICAL DAMAGE INSPECTION WITH ADVANCED 3D IMAGING TECHNOLOGIES.
Shipboard Technical Support (STS) Calibration Facility
Instrument Calibration.  As previously discussed the principle of measurement is comparing a component against a known standard therefore any equipment.
Temperature describes how hot or cold an object is. Chapter 4
Experiment 1. Temperature and Pressure Calibration Temperature measurement tips are illustrated here for one of the setups at Station 4. The reference.
CHAPTER 9 Control System Instrumentation
Objectives: How to prevent cross-contamination How to prevent time-temperature abuse How to use the correct kinds of thermometers to take temperatures.
High temperature measuring thermometer by Roman Lukomskyi.
Chapter 4: The Flow of Food
In what temperatures do pathogens grow rapidly?
TVS Temperature Verification System (For BMS Distributors Only)
Temperature Sensors.
Temperature Sensors.
Author: Nurul Azyyati Sabri
Product Presentation T12 Thermometer.
The Flow of Food To keep food safe throughout the flow of food:
Measurements & Instrumentation – Module 3
The Flow of Food To keep food safe throughout the flow of food:
INTRODUCTION TO Immersion Ultrasonics
This is Chapter 5 in your book
The Flow of Food: an Introduction
The Flow of Food To keep food safe throughout the flow of food:
Thermocouples and rtd Prepared By: Ansari Najma A. ( )
Surface Temperature: Everest
Explore the future HORIBA GROUP
Bell Ringer What is the temperature danger zone?
Designed to Make Your Work Easier
AT-2040 Vibration Sensor test Set.
Instruments for measuring physical quantities of the environment Standard EN ISO 7726 Accepted in 2001 Marianna Luoma.
Evaluation of Infra-Red Thermometers
The Flow of Food To keep food safe throughout the flow of food:
Overview of Temperature Measurement ME 115
TEMP MEASURING INSTRUMENTS
The Flow of Food To keep food safe throughout the flow of food:
The Flow of Food To keep food safe throughout the flow of food:
The Flow of Food To keep food safe throughout the flow of food:
The Flow of Food: An Introduction
The Flow of Food To keep food safe throughout the flow of food:
Prepared by Dr. Mohamed Ahmed Awad
TASK 3: DIGITAL THERMOMETER
Portable Temperature Measurement Instruments by Testo Testo is a world market leader in the field of portable and stationary measurement solutions
The Flow of Food To keep food safe throughout the flow of food:
Instrumentation and Control: ME- 441 Department of Mechanical Engineering UMT 1.
The Flow of Food Objectives: How to prevent cross-contamination
The Flow of Food To keep food safe throughout the flow of food:
The Flow of Food Objectives: How to prevent cross-contamination
724 Temperature Calibrator
The Flow of Food Objectives: How to prevent cross-contamination
Total Solution for Flue Gas Analyzer Series
Performance Specifications
Presentation transcript:

Temperature Program Features & Benefits CPT1000 & othersB6000 Reference thermometers CTD9300 & others Dry well calibrators Features & Benefits CTM9100 Multi function calibrator CTB9430 & others Calibration baths

Temperature dry well calibrators Calibration thermocouple General Minimum Immersion depth 70 mm Consider stability time of the device under test If reference then same immersion depth as DUT CTD9300 CTD9100 CTD ZERO Calibration resistance thermometer General handling

Applications dry well calibrators Temperature Applications dry well calibrators Short description: On-site calibration of resistance thermometers or thermocouples with or without external reference thermometer depending on the depth of immersion Short description: Using in the process  portable Calibration equipment Calibration of short stem thermometers  Using an external reference With or without reference

干井式温度校验仪 Dry well calibrator Temperature 干井式温度校验仪 Dry well calibrator CTD9300-165 CTD9300-650 Temperature range -35⁰C to +165⁰C by Peltier elements Temperature range +40⁰C to 650⁰C by resistance heating Accuracy down to ± 0.1K, resolution 0.01K Immersion depth 150mm Heating up time 12min from 20 ⁰C to 165 ⁰C Temperature ramp function Automated calibration Integratable measuring instrument for RTD, TC, mA & thermostats Dry block temperature is user adjustable by a 6 points calibration Data sheet CT41.38

干井式温度校验仪 Dry well calibrator Temperature 干井式温度校验仪 Dry well calibrator CTD9100-COOL CTD9100-165 CTD9100-450 CTD9100-650 Temperature range -55⁰C to +650⁰C Accuracy from 0.15 to 0.8K Stability: 0.01…0.05K Immersion depth: 150mm Tell me more…

干井式温度校验仪 Dry well calibrator Temperature 干井式温度校验仪 Dry well calibrator CTD9100-375 CTD9100-ZERO CTD9100-1000 Measuring range: Tamb to 375⁰C Accuracy 0.2K Stability 0.05K Immersion depth: 100mm

Temperature multifunctional calibrator portfolio Model CTM9100-150 Range -35 …+165°C Micro- calibration bath -20 … +150°C all other applications -30 …+330°F Micro- calibration bath -4 … +300°F all other applications Accuracy +/- 0.1 K Micro-calibration bath +/- 0.3 K Drywell calibrator +/- 1 K Infrared Black Body source +/- 1 K Surface temperature calibrator Stability +/- 0.05 K Micro-calibration bath +/- 0.05 K Drywell calibrator +/- 0.2 K Infrared Black Body source +/- 0.2 K Surface temperature calibrator Immersion depth 150 mm / 6” Features Small dimensions Simple operation General Pelitier Inserts liquids Store up to four set points Select the saved temperature with U (long) Change the temperature value with P (short) Adjustment wheel for the velocity of the stirrer

Operating Manual: CTM9100 CTM9100-150 Operating elements: Store up to four set points Select the saved temperature with U (long) Change the temperature value with P (short) Adjustment wheel for the velocity of the stirrer Recommendation for an optimal calibration: use the correct operating mode incl. Int./ext. Reference Minimum immersion depth 70 mm (dB) Adjust the velocity of the stirrer acc. to the liquid (li) Stabilization time of the device under test

Temperature multifunctional calibrator portfolio Application as Dry well Application as Black Body Application as Micro-calibration Bath Application as Surface Calibrator CTM9100-150 DB ir li su DB = Dry Block LI = Liquid IR = Infrared SU = Surface What modes How to use use the correct operating mode incl. Int./ext. Reference Minimum immersion depth 70 mm (dB) Adjust the velocity of the stirrer acc. to the liquid (li) Stabilization time of the device under test

Key customers