GENTLEsilence LUX 8000 B ... fascinating silence

Slides:



Advertisements
Similar presentations
What you need to know about ASPIJECT ® & local dental anaesthesia Quality you can Feel! ASPIJECT.
Advertisements

JAQUET Products for Hydraulic Applications.
Large Taper Files. Engine-driven files Hand-Using Large Taper Files.
Pipe Cutting System The evolution of Patented products Designed in Finland pipe cutting.
COPYRIGHT SILCA SpA 2005 Silca is a member of the Kaba Group.
Acoustics in Twenty Words or Less. What is Acoustics? The Science of Sound!
Page 1 of 28 Modular Instruments for Suction and Irrigation Versatile and Precise Presentation Suction- and Irrigation Systems presents:
Flow Produced Noise & Fluid Mechanical Treatment Flow Produced Noise & Fluid Mechanical Treatment Prepared By: Eng. Ashraf Al-Shalalfeh Mechanical Engineering.
ROTARY CUTTING INSTRUMENTS  Dr.linda Maher. ROTARY CUTTING INSTRUMENTS  A group of instruments operated with a power source and used for cutting, finishing.
Restorative Dental Instruments
Our PREMIER INSTRUMENTS line of surgical tools are manufactured at ISO 9001 certified facilities using only the finest quality German surgical Stainless.
Chapter 16 – Waves and Sound
Announces the New EOS Pump Range EOS 15-C25 EOS 30-C25
Optimizing your handpiece life! By The Dentist’s Choice.
Sound Sound - A wave which is created by vibrating objects and transmitted through a medium from one location to another. Auditory – having to do with.
COPYRIGHT SILCA SpA 2007 RekordSilca S.p.A.. COPYRIGHT SILCA SpA 2007 RekordSilca S.p.A. REKORD Rekord is the new Silca key cutting machine for cylinder.
Metso - Slurry Pumping.
Acoustical Properties of Materials Chapter 8. Mehta, Scarborough, and Armpriest : Building Construction: Principles, Materials, and Systems © 2008 Pearson.
Environmental Technology Noise Assessment & Abatement Module 7.0.
Waves. Examples –Water waves –Sound waves –Light waves –Radio waves –microwaves.
Week 2 Sound Physics, Ranges of Hearing Frequency, Wavelength, Period, Velocity Audio Engineering & Sound Production Unit code: AUD202 AUDIO & ACOUSTICS.
Fundamentals of Audio Production. Chapter 1 1 Fundamentals of Audio Production Chapter One: The Nature of Sound.
By Rhett Price. Speed of sound depends on density Correlation between speed and density Not as fast as light speed Also affected by pressure and temperature.
Sound – Part 2 Year 7 Science.
ROTARY CUTTING INSTRUMENTS
Sound Waves Vibration of a tuning fork
UC Davis Safety Services Monthly Safety Spotlight February 2010: Workplace Ergonomics/Shop & Field Safety Discussion Topics Be Smart About Tool Use Workspace.
Power Generation Turbines
UNIT EIGHT: Waves  Chapter 24 Waves and Sound  Chapter 25 Light and Optics.
 What do we know about outer space?  What does the bell jar experiment tell us about sound?  Correct! Sound needs a medium to travel though....When.
Main Parts of a Drilling Machine
Drilling machine. Introduction Drilling is a metal cutting process carried out by a rotating cutting tool to make circular holes in solid materials. Tool.
STRILIZATION AND DISINFECTION IN A DENTAL CLINIC
Shock Absorber PowerStop EmergencyStop
ARCHITECTURAL ACOUSTICS
Sound Intensity Level – Learning Outcomes
Thermal Spray Coatings Asst.Prof.Dr. Ali Sabea Hammood Materials Engineering Department Materials Engineering Department Faculty of Engineering Faculty.
Ullrich, DESY Dubna GDE XFEL The European X-Ray Laser Project X-Ray Free-Electron Laser 1 Water cooling XFEL Desingn of the XFEL water cooling.
Waves Sound & Light.
Sound Waves Vibration of a tuning fork.
Sound.
Sound.
Assist Gas for Laser Cutting
The New C55* CPVSd 10-20hp People. Passion. Performance.
REKORD Rekord is the new Silca key cutting machine for cylinder keys for doors, vehicles and cruciform keys.
DISC FINISHING MACHINES
Optimum Pump Performance for Process Applications
SIGENTICS HV Series S-modyn
Prepared for Cole Parmer
What is Magnetite? Magnetite storm window insulating panels are a unique interior mounted acrylic window panel that attaches and seals magnetically around.
Sound Intensity Level – Learning Outcomes
HEARING AND THE OTHER SENSES
HIGH PERFORMANCE PRESSURE SYSTEMS.
COMFAIR HD WALL WATER FAN COIL UNIT
MDC Mungo Diamond Cut MDG Mungo Diamond Grind
Stop Valve – Types, Application and Working
SONICflex microinvasive
Application Operation principle Advantages Highlights Comparison
removal of approximal enamel
Sound Learning Objectives:
KaVo SUPERtorque ingenious angle combination SUPERtorque 660
KaVo GENTLEmini LUX Turbine 5000 B - the ideal completion
The evolution of pipe cutting Patented products Designed in Finland Pipe Cutting System.
Pistons, Rings, and Connecting Rods
VEIT Hand Ironing Technology
The introduction to the KaVo MULTIflex-world
VEIT Hand Ironing Technology
Sonoabrasive instruments for caries excavation
BMW F 850 GS Engine: Water-cooled 4-stroke in-line two-cylinder engine, four valves per cylinder, two overhead camshafts, dry sump lubrication  Capacity:
SCITEQ End closure series
Presentation transcript:

GENTLEsilence LUX 8000 B ... fascinating silence 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 fascinating silence GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 fascinating silence Noise creates stress and under long term impact it damages the human health. Especially during concentrated work like a dentist does. That‘s why it has always been a challenge for KaVo to reduce the noise level of KaVo turbine handpieces simultaneously to all the other high tech innovations: KaVo development of noise reduction: 1958 : KaVo Borden-Air 58 78 dB(A) 1970 : KaVo Super All-air 618 75 dB(A) 1977 : KaVo SUPERtorque 630 68 dB(A) 1989 : KaVo SUPERtorque 640 65 dB(A) 2001 : KaVo GENTLEforce 7000 62 dB(A) 2005 : KaVo GENTLEsilence 8000 57 dB(A) 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 fascinating silence GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 fascinating silence Noise level = acoustic pressure + frequency Acoustic pressure (loudness) is measured in Decibel dB (A) and ranges in a progressive scale from 0 to 140 dB (A). The parameters of Decibel- measurement for turbine hand-pieces are well-defined in norm EN ISO 7785-1. (e.g.: measuring distance 45 cm) Only data, which are measured under this EN ISO- norm are objectively comparable. Threshold of pain 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 fascinating silence GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 fascinating silence Acoustic pressure dB(A) Humans sense a reduction of the acoustic pressure by 8- 10 decibel as a bisection of the loudness SUPERtorque 640 65 dB(A) GENTLEsilence 8000 57 dB(A) present turbines 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 fascinating silence GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 fascinating silence Noise level = acoustic pressure + frequency Frequency ( tone / sound ) is measured in Hertz (Hz) and describes the vibration frequency ( rise and fall of acoustic pressure ) per second. Human ears can sense sounds at frequencies from 16 – 16,000 Hz. We are sensing high frequency sounds as very unpleasant and even painful. Low frequency tones we sense as particularly loud. 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 fascinating silence GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 fascinating silence In addition to the reduction of the acoustic pressure ( 57 dB(A) ) we also found a solution to eliminate the high- frequency peaks by using a new technology for fixing the ball bearings on the chuck pleasant to the ear – pleasant for the nerves Basic- frequency : 6 kHz 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 fascinating silence GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 fascinating silence By using a new technology of ball bearings with a one-piece inner ring an extremly well balanced turbine- cartridge guarantees vibration- free performance at only 57 dB(A) with a fascinatingly quiet sound- level KaVo added values: fascinatingly quiet sound level vibration- free performance long-term durability Repair service by exchange of the ball bearings is not possible. 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 fascinatingly quiet – amazing powerful GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 fascinatingly quiet – amazing powerful GENTLEsilence cartridge- design with KaVo original ceramic ball- bearings guarantees longevity with excellent power output: 19 Watt at approx. 200.000 rpm ( Idling speed: 360.000 rpm) This excellent power output already is available at an air pressure of only 2.6 bar / 37 psi. 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 fascinatingly quiet – amazing powerful GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 fascinatingly quiet – amazing powerful automatically regulated air pressure 2,6 bar: 19 Watt power output Even if the air pressure is lower, GENTLEsilence offers more power 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 ingenious angle combination GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 ingenious angle combination Patented KaVo angle combination creates more freedom of movement : head angle 100° and knee angle 19° 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 ingenious angle combination GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 ingenious angle combination Freedom of movement by perfect angle combination, coordinated design and smallest headsize unimpeded work – exact preparation – gentler treatment Conventional turbine handpieces Working space in molar area often too tight Limitation due to contact with anterior teeth GENTLEsilence 8000 Excellent working space due to perfect angle combination and smallest headsize. 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 freedom of movement in the premium class GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 freedom of movement in the premium class GENTLEsilence head housing: smallest of its class 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 freedom of movement GENTLEsilence LUX 8000 B with 19 mm FG-bur 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 freedom of movement GENTLEsilence LUX 8000 B 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 Sensitivity for precision GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 Sensitivity for precision Sensitivity and tactile- feeling through KaVo Plasmatec- coating and optimized material : grip- sleeve made of stainless steel improved grip - unique handling 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 Sensitivity for precision GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 Sensitivity for precision KaVo Plasmatec coating-process : PVD - Physical Vapor Deposition Basic-material Plasma GENTLEsilence steel sleeve Through a light-arch at a temperature of approx. 10,000 0 C the basic material changes his physical aggregate state up to the 4th level – PLASMA. At a temperature of 250 0 – 300 0 C the plasma, which is mixed with inert gas, falls on the surface of the GENTLEsilence sheath. Metal-ceramic surface which is twice as hard as stainless steel 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 Sensitivity for precision GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 Sensitivity for precision Plasmatec coating-process : KaVo Hygiene Seal- coating After PVD-processing the metal-ceramic surface will be finished in a special-process with a second coating : KaVo Hygiene Seal-coating The surface with human touch improved grip more sensitivity enhanced hygiene 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 automated optimal GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 automated optimal Integrated pressure-regulation-valve for automated adaption to the optimal air pressure ( 2.6 bar / 37 psi ) optimum power usage and best longevity of the cartridge 2, 6 bar 37 psi 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 clean and hygienic GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 clean and hygienic Anti-Suck-Back due to unique KaVo cartridge-design which prevents contaminated particles and dirt to enter the head housing. GENTLEsilence 8000 Conventional cartridges Over-pressure build-up during runing-out time of cartridge - no chance to enter Low-pressure build-up with suck- back effect during runing-out time of cartridge 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 reliable clean GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 reliable clean Exchangeable microfilter in spray-water channel guarantees efficient and reliable spray- cooling at all times. easily exchangeable by the assistant 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 optimal cooling GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 optimal cooling Optimal cooling of the bur through 4- hole spray with finest spray coverage all the way to the bur- tip Spray cooling : 15 – 25 mm 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 powerful and safe GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 powerful and safe KaVo push-button-system guarantees safe and strong grip of the bur with excellent handling-comfort Holding strength of chuck-system: 32 N Burs: shaft diameter: 1.59–1.60 mm cutting diameter: max. 2.0mm total length : max . 25 mm ( norm DIN EN ISO 1797-1 ) 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 always high visibility GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 always high visibility Glas-Rod Cellular Optics ( 25,000 LUX ) – best illumination of preparation- area without degredation of light transmission even after 1,000 sterilization cycles and more 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 MULTIflexible KaVo MULTIflex-System universal GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 MULTIflexible KaVo MULTIflex-System universal MULTIflexible futuristic 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 Hygiene without risk GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 Hygiene without risk washable in Thermo-disinfector sterilisable up to 1350 C / 275° F 27.12.2018 - © KaVo Dental GmbH

KaVo GENTLEsilence 8000 Thank you for your attention GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 Thank you for your attention 27.12.2018 - © KaVo Dental GmbH