Henry Ford Health System

Slides:



Advertisements
Similar presentations
Managing the LVAD patient in Cardiac Rehabilitation
Advertisements

Community Preparation for Caring for Mechanical Circulatory Device Patients University of Wisconsin Hospital And Clinics Ventricular Assist Device Program.
Left Ventricular Assist Devices “LVAD”
BACKGROUND Ventricular assist devices (VADs) are a proven therapy as bridge-to-cardiac transplantation in Class IIIB and Class IV heart failure patients.
Congestive Heart Failure
Important Concepts Associated with the Measurement of Blood Pressure.
1 CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. Refer to the “Instructions For Use” for complete Indications.
Chapter 15 Bleeding and Shock
1 CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. Refer to the “Instructions For Use” for complete Indications.
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
BACKGROUND Ventricular assist devices (VADs) are a proven therapy as bridge-to-cardiac transplantation in Class IIIB and Class IV heart failure patients.
What do they assess? What can they tell you? Why are they important? Are they objective or subjective? Think about how they can help you ANTICIPATE a.
Clinical Assessment of Pulsatile and Non-Pulsaltile VADs Diana Joseph RN, BSN, CCTC VAD/Heart Transplant Coordinator OSF St. Francis Medical Center Peoria,
LVAD is a battery-operated, mechanical pump-type device that's surgically implanted. Goal of LVAD: providing the patient with as close to a normal lifestyle.
Vitals and History Taking Hillcrest Fire Training December, 2000.
Bleeding and Shock CHAPTER 25 1.
FO1 Marko D Mission EMT-B Bureau of Fire Protection.
Chapter 15 Assessment of Cardiac Output
Community Preparation for Caring for Mechanical Circulatory Device Patients University of Wisconsin Hospital And Clinics Ventricular Assist Device Program.
Chapter 6 AED.
Ventricular Assist Devices Brian Schwartz, CCP February 25, 2003.
Algorithms  Bradycardia with a Pulse Stable Cardiopulmonary status Cardiopulmonary Compromise  Tachycardia with Pulses and Poor Perfusion Sinus Tachycardia.
A Case Study. The background You admitted MB after a LIMA-LAD, SVG x2, initial vital signs were stable – HR 75, BP 114/73, CVP of 5, Cardiac index was.
Advances In LVAD Patient Management
Introduction to Ventricular Assist Device (VAD)
Ventricular Assist Devices
9/5/20151 Ventricular Assist Device (VAD) Patients in the Community Liz Amerman, RN, BSN IU Health Methodist VAD Program Manager April 18, 2012.
CONCEPTS OF NORMAL HEMODYNAMICS AND SHOCK
Prepared by the Division of Emergency Medical Services Refresher Course Medical Incident Report Form Education Module for 2009 Prepared by the Division.
DUCS and RATS INTEGRIS Health.
Sport Books Publisher1 The Heart and Lungs at Work Chapter 7.
Community Preparation for Caring for Mechanical Circulatory Device Patients University of Wisconsin Hospital And Clinics Ventricular Assist Device Program.
Top Ten things you need to know… About VAD’s Kim Byrum Chappell Mechanical Assist Coordinator.
Ventricular Assist Devices A Ventricular assist device, or VAD, is a mechanical circulatory device that is used to partially or completely replace the.
Risk Factors for Adverse Outcome after HeartMate II Jennifer Cowger, MD, MS St. Vincent Heart Center of Indiana Advanced Heart Failure, Transplant, & Mechanical.
Mosby items and derived items © 2007, 2004 by Mosby, Inc., an affiliate of Elsevier Inc. Cardiopulmonary Resuscitation and AED Chapter 8.
Cardiovascular Assessment II Yuriy Slyvka MD, PhD.
Cardiac Cath and Angiocardiography Adult II FINAL 2/2015.
CARDIOHELP TRAINING June 18-19, 2013
Ihab Alomari, MD, FACC Assistant professor – Interventional Cardiology University of California, Irvine Division of Cardiology Cath Lab Essentials : LV.
U.S ARMY HEALTH CARE B/P LAB. 2 SGT Chase Johnson Army Health Care Recruiter U.S Army Medic ( 68W) Emergency Medical Technician (NREMT) Advance Cardiac.
Chapter 6 Vital Signs Assessment. Vital Signs Used to assess the conditions of the various body systems, particularly the respiratory and circulatory.
The Cardiac Cycle. Learning Objectives  To identify & describe the main parts of the cardiac cycle  To describe how the cardiac cycle is controlled.
FIRST AID AND EMERGENCY CARE LECTURE 4 Vital Signs.
Conflict of Interest Baxter Research Grant Medtronic Research Grant
Capnography: Defined and Clinical Applications
Chapter 6 Vital Signs.
Cardiopulmonary Resuscitation
Pediatric Basic Life Support
Ventricular Assist Device
Ventricular function recovery on LVAD For idiopathic or ischemic CM
Advanced Life Support.
Cardiac arrest & Reactivation
University of Wisconsin Hospital And Clinics
Measurement of Arterial Pressure
Continued Scene Assessment
Blood Pressure August 2015 Blood Pressure.
Chapter 8 Circulation Limmer, First Responder: A Skills Approach, 7th ed. © 2007 by Pearson Education, Inc. Upper Saddle River, NJ.
Intro to First Aid and CPR
1.4 Copyright UKCS #
Mechanical Circulatory Support Devices HOSEIN PASANDI.
Vital Signs Assessment
Durable Mechanical Circulatory Support in Advanced Heart Failure
Advances and Future Directions for Mechanical Circulatory Support
The Crashing LVAD Chanel Fischetti, MD
Pericarditis Inflammation of the pericardium Many causes
Heartware HVAD Ventricular Assist System
New changes for CPR 2006.
Unit 16 Primary Assessment.
Presentation transcript:

Henry Ford Health System HENRY FORD HOSPITAL Ventricular Assist Device Program: Emergency Department Education Henry Ford Health System

Agenda Definition of a VAD Current LVADs Basic LVAD function & Key differences Stable VAD patient in ED Unstable VAD patient in ED

WHAT IS A VAD? A Ventricular Assist Device (VAD) is a mechanical circulatory support device used to treat heart failure patients. It helps a weakened heart pump blood throughout the body. Although VADs can provide right, left, or biventricular support, the LVAD (left ventricular assist device) is the most common. Patients are usually discharged home on these devices.

* 07/16/96 These pumps differ in technical design, but all are continuous-flow pumps and have the following analogous components: an inflow cannula that is surgically implanted into the left ventricular (LV) apex, serving as a conduit for blood from the LV to the pump; 2) a pump enclosure which houses an impeller that circulates blood; 3) an outflow graft that carries blood from the pump to the systemic circulation; and 4) a surgically tunneled driveline that connects the pump to an external controller that operates and monitors the pump function. The external controller is connected by 2 power cables to a battery powered source or a power module connected to an AC source while batteries are charging. *

Basic LVAD function LVADs move blood from the LV apex to systemic circulation in a continuous manner Controller: Speed (RPM), Flow (L/min), Power (watts), PI (pulsatility index) Pump speed is the fundamental parameter that the provider can alter The system controller monitors power consumption and estimates cardiac output based on speed and power consumption may not be accurate in the case of physiologic derangements (e.g., AI or LVAD dysfunction including pump thrombosis) Additionally, the controller measures temporal power fluctuations to give an estimate of pulsatility through the pump, termed pulsatility index for HeartMate devices and represented graphically as the HVAD pump flow waveform for the HeartWare device Contemporary pump design and operating software are unable to automatically modulate speed or cardiac output based on physiologic demand; therefore, they will operate at the speed the provider sets, consuming as much power as needed to maintain that speed.

* 07/16/96 Key Differences HVAD and HM 3 provide more accurate CO estimates compared to HM 2 HVAD and HM 3 have a larger change in flow for a given pressure gradient change across the pump than HM 2 centrifugal flow pumps are more sensitive to changes in preload and afterload, and controlling hypertension is a key element of normal centrifugal flow pump function HVAD and HM 3 have automated speed modulation capabilities to enhance washing of the pump and allow possible intermittent ejection through the native aortic valve. These rapid speed modulations, termed “Artificial Pulse” for HM 3 and “Lavare Cycle” for HVAD may have benefits in preventing pump thrombosis, AV insufficiency and stroke. -(centrifugal design, and by using the patient’s manually entered hematocrit to estimate the serum viscosity. *

HeartMate II Left Ventricular Assist System * 07/16/96 HeartMate II Left Ventricular Assist System Implantable Pump Batteries The HeartMate II Left Ventricular Assist System consists of an implantable pump, percutaneous lead, microprocessor-based system controller, and portable power source. Percutaneous Lead Controller *

HMII VAD FLOW Press to see flow VAD flow is visible on the power module (circled) and the controller. Click square button on controller to see Liters per min Flow is like cardiac output (3-6 ok)

HeartMate II VAD POWER SOURCES VAD must be connected to AC power or batteries AT ALL TIMES! Batteries last ~10-14 hours. *If patient connected to AC (wall) power and power goes out, power module (PM) will provide only about 20 minutes backup power…switch patient from PM to batteries immediately! HeartMate II drains both batteries simultaneously.

HVAD® System Configuration Controller Battery

HVAD® System Components HVAD™ Controller HVAD™ Pump HVAD™ Monitor HVAD™ Controller AC Adapter HVAD™ Controller DC Adapter HVAD™ Batteries & Battery Charger

HVAD™ Controller Flow and speed on controller screen! Requires two power sources at all times: 2 batteries 1 battery & AC or DC Adapter Batteries 10-16 Hrs Need Doppler to measure BP Doppler opening sound approximates mean arterial pressure (70-90 mmHg goal) in most patients speed flow

HeartMate 3 LVAD Has engineered pulsatility in pump to “mimic” a pulse. May or may not get cuff BP: Goal SBP <110 mmHg Goal MAP 70-90 mmHg Doppler may approximate MAP (if not pulsatile) or SBP! If Doppler 70-100 mmHg probably ok. Doppler here will approximate SBP not MAP because wide pulse pressure in patient

GUIDANCE FOR EMERGENCY MEDICAL SERVICES TEAMS In the event of an emergency, all efforts should be made to direct patients with MCS to their respective MCS/left ventricular assist device (LVAD) centers. It is crucial that emergency medical services personnel make every effort to bring the patient's peripheral equipment needed to maintain LVAD/TAH function (including the batteries, power base unit, and controllers), even if this entails a slight delay in transporting the patient. This equipment will be needed to support the patient until he or she can be transferred to his or her LVAD center.

Major Adverse Events

Stable VAD Patient in Emergency Room Connect patient to power module (PM) to get VAD numbers and obtain basic vital signs. Doppler BP O2 saturation may be inaccurate on VAD Keep patient caregiver with patient. Follow VAD Emergency Department Algorithm. Notify cardiology fellow and VAD coordinator @ (313) 705-0089

Clinical Assessment of a Conscious LVAD patient * 07/16/96 Clinical Assessment of a Conscious LVAD patient History Device parameters and alarms Symptoms of infection; including driveline Symptoms of HF Signs of hemoglobinuria (dark urine) Signs of bleeding Physical exam: Cardiac examination! Measurement of BP Assessment of perfusion by skin temperature and capillary refill since there is often no palpable pulse Assessment of signs of right heart failure (JVD, hepatomegaly) Driveline Device connections Document Flow, speed, power, pulsatility index, rate -no pulse, minimal pulse pressure, and no discernable heart sounds, which makes cardiac assessment difficult *

Pulse Underlying LV contractility AV function LVAD pump speed * 07/16/96 Pulse Underlying LV contractility AV function LVAD pump speed LVAD preload and afterload Assessments of heart rate often require telemetry or electrocardiography instead of palpation of a pulse, which is often absent. *

* 07/16/96 Blood Pressure Propeller inside pump spins blood through providing CONTINUOUS FLOW. Narrow pulse pressure: These patients may not have a radial pulse! Carotid pulse is palpable Due to continuous flow you will likely need a Doppler to get a blood pressure on this patient. The sound you hear when deflating the cuff will often be reflective of the mean arterial pressure (MAP), not systolic. A “perfect MAP” is 70-90 mmHg A dangerously low MAP is ≤50 mmHg Noninvasive BP measurements are difficult in CF LVAD patients due to diminished pulse pressure, and automated BP monitors may fail to measure BP. Doppler ultrasound is recommended as the most reliable noninvasive method to assess BP in CF LVAD patients. -The pressure at which the sound of blood flow returns to the brachial artery is recorded and best described as an opening or Doppler pressure, although in practice it is often called a mean arterial pressure (MAP). If a patient has significant pulsatility, then the opening pressure likely represents systolic BP. If there is low pulsatility, then the opening pressure gives a reasonable estimate of the MAP. Narrow pulse pressure mean Doppler opening pressure is closest to MAP *

VAD Patient Transport Take extra batteries and controller with patient (or just take PM cart with those items inside). Allow caregiver to stay with patient if possible. Patients only admitted to P5 or H5.

VAD Patient EMERGENCY in ER VAD TEAM PAGER: (313) 705-0089 On call 24 hours, 365 days a year If no response, keep paging and call attending CHF/Transplant MD on call.

VAD EMERGENCY PRECAUTIONS Feel carotid pulse- radial pulse may not be present. Be mindful of unique BP measurement needs in VAD patients and pulse ox inaccuracies! 70-90 mmHg perfect for mean arterial pressure ≤50 mmHg is emergent! CHECK LVAD CONNECTIONS! Flow of 3-5L usually perfect. If flow is very low: Bleeding? Tamponade? VAD failure or VAD obstruction?

Approach to the Unconscious LVAD patient * 07/16/96 Approach to the Unconscious LVAD patient If pulse present and Doppler BP > 50mHg: Consider non-LVAD causes for unresponsiveness: - Stroke - Hypoglycemia - Overdose - Hypoxia *

Approach to Hypotension in a Conscious LVAD patient

ACLS Indications ACLS may be needed if Not conscious No carotid pulse Mean arterial pressure ≤50 mmHg by Doppler Oxygenation impairment or signs of malperfusion on exam (color, temperature, capillary refill) Use AHA algorithm on CPR rate, depth, airway management

Adult CPR in LVAD patient VF/VT? Is there a carotid pulse present? Doppler preferred Is patient conscious Check BP: Doppler needed! No No Yes VT/VF resolved but unconscious Yes NO or Yes: While waiting for Coordinator, begin secondary assessment Yes No Are LVAD controller and Batteries Hooked up? Doppler or MAP <50 Doppler or MAP ≥50 Shock per ACLS guidelines No Doppler BP available, Signs of malperfusion or instability No Begin VAD Arrest: Standard ACLS Epi Chest Compressions Shock when indicated Ongoing VT/VF Call Coordinator and on-call Fellow Assess BP and VAD flows every 2 min Call Coordinator VAD Coordinator: (313) 705-0089

VAD Emergencies VT/VF: Patient may or may not be stable on LVAD support Unstable patient: defibrillation ok up to 200 J. Do not disconnect VAD. Don’t stress over pad placement Stable patient: call cardiology fellow Can try amio bolus 150-300 mg. Risks of persistent VT/VF are device clot, RV failure and cardiogenic shock (RV is impacted by VT/VF and LVAD won’t fill). Would not leave in VT/VF for >30 min, even if stable OK to sedate and shock if needed.

Key Facts on VADs Do not get any part of any VAD wet. A carotid pulse is palpable. Radial and femoral pulses are often not palpable. Pulse Ox values are often inaccurate! Usually need a Doppler to measure blood pressure. Good number is an opening pressure of 70-90. Pump flow is what is supplementing cardiac output. Good flow is 3-6 L Defibrillation for VT/VF and CPR is safe. Do NOT disconnect LVAD CPR is provided according to algorithm.

On call 24 hours, 365 days a year TAKE HOME MESSAGE VAD TEAM PAGER: (313) 705-0089 On call 24 hours, 365 days a year If no response, keep paging and call attending CHF/Transplant Cardiology on call. Dr. Cowger is Medical Director of program for any concerns: 734 546 4911 (cell)

References 1. American Heart Association, May 2017. Cardiopulmonary Resuscitation in Adults and Children with mechanical Circulatory Support. A Scientific Statement From the American Heart Association. Peberty, M., Gluck, J. et al. Dallas Texas. AMHA. 2. http://www.thoratec.com/medical-professionals/vad-product-information/heartmate-ll-lvad.aspx 3. https://www.sjm.com/en/professionals/featured-products/heart-failure-management/mechanical-circulatory-support/left-ventricular-assist-device/heartmate-3-left-ventricular-assist-system?clset=af584191-45c9-4201-8740-5409f4cf8bdd%3ab20716c1-c2a6-4e4c-844b-d0dd6899eb3a 4. https://www.heartware.com/ 5. The 2013 International Society for Heart and Lung Transplantation Guidelines for Mechanical Circulatory Support: Executive Summary. The Journal of Heart and Lung Transplantation, Vol 32, No 2, February 2013. http://dx.doi.org/10.1016/j.healun.2012.09.013 6. Waqas M and Cowger JA. Role of Mechanical Circulatory Support. Heart Failure Clinics 2016;12:399-409. PMID: 27371516. 7. Trauma Resuscitation in a Left Ventricular Assist Device Patient: An Emergency Medicine Simulation Scenario. Cureus. 2017 Oct; 9(10): e1773. doi: 10.7759/cureus.1773 8. Algorithms to guide ambulance clinicians in the management of emergencies in patients with implanted rotary left ventricular assist devices. Emerg Med J. 2017 Dec; 34(12): 842–850. doi: 10.1136/emermed-2016-206172 9. Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure. N Engl J Med 2018; 378:1386-1395. DOI: 10.1056/NEJMoa1800866 10. Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure. N Engl J Med 2017; 376:451-460 DOI: 10.1056/NEJMoa1602954.