2.3 Waste Management – Revised IBTS

Slides:



Advertisements
Similar presentations
Air Emissions Regulations Update Tripartite meeting 15/16 September 2006; Seoul
Advertisements

Environmental Stewardship IMO standards: - Oily Waste Pollution Prevention Management - Add-on equipment to existing PPEs Wednesday, 9 December 2009.
Standards for Handling Oily Wastes in Machinery Spaces
Unit C: Agricultural Power Systems
Sewage Treatment.
The fuel system Fuel pumps Engine mu.
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
Anglo Eastern Maritime Training Centre A CASE STUDY ON OWS- ABUSE!!
Inspected in port Shanghai from 26th to 28th Sept by NCL
IASST International Association For Safety and Survival Training 7 th International Conference October 9 th -10 th,2006 Sibenik Croatia.
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
PureDry Waste fuel recovery Forum 25th April 2014 Dimitris Poulos ALFA LAVAL AEBE.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Port Reception Facilities Curtis A Roach Regional Adviser (Caribbean) International Maritime Organization FIRST HEMISPHERIC CONFERENCE ON ENVIRONMENTAL.
Machinery Auxiliary Systems
CLEAN and CLEAN DESIGN Environmental Class Eivind Haugen, Det Norske Veritas Norske Sivilingeniørers Forening Økonomisk og Miljøvennlig drift av skip.
LESSON FOURTEEN. WATER COOLING SYSTEM 1.HEAT SOURCES.
Basics of Pump Vigyan Ashram, Pabal.
Shipboard waste management Possible improvements Tripartite meeting 15/16 September 2006; Seoul
Marine Oily Handling Devices and Pollution Prevention Chapter 2 Lesson 3 Pre-treatment of Marine Fuels.
AQUATEST a.s. TECHNICAL SUPPORT DIVISION Modular units for mine water disposal A set of technical equipment designed for mine water disposal is.
Green Ship Design Design for Environmentally Friend Ship in Shipbuilding ・ Less Hazardous Materials ・ Less CO 2 Demand for Ship Operation ・ Less Engine.
Sanitary System. Function the SANITARY system handles waste water from wash basins, sinks, showers baths, galley equipment as well as waste water from.
Bilge System.
 UAB Vilniaus waters - the largest water company in Lithuania, which operates not only in the city of Vilnius, but also the district, Svencionys and.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Hydronic Mechanical Controls
Sea Water Scrubber. INTRODUCTION Crystallox has developed a new generation of horizontal and vertical scrubbers for marine and land based applications.
Dewatering Equipment.
GEOTHERMAL POWER PLANT
Plan 2 – Dead-end Seal Chamber Optional Jacket
GWS SMS INTRODUCTION EMS Manual. 3. PROCEDURES FOR BILGE AND WASTE OIL MANAGEMENT OF MACHINERY SPACES As far as possible, the OWS must not be used.
Shanghai International Maritime Forum 2007 Oil Transportation and Pollution Prevention Tim Wilkins 国际油轮船东协会 Regional Manager Asia-Pacific Environmental.
 2009 Watch keeping principle Watch keeping principle- Simple mistakes leads to serious damages.
exhaust regulator valve
Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Green Ship Technology Asia – Hong.
WATER COOLING SYSTEM. 1.HEAT SOURCES  Burning of fuel  Heat developed by compression of air  Frictional heat.
Tomislav Skračić, MA Undergraduate English Course for MARINE ENGINEERS 5th Semester Essential reading: SPINČIĆ, A., PRITCHARD, B, An English Textbook For.
LESSON THIRTEEN LUBRICATING OIL SYSTEM. 1.PRIMARY PURPOSE OF LUBRICATION To keep a clean layer of lubricating oil film / luboil film between the contacting.
SUBJECT CODE NAME OF SUBJECT TOPIC :::::: FLUID POWER ENGINEERING CENTRIFUGAL PUMP Parul Institute of Engineering & Technology.
Collection and Treatment of waste material in Port of Koper Kristifor Pantelin Brindisi,
Weekly Checks Monday – VSP Room Tuesday – Pilothouse System Controls Wednesday – Starboard / Engine Room Thursday – Foam Room Friday – Port / Engine Room.
Monday – VSP Room weekly checks Visually Check: Hvac system for leaks & valve settings Fresh water system for leaks & valve settings VSP linkage Autopilot.
Raw Water System Flush By introducing fresh water into the cooling system, growth of sea life is reduced or eliminated keeping the raw water cooling pipes.
Oil Pollution. Causes of oil pollution A. Engine oil leaking or deliberate discharge B. Industrial machine oil leaking into drains C. Dumping of water.
Fire/General Service/Ballast Pumping Systems
Bilge Pumping Systems General Locations.
Machinery Cooling Water System Locations and Operations.
Last Question of the Day- For first semester! 1. How do you get the waste out of wastewater o For Friday, please gather all Questions of the day to turn.
Coolant Fill Coolant Check and Fill. Oil Fill & Dip Stick Main Engine Oil Fill Dip Stick Delo 400 – 40 wt. Engine Oil.
CABIN DESCRIPTION - Water and Waste System Presentation 1/5.
Wednesday – starboard side engine room weekly checks Cycle all valves on the starboard side of the engine room Check all systems, connections, valves,
Boiler Safety Valve Regulations
TOPIC Collection, Transport and Storage of waste All waste arising should be accumulated at the point of origin. Such waste material must also.
Chapter 4. 1 The engine does start on air, but combustion does not immediately begin. What is the possible cause? Low air compression , failure in the.
Chapter 2 Topic narration. 1. Please describe the difference between the diesel engine and the gasoline engine. The diesel engine is different from the.
General Locations and Operation
Oily water treatment system Oily water treatment
MARPOL.
Chapter 6 Question-and-Answer.
Friday – port side engine room weekly checks
ENVIRONMENTAL SHIP MANAGEMENT AND ASSESSMENT
REPORT IN AUX MAC PAQUIBOL, MARK ANGELO B. ME31-A1 ENGR. ALMOJUELA.
Vapor Emission Control System
Transformer system Transformer oil cooling and cleaning
CONSTANTA MARITIME UNIVERSITY FACULTY OF MARINE ENGINEERING Engineering programmed: Marine Engineering (Bachelor’s Degree) THE STUDY OF BALLAST SYSTEM.
Firefighting equipment
Simple and Easy Oil/Grease contaminated water clean up
Preventive Maintenance
Presentation transcript:

2.3 Waste Management – Revised IBTS Regulation 12 – Tanks for oil residues Integrated Ballast Treatment System Separation of Clean and Dirty Drains Pre-treatment of Oily Drains Minimum Sludge Tank Capacity Revoking of UI 15.1.5 (Minimum Sludge Tank Capacity is 50% if an Homogenizer or Sludge Incinerator is fitted)

Regulation 12 – Tanks for Oil Residues 2 Oil residues (sludge) may be disposed of directly from the oil residue (sludge) tank(s) through the standard discharge connection referred to in regulation 13, or any other approved means of disposal. The tank(s): .1 shall be provided with a designated pump that is capable of taking suction from the oil residue (sludge) tank(s); .2 shall have no discharge connections to bilge system, oily bilge water holding tanks, tank top or oily water separator; and .3 may be fitted with drains, with manually operated self-closing valves, for the collection of settled water or an alternative arrangement, provided such arrangement does not connect directly to the bilge piping system.

Integrated Bilge Treatment System Clean Drains Main Engine Air Cooler Drain Cooling Fresh Water, Sea Water Steam Drain, Boiler Water Drain to the Clean Drain Tank and can be Pumped directly overboard.

Integrated Bilge Treatment System Oil Residues (Sludge) Hydraulic Oil Pump & Tank Coaming Drain Waste Oil Pump & Tank Coaming Drain LO Pump & Tank Coaming Drain Bilge Equipment Coaming Drain Main Engine Scavenge Drain Compressed Air Drain Purifier Sludge Bilge Primary Tank (Oil Side) Workshop Drain Drain to the Sludge Tank for discharge Ashore or Incineration

Integrated Bilge Treatment System Oily Bilge Water Engine Room Scuppers Engine Room Bilges Drain/Pumped to Primary Bilge Tank for pre-treatment to separate oil and water phases. Water side drains to Bilge Holding Tank and discharge via OWS Oil Side Drains to Sludge Tank

Example of a Bilge Primary Tank

Minimum Sludge Tank Capacity Incinerators Operation during Manned periods only, e.g. 8 hours per day. Port stays and stand by passages restrict operation. Homogenizers Effectiveness UI 15.1.5 will be revoked with amendments to MARPOL Annex I