The pros and cons of in-situ testing – going beyond the test standards

Slides:



Advertisements
Similar presentations
Ch8 Inverters (converting DC to AC)
Advertisements

Analog-to-Digital Converter (ADC) And
Learning Objectives Static and Dynamic Characteristics of Signals
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 26.1 Data Acquisition and Conversion  Introduction  Sampling  Signal Reconstruction.
Cross-Over Distortion The non-zero “turn-on” voltage of a transistor causes cross-over distortion in a class B output stage. Approximate transistor response.
DC Characterization of CCD-Based Detectors for Use in Multi-Chip Focal Plane Arrays SDW 2005 June 2005, R. PhilbrickBall Aerospace & Technologies Corp.
©Ian Sommerville 2000 Software Engineering, 6th edition. Chapter 15Slide 1 User interface design l Designing effective interfaces for software systems.
PH4705/ET4305: A/D: Analogue to Digital Conversion
Digital to Analog Converters
User interface design. Recap User Interface GUI Characteristics (Windows, Icons, Menus, Pointing, Graphics) User Centered Design User Interface Design.
Classification of Instruments :
1 Cessna EME Lab Reverb Chamber Emissions Matthew Wills EME Lab Supervisor December 7th, 2004.
Department of Electrical & Computer Engineering 1 ES585a - Computer Based Power System Protection Course by Dr.T.S.Sidhu - Fall 2005 Class discussion presentation.
SCADA and Telemetry Presented By:.
EKT314/4 Electronic Instrumentation
DIGITAL VOICE NETWORKS ECE 421E Tuesday, October 02, 2012.
Lecture 1 Signals in the Time and Frequency Domains
Vector Control of Induction Machines
Analog and Digital Instruments
INTRODUCTION TO MEASUREMENT
Total Dose Effects on Devices and Circuits - Principles and Limits of Ground Evaluation-
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
AMICSA DUTH/SRL GK Methodologies for designing radiation hardened Analog to digital converters for space applications. DUTH/SRL George Kottaras, E.T. SarrisNick,
Slide 1 5th LHC RADIATION WORKSHOP, CERN, , Jochen Kuhnhenn, Fraunhofer INT Radiation tolerant fibres for LHC controls and communications.
Digital to Analog Converter (DAC)
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
Topics 1 Specific topics to be covered are: Discrete-time signals Z-transforms Sampling and reconstruction Aliasing and anti-aliasing filters Sampled-data.
PIONEERING WITH PASSION ©Tesat-Spacecom GmbH & Co.KG PIONEERING WITH PASSION PROPRIETARY INFORMATION ©Tesat-Spacecom GmbH & Co.KG reserves all rights.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
A DSP based on on-line UPS R.Padamaja G.Mamatha Reddy EEE EEE S.V.C.E S.V.C.E BY.
FUNCTION GENERATOR.
Let S is the space of discrete-time signals. A signal in S is a function defined only on the integers and is visualized as a sequence of numbers,
Enhancement Presentation Carlos Abellan Barcelona September, 9th 2009.
Electric Pressure Transducer
Unit IV Finite Word Length Effects
Microprocessors Data Converters Analog to Digital Converters (ADC)
IEEE NPEC SC2 Equipment Qualification Electromagnetic Compatibility Compliance Type Test-Design Considerations- Installation and Mitigation Standard/Guidance.
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
Comparison Study of Bulk and SOI CMOS Technologies based Rad-hard ADCs in Space Feitao Qi , Tao Liu , Hainan Liu , Chuanbin Zeng , Bo Li , Fazhan Zhao.
EKT124 Digital Electronics 1 Introduction to Digital Electronics
Digital Control CSE 421.
MECH 373 Instrumentation and Measurement
Introduction to Electronics
Potential and Current Control
Performance characteristics
SCADA for Remote Industrial Plant
VARACTOR DIODE CORPORATE INSTITUTE OF SCIENCE & TECHNOLOGY , BHOPAL
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
The operational amplifier, cont.
Analog and Digital Signals
Unit - 5 Analog and Digital Instruments. Digital Voltmeter (DVM) Used to measure the ac and dc voltages and displays the result in digital form. Types:
IEEE Regulatory AHC Power Measurement Method
BASICS OF MEASUREMENT AND INSTRUMENTATION
Ideal Filters One of the reasons why we design a filter is to remove disturbances Filter SIGNAL NOISE We discriminate between signal and noise in terms.
Analog and Digital Signals
Analog & Digital Signals
High Efficiency, Low Voltage Output DC-DC Converter Solutions
Studies of the effect of the LHC cycle on
Digital Control Systems Waseem Gulsher
Analog & Digital Signals
Chapter 6 Discrete-Time System
Analog and Digital Instruments
Radiation tolerant fibres for LHC controls and communications
Data Acquisition (DAQ)
GRAPHICAL USER INTERFACE GITAM GADTAULA. OVERVIEW What is Human Computer Interface (User Interface) principles of user interface design What makes a good.
GRAPHICAL USER INTERFACE GITAM GADTAULA KATHMANDU UNIVERSITY CLASS PRESENTATION.
Measurements & Error Analysis
Basic Steps in Development of Instruments
Instruments & Electrical Measurements Lecture 4
CHAPTER 59 TRANSISTOR EQUIVALENT CIRCUITS AND MODELS
Presentation transcript:

The pros and cons of in-situ testing – going beyond the test standards Richard Sharpa, Jiri Hofmana,b and Jiri Hazeb a: Cobham RAD Solutions, Harwell, UK b: Brno University of Technology, Czech Republic AMICSA, 15 June 2016

In-situ testing Introduction What do the standards say? Assumptions made in the standards Advantages and disadvantages of in-situ measurement Case study Points to take away today 28 December 2018

Introduction In-situ testing means the measurement of parameters of electronic components at the same time as they are being irradiated during a total integrated dose (TID) test In-situ means that the test samples are left in the radiation field at the same time as being measured, i.e. the irradiation is continuous Remote testing means that, each time the electrical parameters are measured, the irradiation is stopped, the test samples are removed from the irradiation facility, electrically tested and then returned for the next stage of irradiation 28 December 2018

What do the standards say? ESA ESCC 22900 In-situ testing is permitted either during or after irradiation “In the case of applications for which TDE is important, the advantages of each method shall be carefully weighed against the disadvantages” “… a control device shall be measured with the measurement system before the insertion of the test devices and again upon completion of the irradiation and measurement series …” For evaluation testing, remote testing is mandated: “Multiple exposures shall be used, with monitoring of electrical parameters in between” For qualification and LAT, remote testing is assumed but in-situ measurement is implicitly permitted 28 December 2018

What do the standards say? Mil-Std-883 method 1019 In-flux testing is permitted “The use of in-flux testing may help to avoid variations introduced by post-irradiation time dependent effects” The language of the standard is generally neutral between in-flux and remote testing, allowing both in all circumstances 28 December 2018

Assumptions in the standards Whilst both standards permit in-situ measurement, the majority of the text assumes that remote measurement is undertaken with a small number of discrete irradiation steps, yielding data at only a small number of values of total dose Recommendations are made concerning the number of dose steps (implied remote testing) and the time constraints around remote testing 22900: minimum of three dose steps 1019: no minimum number, i.e. one data point is acceptable Both standards note that in cases where post-irradiation time dependent effects have an influence then this shall be considered when selecting the test method In practice, most tests use remote measurement and a very small number of dose steps 28 December 2018

Advantages of in-situ testing More data give much finer resolution on the total dose scale Subtle and non-linear effects can be identified Avoids errors due to annealing/TDE between the end of an irradiation step and measurement Measurement can continue uninterrupted after removal of the source, i.e. capturing the immediate annealing behaviour (magnitude and rate) Particularly suitable for DC and low frequency parameters Relay multiplexing techniques allow a single instrument to measure multiple DUTs, especially for the total dose range of relevance to space applications 28 December 2018

Disadvantages of in-situ testing Requires a more complex measurement system Long lead lengths make high speed and high frequency measurements difficult Beware of potential radiation effects on the measurement system Complex, digital devices may always need to be taken to a tester Take care to match the bias conditions during measurements to those during static conditions or to minimise the duty cycle Consider measuring a control device periodically to verify no drift has taken place 28 December 2018

Case study Description of the test TID test of a voltage reference with a nominal output of 2.048V Ultralow noise voltage reference using XFET (eXtra implanted junction FET) technology from Analog Devices Three devices irradiated in a 60Co facility at 360 rad[Si]/hr Output voltage measured with a 6.5 digit DMM Constant, stable bias conditions (5V dc) and stable temperature 20 metre cable between the samples and the DMM 28 December 2018

28 December 2018

Data from three dose steps 28 December 2018

Data from in-situ measurements 28 December 2018

Learning points DC and LF signals are easy to measure using in-situ techniques, whereas high speed signals and very low voltages/currents are more difficult to instrument In-situ measurement can reveal unexpected behaviour and yield valuable insights to the radiation-induced changes, especially for parts that exhibit a non-linear response Dose steps should be selected with care to ensure that any unexpected behaviour is captured In-situ testing could be used as a screening test (e.g. evaluation testing) to check for non-linear changes and so to inform the choice of dose steps for a full TID test (qualification or LAT) based upon remote testing 28 December 2018