Technician’s Guide and Workbook for Zoning Section 3: Single Zone Airflow Balancing and Thermostat Location.

Slides:



Advertisements
Similar presentations
Smoke Alarm Placement Example #1 Single story house Laundry Garage Living Dining Kitchen Bedroom Bathroom.
Advertisements

2309 S 6 th St A Pictorial Tour. For sale Classic 100 year old home Estate Sale Over 1700 square feet Three + bedrooms Two baths Two car garage on extra.
Zoning Application. Copyright 2011 Trane 2 Zoning Application Agenda Application Overview --Benefits & Challenges with Zoning HVAC System Designs Conventional.
My house has two floors, I live on one floors, it’s has one garden and one garage, It’s has four windows.
6239 Saranac Ave Norfolk, Va Roland Park 4 bed /2 bath brick home on the water. with a magnificent water view, House next door $280, , across.
ROOM SIZES AND IMPORTANT DIMENSIONS. ROOMS KITCHEN DINING ROOM BEDROOM MASTER BEDROOM BATHROOM FAMILY/LIVING ROOM FOYER / ENTRANCE GARAGE SPECIAL PURPOSE.
House of the Future By Michael Shears. Front of House One floor One floor Insulated with mud Insulated with mud Makes own electricity Makes own electricity.
Designing Functional Interiors &
House Blueprint.
For Sale: 809 California Avenue Ellwood City, PA Look at My Homes, Inc. $149,900.
Planning and Sketching a Floor Plan. Bubble Diagrams Quick Sketches.
By: Joe Ianelli. Style of your home My house is a Ranch style home. The exterior is made with stone and has dark wood on the doors and windows. Windows.
MU Condominium 5,000 Baht per month Maximum number of people per room: 3 (4 in case of a family) 2-bedroom (both large and small rooms) 3,000 Baht per.
Objectives Analyze processes in AHU and buildings.
Trade Skills Duct Sealing. 2 In houses with forced-air heating and cooling systems, ducts are used to distribute conditioned air throughout the.
Decomposing the system.  Here we transfer the analysis model  design model  During system design we have to :  Define design goals  Decompose the.
My House. The Style of my Home The style of my home is New American Craftsman –This spacious home with Great Room, informal and formal dining, a Library,
Thermal Physics III Cooling Processes Refrigerators, air conditioners, and heat pumps are devices that make heat flow from cold to hot. This is called.
15 Minute Leader Lesson Win it in a minute: Conserve resources with home energy management Managing home heat.
Describe, in German, the following: I live in a house. On the ground floor I have a kitchen, bathroom and living room. On the first floor I have 3 bedrooms.
Model Homes.
MLS: Rosellen Ave -5* -Vacant: - This home has a lot of sunshine in it. The finish material is hardwood flooring, carpet and vinyl. The.
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Planning and Sketching a Floor Plan. Bubble Diagrams Quick Sketches.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
3 AREAS of RESIDENCE Sleeping-family sleeps, rests, and baths
Maria’s Restaurant Chapter 2 Section 9
Part 16 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Maria’s Restaurant Lesson 21 Appendix C Duct Design
Planning and Sketching a Floor Plan
Jessica Cardwell Skylar Thomas
Open House Sunday from 10 to 4
ROMAN VILLAS BY BRODY EPHGRAVE.
Maria’s Restaurant Chapter 1 Section 4
Live in the country, enjoy the peace and quite, garden, explore nature
20065 Bartel St. WAS PRICED AT $274,500
Maria’s Restaurant Chapter 3 Section 13
Lesson 24 Appendix F Outside Air Calculation
Part 7 Technician’s Guide & Workbook for Duct Diagnostics and Repair
House for Sale.
Maria’s Restaurant Chapter 1 Section 2
Maria’s Restaurant Chapter 2 Section 8
Technician’s Guide & Workbook for Duct Diagnostics and Repair
Architectural Design Styles of Houses.
Warm-Up Ch3 #4 Gr 6.
Planning and Sketching a Floor Plan
Architectural Design – preliminary sketching
Planning and Sketching a Floor Plan
Homes have Zones We are going to study the different areas of a home.
Planning and Sketching a Floor Plan
Special valuation 2728 S. Manito Blvd. Bonsall-Taylor House
WESLEYAN P-4-8 MAJOR MAINTENANCE FY WASHINGTON STREET
SUITE 3 16' 6" Xl3 7" SUITE Z 14 0 x 16' 0" w (/) 0u0u J LAUNDRY STAIRS DEN 13' 8" X 13 0" KITCHEN 21·2·x 13· 2· I I I I,I,I DINING ROOM 14 ' 4 X 11' 4.
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
Technician’s Guide and Workbook for Zoning Section 1: Introduction
Adding Zones to Existing Systems
Temperature and Comfort Complaints
Zoning Load Calculations
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Zoning Methods There are an unlimited number of ways to zone a home! Popular ways include: More than one single zone HVAC system. Zone damper systems.
Mandatory Design Requirements
Excess Air Management Overview
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Chapter 2 Section 8
Lesson 24 Appendix F Outside Air Calculation
Maria’s Restaurant Chapter 1 Section 2
Architecture Week Two.
Architectural Design – preliminary sketching
Planning and Sketching a Floor Plan
Presentation transcript:

Technician’s Guide and Workbook for Zoning Section 3: Single Zone Airflow Balancing and Thermostat Location

Single Zone Airflow Balancing Balancing is an art based on science. As one does more balancing they become better at balancing and doing the required calculations. This short lesson on balancing is based on Manual B guidance.

One Zone For Whole House Zone 1 2nd Floor Zone 1 1st Floor

1st Floor Manual D CFM Per Diffuser C/H Kitchen 200/100 CFM Great Room 150/100 CFM ½ Bath Laundry Dining Garage 140/90 CFM

2nd Floor Manual D CFM Per Diffuser C/H Bath Bed 2 Master Bedroom 128/130 CFM 200/220 CFM Closet Card Room & Bar 120/130 CFM Bath 330/450 CFM Bed 3

Single Zone Systems In our example home there are seven rooms where the thermostat can be placed

Manual D Design Airflow Totals Room Cooling CFM % Total CFM Heating CFM Kitchen 200 15.8 100 8.2 GR 150 11.9 Dining 140 11.0 90 7.4 Bed 2 128 10.0 130 10.7 Bed 3 120 9.5 MB 220 18.0 CR 330 26.0 450 36.9 Total 1,268 1,220 100.1

Manual D Design Airflow Totals Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Design CFM Final CFM % of Design Kitchen 200 15.8 100 8.2 150 GR 11.9 220 Dining 140 11.0 90 7.4 Bed 2 128 10.0 130 10.7 Bed 3 120 9.5 MB 18.0 CR 330 26.0 450 36.9 410 Total 1,268 1,220 100.1 1,350

Field Airflow Across the Heat Exchanger Total Measured At Diffusers = 1,350 CFM Total Measured Across the Heat Exchanger = 1,432 1,350 ÷ 1,432 = 0.9427 = 94% Air

Manual D Design Airflow Totals 1 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM % CFM Measured Final CFM % of Design Kitchen 200 15.8 100 8.2 150 GR 11.9 220 Dining 140 11.0 90 7.4 Bed 2 128 10.0 130 10.7 Bed 3 120 9.5 MB 18.0 CR 330 26.0 450 36.9 410 Total 1,268 1,220 100.1 1,350

Manual D Design Airflow Totals 2 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Design CFM Final CFM % of Design Kitchen 200 15.8 100 8.2 150 GR 11.9 220 Dining 140 11.0 90 7.4 Bed 2 128 10.0 130 10.7 129 Bed 3 120 9.5 MB 18.0 CR 330 26.0 450 36.9 410 Total 1,268 1,220 100.1 1,350 128 × 0.9 = 115.2 CFM 128 × 1.1 = 140.8 CFM 130 × 0.9 = 117 CFM 130 × 1.1 = 143 CFM

Manual D Design Airflow Totals 3 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Design CFM Final CFM % of Design Kitchen 200 15.8 100 8.2 150 GR 11.9 220 Dining 140 11.0 90 7.4 Bed 2 128 10.0 130 10.7 129 Bed 3 120 9.5 125 MB 18.0 CR 330 26.0 450 36.9 410 Total 1,268 1,220 100.1 1,350

Manual D Design Airflow Totals 3 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Design CFM Final CFM % of Design Kitchen 200 15.8 100 8.2 150 GR 11.9 220 Dining 140 11.0 90 7.4 Bed 2 128 10.0 130 10.7 129 Bed 3 120 9.5 125 MB 18.0 210 CR 330 26.0 450 36.9 410 Total 1,268 1,220 100.1 1,350

Manual D Design Airflow Totals 4 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Design CFM Final CFM % of Design Kitchen 200 15.8 100 8.2 150 GR 11.9 220 Dining 140 11.0 90 7.4 Bed 2 128 10.0 130 10.7 129 Bed 3 120 9.5 125 MB 18.0 210 CR 330 26.0 450 36.9 410 Total 1,268 1,220 100.1 1,350 150 × 0.9 = 135 CFM 150 × 1.1 = 165 CFM 100 × 0.9 = 90 CFM 100 × 1.1 = 110 CFM 120 150 × 0.8 = 120 CFM 100 × 1.2 = 120 CFM

Manual D Design Airflow Totals 5 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Design CFM Final CFM % of Design Kitchen 200 15.8 100 8.2 150 GR 11.9 220 120 Dining 140 11.0 90 7.4 Bed 2 128 10.0 130 10.7 129 Bed 3 9.5 125 MB 18.0 210 CR 330 26.0 450 36.9 410 Total 1,268 1,220 100.1 1,350 160 200 × 0.9 = 180 CFM 200 × 1.1 = 220 CFM 100 × 0.9 = 90 CFM 100 × 1.1 = 110 CFM 200 × 0.8 = 160 CFM 100 × 1.2 = 120 CFM

Manual D Design Airflow Totals 6 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Design CFM Final CFM % of Design Kitchen 200 15.8 100 8.2 150 160 GR 11.9 220 120 Dining 140 11.0 90 7.4 Bed 2 128 10.0 130 10.7 129 Bed 3 9.5 125 MB 18.0 210 CR 330 26.0 450 36.9 410 Total 1,268 1,220 100.1 1,350 140 × 0.9 = 126 CFM 140 × 1.1 = 154 CFM 90 × 0.9 = 81 CFM 90 × 1.1 = 99 CFM 112 140 × 0.8 = 112 CFM 90 × 1.2 = 108 CFM

Manual D Design Airflow Totals 7 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Design CFM Final CFM % of Design Kitchen 200 15.8 100 8.2 150 160 GR 11.9 220 120 Dining 140 11.0 90 7.4 112 Bed 2 128 10.0 130 10.7 129 Bed 3 9.5 125 MB 18.0 210 CR 330 26.0 450 36.9 410 Total 1,268 1,220 100.1 1,350 160 + 120 + 112 + 129 + 125 + 210 = 856 1,350 – 856 = 494 330 × 0.9 = 297 CFM 330 × 1.1 = 363 CFM 450 × 0.9 = 405 CFM 450 × 1.1 = 495 CFM 494 1,350

Manual D Design Airflow Totals 8 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Design CFM Final CFM % of Design Kitchen 200 15.8 100 8.2 150 160 GR 11.9 220 120 Dining 140 11.0 90 7.4 112 Bed 2 128 10.0 130 10.7 129 Bed 3 9.5 125 MB 18.0 210 CR 330 26.0 450 36.9 410 494 Total 1,268 1,220 100.1 1,350

Zr Balancing by Average CFM 1 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Average CFM Corrected Average CFM CFM & % Design Kitchen 200 15.8 100 8.2 150 GR 11.9 220 125 Dining 140 11.0 90 7.4 115 Bed 2 128 10.0 130 10.7 129 Bed 3 120 9.5 MB 18.0 210 CR 330 26.0 450 36.9 410 390 Total 1,268 1,220 100.1 1,350 1,244 + ÷ 2 =

Zr Balancing by Average CFM 2 1,350 ÷ 1,244 = 1.085 1.085 × Average CFM Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Average CFM Corrected Average CFM CFM & % Design Kitchen 200 15.8 100 8.2 150 GR 11.9 220 125 Dining 140 11.0 90 7.4 115 Bed 2 128 10.0 130 10.7 129 Bed 3 120 9.5 MB 18.0 210 CR 330 26.0 450 36.9 410 390 Total 1,268 1,220 100.1 1,350 1,244

Zr Balancing by Average CFM 3 1,350 ÷ 1,244 = 1.085 1.085 × Average CFM Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Average CFM Corrected Average CFM CFM & % Design Kitchen 200 15.8 100 8.2 150 163 GR 11.9 220 125 136 Dining 140 11.0 90 7.4 115 Bed 2 128 10.0 130 10.7 129 Bed 3 120 9.5 MB 18.0 210 228 CR 330 26.0 450 36.9 410 390 423 Total 1,268 1,220 100.1 1,350 1,244

Zr Balancing by Average CFM 4 1,350 ÷ 1,244 = 1.085 1.085 × Average CFM Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Average CFM Corrected Average CFM CFM & % Design Kitchen 200 15.8 100 8.2 150 163 GR 11.9 220 125 136 Dining 140 11.0 90 7.4 115 Bed 2 128 10.0 130 10.7 129 Bed 3 120 9.5 MB 18.0 210 228 CR 330 26.0 450 36.9 410 390 423 Total 1,268 1,220 100.1 1,350 1,244 1,351

Zr Balancing by Average CFM 5 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Average CFM Corrected Average CFM CFM & % Design Kitchen 200 15.8 100 8.2 150 163 GR 11.9 220 125 136 Dining 140 11.0 90 7.4 115 Bed 2 128 10.0 130 10.7 129 Bed 3 120 9.5 MB 18.0 210 228 CR 330 26.0 450 36.9 410 390 423 Total 1,268 1,220 100.1 1,350 1,244 1,351

Zr Balancing by Average CFM 6 Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Average CFM Corrected Average CFM CFM & % Design Kitchen 200 15.8 100 8.2 150 163 GR 11.9 220 125 136 Dining 140 11.0 90 7.4 115 Bed 2 128 10.0 130 10.7 129 Bed 3 120 9.5 MB 18.0 210 228 CR 330 26.0 450 36.9 410 390 423 Total 1,268 1,220 100.1 1,350 1,244 1,351

Thermostat Location? Room Cooling CFM % Total CFM Heating CFM Test 1 CFM Design CFM Final CFM % of Design Kitchen 200 15.8 100 8.2 150 160 GR 11.9 220 120 Dining 140 11.0 90 7.4 112 Bed 2 128 10.0 130 10.7 129 Bed 3 9.5 125 MB 18.0 210 CR 330 26.0 450 36.9 410 494 Total 1,268 1,220 100.1 1,350

Thermostat Location by C/H Average Room Cooling CFM % Total CFM Heating CFM Design CFM C/H Ratio Stat Location Kitchen 200 15.8 100 8.2 160 2 GR 150 11.9 120 1.5 Dining 140 11.0 90 7.4 112 1.56 Bed 2 128 10.0 130 10.7 129 0.98 Bed 3 9.5 125 0.92 MB 220 18.0 210 0.91 CR 330 26.0 450 36.9 494 0.73 Total/ Average 1,268 1,220 100.1 1,350 8.6/1.23 Great Room: 1.5 – 1.23 = 0.27 Great Room Bed 2: 1.23 – 0.98 = 0.25

Single Zone Systems In our example home there are seven rooms where the thermostat can be placed. Plus or minus 15% of the design airflow in a room can result in a 3OF temperature swing. The worst place to place the thermostat is where the difference between the heating and cooling CFM is the greatest (Kitchen in our example house).

Design CFM For Balancing Once the balance is completed, all documentation should be filled in with the final measured CFM values for each room. If there is a problem room later, those CFM values can be used to make airflow adjustments. Adjusting one or two rooms in the summer without considering what that will do in the winter will result in messing up the system’s balance.

Field Notes Sometimes the homeowners complaint is, “it is always too warm in this room.” If that is the case, there is probably too much airflow during the heating mode and not enough airflow during the cooling mode. In some rooms with very high differences between heating and cooling CFM, the room’s balancing damper can be marked with settings for heating and cooling. Note: those settings for one room could be automated with a single zone damper set with maximum and minimum opening positions (all other rooms need to be tested to make sure they remain proportional for both settings.