Thoracic aortic lesions treated with the Zenith TX1 and TX2 thoracic devices: Intermediate- and long-term outcomes  Jose P. Morales, MD, Roy K. Greenberg,

Slides:



Advertisements
Similar presentations
Endoleak after endovascular aneurysm repair: Duplex ultrasound imaging is better than computed tomography at determining the need for intervention  Greg.
Advertisements

Christopher K. Zarins, MD, Rodney A. White, MD, Thomas J. Fogarty, MD 
Open Distal Fenestration of Chronic Dissection Facilitates Endovascular Elephant Trunk Completion: Late Outcomes  Muhammad Aftab, MD, Jay J. Idrees, MD,
Patients with chronic obstructive pulmonary disease have shorter survival but superior endovascular outcomes after endovascular aneurysm repair  Moqueet.
Acute blunt traumatic injury to the descending thoracic aorta
Revised duplex criteria and outcomes for renal stents and stent grafts following endovascular repair of juxtarenal and thoracoabdominal aneurysms  Walid.
Elisabeth Schwierz, MD, Ralf R
Surgeon-modified fenestrated-branched stent grafts to treat emergently ruptured and symptomatic complex aortic aneurysms in high-risk patients  Joseph.
Endovascular repair of thoracic aortic lesions with the Zenith TX1 and TX2 thoracic grafts: Intermediate-term results  Roy K. Greenberg, MD, Sean O’Neill,
Karan Garg, MD, Caron B. Rockman, MD, Billy J. Kim, MD, Glenn R
Arch and visceral/renal debranching combined with endovascular repair for thoracic and thoracoabdominal aortic aneurysms  Sung Wan Ham, MD, Terry Chong,
An evaluation of centerline of flow measurement techniques to assess migration after thoracic endovascular aneurysm repair  Sean O’Neill, MD, Roy K. Greenberg,
Supra-aortic vessels aneurysms: Diagnosis and prompt intervention
Efficacy and durability of endovascular thoracoabdominal aortic aneurysm repair using the caudally directed cuff technique  Linda M. Reilly, MD, Joseph.
Adrian O'Callaghan, MB, Tara M. Mastracci, MD, Roy K
Late conversion of aortic stent grafts
John W. Fehrenbacher, MD, Robert A. McCready, MD 
Endoleak after endovascular aneurysm repair: Duplex ultrasound imaging is better than computed tomography at determining the need for intervention  Greg.
Results of the United States multicenter prospective study evaluating the Zenith fenestrated endovascular graft for treatment of juxtarenal abdominal.
Bruce A. Perler, MD, MBA  Journal of Vascular Surgery 
Melanie K. Rose, MD, Benjamin J. Pearce, MD, Thomas C
Fourteen-year outcomes of abdominal aortic endovascular repair with the Zenith stent graft  Fabio Verzini, MD, PhD, FEBVS, Lydia Romano, MD, Gianbattista.
What is the clinical utility of a 6-month computed tomography in the follow-up of endovascular aneurysm repair patients?  Michael R. Go, MD, Joel E. Barbato,
Therapeutic management of superior mesenteric artery aneurysms
Thoracic endovascular aortic repair of aortobronchial fistulas
Efficacy of thoracic endovascular stent repair for chronic type B aortic dissection with aneurysmal degeneration  Salvatore T. Scali, MD, Robert J. Feezor,
Endovascular repair of thoracic stent-graft bulging rupture in a patient with multiple thoracic aneurysms due to Takayasu disease  Guido Regina, MD, Alessandro.
Patients with chronic obstructive pulmonary disease have shorter survival but superior endovascular outcomes after endovascular aneurysm repair  Moqueet.
The results of stent graft versus medication therapy for chronic type B dissection  Xin Jia, MD, Wei Guo, MD, Tian-xiao Li, MD, Sheng Guan, MD, Rui-min.
Comparison of attachment site endoleak rates in Dacron versus native aorta landing zones after thoracic endovascular aortic repair  Asvin M. Ganapathi,
Follow-up outcomes of hybrid procedures for thoracoabdominal aortic pathologies with special focus on graft patency and late mortality  Claudio Bianchini.
Fenestrated and branched endovascular aneurysm repair outcomes for type II and III thoracoabdominal aortic aneurysms  Matthew J. Eagleton, MD, Matthew.
Staged hybrid approach using proximal thoracic endovascular aneurysm repair and distal open repair for the treatment of extensive thoracoabdominal aortic.
Efficacy and durability of the chimney graft technique in urgent and complex thoracic endovascular aortic repair  Adel Bin Jabr, MD, Bengt Lindblad, MD,
Type II endoleak prevention with coil embolization during endovascular aneurysm repair in high-risk patients  Dominique Fabre, MD, Elie Fadel, PhD, Philippe.
Endovascular repair of an iliac artery aneurysm in a patient with Ehlers-Danlos syndrome type IV  Britt H. Tonnessen, MD, W. Charles Sternbergh, MD, Krishna.
Nature, frequency, and predictors of secondary procedures after endovascular repair of abdominal aortic aneurysm  Ellis S.K. Sampram, MDa, Matthew T.
Elisabeth Schwierz, MD, Ralf R
Defining high risk in endovascular aneurysm repair
Zenith abdominal aortic aneurysm endovascular graft
Stent graft migration after endovascular aneurysm repair: importance of proximal fixation  Christopher K Zarins, MD, Daniel A Bloch, PhD, Tami Crabtree,
Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture  Bart E. Muhs, MD,
Kenneth Ouriel, MD, Daniel G. Clair, MD, K
Endovascular repair of lesions involving the descending thoracic aorta
Outcomes of endovascular aneurysm repair with selective internal iliac artery coverage without coil embolization  Konstantinos O. Papazoglou, MD, PhD,
Surgical versus endovascular treatment of traumatic thoracic aortic rupture  Philippe Amabile, MD, Frédéric Collart, MD, Vlad Gariboldi, MD, Gilles Rollet,
Mid- and long-term device migration after endovascular abdominal aortic aneurysm repair: A comparison of AneuRx and Zenith endografts  Britt H. Tonnessen,
Jon S. Matsumura, MD, Germano Melissano, MD, Richard P
Coil embolization of persistent false lumen after stent graft repair of type B aortic dissection  Enrique María San Norberto, MD, Vicente Manuel Gutiérrez,
Redefining postoperative surveillance after endovascular aneurysm repair: Recommendations based on 5-year follow-up in the US Zenith multicenter trial 
Thoraflex Hybrid Endovascular Frozen Elephant Trunk Device for Treatment of Complex Aortic Arch Disease  John H. Landau, Luc A. Dubois, Adam H. Power,
Evaluation of the Endurant stent graft under instructions for use vs off-label conditions for endovascular aortic aneurysm repair  Giovanni Torsello,
Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial  Christopher K. Zarins, MDa, Rodney A. White,
Fenestrated and branched endovascular aortic repair for chronic type B aortic dissection with thoracoabdominal aneurysms  Atsushi Kitagawa, MD, Roy K.
David H. Stone, MD, David C. Brewster, MD, Christopher J
Scott A. LeMaire, MD, Susan Y
Pan-aortic hybrid treatment of mega-aorta syndrome
Supra-aortic hybrid endovascular procedures for complex thoracic aortic disease: Single center early to midterm results  Yiu Che Chan, BSc MB, BS, MD,
Jocelyn M. Beach, MD, Yuki Kuramochi, RN, BSN, Corey Brier, MA, Eric E
Double-Barreled Cannon Stent Grafts: Possible Solution for Extremely Dilated Landing Zone of Aorta  Yi-Hsuan Wu, MD, Cheng-Che Tseng, MD, Tzong-Nan Kuo,
Revised duplex criteria and outcomes for renal stents and stent grafts following endovascular repair of juxtarenal and thoracoabdominal aneurysms  Walid.
Long-term dilatation of polyester and expanded polytetrafluoroethylene tube grafts after open repair of infrarenal abdominal aortic aneurysms  Peter L.
Outcomes of fenestrated endovascular repair of juxtarenal aortic aneurysm  Thorarinn Kristmundsson, MD, PhD, Björn Sonesson, MD, PhD, Nuno Dias, MD, PhD,
Isolated blunt abdominal aortic injury without concomitant abdominal injuries treated with endovascular stent grafting  Monica N. Khattak, Eric V. Olivero,
Endovascular treatment of thoracoabdominal aortic aneurysms
John F. Bilello, MD, FACS, Peter L
Repair of juxtarenal para-anastomotic aortic aneurysms after previous open repair with fenestrated and branched endovascular stent grafts  Donald J. Adam,
One-year outcomes from the international multicenter study of the Zenith Alpha Thoracic Endovascular Graft for thoracic endovascular repair  Karl A. Illig,
Michael P. Jenkins, MD, Stéphan Haulon, MD, PhD, Roy K
Staged Hybrid Repair of Combined Ascending/Descending Thoracic Aortic Aneurysms Using the Frozen Elephant Trunk Technique With the Cook Zenith Tx2 Stent.
Presentation transcript:

Thoracic aortic lesions treated with the Zenith TX1 and TX2 thoracic devices: Intermediate- and long-term outcomes  Jose P. Morales, MD, Roy K. Greenberg, MD, Catherine A. Morales, BS, Marcelo Cury, MD, Adrian V. Hernandez, MD, PhD, Sean P. Lyden, MD, Daniel Clair, MD  Journal of Vascular Surgery  Volume 48, Issue 1, Pages 54-63 (July 2008) DOI: 10.1016/j.jvs.2008.02.028 Copyright © 2008 The Society for Vascular Surgery Terms and Conditions

Fig 1 Overall mortality (thick line) and aneurysm-related morality (thin line) were assessed using a Kaplan-Meier analysis, and the error bars denote the 95% confidence intervals (CI). Journal of Vascular Surgery 2008 48, 54-63DOI: (10.1016/j.jvs.2008.02.028) Copyright © 2008 The Society for Vascular Surgery Terms and Conditions

Fig 2 Freedom from secondary intervention is shown in 160 patients with >72 months of follow-up. Journal of Vascular Surgery 2008 48, 54-63DOI: (10.1016/j.jvs.2008.02.028) Copyright © 2008 The Society for Vascular Surgery Terms and Conditions

Fig 3 A, Kaplan-Meier life-table analysis shows of freedom from primary endoleak and (B) secondary endoleaks. Journal of Vascular Surgery 2008 48, 54-63DOI: (10.1016/j.jvs.2008.02.028) Copyright © 2008 The Society for Vascular Surgery Terms and Conditions

Fig 4 A, A three-dimensional (3D) reconstruction of a computed tomography (CT) scan demonstrates an endovascular completion of an elephant trunk graft. The pacer wire attached near the distal end of the elephant trunk graft is indicated by the small arrow. Distally, the device was deployed into an aneurysmal segment that had been wrapped with a polyester strip to create a landing zone in a patient deemed unable to tolerate an open thoracoabdominal repair (large arrow). B, Same patient, 3D reconstruction CT scan at the 6-month follow-up demonstrates a stable proximal dense position (arrow) enlargement of the wrapped segment, distal endoleak, and proximal migration (circle) of the distal stent through the wrap and into the aneurysm. Note, no barbs were used on the distal fixation system for fear of injury to the abnormal aorta below the level of the stent graft. C, Magnified view of previous image demonstrates scratches on the external aortic wall (arrows) caused by migration of the device. Journal of Vascular Surgery 2008 48, 54-63DOI: (10.1016/j.jvs.2008.02.028) Copyright © 2008 The Society for Vascular Surgery Terms and Conditions

Fig 5 A and B, Radiographs in different projections demonstrate a single barb fracture (circle and arrow) first noticed at 2 years follow up. Journal of Vascular Surgery 2008 48, 54-63DOI: (10.1016/j.jvs.2008.02.028) Copyright © 2008 The Society for Vascular Surgery Terms and Conditions