Calibration Techniques

Slides:



Advertisements
Similar presentations
University of San Francisco Chemistry 260: Analytical Chemistry
Advertisements

Measurements and Their Uncertainty 3.1
The basics for simulations
Quantitative Gas Chromatography
Instrumental Analysis
Statistics Review – Part I
CHEM 213 Instrumental Analysis Lab Lecture – Copper by AA & Least Squares Analysis.
Calibration methods Chemistry 243.
Spectrophotometric Determination of Iron Using 1,10-Phenanthroline
Lial/Hungerford/Holcomb/Mullins: Mathematics with Applications 11e Finite Mathematics with Applications 11e Copyright ©2015 Pearson Education, Inc. All.
Simple Linear Regression Analysis
Multiple Regression and Model Building
Chapter 15 Acid-Base Titrations & pH
Commonly Used Distributions
1 Density Calculations In this section, you will learn how to find the molarity of solution from two pieces of information (density and percentage). Usually.
Determination of Concentration Using Spectrophotometry
CHEMISTRY ANALYTICAL CHEMISTRY Fall
Result validation. Exercise 1 You’ve done an analysis to the best of your ability using the correct procedure. Is your answer correct? possibly, hopefully.
Calibration Methods Introduction
Chapter 1 Introduction Analytical Chemistry deals with methods for determining the chemical composition of samples. Qualitative Analysis (identification)
Chemical Analysis Qualitative Analysis Quantitative Analysis Determination “Analyze” a paint sample for lead “Determine” lead in a paint sample.
ANALYTICAL CHEMISTRY ERT 207
Summary 1 l The Analytical Problem l Data Handling.
Basic Questions Regarding All Analytical & Instrumental Methods (p 17-18) What accuracy and precision are required? How much sample do I have available,
Determining the k a of an acid- base indicator Experiment 3.
Data Handling l Classification of Errors v Systematic v Random.
Analytical Chemistry Definition: the science of extraction, identification, and quantitation of an unknown sample. Example Applications: Human Genome Project.
CALIBRATION METHODS.
Chemometrics Method comparison
Method Comparison A method comparison is done when: A lab is considering performing an assay they have not performed previously or Performing an assay.
Quality Control In Measurements Tom Colella CLAS Goldwater Environmental Lab.
Instrumental Analysis
Data Analysis and Presentation
Chapter1 Introduction.
Handling Data and Figures of Merit Data comes in different formats time Histograms Lists But…. Can contain the same information about quality What is meant.
SPECTROPHOTOMETRY. Determines concentration of a substance in solution by Measures light absorbed by solution at a specific wavelength by using spectrophotometer.
Data Analysis and Presentation Chapter 5- Calibration Methods and Quality Assurance EXCEL – How To Do 1- least squares and linear calibration curve/function.
Quality Assurance How do you know your results are correct? How confident are you?
Acid/Base Titration Buffers. Buffers A mixture composed of a weak acid and its conjugate base (acidic buffer) OR weak base and its conjugate acid (basic.
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
CALIBRATION METHODS. For many analytical techniques, we need to evaluate the response of the unknown sample against the responses of a set of standards.
Data Analysis: Quantitative Statements about Instrument and Method Performance.
Data Analysis and Presentation Chapter 5- Calibration Methods and Quality Assurance EXCEL – How To Do 1- least squares and linear calibration curve/function.
Instrumental Methods: Intro
CHEM 213 Instrumental Analysis Lab Lecture – Fluorescence and Calculations.
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Determination of Concentration Using Spectrophotometry
Interferences. Matrix interference the matrix is the major component of the sample can affect the measured analyte response Response = constant x concentration.
Chapter 1: Introduction Analytical Chemistry Analytical Chemistry Qualitative analysis Qualitative analysis Quantitative analysis Quantitative analysis.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
8. Internal standards Adv. Chromatography. Instrument variations problems caused by instrument or sample introduction: standard addition or matrix-matched.
Instrumental Analysis
Chapter 5 Quality Assurance and
Solution Concentration.  Lesson Objectives  Describe the concept of concentration as it applies to solutions, and explain how concentration can be increased.
Art PowerPoints Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS.
The standard deviation (SD) quantifies variability
Applications of UV-Vis Spectroscopy
Quantitative Gas Chromatography
Instrumental Methods: Intro
iCAP OES Analysis of Trace Elements in Hair
Analysis of Iron Experiments 3, 19 & 20.
COLORED SOLUTIONS A solution will appear a certain color if it absorbs its complementary color from the color wheel EX2-1 (of 24)
Absorption Spectroscopy
Statistical Methods For Engineers
Chapter 5 Quality Assurance and Calibration Methods
Determination of Mn in Steel (Standard Addition)
Cu2+ + 4NH3 → Cu(NH3)42+ (deep blue)
DETERMINATION OF GLUCOSE IN BLOOD STREAM
Determination of Mn in Steel (Standard Addition)
Spectrophotometry A method to determine concentration of a species exploiting the absorption of EMR.
Presentation transcript:

Calibration Techniques 1. Calibration Curve Method 2. Standard Additions Method 3. Internal Standard Method

Calibration Curve Method Most convenient when a large number of similar samples are to be analyzed. Most common technique. Facilitates calculation of Figures of Merit.

Calibration Curve Procedure Prepare a series of standard solutions (analyte solutions with known concentrations). Plot [analyte] vs. Analytical Signal. Use signal for unknown to find [analyte].

Example: Pb in Blood by GFAAS Signal (ppb) (mAbs)   0.50 3.76 1.50 9.16 2.50 15.03 3.50 20.42 4.50 25.33 5.50 31.87 Results of linear regression: S = mC + b m = 5.56 mAbs/ppb b = 0.93 mAbs

C = (27.5 mAbs – 0.92 mAbs) / 5.56 mAbs / ppb (3 significant figures) A sample containing an unknown amount of Pb gives a signal of 27.5 mAbs. Calculate the Pb concentration. S = mC + b C = (S - b) / m C = (27.5 mAbs – 0.92 mAbs) / 5.56 mAbs / ppb C = 4.78 ppb (3 significant figures)

Calculate the LOD for Pb 20 blank measurements gives an average signal 0.92 mAbs with a standard deviation of σbl = 0.36 mAbs LOD = 3 σbl/m = 3 x 0.36 mAbs / 5.56 mAbs/ppb LOD = 0.2 ppb (1 significant figure)

(include this point on the calibration curve) Find the LDR for Pb Lower end = LOD = 0.2 ppb (include this point on the calibration curve) SLOD = 5.56 x 0.2 + 0.93 = 2.0 mAbs (0.2 ppb , 2.0 mAbs)

This is approximately 5% below the expected value of 103.71 mAbs Find the LDR for Pb Upper end = collect points beyond the linear region and estimate the 95% point. Suppose a standard containing 18.5 ppb gives rise to s signal of 98.52 mAbs This is approximately 5% below the expected value of 103.71 mAbs (18.50 ppb , 98.52 mAbs)

Find the LDR for Pb LDR = 0.2 ppb to 18.50 ppb or LDR = log(18.5) – log(0.2) = 1.97 2.0 orders of magnitude 2.0 decades

Calculate the slope of the log-log plot Find the Linearity Calculate the slope of the log-log plot

Not Linear??

Not Linear??

log(S) = log(m) + log(C) Remember S = mC + b log(S) = log (mC + b) b must be ZERO!! log(S) = log(m) + log(C) The original curve did not pass through the origin. We must subtract the blank signal from each point.

Corrected Data

Linear!

Standard Addition Method Most convenient when a small number of samples are to be analyzed. Useful when the analyte is present in a complicated matrix and no ideal blank is available.

Standard Addition Procedure Add one or more increments of a standard solution to sample aliquots of the same size. Each mixture is then diluted to the same volume. Prepare a plot of Analytical Signal versus: volume of standard solution added, or concentration of analyte added.

Standard Addition Procedure The x-intercept of the standard addition plot corresponds to the amount of analyte that must have been present in the sample (after accounting for dilution). The standard addition method assumes: the curve is linear over the concentration range the y-intercept of a calibration curve would be 0

Example: Fe in Drinking Water The concentration of the Fe standard solution is 11.1 ppm All solutions are diluted to a final volume of 50 mL

-6.08 mL

Vsam x [Fe]sam = Vstd x [Fe]std x-intercept = -6.08 mL Therefore, 10 mL of sample diluted to 50 mL would give a signal equivalent to 6.08 mL of standard diluted to 50 mL. Vsam x [Fe]sam = Vstd x [Fe]std 10.0 mL x [Fe] = 6.08 mL x 11.1 ppm [Fe] = 6.75 ppm

Internal Standard Method Most convenient when variations in analytical sample size, position, or matrix limit the precision of a technique. May correct for certain types of noise.

Internal Standard Procedure Prepare a set of standard solutions for analyte (A) as with the calibration curve method, but add a constant amount of a second species (B) to each solution. Prepare a plot of SA/SB versus [A].

Notes The resulting measurement will be independent of sample size and position. Species A & B must not produce signals that interfere with each other. Usually they are separated by wavelength or time.

Example: Pb by ICP Emission Each Pb solution contains 100 ppm Cu.

No Internal Standard Correction

Internal Standard Correction

Results for an unknown sample after adding 100 ppm Cu