New TGA-IR Module.

Slides:



Advertisements
Similar presentations
The YL2000 FTIR.
Advertisements

OU’s 454 reagent cooling system To extend the life of the GS20 reagents for longer than 42 flows, we found it necessary to develop an apparatus for reagent.
Meat evaluation There are some important parameters such as temperature, acidity (pH), water activity (aw) and cooking loss. Other physical parameters.
Drug Delivery & Tissue Engineering Laboratory
CAVIAR water vapour laboratory FTS measurements Dr Robert McPheat CAVIAR Meeting Cosners’ House, 15/12/2009.
Progress in water vapour spectroscopy at RAL Dr Robert McPheat CAVIAR Progress Meeting Cosners’ House, 14/12/2009.
Terry A. Ring Chemical Engineering University of Utah
1 VACUUM ATMOSPHERES Co NEW PRODUCT ANNOUNCEMENT November 28, 2001.
Progress in water vapour spectroscopy at RAL Dr Robert McPheat CAVIAR Progress Meeting University of Leicester, 24/09/2009.
AT-LINE A Practical Application of Smart Modular Sampling Components IFPAC 2001 ABB.
HUMIDITY. ABSOLUTE HUMIDITY: Absolute humidity (expressed as grams of water vapor per cubic meter volume of air) is a measure of the actual amount of.
Matt Robinson Thomas Tolman.  Describes Convective Heat Transfer  Needed for all external and internal flow situations.
:57 Bruker Barcode Label Types Introduction This SOP describes the software „Bruker Barcode Label Designer“ and the barcode labels for different.
…an innovative shell and tube heat exchanger with an exceptionally high heat transfer coefficient for industrial fluid cooling and air conditioning.
Biochemical instrumental analysis-2
#1Graduated Cylinder Measures VOLUME - fluids mL, L SI Base Unit for volume: L.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
W. EbensteinDOE Review Duke UniversitySeptember 1999 TRT Barrel Cooling: Electronics  Motivation: u Overheating of electronics causes premature failure.
Why the boy takes his hand away from the kettle? Why the boy takes his hand away from the kettle? Why the boy feels the heat of the kettle? Why the boy.
Microscope magnify objects. Microscope slide Glass slide to prepare a slide slip cover to cover specimen on slide slide Slip cover.
Lab Tools are WAY COOL!!! RULES: Lab tools are NOT toys! Wash them, dry them, and put them back in their place after every lab. Report breakage to the.
Energy Transfer.  One of the simplest ways energy is transferred is as heat.  Though energy has many different forms, all energy is measured in units.
Peter Spiller, COLMAT-Kick off meeting, Cryo-Collimator, CERN, COLMAT Kick-off meeting CERN Peter Spiller Cryo-Collimator (Catcher) for.
Vocabulary Test. 1. A measure of the force of gravity on an object. A. Mass B. Weight C. Volume D. Length.
The basics of in-situ Electrochemcial FTIR spectroscopy
Matter states and its changes
FVTX Review, November 17th, FVTX Mechanical Status: WBS 1.6 Walter Sondheim - LANL Mechanical Project Engineer; VTX & FVTX.
Lindab | we simplify construction - Flexibility when it is needed... Premum & Premax With unique JetCone and Angled Nozzles Patent pending solution.
Measuring Measuring Length, Mass, and Volume. How long is the following? Ans. 7.7 cm.
Multiple Module Vacuum Oven Productivity Enhancement System.
Reaction Monitoring with ReactionView ® and ReactionProbe™ In-situ contamination and surface analysis with SpotView and SpotView-SL © Remspec Corp
Matter-ial Jeopardy! Matter-ial Jeopardy! Matt- Props V, T and P Elemental Mastery The Metric Slide Don’t be Dense
Hiden HPR-20 QIC EGA for evolved gas analysis in TGA-MS.
8/29/07K. C. Wu - Brookhaven National Lab1 Major Components in ILC IR Hall Interchangeable Detectors.
CW Cryomodules for Project X Yuriy Orlov, Tom Nicol, and Tom Peterson Cryomodules for Project X, 14 June 2013Page 1.
Warm up: List 5 safety rules you must follow while conducting a lab experiment.
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 11 Heat Exchangers.
Target Systems and Monolith Design Update Rikard Linander Group Leader Monolith and Handling April 2, 2014.
MATTER REVIEW. 1. Define the following Matter –anything that has mass and takes up space Evaporation- slow change from liquid to gas Boiling Point- the.
Identification of Substances by Physical Properties.
Linescanner MP150 Infrared Temperature Measurement for Quality Control and Process Automation Raytek Confidential 10/2010, Rev. B.
LAB. S4 Identification of Drugs Using Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FT-IR Spectroscopy)
Thermal Analysis.
What’s the MATTER!?!.
Lab Safety, Lab Equipment, & Measurement Quiz Review
MAE 5310: COMBUSTION FUNDAMENTALS
Ch. 9 Heat and States of Matter!
Energy Transformations
LEYARD TWS SERIES LED VIDEO WALL DISPLAYS
Opti-Purge® FAST INFLATION PURGE SYSTEM
LEYARD® TWA SERIES LED VIDEO WALLS
Lab Equipment.
Small Coolers for MICE MICE Collaboration Meeting RAL Michael A. Green
Science 8 Welcome Back!!!.
Chapter 8 : Natural Convection
Apologia Chemistry Thermochemistry Module 2 Energy, Heat, Temperature.
Concentric Tube (double-pipe) Heat Exchangers
Cryogenic cavern in Asian site
Science Equipment and measuring
Solutions to the Mass, Volume Density Problems.
Heat Exchangers Heat Exchangers.
Jeopardy whats the matter?.
Heat Transfer from Extended Surfaces (Fins)
Primary Spectrometer & Sample Environment
Chp Phase Changes Pg
11.2 State of the Atmosphere
Introduction to the NGC Chromatographic System
Ch The Nature of Liquids
What amount of heat is required to increase the temperature of 75
NanoSource Evaporation system with flow control APPLICATIONS
Presentation transcript:

New TGA-IR Module

Key Highlights and Improvements Extended Temperature Range Improved Transfer Line Improved Flow Characteristics More Rugged Cell Design Eliminated Purge Tubes Look More Consistent with iS10 and iS50 Switchable 110V/220V – No External Transformer

Gas Cell Operate routinely at 300º C Less chance of sample condensing in cell Rugged Nickel Plated Aluminum Construction Eliminates fragile glass connections Similar to 6700 External Design Optimized to fit the IR beam >80% Throughput – Nicolet iS10 and iS50 – KBr Windows

Gas Cell Lower Cell Volume 22 ml vs. 49 ml Less dead-volume and mixing in cell Superior Flow Characteristics Improved Gram-Schmidt Peak Shapes Choice of KBr or ZnSe Windows Permanently Aligned No realignment needed after cleaning

Example of Less Dead-Volume and Mixing in Cell

Weight Loss Data and Gram-Schmidt – New Cell Calcium Oxalate

Extended Temperature Range/Transfer Line 300º C Transfer Line and Cell Even Heating in Transfer Line No cold spots Less chance of material condensing and transfer line clogging Cool External Transfer Line Surface Meets regulatory standards Available in 5’ (152 cm) or 8’ (244 cm) lengths (recommend 5’ for most installations)

Purge Slides Directs moisture away from sample compartment windows during initial heating of interface

Compared to competitors Mercury TGA Greatly simplifies the analysis of complex data Saves time Integrated Dual Temperature Controllers Pike External Box Single Controller Perkin Elmer Bruker

New Specification Sheet

Configuration Available for the Nicolet 380, 6700/8700/AEM, iS10/IZ10 and iS50 Select a Module with or without software, a cell and a transfer line TGA-IR MODULE Must Select One 840-253900 Nicolet TGA-IR Module 840-254200 Nicolet TGA-IR Module with OMNIC Series Software 840-254500 Nicolet TGA-IR Module with OMNIC Series and Vapor Library TGA-IR Module Gas Cell 840-257500 TGA-IR Module Gas Cell with KBr Windows 840-257600 TGA-IR Module Gas Cell with ZnSe Windows Heated Transfer Line 840-253600 5' (127 mm) Heated Transfer Line 840-253700 8' (203 mm) Heated Transfer Line

TGA-IR Module Interfaced to TA Instruments TGA