CLINICAL MODIFICATION IN ROOT CORRECTION PHASE IN SEGMENTED ARCH TECHNIQUE World J Orthod 2006; 7: 59-64 Daniel Ianni Filho, DDS, MS Klaus Fernando Cardoso.

Slides:



Advertisements
Similar presentations
Rests & Rest Seats.
Advertisements

RESTS AND REST SEATS. RESTS AND REST SEATS The Component Parts of Removable Partial Dentures Denture Base Artificial Teeth Supporting Rests Connectors:
FIXED ORTHODONTIC APPLIANCES DENT 657. Removable vs. Fixed Appliances REMOVABLE n Tipping only n No control over root movement n Pts co-operation n Hygienic.
Welcome. In navigating through the slides, you should click on the left mouse button when (1), you see the mouse holding an x-ray tubehead (see below),
Dr. Hoori Mir Mohammad Sadeghi
Movements Universal tooth movements are achieved. High forces are delivered. Tooth movement is slow. Movement of anchor teeth as well as that of teeth.
牙列拥挤的治疗 Treatment of Crowed Teeth
Prosthodontics and Occulsion
Dental Anatomy & Occlusion Dent 202
Arrangement of teeth Prof.Dr. Ahlam El-Sharkawy
UPPER REMOVABLE APPLIANCE (URA)
1 HEAD GEAR DR. ABDUL JABBAR. 2 Means of applying posterior directed forces to teeth and skeletal structures from an extra oral source.
8.6 Frictional Forces on Collar Bearings, Pivot Bearings and Disks
Bitewing radiography.
Intrusion of Incisors to Facilitate Restoration: The Impact on the Periodontium Intrusion of Incisors to Facilitate Restoration: The Impact on the Periodontium.
FIXED APPLIANCE Prepared by Prepared by Dr. Hana Omar AL. Balbeesi Dr. Hana Omar AL. Balbeesi Orthodontic consultant Orthodontic consultant.
Mechanical Principles in Orthodontic Force Control
Critical Appraisal of in Vitro Steady- State Frictional Resistance Studies Samuel J. Burrow III Seminar in orthodontic 2010; 16:
TYPES OF ORTHODONTIC APPLIANCES
Dr. Hoori Mir Mohammad Sadeghi
SERIAL EXTRACTION.
OCCLUSAL EXPOSURE TECHNIQUES. At times, more extensive radiographic views of oral tissues are desired than are obtainable with periapical or bite-wing.
In the name of GOD Biomechanic and types of tooth movement Presented by: Dr Somayeh Heidari Orthodontist.
Arrangement of artificial teeth in abnormal jaw relations Maxillary protrusion and wider upper arch Dr.Mohammad Al Sayed 25/3/2008.
ARCHWIRE SEQUENCE DAMON SYSTEM EUROPEAN DAMON MASTER
CLOSURE OF A DIASTEMA IN THE ESTHETIC ZONE WITH PORCELAIN VENEERS PART II OF THE SMILBYDESIGNNY SERIES BY SMILEBYDESIGNNY.COM.
Tooth Identification.
URA Components Marshitah Abd Wahid Mohd Azizul Bin Mohd Atan
Marshitah ,Sakinah,Syafiqah, Hamzi,Azizul ,Fais , Asmat,Fatin ,Fadhila
Andrew’s Six Keys & Skeletal Pattern
RETENTION PRE-TREATMENT POST-TREATMENT RELAPSE UNPREDICTABLE.
S G D O R T H O D O N T I C: BIONATOR, ELSAA, ACCO
Arrangement of the posterior teeth
Case 8.6 (1-7) A 55-year-old woman who had previously been using a partial removable denture. During a long hospitalization, the denture had not been used.
In the name of GOD. In the name of GOD Anchorage and its control Presented by: Dr Somayeh Heidari Orthodontist.
Arrangement Of The Anterior Teeth
Indirect Retainers Rola M. Shadid, BDS, MSc.
Relapse and Retention.
European 160 Journal of Paediatric Dentistry vol. 14/ Group 3-Aishah,Amalina, Anis, Asmat, Fadhila, Fatimah, Hamzi, Laila, Ruhaizan,Zahid.
بسم الله الرحمن الرحيم.
Hawley’s retainer & other URA. Function of URA Arch development Arch length development Retainer.
Case 7.6 (1-12) A 53-year-old woman with a nightmare of losing her upper front teeth came for a visit: the patient was not regularly followed by a dentist.
EVALUATION AND SELECTION OF ABUTMENTS
Biological Principle Of Orthodontic Tooth Movements
CLASS II DIVISION II 48 YEAR OLD FEMALE At 1 month and 11 days the lower was bonded and the VECTOR III® Interactive Springs were adjusted. VECTOR III®
Morphological norm of permanent dentition - occlusion Prof. dr hab. n. med. Teresa Matthews-Brzozowska.
Case 8.5 Patient who had lost the left lower first molar due to caries years earlier. (1-3) Extraoral image before treatment. (4-8) Occlusal at start of.
CD # 1. Introduction. In order to overcome the limitation of free teeth movement which was restricted by the Edgewise Arch Technique, Dr. Begg started.
DUO-TEE® SPRINGS VECTOR III®
تقويم \ خامس اسنان د. منار م(3-4) 4\ 5\ 2017 Adult orthodontics.
Articulators Dr .shanai M..
CROWN PREPERATION معالجة اسنان \ الخامس د. طلال السلمان م(1+2)
Classification of Orthodontic Malocclusion
Occlusal Schemes.
Orthodontic appliances removable appliance
ANCHORAGE Dr.Enas Talb.
The importance of incisor positioning in the esthetic smile: The smile arc  David M. Sarver, DMD, MS  American Journal of Orthodontics and Dentofacial.
Exodontia Extraction forceps
Biomechanics of Mini-Implant Placed in the Palate
Andrew’s Six Keys The six keys to normal occlusion, serve as a goal
Dr. Bushra Rashid Noaman
Components of Removable Appliances
Development of occlusion
VECTOR III® PRESENTING BIO\ANALYTIC™ MECHANICS + VECTORLOY™ WIRE =
Rests & Rest Seats.
Cyclic loading (vibration) accelerates tooth movement in orthodontic patients: A double- blind, randomized controlled trial  Dubravko Pavlin, Ravikumar.
Pre adjusted Edgewise Begg
Presentation transcript:

CLINICAL MODIFICATION IN ROOT CORRECTION PHASE IN SEGMENTED ARCH TECHNIQUE World J Orthod 2006; 7: Daniel Ianni Filho, DDS, MS Klaus Fernando Cardoso Bernardo, DDS Adriana Prad Calheta DDS Eduardo Serpa Vieira, DDS

Shape driven versus force driven mechanic Force-driven mechanics, which have a statically determinate force system. With a statically determinate force system, the entire force system can be calculated by the use of the principles of statics or equilibrium. You know precisely the amount of force you apply on each unit, his sense and direction as a resulte you can predict how each element will move. To be able to do this you must work with a limited number of unit. Idealy two

Shape driven versus force driven mechanic The defect are: It is technique dependent There is no fail safe. If the wire is deformed by the occlusal force unwanted tooth movement will occure without limitation It also is more voluminous in the buccal cavity In this case the lingual arch was broken, the patient did not came to fix it. As a result there was a rotation of the posterior unit. In continuous archwire technique the wire would have limited this mouvement.

Shape driven versus force driven mechanic Shape-driven mechanics, which have a statically indeterminate force system. With a statically indeterminate force system, the ent ire force system cannot be easily calculated because of interaction between the forcesystems developed at the active or reactive unit. You use a serie of shape and fixe the teeth to it. The teeth will adapte themself to the new shape

Shaped driven versus force driven mechanic The defect are : If you know what the shape is you do not know were it will be. You cannot know or control the intensity and direction of the force exert on each tooth In this case we want to intrude the upper incisor for to correct the deep bite. The teeth adapt to the shape but by an extrusion of the lateral, not an intrusion of the central

Shape driven versus force driven mechanic

The segmented mechanic principle and rational The mechanics of the segmented arch technique. Angle Orthod 1966; 36: Burstone CJ Rationale of the segmented approach to orthodontic treatment Am J Orthod Dentofac orthop 1995;108:1-8 Stanley Braun, DDS, MME, and Michael R. Marcotte, DDS, MSD

The segmented mechanic principle An orthodontist should have control over the following parameter -The moment to force ratio -The magnitude of the moment or force -The constancy of the force A well-designed appliance should offer -Delivers constant moment to force over a long range of activation -The center of rotation of an active unite should be predictable -The force system at the reactive unit should be know and predictable PREDICTABILITY AND CONTROL

The segmented mechanic principle mechanical advantage predictability With a straight wire the force system is easily predictable with two element. However when the wire is engage in the full arch, it is not possible to know the force system anymore. In certain often encounter situation it can be partially predicted by experience. Determine force system Undetermine force system For example in the extraction case with mesially incline canine, experience tell us that the canine will be tip mesially and that this movement can be suppress by using a ligature wire. But it is not possible to know that only by looking to the teeth

The segmented mechanic principle mechanical advantage predictability In the segmental technic usually no more than three element interact with each other. One basic principle is to limit the number of elements

The segmented mechanic principle mechanical advantage range of force Because the unit are larger the distance between the point of application of two force will also be longer. This as two very important consequence 1 The range is more important 2 A wider range of force is possible

The segmented mechanic principle mechanical advantage range of force The deflection range will be longer, so activation have to be less frequent. Because of the segmental design only one segment need to be change and not the whole arch. Because the deflection range is more important the direction of range is more important the direction of the force is more constant. For example for a cantilever during 2 mm of intrusion There is a variation of the angulation of the force of 11° with a length of 10 mm There is a variation of 22° when the length of the arm is 5°

The segmented mechanic principle mechanical advantage range of force Because the deflection is more important wider range of force can be obtain for useful movement. For example a spring used for tiping segment, by using a 0.018×0.025 SS a moment of 3500gm/mm can be obtain. The same level can be obtain with a continuous wire but on a range too small to be clinicaly usefull and the side effect are not controlable.

The segmented mechanic principle mechanical advantage range of force A classic a application is the uprighting of a seconde molar. If a continuous wire was used a whole sequence of wire would have to be used, to allow the big wire diameter to be used. The reactive force would be exerce mainly on the first molar leading to a possible canting By using a segmental mechanic the reactive force is evenly distributed on the arch minimising the unwanted tooth movement

The segmented mechanic principle mechanical advantage range of force Intrusion of the lower incisor necessity extremely low force. With a reverse curve of spee arch two problem 1 The force deliver to the incisive cannot be measured and the direction of the force can not be controlled 2 The force are too important and lead to and extrusion of the posterior sector. This effect is increase as the wire increase in size. With the segmented technique the long range of activation means that low force can be delivered consistently with a relatively constant direction. The force can be precisely measure and adapted to the patient which can be very useful with patient presenting a loss of alveolar bone. Publication have show that true incisor intrusion is obtainable by segmented technics ( intrusion arch or utility arch) but the range of movement obtainable is less important than with miniscrew also there will be movement on the anchorage segment

The segmented mechanic treatment sequence During the first phase of treatment the futur unit are chosen. The teeth are level and aligne in each segment if the unite is more than one teeth. Once align he teeth are solidarize with a rigid wire inside each unite. It is the BASE ARCH. In the posterior sector the use of bracket and tube is recommanded The tube is use for the insertion of the base arch Pr Burstone advise the use of a ×0.028 stainless stell wire in the posterior sectore. To be able to move the teeth as one unite the teeth have to be solidarized together by a rigide and passive system Because there is few teeth by unite the wire bending is more easy and predictable.

The segmented mechanic treatment sequence Usually the posteriror segment are soliderize together The force are then applied from one unit to the other (usually no more than thee unit) At this stage because only segment are moved withou sharing a common archwire only frictionless mechanic will occures

The segmented mechanic treatment sequence Because there is no archwire to guide the unite during the movement and prevent rotation, the unit are moved by using a Begg like mechanic. The crown is first type in on direction Then the apex is move in the same direction

The segmented mechanic treatment sequence In extraction case if there is initially not enough space for aligning the anterior segment the canine are first retracted then the anterior segment is then aligned

The segmented mechanic treatment sequence The segment are then level and aligne in relation to each other. It is at this stage that canting, asymmetry or midline deviation are corrected. Once a correct relation has been obtain the space are closed by tipping At this stage the occlusion worsen sgnificantly.

The segmented mechanic treatment sequence When the space are close and the axe of the segment corrected continous archwire are used Levelling and the finishing are then performed for obtaining correct occlusion and esthetics resuts

CLINICAL MODIFICATION IN ROOT CORRECTION PHASE IN SEGMENTED ARCH TECHNIQUE World J Orthod 2006; 7: Daniel Ianni Filho, DDS, MS Klaus Fernando Cardoso Bernardo, DDS Adriana Prad Calheta DDS Eduardo Serpa Vieira, DDS

Rational for this article When space closure between the two unit have been obtain by tipping of the crown of one of the unite, the next step is to correct the axis of each unite At this stage there is a strong tendency of space reopening between the two unites. To counteract this tendency Burstone advise to use a ligature before to do corrective root tipping. But even with this method space reopening is frequent. This article describe a modification of the segmented arch technic to counter this tendency.

Space closure in SAT During the space closure the unit are moved by typing. Because there is only two unite at this stage the force system is perfectly determinate The force apply can be control both in intensity, sense and direction. As a result the M/F ratio is controlled The basic principle is to tip the crown of the unite you want to move and tip the root of the unite you want to keep in the same position.

Space closure in SAT For example in this case you want to mesialize the posterior unit and conserve the position of the anterior unit. The moment to force ratio is adapted to produce crown tipping of the posterior unit and root tipping of the anterior one

Space closure in SAT There will also have an intrusive force on the unite were the crown is tip and an extrusive fore on the unite were the root are torque This can be better understood with the V principle

Space closure in SAT Study have shown that when a V-bend is place at a distance of 1/3 between two bracket the following system will be created. This can be simulated with a spring by creating an angle of activation of 45° on one unite and an angle of 15° on the other one As a result the two unit will come closer to each other in the vertical dimension

Space closure in SAT Ligature wire will not prevent space reopening As the two unite came to the same level the distance between two ligatured teeth will decrease and the ligature will become loose allowing space reoppening.

Space closure in SAT Study have also shown that when a bend is preactivated in all case a horizontal force will be generated In the case of the root spring the horizontal component on each spring act in opposite direction and tend to reopen the space

Space closure in SAT The ligature wire are ineffactive because they become loose. To solve the problem the autor suggest to applied an opposite horizontal force using a NiTi coil spring. In this case elatic are inadecate because there is a rapide decay of the force they delivered The root spring delivers the opening force constantly,

Space closure in SAT The space is first close in a classic way by tipping the crown When the root spring is engaged, a Niti coil spring delivering a force of 300 gm is fixe on the two segments If space beggin to appear the clinician know that the force is not sufficient and must be increase

Conclusion Even in following this protocol the author observe that in some case space will appears Further study are needed on the properties of NiTi close spring.