Isofocusing Chromatography Prepared by- Shirin Akhter.

Slides:



Advertisements
Similar presentations
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
Advertisements

Introduction to Chromatography
Umair Saleem Methods in protein chemistry Hydrophobic interaction chromatography.
Size Exclusion Chromatography
Separation of molecules and determination of there molecular weight by gel filtration chromatography. Experiment 7 BCH 333.
Chromatography for Protein purification 1
Ion Exchange Laboratory. Today’s Schedule Pre-lab discussion Ion Exchange and Spectrophotometer Ion exchange experiment.
ION EXCHANGE CHROMATOGRAPHY PREPARED BY- MD.MARUF HASSAN.
Commonly used separation techniques SS ize exclusion II on exchange AA ffinity RR eversed phase, HH ydrophobic interaction.
Protein Purification Strategies Course: Methods in protein chemistry Rahman M. Mahfuzur 2012/01/11 SLU.
Isoelectric Focusing Technique combining ideas of isoelectric points and electric fields Very high resolution technique for protein 1,3.
IEX Chromatography Presented by: Nikki Apostolakis Helen So Tiffany Yu CHEE450: Engineering Biology.
Electrophoretic techniques. Introduction: _The term electrophoresis describe the migration of a charged particle under the influence of an electric field.
Gel filtration Chromatography
Techniques in Protein Biochemistry Chapter 3. Problem: isolation & analysis of protein or aa found in cell Assumption: can somehow analyze for wanted.
Salting out is a method of separating proteins based on the principle that proteins are less soluble at high salt concentrations. The salt concentration.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Polyacrylamide Gel Electrophoresis
Gel Filtration Chromatography.
Separation of proteins by ion exchange chromatography
Chromatography Chapter 4 1 Dr Gihan Gawish. Definition Dr Gihan Gawish  Ion-exchange chromatography (or ion chromatography) is a process that allows.
Ion Exchange Chromatography. Some ion exchangers are regarded as weak, that is functioning best over a comparatively narrow pH range, while others.
Biochemical instrumental analysis-7 Dr. Maha Al-Sedik.
Chromatography Desalting and Affinity. Chromatography Technique to separate components of a mixture by passing them through a matrix. –A solvent is used.
Qualitative Analysis of Product
Chapter Five Protein Purification and Characterization Techniques
Types of Mechanism in the Chromatography
Biochemistry February Lecture Analytical & Preparative Protein Chemistry II.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Electrophoresis PAGE Dr Gihan Gawish.
Analysis of Proteins and Peptides Amino acid composition Molecular weight Isoelectric point Subunit structure Prosthetic groups Solubility Biological activity.
Overview of 2DE Complex mixture of proteins
BIOCHEMICAL METHODS USED IN PROTEN PURIFICATION AND CHARACTERIZATION
In 1949, a team led by chemist Linus Pauling placed hemoglobin solutions from people with a disabling form of anemia and from healthy volunteers in an.
Lab 6 Salt fractionation In aqueous environments salt ions interact strongly with their complementary charge on a water molecule If the concentration of.
Ion exchange chromatography
Supercritical Fluid Chromatography Introduction : Supercritical Fluid Chromatography (SFC) is a hybrid of gas and liquid chromatography that combines some.
Protein Primary Sequence Protein analysis road map: Bioassay design Isolation/purification Analysis Sequencing.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
Isoelectric Focusing Fundamental of Bioprocess Engineering Laboratory
Biochemical instrumental analysis - 8 Dr. Maha Al-Sedik 2015 CLS 332.
Separation techniques ?. Molecules can be separated: Chemically: by charge, by action with specific reagents Physically: by solubility, by molecular weight,
HPLC.
Protein Purification by Ion Exchange Chromatography
Introduction to Instrumental Analysis - Chromatography
Protein Purification for Crystallization Dr Muhammad Imran Forman Christian College (A Chartered University) Dr Muhammad Imran Forman Christian College.
Analytical biochemistry lab KAU-biochemistry dep. L. Nouf Alshareef
KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 T.A Nouf Alshareef
Welcome To my presentation.
Ion exchange chromatography
Purification of immunoglubin by ion exchange chromatography Bahiya Osrah
Lab 6 Ig Purification What will the Ig be used for? How pure does it need to be? What is the source of the antibody (serum, ascites, cell culture supernatant)
Chromatography PlanarColumn Paper TLC (Thin layer chromatography)
Principles of chromatography
Tymoczko • Berg • Stryer © 2015 W. H. Freeman and Company
Bioseparation II Chromatography Techniques. Chromatography Most widely used purification technique used for biomolecules. Most widely used purification.
ELECTROPHORETIC METHODS
Tutorial 11 Modes and Methods in Capillary Electrophoresis
Purification Of Proteins.
Amino Acids, Peptides, and Proteins
Lecture 2   ELECTROPHORESIS Electrophoresis is a separation technique that is based on the mobility of the ions in an electric field.. it is a Greek word.
Ion Exchange Chromatography
ISOELECTRIC FOCUSING Electrophoretic method that separates proteins according to the iso-electric points Is ideal for seperation of amphoteric substances.
Separation of Molecules by Ion Exchange Chromatography
Gel Filtration Chromatography.
Separation of Molecules by Ion Exchange Chromatography
Principle of separation of different components:
INTRODUCTION TO ELECTROPHORESIS
Downstream Processing
Experiment 3 Separation of proteins by Anion exchange chromatography
Presentation transcript:

Isofocusing Chromatography Prepared by- Shirin Akhter

Introduction Iso-focusing chromatography is a chromatography technique that separates protein according to differences in their isoelectric point (PI). Its a polishing step for partially purified samples. Its a high resolution technique and can be used for analytical separation. We can be used this technique as a complementary technique when the protein is not resolved by other chromatography technique such as ion exchange, size.

Relationship between protein PH and net charge Overall net charge of the protein changes according to the PH. The PI of each protein is the PH at which the protein has zero surface charge. When the PH above its isoelectric point, protein will bind to positively charged medium or anion exchanger. When the PH below its PI, protein will bind to negatively charged medium or cation exchanger. In isofocusing technique, proteins with different PIs can be separated by being passed through the chromatofocusing column which is packed with a specifically designed medium. Here the PH gradient is generated on the column by specifically designed and matched amphoteric buffers. Proteins elute in order to their isoelectric point.

Figure- Separating proteins according to their isoelectric points by chromatofocusing.

Mechanism of separation Protein separation according to their different PIs, the chromatofocusing medium is equilibrated with start buffer at high PH. An elution buffer in the column begins to titrate the amines on the medium and the proteins. After pre-gradient volume of elution buffer has passed, sample is applied to the column. Proteins in the sample that are at PH above their PI are negatively charged which retained near top of the column.

Proteins that are at a PH below their PI begin to migrate down the column and will not bind until their PH above their PI. When the proteins migrate down the column, PH of surroundings increases and proteins reaches at PH above their PI which will bind column again. The protein with highest PI elute first and the protein with lowest PI elute last.

Figure: Proteins with different PIs separates as they pass through the column.

Media and buffer for this technique We can use different types of media for this technique such as- Mono P- for fast separation. Mono P 5/200 GL- for highest resolution separation. PBE 94- for scaling up from Mono P. PBE 118- when PH gradient above PH 9.

Different buffers based on the PH gradient- Polybuffer 74- for PH gradient between 7 and 4. Polybuffer 96- for PH gradient should begin above PH 7. Pharmalyte- PH

Drawback for this technique It is less suitable for the isolation of proteins that precipitate irreversibly at or near their isoelectric point because these proteins are likely to precipitate on the column if they reach a high enough concentration.

Isoelectric focusing: This is also a high resolution method for the separation of proteins, peptide and enzymes. Principle of this method: In a pH gradient the sample components migrate towards the anode or the cathode to the pH values, where their net charges are zero: their isoelectric points (pI).

Focusing effect: A protein diffuse away from its pI, it would gain a charge and migrate back. Estimation of isoelectric point for the protein: The isoelectric points of the proteins can be estimated with a calibration curve using marker proteins.

Equipment: Isoelectric focusing (IEF) is mostly run in horizontal gels. The reason behind to run this method in horizontal gels: As IEF separates only according to the charge, the gel matrix must contain large pore sizes. Such a soft gel can slide down between vertical glass plates. The gel should preferably be cast on a film support. Isoelectric focusing requires efficient cooling and exact temperature control. This is optimally achieved on a horizontal ceramics cooling plate connected to a thermostatic circulator, or a peltier cooling plate.

Samples have to be applied on a defined pH location within the pH gradient in order to avoid aggregation and precipitation of some proteins. This is only possible on a horizontal gel with an open surface. Sharply focused bands can only be obtained with a high field strength, high voltages have to be applied. Only horizontal equipment can meet the necessary safety precautions.

Sample application: The samples are applied on the surface of the gels. The mode of sample application is dependent on the sample composition and the IEF gel type. Because the gradient is sensitive to high salt and buffer concentrations, it is very helpful to desalt the samples before application.

The procedure of an IEF run: The running condition should be optimized because it is very important to prevent precipitation and aggregation of proteins, and to achieve good reproducibility. Temperature control is important, because pIs are highly dependent on the temperature. Prefocusing phase should be performed in order to establish the gradient. Samples have to be loaded on the optimized location with the optimized mode.

Sample entry should be performed at low field strength to prevent aggregation. The separation time is a compromise between letting all proteins reach their pIs and keeping the gradient drift to a minimum. After the run, the proteins are fixed by immunofixation and stained for visualization.

Conclusion: Although isofocusing is foreign to many process developers, their fractionation characteristic has advantage to serious evaluation on a routine basis. It has limitations and it has a distinct set of development variables, but there are neither more limitations nor variables than any other technique. They are simply different. For bulk separation, it is just as powerful as salt-gradient ion exchange, hydrophobic interaction, or size exclusion chromatography.

Thank You