Jessica Kishimoto The University of Western Ontario Medical Biophysics Undergrad April 7, 2010 The Effect of Dose on Image Quality When Using an Image Based Proximity Mapping Technique
The Effect of Dose on Image Quality when using an Image Based Proximity Mapping Technique Jessica Kishimoto The University of Western Ontario Medical Biophysics Undergrad April 7, 2010
Introduction A previously developed technique called proximity mapping has been developed to non- invasively examine joint congruency using reconstructed images acquired using x-ray computed tomography (CT) One concern with this approach however, is exposure to unnecessarily high amounts of radiation
Hypothesis There will be a dose of CT which will allow for good images, but minimize the risk associated with excess radiation
Objectives To show the differences between high and low dose images, and whether or not these differences might be diagnostically important.
What is dose? This is value calculated from measured radiation exposure and an estimate of the amount absorbed by different body tissues This is measured in CTDIvol, which is the CT Dose Index, and measures the average dose over the scanned volume The normal parameters of a scan are 100mA and a pitch of 0.984, which would result in a dose of around 8 CTDIvol.
Methods Multiple raw images from CT scans at different doses were used to reconstruct a 3D image Cropping was then used to remove either the humerus/scapula components to isolate the bone of interest Thresholding was employed to create the best the bone. Smoothing was used when creating the bone model if the images were really bad Using a proximity mapping program, it was possible to deteremine where the modeled bones were articulating.
Results Low doseHigh dose
Results Super low doseHigh dose
Results Low dose Medium dose High dose
Results Overlapping low and medium dose Red – low, beige - medium
Results Medium doseLow dose
Results Low dose
Results Medium dose
Discussion There appears to be large differences between the low, medium and high dose images. Perhaps part of this is due to different thresholds used to create the images Instead of having the goal of the best image By using the same threshold for all images they could be more similar
Conclusion There appears to be a difference, which could cause diagnostic errors in between high and low dose images. This needs to be investigated much further before any real conclusions can be made towards the optimal amount of dose needed to create a good image.