Planmeca Intra.

Slides:



Advertisements
Similar presentations
Advanced Biomedical Imaging Lecture 3
Advertisements

Planmeca ProMax tomography
EVERYTHING YOU WANTED TO KNOW BUT WERE AFRAID TO ASK!!!!
[Radiography] Technique - Exposure Factors
Periapical radiography
Radiology – Paralleling, Bisecting, Bitewing
The best choice for dental office
The Bitewing Technique
The best choice for dental office. Easy to operate Open and easy patient access Side entry and open view No mirror, no traumatic view of injuries Triple.
ProMax 3D all in one ProMax 3D – Cone Beam Volumetric Tomography
Planmeca ProX.
High Voltage Supply. High voltage Supplies Generators should provide a smooth constant high voltage to the X-ray tube.
Image Reconstruction.
Line focus principle Heal effect Ratings Tube failure
 The panoramic unit is often used to cut down on the amount of radiation the patient is exposed too pared to a CMX. This technique is also utilized to.
Without reference, identify principles relating to Intraoral X-Ray with at least 70 percent accuracy.
4 Producing Quality Radiographs.
Advanced Biomedical Imaging Lecture 4 Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
Conventional Radiography
Bitewing radiography.
Intraoral Radiographic Techniques
Copyright © 2006 Thomson Delmar Learning. ALL RIGHTS RESERVED. 1 PowerPoint ® Presentation for Dental Radiology with Labs Module: Dental Radiology.
Chapter 7 Radiographic Image Formation and Exposure Factors.
Dental Radiography Equipment
RADIOLOGY. NEXT GENERATION SCIENCE / COMMON CORE STANDARDS ADDRESSED! CCSS.ELA-Literacy.RST Determine the central ideas or conclusions of a text;
MAMMO QC – covered in week 8
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Analyzing the Image Density. Density Overall blackening of the image.
The Bisecting Technique
OCCLUSAL EXPOSURE TECHNIQUES. At times, more extensive radiographic views of oral tissues are desired than are obtainable with periapical or bite-wing.
Bisecting angle technique patient holds the film or sensor with his finger short cone  magnified apexes.
CHAPTER 16 ORAL RADIOGRAPHY.
13 Intraoral Radiographic Precedures.
DENTAL RADIOGRAPH. SHAMA ISMAIL 12BME28..
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
The X-ray Imaging System
Shutter Speed Afzaal Yousaf Baig
DR:TAGWA MIERGHANI MOHAMED.  There are variety between intra and extra oral machine design.  The radiographer must have clear understanding of the operating.
RADIOLOGIC IMAGING EQUIPMENT 1. THE X-RAY ROOM 2.
The Bisecting Technique
Current UK legislation and guidelines for radiation protection of patients and staff Prepared by: Dr D. Mladenova.
Quality Control.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Dr Mohamed El Safwany, MD.
Components of Image Quality & Radiographic Artifacts Radiologic Technology A Spring 2010 Final Final.
December 2002 Endos DC has been designed from scratch. Every component of the system is completely new: –new generator –new tubehead –new arm –new timer.
DIGITAL RADIOGRAPHY DA 105.
Exposure Factors or Prime Factors
Radiography. Roentgen tube – x- ray tube: Cathode – anode – tension Catode (heated) - electrons –against anode – brake - x ray radiation originates.
AC and DC generators Global Technologies Company June 2002 A Conventional generators (AC) The mains alternating current (50 Hz) is applied to a circuit.
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Radiographic Quality Visibility and Sharpness
Radiation Sources in medicine diagnostic Radiology
Week 2: Radiographic Equipment
COMPUTED TOMOGRAPHY - I RAD 365 CT - Scan
Dental raduology د. باسم الاعسم.
Copyright ©2012 by Pearson Education, Inc. All rights reserved. Essentials of Dental Radiography for Dental Assistants and Hygienists, Ninth Edition Evelyn.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
Intraoral Radiographic Examination. Intraoral Radiographic Examination The intraoral radiographic examination is a radiographic inspection of teeth &
Radiology Steps in radiation production Kilovoltage and voltage.
Digital Radiography Chapter 26. Digital radiographs Different from analog images (traditional radiographs). Filmless imaging using pixels. Instant images.
An early x-ray by Wilhem Rontgen
8 November 1895, produced and detected electromagnetic radiation in a wavelength range today known as X- rays or Röntgen rays, electromagnetic radiationwavelengthX-
Exposure Factors or Prime Factors
RADIATION PROTECTION 04/12/2016.
Dave Kelton Schick Technologies, Inc.
Dental X - Ray Film.
Factors Effecting the Production
Exposure Factors Chapter 4
Generation of X-rays Q&A
Presentation transcript:

Planmeca Intra

Bisecting angle technique Patient holds the film or sensor with his finger Short cone magnified apexes

Parallel technique Film/sensor holder Long cone

Image quality Small focal spot 0.7mm -> small unsharpness Optional long cone small unsharpness Geometric requirements for good images are met

Image quality High-voltage generator Constant potential (DC) X-ray generation High operating frequency (66 kHz) 25% less radiation to patient compared to conventional AC generators Shorter exposure times Improved contrast Is not affected by line voltage variations Readiness for digital systems

Kilovolts and image quality Lower anode voltage higher contrast, more suitable for endodontic, apex and bone structure diagnosis Medium anode voltages boarder grey scale, suitable for caries detection Higher anode voltages longest grey scale spectrum for periodontal disease diagnosis 50 kV 60 kV 70 kV

Milliampers and image quality With variable milliamperes (2 - 8 mA) we can take the whole advantage of the modern digital imaging systems and new high-speed films.

Adjustable settings adjustable kV setting (50, 53, 55, 57, 60 ,63, 66, 70)‏ different diagnostic needs are fulfilled adjustable mA (2-8 mA)‏ maximum dose reduction possible with modern digital sensor systems and high-speed films

X-ray arm smooth movements drift-free positioning no vibrations easy, quick and accurate positioning

X-ray Tube design non-symmetric form tubehead and cone have a common smooth plane easy targeting along the smooth surface close to the patient’s chest in occlusal images

Controls 66 pre-programmed quick settings modality selection to choose film, imaging plate or sensor density setting adult/child selection periapicals for different teeth occlusal bite-wing / endo Quick setting allow ALWAYS to have right exposure values for individual cases

Control panel options hand held control panel remote exposure station all controls easily at hand for exposure

Standard wall-mount 4 extension arm lengths reach 1525 – 1975 mm special lengths available with custom order up to 2300 mm

Other mounting alternatives dental unit mount mobile base mount

Other mounting alternatives ceiling mount ceiling mount with operating light floor column mount single stud mount pass-through mount

The End More information: Erkki Hiltunen Product Manager, X-rays tel: +358 20 7795 456 erkki.hiltunen@planmeca.com Mark Niemi tel: +358 20 7795 743 mark.niemi@planmeca.com More information: Osku Sundqvist Product Manager, Software tel: +358 20 7795 793 osku.sundqvist@planmeca.com 4/2011