Flotection: Building Main Shutoff System

Slides:



Advertisements
Similar presentations
Lockout/Tagout Awareness Training
Advertisements

Club Car IQ Technical Information
The D.C. Scout Battery Distribution System Ground Locator
SWITCHES, FUSES, & CIRCUIT BREAKERS
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
AC-SSC-1 Installation and operation manual
HYDRAULICS & PNEUMATICS
Getting Started Product Description Setting Parameters How does it work Wiring Diagram.
FoamPro 1600 Series Fully automatic Class A foam ONLY
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
7.3.2 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Electronic Ignition.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
California Friendly ® Landscape Training Irrigation System Troubleshooting The Metropolitan Water District of Southern California and the Family of Southern.
0.05 s s Fuses L.O.: What do we use fuses and circuit breakers for? How to use the correct fuse June 08, Q4, page 9.
Lesson.5: Fuses and Safe Plugs
Electrical Electricity Fuses Relays Solenoids Electrical Testing
EGD ELECTRICAL ELECTRICAL SYMBOLS.
Prof. David R. Jackson ECE Dept. Fall 2014 Notes 5 ECE 2317 Applied Electricity and Magnetism Notes prepared by the EM Group University of Houston 1.
By Carlin Bright. Electricity The flow of electrons in a conductor.
Electro-Pneumatics Module 1
Industrial Machine Control
Continue The information provided in this training module covers the schematic flow charts for all ovens and ranges that utilized a preheat board, Self.
GCS 300 System Operation Application – Level 1.
Operation Sabbath Mode - SELECT PROGRAM - Lights, alarms and fans Normal Sabbath Overview.
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
ADT490 TroubleShooting Locating Opens A. 2 Introduction Breakdown in Circuit Integrity -> Trouble Metallic continuity interrupted an “ open ” occurs System.
The Basics Electronics. To familiarise yourself with electronics To have an understanding of how and why we test electronic circuits. To complete a test.
Push Button Station and Relay
Quick Start Guide for Flex Flow Pump
Fujitsu Training Documentation Hardware Installation
Blower-/Fan Coil-Actuator
Neutral current is zero
HV Battery Assembly.
DESCRIPTION AND GUIDE TO OPERATIONS
Presented by SARAVANA KUMAR . M (EEE III Year) SBM CET
Notes 5 ECE 3318 Applied Electricity and Magnetism Fall 2017
GROUND-FAULT GROUND-CHECK MONITOR
UK TECHNICAL SOLUTIONS INTERNATIONAL
Side Light Switch circuit
The D.C. Scout Battery Distribution System Ground Locator
Grid feeding monitoring relay
HVI HIPOT TEST SET Pft sERIES.
Module 1: System Overview
Programming Timers.
Associated Hazards and Safety Practices
The BioTector B3500ul TOC analyzer Process Tests
Personal Protective Equipment
Roof Top Unit Overview (MAGNUM)
Lesson 14: Introduction To Sequential Control
MINNY 16 TROUBLESHOOTING Doc THE MACHINE DOES NOT START
ET 438B Sequential Control and Data Acquisition
Winch Signalling System
The Safe Use of Electricity
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Universal Interrupted Electronic Oil Primary R7184U Training Module
6. USING THE TDR200 IN ANALOGUE MODE
Wiring Circuits Lesson Plan PSTS: C6-7.
ENTER OUR FRIEND MR. RELAY
System 57 Gas Control System
Introduction to Electro-pneumatic
FOAMPRO 2001 / 2002 Pump Panel. FOAMPRO 2001 / 2002 Pump Panel.
Level 2 Electrical and Electronic 3
Fluid Power System Electrical Control
Presentation transcript:

Flotection: Building Main Shutoff System

Overview of System Retail stores have a requirement for night time monitoring of the Domestic Water Supply. When flow is detected, during the hours the store is closed, the system shuts off this supply and flood damage is thereby prevented. System operation: Tie-in to EMS controller : The store EMS signals the panel to go into Open/Day mode or Closed/Night Mode on a daily basis. Power to the EMS relay in the panel puts the system in Closed/Night Mode. No power to the EMS relay puts the system onto Open/Day Mode. Dry contacts on Relay 2 and 3 allow Flow Alarm monitoring and Valve Status monitoring back to the EMS. Day/Occupied : On power being supplied to the 2 pole main breaker the panel will go into the Open/Day mode. This is the default mode. The EMS relay coil in the panel is not receiving power from the EMS at this point The Main valve in the main domestic water supply line to the store interior is powered open. A Bypass valve in the 1 ½” bypass line is un-powered and is spring driven to the closed position. A green light indicates the Main Valve is fully open and power to the panel is connected. The Valve Status contact is open to indicate to the EMS that the Main Valve is open. Night/Unoccupied: After store hours the local EMS signals the panel to go into Close/Away mode. The EMS relay coil in the panel is now receiving power from the EMS. The Main Valve is powered closed. The Bypass valve in the 1 ½” bypass line is powered open. This bypass line allows low volume water flow to the store. A yellow light indicates the Main Valve is fully closed . The Valve Status contact is closed to indicate to the EMS that the Main Valve is closed. The panel employs electrical interlocking relays to prevent any over-riding signal to be sent to the main valve during Night/Away mode.

Overview of System, cont. Alarm mode: The Flow Sensor detects water flowing through the bypass line. The Time Delay Relay times out and closes a on-delay contact (adjustable 0-60 sec.) The Bypass Valve is de-energized allowing it to spring closed. The Main Valve remains closed. The water is now shut off completely. A Red light indicates an alarm condition. The Flow Alarm Status contact closes and the Valve Status contact remains closed. A dry contact , available for an additional alarm circuit, has now closed To Reset A qualified person must go to the control panel and reset the system via a single Red button on the panel door. No remote reset is permitted. After reset the system returns to the previous EMS selected mode, Open/Day or Closed/Night. To Test A qualified person may operate a Test toggle switch in the panel. In Test mode (ON) the panel is forced into closed/night mode. the operator can observe that that the Main valve is closed and the Bypass valve is open. Indicators on each valve show the position of the valve. In the Day/Open Mode the indicators show the main has opened and the Bypass is closed. Regular testing ensures the system is operating normally

Example of Horizontal Supply Installation 12’ cords (supplied) to prewired parts Flotection Control panel 120V 1 ½ Valve w/prewired 120V actuator 120V Supply and EMS connections 120V pre wired flow sensor 24V ac/dc EMS Relay (internal) Main Valve w/prewired 120V Actuator

Installing the Control Panel Choose a suitable location to mount the panel. The connector cords are 12’ long. IMPORTANT SAFETY CAUTION: Pull the fuse holder open to disconnect panel from power source until ready to energize system. Connect 120V supply voltage to the main 2 Pole fuse holder and install the fuses. To connect to the EMS system: Connect 24Vac/dc power from the EMS to the blue terminals marked “+” and “-”. Power to these terminals will force the system into Night/Away mode. Flow Alarm Indication – connect to terminal 29 and 33 from EMS. A signal will flow to EMS when the relay operates, indicating there has been flow. Valve Open/Close Status – connect to terminal 35 and 39 from EMS. A signal will flow to EMS indicating open/closed position of main valve. Second alarm signal – connect to terminal 47 and 49. A signal will flow to an additional alarm indicator Notes: When the system is connected and energized (fuse holder closed) the Main Valve will open. When in the fully OPEN position the green light will serve to indicate the power is connected and the Open position of the Main valve. The Flow sensor switch is now powered but the bypass valve is closed, no flow detected.

Field Connections to Numbered Terminal Blocks   Line N R2 R3 R4 Terminal# L1 L2 29 33 35 39 47 49 51 52 IN OUT  (+)  (-) Function Power EMS - Flow Alarm status EMS - Valve status OPEN/CLOSE Alarm Contact EMS Relay Power 24V ac/dc For wiring schematic, see Drwg. ST4-M006

Kit with Main Valve, Bypass Valve, Flow Sensor (all prewired) Order by size of main domestic water line These prewired parts plug directly into the control panel Part# Size FLO120V1.5NP 1.5” FLO120V2.0NP 2” FLO120V2.5NP 2.5” FLO120V3.0NP 3” FLO120V4.0NP 4” FLO120V5.0NP 5” FLO120V6.0NP 6”

Installing the Main Valve, Bypass Valve and Flow Sensor Install main valve in line with main water supply. Follow instructions provided with main valve. Install Belimo ball valve in 1 ½” bypass line. Install the flow sensor in the bypass line. A street fitting (1”) and a Tee (1 1/2x1”) are provided. This ensures the correct depth of the sensor into the bypass line. Plug the cords from the control panel into the main valve, bypass valve and flow sensor. These parts have been prewired to ensure the correct functioning of the system. These kits plug into the control panel on the previous page

Testing/Operating the System

Test Toggle Switch The toggle switch mounted on the standoff plate must be in the OFF (normal mode) position for daytime operation, The toggle switch in the ON position forces the system into Close/Night mode Toggle to the ON position and observe the Main Valve and Bypass valve indicators. The Main Valve will close and the indicator will rotate to show “Closed”, the Bypass valve will rotate to position 9. Toggle to the Off position and observe that the Main Valve opens and the Bypass valve closes. The system is now in the Open/Day mode. Toggle switch shown in ON (Test) position

Day or Occupied Mode Condition: No Faults The Energy Management System sends a signal that the store is open for the day.  An open signal is sent to the Control Panel that commands the opening of the Main Valve. As the Main valve totally opens a micro-switch inside of the Main valve energizes the OPEN/DAY Pilot Light. Power is removed from the bypass valve and the valve closes (exercising the valve daily) The Flow sensor switch is now powered but the bypass valve is closed, no flow detected.

Night or Unoccupied Mode Condition: No Faults The Energy Management System sends a signal that the store is closed for the night. A close signal is sent to the Valve Controller that commands the closing of the Main Valve. As the Main valve totally closes a micro-switch inside of the Main valve energizes the close indicator A yellow pilot light illuminates. The Bypass Valve is opened by the 120V actuator. The flow sensing device monitors the Bypass Piping for any water flow. A relay contact for the external monitoring of the Main Valve closes, indicating to the EMS that the Main Valve is closed.

Night or Unoccupied Mode Condition: Fault with Main Valve closed The Sensing device detects water flow through the Bypass piping This detection energizes a Time Delay Relay, and after 60 seconds (adjustable) of water flow the Time Delay Relay activates a lockout relay. The lockout relay immediately signals a Fault Condition, closing both the Main Valve and the Bypass Valve and removes all external signals controlling both of the valves.  The EMS received a Fault indication.

Reset Condition: Fault with Main Valve closed After an on-site visual Inspection of the water piping has been confirmed, the fault has been corrected or there is no problems or breaks. The reset button must be activated by a person on-site, to restore the normal operation of the Valve Controller. When reset the bypass valve will re-open, if there is less than fault condition water flow. Reset Button

Status Outputs Flow Alarm Indication – connect to terminal 29 and 33 from EMS A signal will flow to EMS indicating there has been water flow. Valve Open/Close Status – connect to terminal 35 and 39 from EMS. A signal will flow to EMS indicating open or closed position of main valve. Second alarm signal – connect to terminal 47 and 49 A signal will flow to an additional alarm indicator.

Manifold Suggestions Overall length 60” Non grooved pipe at both ends 8” 12” 36” 8” 60”

Technical Support Call: Sam Cordaro 630-712-1400 Email: sam@smcsalesco.com