M. Weiss, C. Doell, N. Koepfer, C. Madjdpour, K. Woitzek, V. Bernet 

Slides:



Advertisements
Similar presentations
Assessing the performance of the Whisperflow® continuous positive airway pressure generator: a bench study  G.W. Glover, S.J. Fletcher  British Journal.
Advertisements

Prospective randomized controlled multi-centre trial of cuffed or uncuffed endotracheal tubes in small children#   M. Weiss, A. Dullenkopf, J.E. Fischer,
B.D. Woods, R.N. Sladen  British Journal of Anaesthesia 
Oxygen delivery through high-flow nasal cannulae increase end-expiratory lung volume and reduce respiratory rate in post-cardiac surgical patients  A.
Sun D. A. , Warriner C. B. , Parsons D. G. , Klein R. , Umedaly H. S
The upper airway during anaesthesia
Positive pressure ventilation during fibreoptic intubation: comparison of the laryngeal mask airway, intubating laryngeal mask and endoscopy mask techniques 
Parkinson's disease and anaesthesia
Double-lumen tubes and auto-PEEP during one-lung ventilation
Airway Scope and gum elastic bougie with Macintosh laryngoscope for tracheal intubation in patients with simulated restricted neck mobility  R. Komatsu,
Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements:
Tracheal intubation using a Macintosh laryngoscope or a GlideScope® in 15 patients with cervical spine immobilization  F Agrò, G Barzoi, F Montecchia 
Weiss M. , Gerber A.C. , Dullenkopf A.   British Journal of Anaesthesia 
G Turner, M.J. Goldacre, T Lambert, J.W. Sear 
Lung protective strategies in anaesthesia
Controlled comparison between betamethasone gel and lidocaine jelly applied over tracheal tube to reduce postoperative sore throat, cough, and hoarseness.
Preoxygenation: a comparison of three different breathing systems
Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study†  G. Wallon, A. Bonnet, C. Guérin  British.
Mind the gap when performing emergency front-of-neck access
Inflating LMA with normal saline: 14 yr after
Recent advances in gas exchange measurement in intensive care patients
J. Hofland, I. GuÕltuna, R. Tenbrinck  British Journal of Anaesthesia 
Modification of tracheal tubes
P. Michelet, A. Roch, D. Brousse, X. -B. D'Journo, F. Bregeon, D
Electrocardiographic alterations during intravascular application of three different test doses of bupivacaine and epinephrine: experimental study in.
I. Merino, X. Borrat, J. Balust, S. Delgado, A. M. Lacy, J. Vidal, G
Correction to the paper ‘Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study’  M Hallbäck,
The modified ventilating tube changer to facilitate tracheal intubation using the GlideScope® in patients with a limited mouth opening  F.S. Xue, Q.Y.
Psychology of pain British Journal of Anaesthesia
Psoas compartment block for lower extremity surgery: a meta-analysis
New ventilators for the ICU—usefulness of lung performance reporting
Comparative study of topical anaesthesia with lidocaine 2% vs levobupivacaine 0.75% in cataract surgery  S.A. Fernández, E. Dios, J.C. Diz  British Journal.
V. Uppal, G. Fletcher, J. Kinsella  British Journal of Anaesthesia 
H. Tønnesen, P.R. Nielsen, J.B. Lauritzen, A.M. Møller 
Usefulness of spirometry in air leak evaluation during laparoscopic surgery in an obese patient with laryngeal mask airway Supreme™  M Carron, U Freo,
Successful intubation using retrograde trans-tracheal illumination after laryngoscope light source failure  J Hudson, M Vu, E Vu  British Journal of Anaesthesia 
Magnesium sulphate as a technique of hypotensive anaesthesia
New approach to anaesthetizing a patient at risk of pulmonary aspiration with a Montgomery T-tube in situ  K.M.A. Wouters, R. Byreddy, M. Gleeson, A.P.
Physiological effects of hyperchloraemia and acidosis
Anaesthesia for awake craniotomy—evolution of a technique that facilitates awake neurological testing  A. Sarang, J. Dinsmore  British Journal of Anaesthesia 
R.J. Roche, C. Mackinlay, A. McLaughlin, K. Panikkar, J.D. Young 
Positive pressure ventilation: what is the real cost?
FastrachTM tubes: modifying the design for use with the LMA CTrachTM?
Effects of tracheal tube orientation on the success of intubation through an intubating laryngeal mask airway: study in Mallampati class 3 or 4 patients 
Ventilation strategies in obese patients undergoing surgery: a quantitative systematic review and meta-analysis†  M. Aldenkortt, C. Lysakowski, N. Elia,
The laryngeal tube compared with the laryngeal mask: insertion, gas leak pressure and gastric insufflation  T. Asai, A. Kawashima, I. Hidaka, S. Kawachi 
Madden B.P. , Sheth A , Ho T.B.L. , McAnulty G  
Jet or intensive care unit ventilator during simulated percutaneous transtracheal ventilation: a lung model study  Y.H. Liu, A.L. Wang, A.D. Marchese,
Pressure-controlled ventilation improves oxygenation during laparoscopic obesity surgery compared with volume-controlled ventilation  P. Cadi, T. Guenoun,
Anaesthetic staff cannot identify extremely high tracheal tube cuff pressures by palpation of the pilot balloon  S.A. Michlig  British Journal of Anaesthesia 
GlideScope® video laryngoscope: a randomized clinical trial in 203 paediatric patients†   J.-T. Kim, H.-S. Na, J.-Y. Bae, D.-W. Kim, H.-S. Kim, C.S. Kim,
Securing tracheal tubes in facial burns
M. Lichtwarck-Aschoff, A. Helmer, R. Kawati, M. Lattuada, U. H
G.J. Mar, M.J. Barrington, B.R. McGuirk  British Journal of Anaesthesia 
Thoracic paravertebral blocks in abdominal surgery – a systematic review of randomized controlled trials  K. El-Boghdadly, C. Madjdpour, K.J. Chin  British.
Parecoxib for analgesia after craniotomy
The effect of ephedrine on intubating conditions and haemodynamics during rapid tracheal intubation using propofol and rocuronium  M.D. Gopalakrishna,
Nasotracheal intubation depth in paediatric patients
J.-L. Vincent, M.M. Wilkes, R.J. Navickis 
Ventilation with the Ventrain through a small lumen catheter in the failed paediatric airway: two case reports  M.G.A. Willemsen, R. Noppens, A.L.M. Mulder,
Comparison of central venous and external jugular venous pressures during repair of proximal femoral fracture†  A.D. Leonard, C.M. Allsager, J.L. Parker,
Tension enterothorax British Journal of Anaesthesia
Heated lidocaine/tetracaine patch (Synera™, Rapydan™) compared with lidocaine/prilocaine cream (EMLA®) for topical anaesthesia before vascular access 
Cut tracheal tube and GlideRite® Rigid Stylet
C. Verghese, B. Ramaswamy  British Journal of Anaesthesia 
The laryngeal tube British Journal of Anaesthesia
Hayes-Bradley C   British Journal of Anaesthesia 
C.M. Chalmers, A.M. Bal  British Journal of Anaesthesia 
M. J. Sheen, S. -T. Ho, C. -H. Lee, Y. -C. Tsung, F. -L. Chang, S. -T
F. Neunhoeffer, T. Wahl, M. Hofbeck, H. Renk, M. Esslinger, M
Presentation transcript:

Rapid pressure compensation by automated cuff pressure controllers worsens sealing in tracheal tubes  M. Weiss, C. Doell, N. Koepfer, C. Madjdpour, K. Woitzek, V. Bernet  British Journal of Anaesthesia  Volume 102, Issue 2, Pages 273-278 (February 2009) DOI: 10.1093/bja/aen355 Copyright © 2009 British Journal of Anaesthesia Terms and Conditions

Fig 1 Cuff pressure controllers tested: (a) Cuff Pressure Manometer, Microcuff GmbH, Weinheim, Germany; (b) VBM Pressure Controller, VBM Medizintechnik GmbH, Sulz a.N., Germany; (c) Tracoe™ Pressure Controller, TRACOE medical GmbH, Frankfurt, Germany. British Journal of Anaesthesia 2009 102, 273-278DOI: (10.1093/bja/aen355) Copyright © 2009 British Journal of Anaesthesia Terms and Conditions

Fig 2 Mean ratio (%) of expiratory to inspiratory tidal volumes recorded with each of the three cuff pressure controllers and each of the four different ID 8.0 mm tracheal tube brands tested at cuff pressures of 10, 15, 20, and 25 cm H2O and at peak inflation pressure of 20 and 25 cm H2O (n=16 measurements per device, tracheal tube brand, cuff pressure and inspiratory peak pressure). British Journal of Anaesthesia 2009 102, 273-278DOI: (10.1093/bja/aen355) Copyright © 2009 British Journal of Anaesthesia Terms and Conditions

Fig 3 Mean ratio (%) of expiratory to inspiratory tidal volumes recorded with each of the three cuff pressure controllers and each of the four different ID 5.0 mm tracheal tube brands tested at cuff pressures of 10, 15, 20, and 25 cm H2O and at peak inflation pressure of 20 and 25 cm H2O (n=16 measurements per device, tracheal tube brand, cuff pressure and inspiratory peak pressure). British Journal of Anaesthesia 2009 102, 273-278DOI: (10.1093/bja/aen355) Copyright © 2009 British Journal of Anaesthesia Terms and Conditions