New features, more applications with PQube 3 Power Analyzers

Slides:



Advertisements
Similar presentations
Beckett Energy Systems
Advertisements

VSE Corporation Proprietary Information
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
Multi Functional Digital Fault Recorder
Development of Damping Algorithm Olof Samuelsson Industrial Electrical Engineering and Automation
LP33 Series UPS kVA 400Vac/CE
G650 Generator Protection & Control System
Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900E PUBLIC INFORMATION L19 - Combining the Latest Rockwell Automation® Hardware.
POWER PLANT USED IN TELECOM
Synchrophasor: Implementation,Testing & Operational Experience
Electrical Distribution Training
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
Click left mouse button to advance, “back” to return Phasefale November 2007 Presscon Network Click left mouse button to advance, “back” to return.
III ALTERNATING CURRENT Electricity is generated, transmitted, and used in the form of three-phase alternating current (AC). The current strength of AC.
Electrical Distribution Analysis & Testing Everything You Need To Know About Power Distribution By Current Solutions PC.
Cyber Security of SCADA Systems Testbed Development May1013 Group Members: Ben Kregel Justin Fitzpatrick Michael Higdon Rafi Adnan Adviser: Dr. Manimaran.
PMC-592 HMI's Front Panel Operation
DIGITAL MULTIMETER DMG
POWER FACTOR CORRECTION
Lessons Learned Implementing an IEC based Microgrid Power-Management System October 12, 2015 Presented by: Jared Mraz, P.E.
2017 WECC JSIS Report March 21, 2017.
Poseidon 4002 Rack monitoring.
Power Quality at Solar Distributed Generation Facilities
Content: Distortion at electronic loads
Summer Internship Review
[Customer Name Here] Power Monitoring Expert 8.1
Unit 02: Voltage sag (6 hrs)
Technology that lets you Trust your batteries!
August 2012 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Energy Module EM/S Energy Actuator SE/S © ABB 20 May 2018 | Slide 1.
EAS Lessons Learned Summary
Fundamentals of Harmonics
in Smart Metering Solutions
ECEN 460 Power System Operation and Control
Presented by: LADWP November 14, 2017
HARRY ALLEN TRANSFORMER REMEDIAL ACTION SCHEME (RAS)
Sahar Rahim MS-Electrical Engineering Supervisor: Dr. Nadeem Javaid

Peter Erning, PSP-T11, Power Gen 2010
Module 4 Smart Grid Implementation Issues
PQube vs. X (instrument from competitors)
PV Solar Projects.
Nlyte for Colocation Providers
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
Recorded Presentation
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
2500 R Midtown Sacramento Municipal Utility District
Power Xpert® Power Monitoring solutions
2017 WECC JSIS Report March 21, 2017.
HARRY ALLEN TRANSFORMER REMEDIAL ACTION SCHEME (RAS)
Power Sensors Ltd – Introducing PQube 3 Power Sensors Ltd –
April 24, Study Group 1 A Regulatory Framework for Use of TV Channels by Part 15 Devices John Notor, Cadence Design Systems, Inc.
New features, more applications with PQube 3 Power Analyzers
PQube 3? MicroPMU? PSL Symposium 2016 Bangkok Thailand.
Waleed Iftikhar Michel Mabano
Components inverters Except where otherwise noted these materials are licensed Creative Commons Attribution 4.0 (CC BY)
Solar Energy Commercialization
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
easYgen-3000XT Series Training
PM9, PM9P and PM9C Power Meter
PowerLogic ION6200 Power and energy meter.
PowerLogic ION Enterprise
Power monitoring software
Presentation transcript:

New features, more applications with PQube 3 Power Analyzers PSL Symposium Prague Jun 2018

New features, more applications with PQube 3 Power Analyzers Data Centers UPS Monitoring Utilities grid operators, DER/PV integrators Utilities & commercial /industrial Manufacturing Healthcare facilities New product (summary) New features (summary)

Data Centers Problem solving: Explain, justify costly investments in design for reliability – during design and during operation Problem solving: measure & optimize power profile optimization up to four (4) 3-phase PDUs NEW ! Problem solving: Prevent PDU overloading (breaker trips) ---- Load shedding ---- colocation /shared hosting / in-house

Data Centers NEW Load shedding: CRAC = computer room air conditioning Firmware 3.7.0 Q3 2018 NEW Load shedding: Turn OFF CRAC units before the PDU overloads (circuit breaker trip) and Turn CRAC units back ON when the overall consumption is back within limits CRAC = computer room air conditioning

Data Centers How load shedding works Ex: 2 threshold load shedding Consumption (PDU load) CR AC #2 OFF Relay 2 Trigger threshold Hysteresis Relay 2 Return Threshold CRAC #1 OFF Hysteresis How load shedding works Ex: 2 threshold load shedding Watts Relay 1 Trigger threshold Relay 1 Return Threshold Up to 4 X 3-phase loads or up to 8 thresholds … Relay 1 Active Relay 2 Active

Data Centers Load shedding works with relays… which relays? RM8 – 8 relay output module Up to 2 modules …. 16 relays

Data Centers Impact of earthquake on specific racks/equipment: The “shake” is not identical from one rack to the other Detect seismic wave impact or mechanical shock impact – LOCALLY

Data Centers : who to sell to ? PDU RACKS UPS POC GENSET

Manufacturing: alarm & control New! RM8 + PQube 3 or PQube 3e 8 additional relays 1+8 = 9 relays New! PQube 3r PQube 3 with 3 additional relays 1+3 = 4 relays

Utilities: grid operators, DER/PV integrators Problem solving: insure generation performance remains in compliance with regulations during and after commissioning Voltage /VAR response Voltage/ frequency ride through Net /import /export energy Solar and environment conditions Grid stability : real time measurements, phasor measurements – > New! GRID ANALYZER

Utility Grid operators, DER/PV integrators

Monitoring UPS performance Problem solving: identify root cause of power outage Did the UPS work properly? NEW! : Input AND output power monitoring NEW! : assess UPS equipment performance = efficiency! Firmware 3.7.0 Q3 2018

Monitoring UPS performance With PQube 3e and VAT1-600! Option: Battery bank monitoring

Monitoring UPS performance

Utilities, oil/water treatment industries Problem solved: integration of PQube 3 analyzer with existing SCADA systems Communication protocol : DNP 3.0 (IEEE 1815-2012) Level 1 – polling data points Level 2 – alarm when value exceeds a dead band. (configured by the DNP3 client application) Level 3 – encryption (version 3.7.0) DNP3 opens door to larger bids…

Utilities and industries (Europe, Asia, South America) Problem solving: reduce time, training & personnel to prepare and review compliance reports EN50160 embedded reports Condensed summary Sent by email.. daily, weekly.. Compliant New in 3.6.X ! Non compliant

New feature : EN 50160 embedded reports EN50160 limit (100%) 95% of the variations above the nominal voltage compliance margin 95% of the variations below the nominal voltage Pass/fail status

New feature : EN 50160 embedded reports EN50160 limit (100%) Individual harmonic compliance margin Here, 95 % of the time Harmonic rank 15 is below 22% of the max compliance threshold Individual harmonic pass/fail status

Utilities and industry Problem solving: Reduce time, training & personnel to prepare reports The embedded ITIC graph Firmware 3.7.0 release Q3

Utilities and industry verticals Firmware 3.7.0 release Q3 A great sag/swell event overview sent from your PQube 3 ! Quickly identify the events out of the compatibility curve. Delivered with the embedded report: Daily, weekly, monthly

Healthcare facilities

Healthcare facilities > Power monitoring > disturbance detection > operational environment monitoring New ! Vibration detection New in 3.6.X !

New products, new modules Summary PQube 3 : 32GB internal memory (Jan2018) Combination PMU and Power Analyzer : GridAnalyzer PQube 3 for control applications: PQube 3r Extension relay module : RM8

2kHz-150kHz Conducted emissions New in firmware 3.6.x (3.6.3 released Apr 2018) 2kHz-150kHz Conducted emissions Change to balanced sensitivity map Separate color maps sensitivity for 2-9kHz and 8-150kHz GIF graphs

Improvements: 2kHz-150kHz color map 3-Phase view Phase by phase view

New features Summary EN 50160 embedded reports Protocol DNP3 2kHz ~ 150kHz conducted emissions: > Phase by phase color maps (optional) > Separate sensitivity for 2-9kHz and 8-150kHz Vibration detection and recording Analog channels configurable gain and now configurable offset

This was “what’s new” Thank you! Questions , please…