Heparin immobilization reduces thrombogenicity of small-caliber expanded polytetrafluoroethylene grafts  Jan M.M. Heyligers, MD, Hence J.M. Verhagen,

Slides:



Advertisements
Similar presentations
Endothelial cell seeding reduces thrombogenicity of Dacron grafts in humans Per Örtenwall, MD, PhD *, Hans Wadenvik, MD, PhD **, Jack Kutti, MD, PhD **,
Advertisements

Professionalism and the work-life balance Thomas S. Huber, MD, PhD Journal of Vascular Surgery Volume 60, Issue 4, Pages (October 2014) DOI:
Without prejudice Journal of Vascular Surgery
Paclitaxel coating on the terminal portion of hemodialysis grafts effectively suppresses neointimal hyperplasia in a porcine model  Insu Baek, PhD, Jinsun.
A heparin-bonded vascular graft generates no systemic effect on markers of hemostasis activation or detectable heparin-induced thrombocytopenia–associated.
Novel thromboresistant materials
Prospective evaluation of postimplantation syndrome evolution on patient outcomes after endovascular aneurysm repair for abdominal aortic aneurysm  Eleni.
Development of a “leak-proof,” knitted Dacron vascular prosthesis
Preformed confluent endothelial cell monolayers prevent early platelet deposition on vascular prostheses in baboons  Peter A. Schneider, MD, Stephen R.
The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair  Frederico Bastos Gonçalves, MD, Hence J.M.
Lise Pyndt Jørgensen, MD, Torben V. Schroeder, MD, DMSc 
Results of endovascular repair of infrarenal aortic aneurysms using the Endurant stent graft  Herman J.A. Zandvoort, MD, PhD, Frederico Bastos Gonçalves,
Howard E. Katzman, MD, Robert B. McLafferty, MD, John R
Current state in tracking and robotic navigation systems for application in endovascular aortic aneurysm repair  Quirina M.B. de Ruiter, MSc, Frans L.
The current position of precuffed expanded polytetrafluoroethylene bypass grafts in peripheral vascular surgery  Jasper van der Slegt, MD, Stijn L. Steunenberg,
Boudewijn L. Reichmann, MD, Jorinde H. H. van Laanen, MD, Jean-Paul P
Christopher D. Owens, MD, MSc  Journal of Vascular Surgery 
Critical parameter of burst pressure measurement in development of bypass grafts is highly dependent on methodology used  Sandip Sarkar, MA, MRCS, Claire.
D. A. Lewis, PhD, R. C. Lowell, MD, R. A. Cambria, MD, P. C
Experimental colonization of an expanded polytetrafluoroethylene vascular graft with Staphylococcus aureus: A quantitative and morphologic study  Olivier.
The effects of carmeda bioactive surface on human blood components during simulated extracorporeal circulation  Robert L. Korn, MD, PhD, Carol A. Fisher,
Christopher D. Owens, MD, MSc  Journal of Vascular Surgery 
Michael A. Rosenbaum, MD, Keiko Miyazaki, MD, Scott M. Colles, Linda M
Paclitaxel coating of the luminal surface of hemodialysis grafts with effective suppression of neointimal hyperplasia  Insu Baek, MS, Cheng Zhe Bai, PhD,
Migration of the ringed ePTFE graft into the small intestine
Enhanced intimal thickening of expanded polytetrafluoroethylene grafts coated with fibrin or fibrin-releasing vascular endothelial growth factor in the.
The first operation on the profunda femoris artery
Impaired graft healing due to hypercholesterolemia is prevented by dietary supplementation with α-tocopherol  Keiko Miyazaki, MD, Scott M. Colles, PhD,
Confluent durable endothelialization of endarterectomized baboon aorta by early attachment of cultured endothelial cells  Peter A. Schneider, MD, Stephen.
Frederico Bastos Gonçalves, MD, PhD, Klaas H. J. Ultee, BSc, Sanne E
Without prejudice Journal of Vascular Surgery
Protecting the brain and spinal cord
In vivo suppression of vein graft disease by nonviral, electroporation-mediated, gene transfer of tissue inhibitor of metalloproteinase-1 linked to the.
The fate of an endothelium layer after preconditioning
Piet Borgdorff, PhD, Rogier H. van den Berg, MsC, Martijn A
Circulating inflammatory cells are associated with vein graft stenosis
Revascularization surgery for penile calciphylaxis
Frederik H. W. Jonker, MD, Hence J. M. Verhagen, MD, PhD, Peter H
Inhibition of neointimal hyperplasia in a sheep model of dialysis access failure with the bioabsorbable Vascular Wrap⁎ paclitaxel-eluting mesh  Ted R.
Paul Berger, MD, Dennis de Bie, MaNP, Frans L
Five-Year Patency Rates for Heparin-Bonded Expanded Polytetrafluoroethylene Femoropopliteal Bypass Grafts vs ePTFE Grafts Without Heparin  Russell H.
Bovine carotid artery biologic graft outperforms expanded polytetrafluoroethylene for hemodialysis access  Isibor Arhuidese, MD, MPH, Thomas Reifsnyder,
A comparison of tibial artery bypass performed with heparin-bonded expanded polytetrafluoroethylene and great saphenous vein to treat critical limb ischemia 
Activated coagulation during open and endovascular abdominal aortic aneurysm repair  Lars Englberger, MD, Hannu Savolainen, MD, PhD, Peter Jandus, Matthias.
Frederik H. W. Jonker, MD, Hence J. M
A multicenter comparison between autologous saphenous vein and heparin-bonded expanded polytetrafluoroethylene (ePTFE) graft in the treatment of critical.
Rapamycin-coated expanded polytetrafluoroethylene bypass grafts exhibit decreased anastomotic neointimal hyperplasia in a porcine model  Catherine Cagiannos,
The durability of endovascular repair of para-anastomotic aneurysms after previous open aortic reconstruction  Jan A. Ten Bosch, MD, Evert J. Waasdorp,
Reply Journal of Vascular Surgery
Norman A. Shoenfeld, M. D. , Jens Eldrup-Jorgensen, M. D
Unknown pages in the history of vascular stent grafting
Jip L. Tolenaar, MD, Jasper W. van Keulen, MD, Vanessa J
Polyurethane vascular prostheses decreases neointimal formation compared with expanded polytetrafluoroethylene  Marc G. Jeschke, MD, Valentin Hermanutz,
Perioperative asymptomatic cardiac damage after endovascular abdominal aneurysm repair is associated with poor long-term outcome  Tamara A. Winkel, MD,
Complement activation by synthetic vascular prostheses
Small-caliber heparin-coated ePTFE grafts reduce platelet deposition and neointimal hyperplasia in a baboon model  Peter H Lin, MD, Changyi Chen, MD,
Sandra A. Cornelissen, MD, MSc, Hence J
Long-term dilatation of polyester and expanded polytetrafluoroethylene tube grafts after open repair of infrarenal abdominal aortic aneurysms  Peter L.
Acute management of aortobronchial and aortoesophageal fistulas using thoracic endovascular aortic repair  Frederik H.W. Jonker, MD, Robin Heijmen, MD,
Lipid uptake in expanded polytetrafluoroethylene vascular grafts
Thrombogenesis of different cell types seeded on vascular grafts and studied under blood-flow conditions  Paul Ph.A.Hedeman Joosten, MD, Hence J.M. Verhagen,
Heparin-bonded expanded polytetrafluoroethylene femoropopliteal bypass grafts outperform expanded polytetrafluoroethylene grafts without heparin in a.
FT04. “The Vein Is Screwed” Proof of Concept of the VeinScrew: A New Percutaneous Venous Closure Device  Doeke Boersma, MD, Frans Moll, MD, PhD, Gert Jan.
Regarding “High spatial resolution magnetic resonance imaging of cystic adventitial disease of the popliteal artery”  Emilie A.M. Weimar, BSc, Patrick.
One-year multicenter results of 100 abdominal aortic aneurysm patients treated with the Endurant stent graft  Jasper W. van Keulen, MD, Jean-Paul P.M.
The care of the patient with vascular disease
Left common iliac artery to inferior vena cava abdominal wall arteriovenous graft for hemodialysis access  Nader Zamani, BS, Javier E. Anaya-Ayala, MD,
Prospective randomized study evaluating an absorbable cyanoacrylate for use in vascular reconstructions  Alan B. Lumsden, MD, Eugene R. Heyman, PhD  Journal.
Paul Berger, MD, Dennis de Bie, MaNP, Frans L
John F. Eidt, MD, Elliot Chaikof, MD, PhD, Anton N. Sidawy, MD, MPH 
Presentation transcript:

Heparin immobilization reduces thrombogenicity of small-caliber expanded polytetrafluoroethylene grafts  Jan M.M. Heyligers, MD, Hence J.M. Verhagen, MD, PhD, Joris I. Rotmans, MD, PhD, Cees Weeterings, Msc, Philip G. de Groot, PhD, Frans L. Moll, MD, PhD, Ton Lisman, PhD  Journal of Vascular Surgery  Volume 43, Issue 3, Pages 587-591 (March 2006) DOI: 10.1016/j.jvs.2005.10.038 Copyright © 2006 The Society for Vascular Surgery Terms and Conditions

Fig 1 The newly developed ex vivo perfusion system using a cuff at a constant pressure of 45 mm Hg to ensure blood flow. Blood is aspirated through the graft with a constant flow of 20 mL/min, resulting in a shear rate of 74/s. Journal of Vascular Surgery 2006 43, 587-591DOI: (10.1016/j.jvs.2005.10.038) Copyright © 2006 The Society for Vascular Surgery Terms and Conditions

Fig 2 Scanning electron microscopy showing platelet adhesion and fibrin deposition (arrows) on the untreated Gore-Tex expanded polytetrafluoroethylene vascular graft perfused for 6 minutes with nonanticoagulated whole blood (A) and no such adhesion or deposition on the Gore-Tex graft treated with Carmeda BioActive Surface technology (B). Representative pictures of a single volunteer are shown. Journal of Vascular Surgery 2006 43, 587-591DOI: (10.1016/j.jvs.2005.10.038) Copyright © 2006 The Society for Vascular Surgery Terms and Conditions

Fig 3 Heparin immobilization reduces fibrin formation during ex vivo perfusions. Perfusions were performed in 10 volunteers by using both a noncoated and heparin-bonded graft in each volunteer. Serial samples were taken during perfusion, in which levels of fibrinopeptide A (FPA) were measured by enzyme-linked immunosorbent assay. Error bars indicate SEM. ePTFE, Expanded polytetrafluoroethylene. Journal of Vascular Surgery 2006 43, 587-591DOI: (10.1016/j.jvs.2005.10.038) Copyright © 2006 The Society for Vascular Surgery Terms and Conditions

Fig 4 Progression of prothrombin fragment 1 + 2 (F1+2) levels in the perfusate over time. There was no increase in F1+2 in the perfusate over time on either type of vascular graft, thus indicating that no measurable amount of thrombin was generated. Error bars indicate SEM. ePTFE, Expanded polytetrafluoroethylene. Journal of Vascular Surgery 2006 43, 587-591DOI: (10.1016/j.jvs.2005.10.038) Copyright © 2006 The Society for Vascular Surgery Terms and Conditions

Fig 5 Progression of the percentage of P-selectin–positive platelets (pos plts) in the perfusate over time. P-selectin expression on the perfused platelets did not increase over time on either graft surface, thus indicating that no measurable number of platelets was activated. Error bars indicate SEM. ePTFE, Expanded polytetrafluoroethylene. Journal of Vascular Surgery 2006 43, 587-591DOI: (10.1016/j.jvs.2005.10.038) Copyright © 2006 The Society for Vascular Surgery Terms and Conditions