嘉義長庚紀念醫院 放射診斷 科學術研討會紀錄 研討會名稱: Journal Reading 研討會名稱: Journal Reading 時間:民國 91 年 3 月 22 日 12 時 30 分 時間:民國 91 年 3 月 22 日 12 時 30 分 地點: X 光科 地點: X 光科 主持人:楊博堯、翁旭惠.
Special Imaging Techniques Chapter 6 Bushong. Dynamic Computed Tomography (DCT) Dynamic scanning implies 15 or more scans in rapid sequence within one.
tomos = slice, graphein = to write
Chapter 2 Stewart C. Bushong
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Conventional and Computed Tomography
Basic principles Geometry and historical development
Application of Cone Beam Computed Tomography Imaging to Dental and Maxillofacial Practice. ABSTRACT ID NO: IRIA-1162.
COMPUTED TOMOGRAPHY I – RAD 365 CT - Scan
Consultant Radiologist Prince Sultan Military Medical City
بسم الله الرحمن الرحيم.
Case Report # 1 Submitted by:James Korf, MS4 Faculty reviewer:Sandra Oldham, MD Date accepted:27 August 2014 Radiological Category:Principal Modality (1):
Evaluation of Multi-Slice Computed Tomography in Assessment of Cochlear Implant Electrode Position: A pictorial essay By:Fatemeh Nasri Tehran University.
Revision Dr Mohamed El Safwany, MD.. Liver CT Blood circulation in the liver comprises two major components: the hepatic artery and the portal vein. After.
Computed Tomography Q & A
Seeram Chapter 9: Image Manipulation in CT
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
Methods of Data Acquisition. General Methods of Data Acquisition Localizer scanning Step-and-shoot (axial) scanning Helical scanning.
Image Quality The capacity to define, measure, and assess image quality is a primarily responsibility of a CT Technologist.
Intended learning outcome The student should learn at the end of this lecture procedures of CT pulmonary angiography.
Part No...., Module No....Lesson No
CT ANGIOGRAPHY Dr Mohamed El Safwany, MD. Intended learning outcome The student should learn at the end of this lecture CT IMAGE OF THE BLOOD VESSEL OPACIFIED.
TISSUE HARMONIC IMAGING (THI)
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Imaging of Focal Nodular Hyperplasia: A Review
INTRODUCTION A major limitation of C-arm fluoroscopy is the inability to capture radiographic images in more than one anatomical plane at a time. The G-arm.
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
Basic Principles of CT Scanning. CT CT - Computed Tomography CAT Scan - Computerized Axial Tomography.
Background Trauma Patients undergo an initial, “on admission” CT scan which includes: Non contrast brain Arterial phase full body scan Portal venous phase.
CT Multi-Slice CT.
Computed Tomography Basics
Figure 1 Image reconstruction in prospectively ECG-triggered high-pitch spiral coronary CT angiography using dual-source CT. The entire period of data.
Impact of Obesity on Medical Imaging and Image-Guided Intervention
Multiple single sections Turbo FLASH MR arterial portography in the detection of hepatic neoplasms  Hidemasa Uematsu, Hiroki Yamada, Norihiro Sadato,
CT PRINCIPLES AYMAN OSAMA.
Sunday Case of the Day Physics
Volume 146, Issue 1, Pages e1 (January 2014)
Andrew D. Hardie, MD Carlo N. De Cecco, MD
Gastric Schwannoma - A Rare Cause of Dyspepsia
Advantages of spiral CT
Dig a Little Deeper: Adrenal
CT of the abdomen.
Henderson JM, Moslim MA, Knox MK, Cowan NC
Two lesions are seen within the lateral segment of the left lobe of the liver (yellow arrows). They appear mildly hyperintense on T2 images and mildly.
An avidly enhancing mass is seen in the left lobe on arterial-phase imaging. It is slightly hyperintense on portal-venous-phase imaging but overall isointense.
Volume 146, Issue 1, Pages e1 (January 2014)
Desiree E. Morgan, John C. Texada, Cheri L. Canon, Mark E
Strategies for Reducing Radiation Exposure From Multidetector Computed Tomography in the Acute Care Setting  Aaron Sodickson, MD, PhD  Canadian Association.
Imaging Approach for Evaluation of Focal Liver Lesions
Inflammatory Pseudotumours in the Abdomen and Pelvis: A Pictorial Essay  Tony Sedlic, MD, Elena P. Scali, MD, Wai-Kit Lee, MD, Sadhna Verma, MD, Silvia.
Annalisa K. Becker, MD, FRCPC, David K. Tso, MD, Alison C
Basic principles Geometry and historical development
Functional imaging in liver tumours
David J. Brenner, Maria A. Georgsson  Gastroenterology 
Imaging in Liver Malignancy
Magnetic resonance imaging of liver tumors
Riccardo Lencioni, Fabio Piscaglia, Luigi Bolondi 
Perspectives of Novel Imaging Techniques for Staging, Therapy Response Assessment, and Monitoring of Surveillance in Lung Cancer: Summary of the Dresden.
Dual-Energy Computed Tomography
The Role of Contrast-Enhanced Ultrasound in Guiding Radiofrequency Ablation of Hepatocellular Carcinoma  Andy K.W. Chan, MD, FRCPC, Chris Hegarty, MB,
C. In the hepatobiliary phase, the lesion shows hypointensity (arrow).
Presentation transcript:

嘉義長庚紀念醫院 放射診斷 科學術研討會紀錄 研討會名稱:Journal Reading 時間:民國 91 年 3 月 22 日 12 時 30 分 地點:X光科 主持人:楊博堯、翁旭惠 主講人:曾亮節 主題: Hepatic Imaging with multidetector CT 出席者:楊博堯、翁旭惠、曾亮節、馬智盈 出席率: 100 %

Hepatic Imaging with Multidetector CT Hoon Ji, MD, PhD ● Jeffrey D. McTavish, MD ● Koenraad J. Mortele, MD ● Walter Wiesner, MD ● Pablo R. Ros, MD, MPH RadioGraphics 2001; 21:S71–S80

Introduction Multidetector computed tomography (CT) multiple-row detector array instead of the traditional single-row detector array used in spiral CT allows scanning four to eight times faster than scanning with spiral CT emphasizes the role of multidetector CT in the diagnosis and staging of hepatic pathologic conditions.

Parameters for Acquisition of Hepatic Images Collimation Collimation should be tailored to the purpose of the study ↓collimator width ↓thickness ↑spatial resolution ↑Image Noise ↓decreased length of coverage ↑

1mm collimation 1.25mm section thickness 2.5mm collimation 5mm section thickness

Pitch

there are two distinct versions of pitch, 1) whether the entire beam collimation is considered or 2) the “detector” collimation (ie, beam/4) is used. 10mm/rotation 10mm collimation width 10mm/rotation 2.5mm detector collimation Pitch = 1 Pitch = 4

The selection of pitch for multidetector CT is affected by such factors as the required length of coverage, reconstructed section thickness, and image noise

↑Spatial resolution ↓Contrast resolution ↓Collimation ↓Reconstructed section thickness ↑Pitch ↑Noise ↓Contrast resolution

Thus, the most appropriate choice of scanning parameters is dependent on the imaging problem under consideration. For hepatic CT, because both good spatial resolution and good contrast resolution are required, a practical approach is to use relatively narrow collimation, increasing the pitch as needed to cover the entire liver.

Reconstruction Interval The choice of reconstruction interval is dependent on the clinical problem for which the study is being performed. ↓Reconstruction Interval ↑Z-axis resolution ↓Z-axis coverage If multiplanar reconstructions is expected, a small reconstruction interval with overlapping sections is advantageous overlapping reconstructions have been shown to improve the detection of hepatic metastases.

Contrast Media For liver imaging, the most important patient-related factor that affects the magnitude of hepatic contrast enhancement is body weight. the increased use of nonaxial reconstructions and the potential for high-attenuation oral contrast medium to degrade the reconstructions. In these situations, water is recommended as an oral contrast agent.

Timing of Scanning The timing of peak aortic and hepatic contrast enhancement is primarily dependent on the rate of injection The time to peak aortic enhancement is determined from the resultant time attenuation curve and is used to calculate the scanning delay. The scanning delay can also be accurately timed with a bolus tracking software program

Triple-pass technique, multidetector CT can be used to image during three distinct hepatic circulatory phases First phase (arterial phase) - displays the hepatic arterial system, though it may be too early to see some hypervascular neoplasms Arterial phase

venous system and is labeled the parenchymal or portal vein inflow Second phase - initial opacification of the portal venous system and is labeled the parenchymal or portal vein inflow phase. - The enhancement of hypervascular neoplasms is maximized during this - In both primary and metastatic hypervascular neoplasms, approximately 30% more lesions are detectable during this phase than during the later portal venous phase Parenchymal phase

Multiple metastases in a 59-year-old woman Multiple metastases in a 59-year-old woman. (a) Arterial-phase image shows indistinct, low-attenuation, atypical metastatic carcinoid tumors. (b) Image obtained during the late parenchymal phase allows clearer identification of multifocal, low-attenuation masses in both hepatic lobes. (c) Image obtained during the hepatic venous phase shows maximal parenchymal enhancement. Demarcation of the tumors is less distinct than that on the parenchymal-phase image.

- enhancement of background Third phase (portal venous phase) - also known as the hepatic venous phase, the hepatic veins are enhanced, - enhancement of background hepatic parenchyma is maximized. Porto-venous phase Hepatic scanning during three distinctive phases of enhancement may provide information useful for characterization of lesions.

Figure 5. Small hepatocellular carcinoma. (a) Arterial-phase image shows an enhancing mass in the liver (arrow). (b) Image obtained during the parenchymal phase clearly shows the mass. (c) On the image obtained during the hepatic venous phase, however, no definable mass is shown because the “temporal window” has passed.

Sample Protocol for four-Detector-Row CT of the Liver 30% nonionic contrast material (30 g iodine) is administered at a rate of 4 mL/sec for 25 seconds. Three passes are performed, one each during the = =arterial phase (20 seconds after injection of contrast medium), = parenchymal phase (35 seconds after the initiation of injection), = hepatic venous phase (60 seconds after the start of injection).

Clinical Utility of Multidetector CT Improved Detection of Lesions - The shorter imaging times of multidetector CT allow imaging during periods of more intense enhancement, as well as more precise imaging during specific phases of enhancement - with multidetector CT there may be less respiratory misregistration and greater z-axis resolution.

CT of the liver can be performed routinely with very thin collimation, yielding greater conspicuity of small lesions for better detection of lesions Use of 2.5-mm-thick sections ↑46% compared with 10-mm ↑18% compared with 5-mm

Three-dimensional Imaging With the rapid scanning ability of multidetector CT, - We have found that image quality in reconstructed sagittal, coronal, or curved planes is excellent in most cases. - Such unique imaging approaches may ultimately improve lesion detection, characterization, and surgical planning

Limitations of Multidetector CT the image files may be extraordinarily large, soft-copy viewing at a workstation is the most efficient way to review these large data sets timing of scanning becomes more critical as the increased speed of multidetector CT narrows the “temporal window” for desirable phase of enhancement. an increased radiation dose, ↑mAS

Conclusions Multidetector CT allows highly precise imaging during three (or more) distinct phases of hepatic enhancement. Optimal acquisition timing, in combination with thinner collimation, permits improved lesion detection and will also probably improve characterization of lesions. new era of CT-based three-dimensional imaging of the abdominal viscera is becoming a reality.