HOW NAD - RRA duct diffuser

Slides:



Advertisements
Similar presentations
3 Ft. 27 Ft. Sketch B Horizontal 15 degree Vertical 0 Effect of Horizontal Vanes Setting.
Advertisements

CAT Practice Excellence. Question One You are to explore the sequence of numbers given by the rule: 2n 2 + 3n - 1 Find the rule for the difference between.
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
HVAC CONTROLS (See section 18.9)
AIR CONDITIONING ACCESSORIES
Innovative Solutions to Improve Comfort & Efficiency NEX and PLAY.
Enabling Wellbeing 1. Halton - Enabling Wellbeing Halton was established in 1969 Family owned company, operating in 23 countries. We are passionate about.
Simple installation. VAV SYSTEM FEATURES ( One Of Many Types ) Electric or Pneumatic or Digital Controls “In Duct” &/or “At Diffuser” Locations Pressure,
Chilled Beam Presentation
The Application of Vertically-Mounted Jet Fans in Ventilation Shafts for a Rail Overbuild Richard Ray, Mark Gilbey and Praveen Kumar PB Americas, Inc.
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Airflow Properties & Measurement
1 Meeting ASHRAE Fundamentals, Standard 55 & 62.1 with Chilled Beams Displacement Ventilation.
Trevor Thompson Senior Project II Vermont Technical College Spring 2011.
Backdraft Dampers. Backdraft Damper Training Application Backdraft dampers allow air to flow in one direction only and prevent unwanted (hot/cold outside.
Lindab Pascal - Simplified VAV solution with full potential...
ARCH-4372/6372 HVAC Distribution & Sizing HVAC Distribution Systems
Announcement Course Exam October 11 th (Tuesday) In class: 90 minutes long Examples are posted on the course website.
(material to be checked with local legislation)
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Plenum Runs Plenum Runs. Plenum Run Usually located in the attic or basement. Run in any location accessible for attachment of supply tubing. More economical.
Chapter 11: Space Air Diffusion Conditioned air is normally supplied to air outlets at velocities much higher than would be acceptable in the occupied.
MECHANICAL ENGINEERING FOR SYSTEM BALANCE ASHRAE MEETING 2/15/2007 NORTHERN NEVADA CHAPTER 126 MATT BRENNAN, TBE.
Drafts and Duct System Sizing
A Damper for every Duct! Young Regulator Product Line Think Young!
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
ADS / PHX SERIES SYSTEMS DESIGN
Lindab | we simplify construction - Flexibility when it is needed... Premum & Premax With unique JetCone and Angled Nozzles Patent pending solution.
Testing Fan Filter Units
1 System Design. 2 Primary Detection Secondary Detection Standards Pipe Design.
Are you sitting… well? About comfort,. As a responsible of occupant comfort, we all have a duty to make a careful selection of appropriate diffusers and.
3.4 Equal friction method This method of sizing is used for supply, exhaust and return air duct system and employs the same friction lose per foot of length.
Objectives Finish with Duct Design Review the design procedure and explain the theoretical background Diffuser Selection Answer question related to the.
What makes up a Unico System
Objectives - Air Distribution Systems -Diffuser selection -Duct design Reading Assignment: Chapter 18.
Objectives Air Distribution Systems -Diffuser selection -Duct design.
Duct Design Basics Lesson 4 Manual D Primer. Available Static Pressure 4.4.
Lesson 1 Friction Chart Primer 1.3 Friction Chart.
Objectives Finish heat exchangers Air Distribution Systems
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Space Air Diffusion. Fundamentals  Objectives – thermal comfort and indoor air quality – even space air conditions – acceptable air cleanliness – acceptable.
Learning, our way DUCT DESIGN (material to be checked with local legislation) Daikin Europe, Consulting sales section.
Under floor heating Designing underfloor heating (UFH) system must always comply with the system suppliers instructions.
HVAC DUCT CONSTRCTION EXAMPLES
DESIGN OF SHELL AND TUBE HEAT EXCHANGER
Wega & Wega Power chilled beams
Maria’s Restaurant Chapter 3 Section 13
HOW SAL 35 - Linear diffuser
CHAPTER 11 -Hangers & Supports -Outside ducts
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
The influence of wind load on a suspended fiber optic cable
Objectives Finish with Exchangers - Start Air Distribution Systems
Maria’s Restaurant Chapter 3 Section 12
Introduction – Who am I? Environmental Project Manager – Trident Technical College Mechanical Engineer Licensed Builder South Carolina Accredited Commercial.
Maria’s Restaurant Chapter 4 Section 14
HOW NAD - RDD duct diffuser
Presented by Dan Int-Hout, Chief Engineer ASHRAE Fellow Life Member
Technician’s Guide and Workbook for Zoning Section 3: Single Zone Airflow Balancing and Thermostat Location.
Objectives Finish with Exchangers - Start Air Distribution Systems
Objectives Finish with Duct Design Diffuser Selection
Technician’s Guide and Workbook for Zoning Section 1: Introduction
Objectives Finish with heat exchangers (ch.11)
Zoning Load Calculations
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Mandatory Design Requirements
FBE03: Building Construction & Science
Objectives Duct Design AND Diffuser Selection.
Objectives Duct Design AND Diffuser Selection.
Maria’s Restaurant Chapter 3 Section 12
Click to see each answer.
Presentation transcript:

HOW NAD - RRA duct diffuser

RRA Selection Slotted duct diffuser Ideal for open ceilings HOW NAD - RRA duct diffuser RRA Selection Slotted duct diffuser Ideal for open ceilings Maximum installation height. Eccentric rollers Nozzle rollers Installation height between 14 ft (4,3m) and 30 ft (9 m) Maximum installation 14 ft (4,3 m)

RRA Suspension Threaded rods Rail HOW NAD - RRA duct diffuser RRA Suspension Threaded rods Rail Same type of suspension for other duct diffusers (RDD) Cables Wall mount

HOW NAD - RRA duct diffuser Blends with structure

Selection steps Determine placement of ducts Reducer or damper HOW NAD - RRA duct diffuser Selection steps Determine placement of ducts Reducer or damper Determine the Ø Determine airflow per meter of slots Determine the number of slots

Sample Calculation Zone 1 : 4160 m3/h (2450 cfm) HOW NAD - RRA duct diffuser Sample Calculation Zone 1 : 4160 m3/h (2450 cfm) Zone 2 : 1232 m3/h (725 cfm) Height of underside of duct : 4 m

Example of layout Create a layout of the ducts Reducer or damper HOW NAD - RRA duct diffuser Example of layout Create a layout of the ducts Reducer or damper Determine the Ø Determine the airflow Determine the number of slots

Recommendations for direct connection HOW NAD - RRA duct diffuser Recommendations for direct connection Create a layout of the ducts Reducer or damper Determine the Ø Determine the airflow Determine the number of slots

Recommendations for direct connection HOW NAD - RRA duct diffuser Recommendations for direct connection Create a layout of the ducts Reducer or damper Determine the Ø Determine the airflow Determine the number of slots

Recommendation for the connection between NAD and spiral duct HOW NAD - RRA duct diffuser Recommendation for the connection between NAD and spiral duct Create a layout of the ducts Reducer or damper Determine the Ø Determine the airflow Determine the number of slots The supply duct exceed the wall an exact length of 2’’1/4 (58 mm)

Optimal layout The RRA covers entirely the zone 5m HOW NAD - RRA duct diffuser Optimal layout Create a layout of the ducts Reducer or damper Determine the Ø Determine the airflow Determine the number of slots The RRA covers entirely the zone 5m

RRA rules Create a layout of the ducts Register on last section HOW NAD - RRA duct diffuser Create a layout of the ducts Reducer or damper Determine the Ø Determine the airflow Determine the number of slots RRA rules Register on last section Reducer or damper every 25 ft : every 5 active sections Register Reducer Damper

Diameter selection Create a layout of the ducts Reducer or damper HOW NAD - RRA duct diffuser Diameter selection   Create a layout of the ducts Reducer or damper Determine the Ø Determine the airflow Determine the number of slots Donner Ductolator

Selection of Diameter Zone 1 : composed of 2 sections section n° 1 : HOW NAD - RRA duct diffuser Selection of Diameter Create a layout of the ducts Reducer or damper Determine the Ø Determine the airflow Determine the number of slots Zone 1 : composed of 2 sections section n° 1 : - 4 x Ø 556 mm section n° 2 : - 4 x Ø 403 mm Zone 2 : composed of 1 section - 4 x Ø 353 mm

Create a layout of the ducts Reducer or damper Determine the Ø HOW NAD - RRA duct diffuser Create a layout of the ducts Reducer or damper Determine the Ø Determine the air flow per meter of slots Determine the number of slots    

An active duct typically has 1300 mm long slots HOW NAD - RRA duct diffuser An active duct typically has 1300 mm long slots Create a layout of the ducts Reducer or damper Determine the Ø Determine the airflow per meter of slots Determine the number of slots    

Create a layout of the ducts Reducer or damper Determine the Ø HOW NAD - RRA duct diffuser     Create a layout of the ducts Reducer or damper Determine the Ø Determine the air flow per meter of slots Determine the number of slots Clique sur image pour agrandir

Codification of RRA on plans HOW NAD - RRA duct diffuser Codification of RRA on plans Airflow TAG DIFFUSER RRA-A 101 l/s 2 DFR Start of NAD section Nb of slots Air pattern RRA-A 101 l/s 2 DFR RRA-A 101 l/s 2 DFR 2 Cliquer sur image pour agrandir 3 3 3 3 2 2 2 When a duct passes a partition (or a wall), don’t forget to use a collar Example of collar

NAD Technical Spec Chart HOW NAD - RRA duct diffuser NAD Technical Spec Chart Tableau NAD Specifications RRA Identification Brand Model Airflow Ceiling height Height below the duct Room Temp in winter Room R.H. % in winter Temp. in duct In summer Tempin duct in summer Notes RRA-A NAD Klima RRA 1, 2, 3,4,5,6,7 RRA-B RRA-C 1, 2, 3,4,5,6, 7 RRA-D 1, 2, 3,4,5, 6,7 Note : 1 – 3/8 threated rod will be supplied by contractor. 2 – The color of the diffuser must be selected from the RAL chart , as well the colour of the rollers from our standard colors (withe, black, creme). 3 – Air pattern adjusted and balanced in factory according to plan 4- The aluminium suspension rails will be painted the RAL color chosen and supplied by the manufacturer. 5- The rod covers will be painted the RAL color chosen and supplied by the manufactuer. 6- The ducts will be acoustically insolated by the manufacturer. 7- Starter flange included

Horizontal distance travelled by the air jet HOW NAD - RRA duct diffuser Simulation graphics Number of slots Air jet velocity Airflow rate per of slots Vertical distance travelled by the air jet before reaching the selected air speed Horizontal distance travelled by the air jet Vertical penetration of air jet Temperature differential in cooling

Codification HOW NAD - RRA duct diffuser Cliquer sur image pour aggrandir

Specifications Available online In word format www.nadklima.com HOW NAD - RRA duct diffuser Specifications Available online In word format www.nadklima.com