Mounting Zone Edge and Profile Tolerance Change on EPA2017 Inlets CEAF Type: Change Approval Request Technical Configuration(s) Affected: D313029BX03, D563025BX03 , D103016BX03 Engine Family Affected: B6.7, L9, X15 Market(s) Impacted: On-Highway. Anticipated Production Date (mm/yy): 03/2017 Option(s) Affected: PE0107200, PE0107400, PE0948500, PE0948600, PE0948700, PE0948800, PE0953200, PE0953300, PE0953400, PE0953500
Change Summary Due to manufacturing capability and limitations, CES is proposing a change to the inlet Mounting Zone edge location and profile tolerance. Remove the profile tolerance callout completely Change the “tube inlet to heat shield edge” dimension to specify a maximum dimension (see slides 3 to 6 for print detail). The change is to be implemented via deviation until P-phase prints are available with the above dimensions. Configurations Impacted: All EPA2017 Horizontal HD and MD systems. Expected Installation Impact to OEMs: Minor to none.
Print Detail (Side Inlet 10SS shown) X= 58.1 MAX
Print Detail (End Inlet 10SS shown) X= 114.8 MAX X= 118.8 MAX
Print Detail (Side Inlet 13SS shown) X= 58.3 MAX
Print Detail (End Inlet 13SS shown) X= 136.0 MAX X= 140.0 MAX
Summary Table for all affected Configurations Aftertreatment Size Inlet Type New Dimension X (see previous slides) 10SS End Inlet – Spherical Marmon 114.8 MAX End Inlet – Standard Marmon 118.8 MAX Side Inlet 58.1 MAX 10MM 10LL 13SS 136.0 MAX 140.0 MAX 58.3 MAX 13MM