Comparison between pulse waveform analysis and thermodilution cardiac output determination in patients with severe pre-eclampsia  R.A. Dyer, J.L. Piercy,

Slides:



Advertisements
Similar presentations
Comparison of video-based learning and lecture-based learning for training of ultrasound-guided central venous catheterization: a randomized controlled.
Advertisements

P.A. Bothma, C.J. Schlimp  British Journal of Anaesthesia 
Human factors in anaesthesia: lessons from aviation
Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery  U. Fakler, MD, Ch. Pauli, MD, G. Balling, MD, H.P.
Five algorithms that calculate cardiac output from the arterial waveform: a comparison with Doppler ultrasound  J. Zhang, L.A.H. Critchley, L. Huang 
Comparison of cardiac outputs during major surgery using the Deltex CardioQ oesophageal Doppler monitor and the Novametrix-Respironics NICO: A prospective.
A. Butwick, G. Hilton, B. Carvalho  British Journal of Anaesthesia 
Why is the surgical high-risk patient still at risk?
J Bordes, P.E. Gaillard, G Lacroix, B Palmier 
Is comparison of changes in cardiac output, assessed by different methods, better than only comparing cardiac output to the reference method?  N.W.F.
The entrapped central venous catheter
Type of anaesthesia and patient quality of recovery: a randomized trial comparing propofol–remifentanil total i.v. anaesthesia with desflurane anaesthesia 
K.-Y. Ho, W Tay, M.-C. Yeo, H Liu, S.-J. Yeo, S.-L. Chia, N.-N. Lo 
Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage† 
Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb†,††  N.W.F. Linton, R.A.F. Linton  British Journal.
M. Klein, L. Minkovich, M. Machina, M. Selzner, V. N. Spetzler, J. M
Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients  F. Franchi, R.
Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery  M.O. Fischer, R. Avram, I. Cârjaliu, M. Massetti,
Reporting of method comparison studies: a review of advice, an assessment of current practice, and specific suggestions for future reports  A. Abu-Arafeh,
A.F. Kopman, C.A. Lien, M Naguib  British Journal of Anaesthesia 
Preoperative abnormalities in serum sodium concentrations are associated with higher in-hospital mortality in patients undergoing major surgery  M. Cecconi,
Prospective, randomized, controlled trial of thoracic epidural or patient-controlled opiate analgesia on perioperative quality of life  M. Ali, D.C. Winter,
A different use of visual analytic techniques in anaesthetics
M. Boutonnet, V. Faitot, A. Katz, L. Salomon, H. Keita 
O. Thom, D. M. Taylor, R. E. Wolfe, J. Cade, P. Myles, H. Krum, R
Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries    British Journal of Anaesthesia 
Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery.
The trend interchangeability method
C. Hällsjö Sander, M. Hallbäck, M. Wallin, P. Emtell, A. Oldner, H
Complete heart block during central venous catheter placement in a patient with pre- existing left bundle branch block  D Unnikrishnan, N Idris, N Varshneya 
Continuous and minimally invasive cardiac output monitoring by long time interval analysis of a radial arterial pressure waveform: assessment using a.
Continuous non-invasive cardiac output monitoring during exercise: validation of electrical cardiometry with Fick and thermodilution methods  Y.H. Liu,
Complications of peripheral nerve blocks
Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care  B. Bataille, M. Bertuit, M. Mora,
A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients†  J.R.C. Jansen, J.J. Schreuder,
J.-H. Schiff, N Russ, K Ihringer, C Heal, E Martin, A Walther 
Anaesthetists’ non-technical skills
Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states  S. Scolletta, S.M. Romano, B. Biagioli,
Successful intubation using retrograde trans-tracheal illumination after laryngoscope light source failure  J Hudson, M Vu, E Vu  British Journal of Anaesthesia 
Effect of temperature on fluidity of irrigation fluids
The output of two sevoflurane vaporizers in the presence of helium
Comparison of cardiac output measured by oesophageal Doppler ultrasonography or pulse pressure contour wave analysis  A. Caillard, E. Gayat, A. Tantot,
Ultrasound-guided central venous catheterization in the prone position
E. Saraceni, S. Rossi, P. Persona, M. Dan, S. Rizzi, M. Meroni, C. Ori 
Lung recruitment and positive airway pressure before extubation does not improve oxygenation in the post-anaesthesia care unit: a randomized clinical.
A.J. Butwick, L. Coleman, S.E. Cohen, E.T. Riley, B. Carvalho 
Validation of a measurement tool for self-assessment of teamwork in intensive care  J Weller, B Shulruf, J Torrie, R Frengley, M Boyd, A Paul, B Yee, P.
Postoperative visual loss after plastic surgery: case report and a novel continuous real- time video monitoring system for the eyes during prone surgery 
Arm-to-arm variation when evaluating neuromuscular block: an analysis of the precision and the bias and agreement between arms when using mechanomyography.
Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia  O. Mimoz, T. Benard, A. Gaucher, D. Frasca, B.
Ultrasound reduces the minimum effective local anaesthetic volume compared with peripheral nerve stimulation for interscalene block  A McNaught, U Shastri,
G.B. Drummond, B. Lafferty  British Journal of Anaesthesia 
Pulmonary blood volume measured by contrast enhanced ultrasound: a comparison with transpulmonary thermodilution  I.H.F. Herold, M.A. Soliman Hamad, H.C.
Validity of the 6 min walk test in prediction of the anaerobic threshold before major non- cardiac surgery  R.C.F. Sinclair, A.M. Batterham, S. Davies,
Chronic widespread pain, including fibromyalgia: a pathway for care developed by the British Pain Society  J. Lee, B. Ellis, C. Price, A.P. Baranowski 
Comparison of central venous and external jugular venous pressures during repair of proximal femoral fracture†  A.D. Leonard, C.M. Allsager, J.L. Parker,
Peripheral venous pressure as an alternative to central venous pressure in patients undergoing laparoscopic colorectal surgery  S.H. Kim, S.Y. Park, J.
Spinal anaesthesia for ambulatory arthroscopic surgery of the knee: a comparison of low-dose prilocaine and fentanyl with bupivacaine and fentanyl  A.S.
Management of the heartbeating brain-dead organ donor
Accuracy of impedance cardiography for evaluating trends in cardiac output: a comparison with oesophageal Doppler  E. Lorne, Y. Mahjoub, M. Diouf, J.
Reduction of vasopressor requirement by hydrocortisone administration in a patient with cerebral vasospasm  J.A. Alhashemi  British Journal of Anaesthesia 
A huffing manoeuvre, immediately before induction of anaesthesia, prevents fentanyl- induced coughing: a prospective, randomized, and controlled study 
Ability of esCCO to track changes in cardiac output†
D Anton, P Friederich  British Journal of Anaesthesia 
Predictor of fluid responsiveness in the ‘grey zone’: augmented pulse pressure variation through a temporary increase in tidal volume  J.J. Min, N.-S.
Effect of neuraxial anaesthesia on tumour progression in cervical cancer patients treated with brachytherapy: a retrospective cohort study  H Ismail,
Influence of shoulder position on central venous catheter tip location during infraclavicular subclavian approach  M Kang, H.-G. Ryu, I.-S. Son, J.-H.
Effect of preoperative multimedia information on perioperative anxiety in patients undergoing procedures under regional anaesthesia  H.A. Jlala, J.L.
H.A. Leather, P.F. Wouters  British Journal of Anaesthesia 
R. Parke, S. McGuinness, R. Dixon, A. Jull 
Presentation transcript:

Comparison between pulse waveform analysis and thermodilution cardiac output determination in patients with severe pre-eclampsia  R.A. Dyer, J.L. Piercy, A.R. Reed, G.W. Strathie, C.J. Lombard, J.A. Anthony, M.F. James  British Journal of Anaesthesia  Volume 106, Issue 1, Pages 77-81 (January 2011) DOI: 10.1093/bja/aeq292 Copyright © 2011 The Author(s) Terms and Conditions

Fig 1 Bland and Altman comparison between TD and LiDCOplus after central venous calibration. Bias: −0.58 litre min−1, 95% confidence interval: −0.77 to −0.39 litre min−1. Dotted lines show limits of agreement. British Journal of Anaesthesia 2011 106, 77-81DOI: (10.1093/bja/aeq292) Copyright © 2011 The Author(s) Terms and Conditions

Fig 2 Bland and Altman comparison between TD and LiDCOplus after peripheral venous calibration. Bias: −0.16 litre min−1, 95% confidence interval: −0.37 to 0.06 litre min−1. Dotted lines show limits of agreement. British Journal of Anaesthesia 2011 106, 77-81DOI: (10.1093/bja/aeq292) Copyright © 2011 The Author(s) Terms and Conditions