Commodity Data Center Design

Slides:



Advertisements
Similar presentations
SAN DIEGO SUPERCOMPUTER CENTER at the UNIVERSITY OF CALIFORNIA, SAN DIEGO Green Datacenter Initiatives at SDSC Matt Campbell SDSC Data Center Services.
Advertisements

Computer Room Requirements for High Density Rack Mounted Servers Rhys Newman Oxford University.
Data Center Design Issues Bill Tschudi, LBNL
Cooling Strategies for Small IT Rooms Presented by Jim Magallanes TechniCool Innovations Inc Upham Street Suite B-1, Broomfield.
Protective Packaging and Materials Handling
Commodity Data Center Design James Hamilton
Cooling Product Positioning
Cloud Computing Data Centers Dr. Sanjay P. Ahuja, Ph.D FIS Distinguished Professor of Computer Science School of Computing, UNF.
PG&E and Altera Data Center Energy Efficiency Project.
Chapter 7 Demand Management Learning Objectives After reading this chapter, you should be able to do the following: Understand the critical importance.
Where Does the Power go in DCs & How to get it Back Foo Camp James Hamilton web: blog:
©2008 Pearson Education, Inc., Upper Saddle River, NJ. All rights reserved. This material is protected under all copyright laws as they currently exist.
Return of the Large Data Center. Computing Trends Computing power is now cheap, power hungry, and hot. Supercomputers are within reach of all R1 universities.
02/24/09 Green Data Center project Alan Crosswell.
Cloud Computing Economics Ville Volanen
Architecture for Modular Data Centers James Hamilton 2007/01/17
Computer Room Experiences A medium sized tier-2 site view Pete Gronbech GridPP Project Manager HEPIX April 2012.
Learning Objectives Determine the need for warehouses and inventory management Identify the various types of warehouses Identify and describe the different.
24 x 7 Energy Efficiency February, 2007 William Tschudi
All content in this presentation is protected – © 2010 American Power Conversion Corporation InfraStruxure ™ Management Software Eduard Bodor Senior System.
Commodity Data Center Design
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
Architecture for Modular Data Centers James Hamilton 2007/01/08
Best Practices in HVAC Design/Retrofit
Microprocessors Chapter 3.
Mission Energy: Energy Efficient Cooling How Data Centre energy consumption and operating costs can be significantly reduced through readily available.
Chapter 3 Storage Systems
Strata IT Training Chapter 16 Green Networking. Green Servers Power Management –Power off monitor settings –Automatic server shutdown policy Rack mounted.
Lots of hype, little science But – lots of this hype is real, and there are many challenging engineering problems Initially, we focus on data centers:
Overview of Data Center Energy Use Bill Tschudi, LBNL
MH...CH LECT011 What is Material Handling? Materials handling is the science and art both involving the moving, packing and storing of substance.
Energy Efficient Data Centre Design
Computing Facilities CERN IT Department CH-1211 Geneva 23 Switzerland t CF CERN Computer Centre Consolidation Project Vincent Doré IT Technical.
Authors: William Tschudi, Lawrence Berkeley National Lab Stephen Fok, Pacific Gas and Electric Company Stephen Fok, Pacific Gas and Electric Company Presented.
Increasing DC Efficiency by 4x Berkeley RAD Lab
3.3 Radiation In cold countries, solar hot water systems are often used to heat a house. In a typical solar hot water system, water from a storage tank.
MH...CH LECT-021 SYSTEMS CONCEPT Adopting a materials handling systems from overall optimization point of view. Adopting a materials handling systems.
CERN - IT Department CH-1211 Genève 23 Switzerland t Power and Cooling Challenges at CERN IHEPCCC Meeting April 24 th 2007 Tony Cass.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
Kaeser Compressors, Inc.
1 PCE 2.1: The Co-Relationship of Containment and CFDs Gordon Johnson Senior CFD Manager at Subzero Engineering CDCDP (Certified Data Center Design Professional)
Renewable Distributed Generation and Public Water Supply Utilities CWWA/CTAWWA Fall Conference Paul R. Michaud, Esq. October 20, 2015.
Dell EMC Modular Data Centers
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
Overview: Cloud Datacenters II
OCP for Telco The challenge and the solution
The Data Center Challenge
Material handling Defined as the art and science of moving, packing and storing of substances in any form. Creation of time and place utility Movement.
Electrical Systems Efficiency
Greening Your Information Systems
CERN Data Centre ‘Building 513 on the Meyrin Site’
Data Center Service Brian Messenger 11/15/2016.
AS/RS (Automated Storage/Retrieval System)
Data Center Research Roadmap
Kaeser Compressors, Inc.
Supply Chain Management for Non Supply Chain Management Professionals
DISTRIBUTION AND DELIVERY
Closing the Gap to Free Cooling in the Data Center
IT Equipment Efficiency
Cloud Computing Data Centers
IT Equipment Efficiency
Where Does the Power go in DCs & How to get it Back
OCP for Telco The challenge and the solution
Architecture for Modular Data Centers
The key to comfort and efficiency for heating and air-conditioning
Direct Current (DC) Data Center
Cloud Computing Data Centers
The Greening of IT November 1, 2007.
Energy Efficiency for the Machine (the Gigafactory) that Makes the Machine March 9, 2018.
Presentation transcript:

Commodity Data Center Design James Hamilton 2007-10-08 JamesRH@microsoft.com http://research.microsoft.com/~jamesrh

Containerized Products Nortel Steel Enclosure Containerized telecom equipment Caterpillar Portable Power Rackable Systems Concentro 1,152 Systems in 40’ (9,600 cores/3.5 PB) Datatainer ZoneBox Rackable Systems Container Cooling Model Google WillPower Will Whitted Petabox Internet Archive Brewster Kahle Sun Project Black Box 242 systems in 20’ 1/21/2007

Cooling, Feedback, & Air Handling Gains Verari Intel Tighter control of air-flow increased delta-T and overall system efficiency Expect increased use of special enclosures, variable speed fans, and warm machine rooms CRACs closer to servers for tighter temp control feedback loop Container takes one step further with very little air in motion, variable speed fans, & tight feedback between CRAC and load Intel 1/21/2007

Shipping Container as Data Center Module Contains network gear, compute, storage, & cooling Just plug in power, network, & chilled water Increased cooling efficiency Variable water & air flow Better air flow management (higher delta-T) 80% air handling power reductions (Rackable Systems) Bring your own data center shell Just central networking, power, cooling, security & admin center Can be stacked 3 to 5 high Less regulatory issues (e.g. no building permit) Avoids (for now) building floor space taxes Political/Social issues USA PATRIOT act concerns & regional restrictions Move resources closer to customer (CDN mini-centers) Single customs clearance on import Single FCC compliance certification Distributed, incremental fast built mini-centers 1/21/2007

Manufacturing & H/W Admin. Savings Factory racking, stacking & packing much more efficient Robotics and/or inexpensive labor Avoid layers of packaging Systems->packing box->pallet->container Materials cost and wastage and labor at customer site Data Center power & cooling expensive consulting contracts Data centers are still custom crafted rather than prefab units Move skill set to module manufacturer who designs power & cooling once Installation design to meet module power, network, & cooling specs More space efficient Power densities in excess of 1250 W/sq ft Rooftop or parking lot installation acceptable (with security) Stack 3 to 5 high Service-Free H/W admin contracts can exceed 25% of systems cost Sufficient redundancy that it just degrades over time At end of service, return for remanufacture & recycling 20% to 50% of systems outages caused by Admin error (A. Brown & D. Patterson) 1/21/2007

Systems & Power Density Estimating datacenter power density difficult (15+ year horizon) Power is 40% of DC costs Power + Mechanical: 55% of cost Shell is roughly 15% of DC cost Cheaper to waste floor than power Typically 100 to 200 W/sq ft Rarely as high as 350 to 600 W/sq ft Modular DC eliminates impossible shell to power trade-off Add modules until power is absorbed 480VAC to container High efficiency DC distribution within High voltage to rack can save >5% over 208VAC Over 20% of entire DC costs is in power redundancy Batteries able to supply up to 12 min at some facilities N+2 generation at over $2M each Instead, use more smaller, cheaper data centers Eliminate redundant power & bulk of shell costs Resource equalization 1/21/2007

Where do you Want to Compute Today? Slides posted soon to: http://research.microsoft.com/~JamesRH 10/08/2007