Electrodes: 3 types Types: Micro electrode Depth & needle electrodes

Slides:



Advertisements
Similar presentations
Fig. 22-1a (p.629) A galvanic electrochemical cell at open circuit
Advertisements

Summary of Potentiometry:
7th Lecture Dimitar Stefanov. Recapping Three types electrodes are used for sensing of EMG signals: 1.indwelling (intramuscular) electrodes (single fiber.
Chapter 5-Webster Biopotential Electrodes
Biomedical Instrumentation
Electrode measuring principle
Electricity from Chemical Reactions
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
BIOMEDICAL INSTRUMENTATION
1 IV. Electrodes In order to measure biopotentials, we must convert the ionic activity of the excitable cells of interest to electrical signals. In order.
Section 11 Potentiometry. Potentiometric Electrodes Potentiometric electrodes measure: Activity not concentration Concepts to review: Activity and affect.
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
EMG ELECTRODES. Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles. EMG is performed.
Biopotential electrodes
Biopotential Electrodes III
Lecture 6 Dimitar Stefanov.
Electroplating By: Matthew Nerhing. What is Electroplating? Electroplating- It is the deposition of a thin layer of metal on a surface by an electrical.
POTENTIOMETRY 8th lecture
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
South Fork Instruments Advances in pH/ORP Measurement – Polymeric Sensors Presented by John Daly South Fork Instruments.
Biopotential Electrodes III. Electrodes Recording Stimulating.
IC Controls Quality Water Solutions for pH pH / ORP Conductivity Dissolved Oxygen Chlorine Standards R1.0 © 2004 IC CONTROLS Concerns.
Electroanalytical methods
Potentiometry and potentiometric measurements. potentiometer A device for measuring the potential of an electrochemical cell without drawing a current.
Read page D-64.
1. Blood or Fluid Analysis Using carried out in central labs with problems of time delay costs and potential misslabeling Drive toward more bedside or.
Chapter 7 Electrochemistry
Biomedical Sensors Dr. James A. Smith. What’s Important? Accuracy Operational Range Response Time Sensitivity Resolution Reproducibility.
Biomedical Electrodes, Sensors, and Transducers
OBJECTIVE Without reference, identify at least four out of six principles pertaining to the application of transducers related to patient care.
Water and its Properties CP Biology: Chapter 2. The Water Molecule needed by all living things – parts of cells, fluid around cells (humans 65% water)
THE ELECTROD AND REDOX POTENTIIALS.
Transmission of Nerve Impulses GHB 2004 Information is carried along a neurone as an electrical impulse.
LECTURE 7: Electrochemistry. Types of electrodes and their using. ass. prof. Yeugenia B. Dmukhalska.
Ch. 21 Potentiometry 1. General principles
PH meter Bushra mubarak. pH pH is defined as the negative logarithm of the hydrogen ion activity aH. Unit of measure which describes the degree of acidity.
BY Parmar Anjali Singh Sweta
BIO POTENTIAL ELECTRODES. ELECTRODES What is an electrode? Device that converts ‘ionic potentials’ into ‘electronic potentials’ They are employed to pick.
Electrolytic Cells. An electrolytic cell is an electrochemical cell that undergoes a redox reaction when electrical energy is applied. It is most often.
By Suhas Dhenge.  To study the electrical activity of individual cell microelectrodes are employed.  This type of electrode must be small with respect.
291 Electrochemistry: Redox Reactions Electrochemistry: Redox Reactions Dr. M. Sasvári: Medical Chemistry Lectures.
OBJECTIVES Describe the method for measurement of membrane potential
Blood Gas Analysis and Analyzer (BME Lab 2) Palestine Polytechnic University Engineering & Technology Collage Electrical &Computer Department Biomedical.
Electricity within the body lect.8
NOTES: 2.2 – Properties of Water
Oxidation-Reduction Reactions
Potentiometry and potentiometric measurements
Transport through the cell membrane
Electrolytic Cells.
Three types electrodes are used for sensing of EMG signals:
REFERENCE ELECTRODES CHAPTER 4
Ion-Selective Electrode (I.S.E.)
Physiologic signals Lecture 6.
ELECTRODE PROCESSES, THEIR BIOLOGICAL ROLE AND USE IN MEDICINE
Cell Membrane.
Communication Chapter 7:
Cells and Batteries.
Electrochemical Cells
Figure 5.1 Electrode-electrolyte interface The current crosses it from left to right. The electrode consists of metallic atoms C. The electrolyte is an.
Electrochemistry.
Biopotential electrodes
Electrolysis: driving chemical reactions by electricity
Components of bio-medical instrument system
Biopotential electrodes
Intellical Red-ROD technology
Circuit Components.
Biomedical Electronics & Bioinstrumentation
Cells.
Redox in Electrochemistry
Presentation transcript:

Electrodes: 3 types Types: Micro electrode Depth & needle electrodes Surface electrodes

Micro electrodes: Intra cellular electrodes Used to measure the potential near or within cell Features: Smaller dimension (0.5 to 5 microns) Types: Metallic Non metallic (Micropipet)

Metal microelectrode: Formed by electrolytically etching the tip of fine Tungsten or stainless steel Electropointing Coated with insulating material Chloriding the tip : reduce the impedance

Metal electrode:

Metal electrode – electrical equivalent:

Equivalent: EA – metal electrode-electrolyte potential at the microelectrode tip EB – Reference electrode – electrolyte potential EC – variable cell membrane potential RA – resistance of connecting wire RB – resistance of wire connected to reference electrode

Contd. Impedance of microelectrode is inversely proportional to the area of the tip & frequency. Zin of the amplifier should be high : if not, behaves like a high pass filter

Micropipet (Non metallic electrode): 1 micrometre Filled with electrolyte 3 M KCL

Micropipet – electrical equivalent:

Equivalent: EA – metal electrode-electrolyte potential at the microelectrode tip EB – Reference electrode – electrolyte potential EC – variable cell membrane potential ED – potential existing at the tip due to different electrolytes present in the pipet and the cell RA – resistance of connecting wire RB – resistance of wire connected to reference electrode RT – resistance of electrolyte filled

Depth & needle electrode: Depth electrode: Used to study the electrical activity of the neurons in superficial layers of the brain & also the oxygen tension Bundle of Teflon insulated platinum (90%) & Iridium (10%) alloy wires End of supporting wire is rounded Active area : 0.5 mm2

Depth electrode:

Needle electrode: Electroneurography Resembles medicine dropper or hypodermic needle Bend at one end and is inserted through the lumen and is advanced into the muscle Needle is withdrawn and the bent wire is resting inside the muscle

Needle electrode:

Surface electrodes: Larger area electrodes : ECG potentials Smaller area electrodes: EEG & EMG potentials Types: Metal plate electrodes Suction cup electrode Adhesive tape electrode Multipoint electrode Floating electrode

Metal plate electrodes: Rectangular (3.5 cm x 5 cm) & circular ( 4.75 diameter) in shape German silver, nickel silver, nickel plated steel ECG measurements

Suction Cup electrode: Flat surfaces of the body and to regions where the underlying tissue is soft Physically large but only rim (smaller area) is in contact to the skin

Adhesive tape electrode: The pressure of the surface electrode against the skin may squeeze the electrode paste out So, this type of electrodes are used Light metallic screen backed by a pad for electrode paste

Multipoint electrode: ECG measurement Nearly 1000 fine active contact points

Floating electrode: Metal does not contact the subject directly but via electrolytic bridge Also called as liquid junction electrode Movement artifact is eliminated

Distortion in signals: Ag-Agcl electrode uses shielded cable to reduce interference Johnson noise (random movement of charge carriers) or ohmic noise ( ohmic component of the electrode impedance) : micro electrodes Movement artifacts : equal half cell potential and high impedance will minimize the artifacts (floating electrodes) Distortion : movement of low current density

Chemical Electrodes: Hydrogen electrode Practical reference electrode Used to measure : Hydrogen electrode Practical reference electrode pH electrode pCO2 electrode pO2 electrode

Hydrogen electrode: Reference electrode (potential = 0) Used to measure pH of body fluids Platinum is electrolytically coated with finely divided platinum to increase the surface area This electrode with absorbed hydrogen is inserted into a catheter and is placed in pulmonary artery Monitored with a fluoroscope

Drawback of hydrogen electrode: Not sufficiently stable to serve as a reference electrode During measurement hydrogen gas should be supplied So, calomel & silver – silver chloride electrodes are used

Practical reference electrode: Ag-AgCl : smaller & stable half cell potential Ag-AgCl is kept at the central position and potassium chloride solution is filled around the electrode Calomel or mercurous chloride electrode is another popular reference electrode

pH electrode: pH = log10 1/[H+] = - log10 [H+] 7 → neutral solution <7 → acidic solution >7 → basic solution Human blood is slightly basic; venous blood : 7.35 & atrial :7.40

Contd..

pH electrode:

Contd.. Spherical bulb : 0.5 cm in diameter Permits the passage of only hydrogen ions in the form of H3O+ Inside the glass bulb silver-silver chloride non polarisable electrode is immersed in chloride buffer solution usually of pH = 1 Other side is glass bulb is exposed to the solution of unknown pH Adv: independent of oxidation – reduction potentials

pCO2 electrode: Standard glass pH electrode covered with rubber membrane permeable to CO2 Between the glass and membrane, water is there pH is measured and interpreted in terms of pCO2 on the basis of the linear relationship between log pCO2 and pH of the solution

pO2 electrode: Piece of platinum wire embedded in an insulating glass holder Other end is exposed to electrolyte where oxygen is allowed to diffuse through the membrane Ag-AgCl : reference electrode 0.7 V is applied between platinum(-ve) and reference electrode(+ve) Reduction takes place at the platinum wire

pO2 electrode: Clark electrode