Zoning Load Calculations

Slides:



Advertisements
Similar presentations
HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.
Advertisements

A Comparison of Measure Avoided Cost Calculations using Utility TOU Load Shapes and DEER Hourly Measure Savings 14 March 2006.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Heating, Ventilating, and Air-Conditioning
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Infiltration/Ventilation HVAC 7a CNST 305 Environmental Systems 1 Dr. Berryman.
Zoning Application. Copyright 2011 Trane 2 Zoning Application Agenda Application Overview --Benefits & Challenges with Zoning HVAC System Designs Conventional.
Airflow Properties & Measurement
System Sizing. Proper System Design Load Calculation Equipment Selection Duct Layout Branch runs Terminations Start ups Customer checks.
HEAT LOAD ESTIMATING USING THE SHORT COMPREHENSIVE METHOD © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
PTCS DUCT SEALING SPECIFICATIONS The Perfect Spec : Simple as possible Achievable by the motivated, not just the true believer Assure that energy savings.
Architecture. Importance of Orientation Placement of the home on the lot is just as important as the house. The house’s main length should face north.
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
General Troubleshooting Tips.
Important variables Water: Air: Conversion:
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
Heating Systems.
HVACR416 - Design Heat Loss / Heat Gain Part 2. External Loads The greatest external load is the sun. The suns heat can get into a building in one of.
Heat Migration in the Home 1 Energy Analysis and Comfort Solutions, Inc. Understanding Heat Migration in Your Home.
Some Pointers for your assignment..  Passive solar heating is defined as using solar energy incident on windows, skylights, greenhouses, clerestories,
15 Minute Leader Lesson Win it in a minute: Conserve resources with home energy management Managing home heat.
Duct Design Basics Lesson 4 Manual D Primer. Duct Sizing 4.3.
LOGO Heating Contractor HOW TO FIND THE RIGHT The Benefits The Questions Contact Information Goes Here Do you have a state license? How long have you been.
LOGO HOW TO FIND THE RIGHT A/C Contractor The Benefits The Questions Contact Information Goes Here Do you have a state license? How long have you been.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Maria’s Restaurant Chapter 2 Section 9
Part 16 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Maria’s Restaurant Chapter 2 Section 7
Maria’s Restaurant Appendix A Section 16 HVAC Building Loads
Maria’s Restaurant Chapter 1 Section 4
Maria’s Restaurant Chapter 1 Section 3
Maria’s Restaurant Chapter 3 Section 13
Maria’s Restaurant Chapter 4 Section 15
Lesson 24 Appendix F Outside Air Calculation
Maria’s Restaurant Chapter 1 Section 5
BUILDING HEATING AND COOLING
Maria’s Restaurant Chapter 2 Section 8
Conduction Cooling Loads
Section 1.0 — Fundamentals and General
Maria’s Restaurant Chapter 3 Section 12
Maria’s Restaurant Chapter 4 Section 14
High Performance HVAC Installation
Technician’s Guide and Workbook for Zoning Section 3: Single Zone Airflow Balancing and Thermostat Location.
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
Technician’s Guide and Workbook for Zoning Section 1: Introduction
Adding Zones to Existing Systems
Temperature and Comfort Complaints
The key to comfort and efficiency for heating and air-conditioning
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Zoning Methods There are an unlimited number of ways to zone a home! Popular ways include: More than one single zone HVAC system. Zone damper systems.
Mandatory Design Requirements
Excess Air Management Overview
Why we need to calculate heating load ?
Ceiling Convertible (ACC75~100D Series)
Lecture Objectives Learn about Cooling Load Calculation
Objective Revie the Cooling Cycle Learn about air distribution systems
Maria’s Restaurant Chapter 1 Section 3
Maria’s Restaurant Chapter 3 Section 12
Maria’s Restaurant Chapter 2 Section 7
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Chapter 2 Section 8
Lesson 24 Appendix F Outside Air Calculation
Maria’s Restaurant Chapter 1 Section 5
Ceiling Convertible (MCC075~100D Series)
Presentation transcript:

Technician’s Guide and Workbook for Zoning Section 4: Zoning Load Calculations

Zoning Load Calculations Load calculations need to be understood by field technicians before they can be successfully implemented. This section discusses how zones are selected and how they interact at different times of day.

Load Calculation Basics First step: a block load for equipment sizing is done so the equipment size can be determined. The equipment selected has expanded data on airflow that is used to determine main duct trunk sizes. Second step: a load is done for the air distribution components such as branch ducts, zone damper sizing, supply outlet sizing and local auxiliary equipment sizing.

Block Load Whole house as one large room.

Survey or Building Plan Review When a technician has access to the Manual J load calculation, it is a good practice to review it and make sure it is accurate. For example, if the attic insulation is missing, or if the direction the house is facing is wrong….there may be a problem that needs to be fixed before proceeding with an installation.

Air Distribution Component Based Load Duct system sizing used to convert CFM to load.

Survey or Duct Design Plan Review When a technician has access to the Duct Design calculation, it is a good practice to review it and make sure it is accurate. For example, make sure the CFM value is equal to or greater than the Manual J value for each room. Make sure all areas on the design are included in the construction plans and parts lists.

Airflow Design Numbers Airflow to individual rooms in a Manual J cooling load is rarely equal to airflow for a Manual J heating load. Further, the Manual D duct design is based on the larger of the two Manual J airflow values. To make things slightly more confusing for technicians, the final test and balance design airflow provided to the space is different than every airflow value that was covered previously.

Airflow Design Comparison

Totals From The Previous Table Cooling CFM (A total of 992 CFM when rooms are added together.). Heating CFM (A total of 880 CFM when rooms are added together.). Average CFM (A total of 936 CFM when rooms are added together.). Plus, using the larger of the cooling and heating for duct design would provide a total of 1017 CFM.

Understanding The Table Calculations XS H-CFM BC = Excess heating CFM when the system is balanced for cooling (in room 1) using the Manual J design values: [(116 ÷ 87) – 1] × 100 = 33.3%

Understanding The Table Calculations XS C-CFM BH = Excess cooling CFM when the system is balanced for heating (in room 1) using the Manual J design values: [ (87 ÷ 116) -1] × 100 = -25%

Understanding The Table Calculations XS C-CFM BH = Excess cooling CFM when the system is balanced for heating (in room 8) using the Manual J design values: [ (63 ÷ 75) -1] × 100 = -16%

Understanding The Table Calculations XS C-CFM BH = Excess heating CFM when the system is balanced for heating (in room 8) using the Manual J design values: [ (75 ÷ 63) -1] × 100 = 19%

Average Approach The average approach gets us closer to a design value that will offer reasonable comfort for heating and cooling. If the system is balanced for the excess value for heating becomes 16.7% of the design CFM, and for cooling it -12.5% or 12.5% low on airflow. Obviously, one could calculate an airflow value that was slightly lower and get an equal percentage for both values.

Field Balancing Applications In the field, the final CFM balancing values would be based on the measured blower CFM value. For example, based on the totaling of our heating and cooling CFM values: cooling calls for 992 CFM and heating calls for 880 CFM. If there is a two-speed blower setting that can come close to satisfying both, a technician would balance for either heating or cooling at the design speed and then double-check-and-make-sure the final airflows for both heating and cooling were within 20% of the balancing design for both modes of operation (heating and cooling / high speed and low speed).

Using Data For Thermostat Placement Based on the 8 room/zone values the rooms with the best C÷H ratio can be calculated: 116 ÷ 87 = 1.33 138 ÷ 111 = 1.24 119 ÷ 109 = 1.09 130 ÷ 108 = 1.20 113 ÷ 126 = 0.89 151 ÷ 128 = 1.18 162 ÷ 136 = 1.19 63 ÷ 75 = 0.84

Block Fenestration Load vs Hour Of the Day 30,000 25,000 20,000 15,000 10,000 5,000 1.3 × Average Block for Total Glass Average BTUH 9 10 11 12 13 14 15 16 17 18 19 Hour of the Day

Zone Fenestration Load vs Hour Of the Day 30,000 25,000 20,000 15,000 10,000 5,000 1.3 × Average Block for Total Glass Average Zone 1 (N & E) BTUH Zone 3 (W) Zone 2 (S) 9 10 11 12 13 14 15 16 17 18 19 Hour of the Day

Everyone Knows When The Sun Is Out

AED- Adequate Exposure Diversity

Calculations Using Manual D Area/zone 1 = 16,551 BTUH Area/zone 2 = 8,438 BTUH Area/zone 3 = 16,524 BTUH Total BTUH for room loads = 41,513 Total BTUH for Block Load = 32,759

Calculations Using Manual J Zone Branch Values Area/zone 1 = 19,036 BTUH Area/zone 2 = 11,684 BTUH Area/zone 3 = 19,560 BTUH Total BTUH for room loads = 50,280 Total BTUH for Block Load = 32,759

What Causes The Difference? Glass loads are the main cause of the difference between the two loads shown above. The block load is the sum of the three zone glass loads. For this home’s zones, the block load remains safely below 1.3 times the block average line for the whole day.

Glass Load Excursions 30,000 25,000 1.3 × Average 20,000 15,000 10,000 5,000 1.3 × Average Block for Total Glass Average BTUH Zone 1 (N & E) 1.3 × Average Zone 3 (W) Zone 2 (S) Average 9 10 11 12 13 14 15 16 17 18 19 Hour of the Day

Glass Load Excursions 30,000 25,000 20,000 15,000 10,000 5,000 Block for Total Glass Average Zone 3 (W) Zone 1 (N & E) Excursion BTUH 1.3 × Average Zone 2 (S) Average 9 10 11 12 13 14 15 16 17 18 19 Hour of the Day

Zoning by Exposure 4-5 PM 4-5 PM 4,500 4,000 West 1 3,500 East 1 3,000 2,500 2,000 1,500 1,000 500 West 1 East 1 West 2 BTUH West 3 East 2 9 10 11 12 13 14 15 16 17 18 19 Hour of the Day 4-5 PM

Field Notes The complaint is simple, this room gets warm in the afternoons in the summer and then, go figure, it gets too warm in the winter in the late afternoon. If the room has a lot of glass and faces south and/or west it could be the system design did not handle glass load excursions well. Based on the how warm it gets, adding a window film, or an overhang might resolve the problem. Ask an AC contractor and the answer will usually be an auxiliary unit or zoning. Ask a window contractor….