High Performance Liquid Chromatography

Slides:



Advertisements
Similar presentations
Gas Chromatography There an be many parts to a gas chromatography system but the basic components include: An injection system. A column (controllable.
Advertisements

Size Exclusion Chromatography
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
Chromatography CHEMISTRY Chromatography Chromatography is a technique for separating species based on physical or chemical properties. Usually.
Chromatography.
HPLC Systems. Column Chromatography HPLC Modes HPLC – System Components.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Chromatography and Instrumentation. Invented by a Russian Botanist Mikhail Tswett in 1903 He used chromatography to separate the colour pigments in plants.
Gas Liquid Chromatography
PRESENTED BY:- GAIKWAD OVESH & MD.NADEEM MANSOORI
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Pn. Suryati Bt. Syafri 2009 High Performance Liquid Chromatography (HPLC)
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
High Performance Liquid Chromatography High Performance Liquid Chromatography Chem. 331.
Analytical Chemistry Section D Separation Techniques.
Chapter 6 - Chromatography
High Performance Liquid Chromatography
Chromatography Separates components in mixture: Based on - polarity
Chromatography Chapter 6.
Magnet Analytical Chemistry Unit 4
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
High Performance Liquid Chromatography Instrumentation.
1. Fast Protein Liquid Chromatography 2 FPLC A semi-automatic microprocessor controlled machine used primarily for the separation of macromolecules A.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Analytical Separations
High Performance Liquid Chromatography High Performance Liquid Chromatography Presented by- MOHSIN NISAR KHAN MOHSIN NISAR KHAN.
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
HPLC – High Performance Liquid Chromatography
Introduction  High-performance liquid chromatography (HPLC) is a form of liquid chromatography.liquid chromatography  The main purpose is to separate.
1 HPLC Lecture Displacement pumps Displacement pumps, on the other hand, is composed of a one directional motor driven plunger that pushes the mobile.
Best Broken into four categories
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
HPLC.
High Performance Liquid Chromatography
Chapter 28 High Performance Liquid Chromatography.
HPLC.
Introduction to Instrumental Analysis - Chromatography
Ashraf M. Mahmoud, Associate professor CHROMATOGRAPHYCHROMATOGRAPHY.
Principles of chromatography
 Laboratory technique for the Separation of mixtures  Chroma -"color" and graphein - "to write”.  Colour bands - separation of individual compounds.
HPLC (High Performance Liquid Chromatography)
Experiments in Analytical Chemistry
THIN LAYER CHROMATOGRAPHY.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
Bioseparation II Chromatography Techniques. Chromatography Most widely used purification technique used for biomolecules. Most widely used purification.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Chromatography 1 Lecture 10 An introduction. What is CHROMATOGRAPHY ? Chromato g raphy.
LU 3: Separation Technique (P2)
Chem. 133 – 5/11 Lecture.
CHROMATOGRAPHY.
HPLC.
High Performance Liquid Chromatography (HPLC)
Size Exclusion Chromatography (SEC)
Chromatographic separation
Best Broken into four categories
HPLC.
Chapter: Chromatography
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Chromatography Daheeya Alenazi.
High Performance Liquid Chromatography
Principle of separation of different components:
Chapter: Chromatography
High Performance Liquid Chromatography (H. P. L. C. ) dr. Sham b
Liquid Chromatography - Method Development and Validation
High-Performance Liquid Chromatography
GAS CHROMATOGRAPHY.
High performance liquid chromatography (HPLC)
High-Performance Liquid Chromatography
Presentation transcript:

High Performance Liquid Chromatography Chem. 331

Introduction HPLC is a form of liquid chromatography used to separate compounds that are dissolved in solution. HPLC instruments consist of a reservoir of mobile phase, a pump, an injector, a separation column, and a detector. Compounds are separated by injecting a sample mixture onto the column. The different component in the mixture pass through the column at differentiates due to differences in their partition behavior between the mobile phase and the stationary phase. The mobile phase must be degassed to eliminate the formation of air bubbles.

HPLC system

FOUR TYPES OF LIQUID CHROMATOGRAPHY Partition chromatography Adsorption, or liquid-solid chromatography Ion exchange chromatography Size exclusion, or gel, chromatography

COMPOSITION OF A LIQUID CHROMATOGRAPH SYSTEM Solvent Solvent Delivery System (Pump) Injector Sample Column Detectors (Diode Array) Waste Collector Recorder (Data Collection)

Picture of HPLC instrument

Uses of HPLC This technique is used for chemistry and biochemistry research analyzing complex mixtures, purifying chemical compounds, developing processes for synthesizing chemical compounds, isolating natural products, or predicting physical properties. It is also used in quality control to ensure the purity of raw materials, to control and improve process yields, to quantify assays of final products, or to evaluate product stability and monitor degradation. In addition, it is used for analyzing air and water pollutants, for monitoring materials that may jeopardize occupational safety or health, and for monitoring pesticide levels in the environment. Federal and state regulatory agencies use HPLC to survey food and drug products, for identifying confiscated narcotics or to check for adherence to label claims.

HPLC Chromatograph injectors The function of the injector is to place the sample into the high-pressure flow in as narrow volume as possible so that the sample enters the column as a homogeneous, low-volume plug. To minimize spreading of the injected volume during transport to the column, the shortest possible length of tubing should be used from the injector to the column. When an injection is started, an air actuator rotates the valve: solvent goes directly to the column; and the injector needle is connected to the syringe. The air pressure lifts the needle and the vial is moved into position beneath the needle. Then, the needle is lowered to the vial.

HPLC columns The column is one of the most important components of the HPLC chromatograph because the separation of the sample components is achieved when those components pass through the column. The High performance liquid chromatography apparatus is made out of stainless steel tubes with a diameter of 3 to 5mm and a length ranging from 10 to 30cm. Normally, columns are filled with silica gel because its particle shape, surface properties, and pore structure help to get a good separation. Silica is wetted by nearly every potential mobile phase, is inert to most compounds and has a high surface activity which can be modified easily with water and other agents. Silica can be used to separate a wide variety of chemical compounds, and its chromatographic behavior is generally predictable and reproducible.

Picture of an HPLC column

WHAT AFFECTS SYSTEM Column Parameters Instrument Parameters Column Material Deactivation Stationary Phase Coating Material Instrument Parameters Temperature Flow Signal Sample Sensitivity Detector

WHAT AFFECTS SYSTEM Sample Parameters Concentration Matrix Solvent Effect Sample Effect

Several column types (can be classified as ) Normal phase Reverse phase Size exclusion Ion exchange

Normal phase In this column type, the retention is governed by the interaction of the polar parts of the stationary phase and solute. For retention to occur in normal phase, the packing must be more polar than the mobile phase with respect to the sample

Reverse phase In this column the packing material is relatively nonpolar and the solvent is polar with respect to the sample. Retention is the result of the interaction of the nonpolar components of the solutes and the nonpolar stationary phase. Typical stationary phases are nonpolar hydrocarbons, waxy liquids, or bonded hydrocarbons (such as C18, C8, etc.) and the solvents are polar aqueous-organic mixtures such as methanol-water or acetonitrile-water.

Size exclusion In size exclusion the HPLC column is consisted of substances which have controlled pore sizes and is able to be filtered in an ordinarily phase according to its molecular size. Small molecules penetrate into the pores within the packing while larger molecules only partially penetrate the pores. The large molecules elute before the smaller molecules.

Ion exchange In this column type the sample components are separated based upon attractive ionic forces between molecules carrying charged groups of opposite charge to those charges on the stationary phase. Separations are made between a polar mobile liquid, usually water containing salts or small amounts of alcohols, and a stationary phase containing either acidic or basic fixed sites.

Selectivity Factor K’ values tell us where bands elute relative to the void volume. These values are unaffected by such variables as flow rate and column dimensions. The value tell us where two peaks elute relative to each other. This is referred to as the selectivity factor or separation factor (now and then as the chemistry factor).

Types of Liquid Column Chromatography (LCC) LLC (Liquid Liquid) LSC (Liquid Solid - adsorption) SEC (Size Exclusion) GLC GSC SFC (Supercritical Fluid)

Types of Detectors Absorbance (UV with Filters, UV with Monochromators) IR Absorbance Fluorescence Refractive-Index Evaporative Light Scattering Detector (ELSD) Electrochemical Mass-Spectrometric Photo-Diode Array

EVALUATION PARAMETERS EFFICIENCY RESOLUTION INERTNESS RETENTION INDEX COLUMN BLEED CAPACITY FACTOR

References http://192.215.107.101/ebn/942/tech/techfocus/1071main.html http://www.chem.usu.edu/~sbialk/Classes/565/opamps/opamps.html Skoog, Holler, and Neiman. Principles of Instrumental Analysis. 5th ed. Orlando: Harcourt Brace & Co., 1998. http://weather.nmsu.edu http://elchem.kaist.ac.kr/vt/chem-ed/sep/lc/hplc.htm http://www.chemistry.nmsu.edu/Instrumentation/Lqd_Chroma.html http://weather.nmsu.edu/Teaching_Material/SOIL698/Student_Material/HPLCHP1090/HPLCINJ.HTM http://test-equipment.globalspec.com/LearnMore/Labware_Scientific_Instruments/Analytical_Instruments/Chromatographs/HPLC_Columns http://www.chemistry.adelaide.edu.au/external/soc-rel/content/lc-col.htm