Comparing the Matrix and EPID Flatness/Symmetry/Output Measurement

Slides:



Advertisements
Similar presentations
Chapter 16 Inferential Statistics
Advertisements

Beam Therapy Equipment 2 Linear Accelerator Head.
5/3/2015J-PARC1 Transverse Matching Using Transverse Profiles and Longitudinal Beam arrival Times.
Mathematics and Graphing in Chemistry Lab 1. Outline Mathematics in Chemistry Units Rounding Digits of Precision (Addition and Subtraction) Significant.
IMAGE QUALITY NOISE LINEARITY CROSS-FIELD UNIFORMITY IMAGE ARTIFACTS.
Evaluation of the characteristics of TLD LiF:Mg.Ti-100 Powder: A Measure of Consistency Between Multiple Batches of Powder Paola Alvarez,Jose Francisco.
Laboratory Quality Control
Process Improvement Dr. Ron Tibben-Lembke. Statistics.
Lotte Verbunt Investigation of leaf positioning accuracy of two types of Siemens MLCs making use of an EPID.
Speckle Reduction in Ultrasound Image Prepared by: Osama O. AbuSalah & Almoutaz Alhumaid Osama O. AbuSalah & Almoutaz Alhumaid Supervised by: Dr. Ali Saad.
Data Handling l Classification of Errors v Systematic v Random.
At the position d max of maximum energy loss of radiation, the number of secondary ionizations products peaks which in turn maximizes the dose at that.
Forecasting Revenue: An Example of Regression Model Building Setting: Possibly a large set of predictor variables used to predict future quarterly revenues.
…….CT Physics - Continued V.G.WimalasenaPrincipal School of radiography.
Unit #7 - Basic Quality Control for the Clinical Laboratory
Evaluating Performance for Data Mining Techniques
Quality Assessment 2 Quality Control.
Научно-практический центр протонной лучевой терапии и радиохирургии (Москва-Дубна) A SYSTEM FOR MEASUREMENT OF A THERAPEUTIC PROTON BEAM DOSE DISTRIBUTION.
Chapter 36 Quality Engineering Part 2 (Review) EIN 3390 Manufacturing Processes Summer A, 2012.
Graphical Summary of Data Distribution Statistical View Point Histograms Skewness Kurtosis Other Descriptive Summary Measures Source:
Forecasting Revenue: An Example of Regression Model Building Setting: Possibly a large set of predictor variables used to predict future quarterly revenues.
Blue: Histogram of normalised deviation from “true” value; Red: Gaussian fit to histogram Presented at ESA Hyperspectral Workshop 2010, March 16-19, Frascati,
W  eν The W->eν analysis is a phi uniformity calibration, and only yields relative calibration constants. This means that all of the α’s in a given eta.
Measurement Uncertainties Physics 161 University Physics Lab I Fall 2007.
Chapter 21 R(x) Algorithm a) Anomaly Detection b) Matched Filter.
Laboratory QA/QC An Overview.
LOGO ภาควิชาอิเล็กทรอนิกส์ คณะวิศวกรรมศาสตร์ สถาบันเทคโนโลยีพระจอมเกล้าเจ้าคุณทหารลาดกระบัง.
Chapter 36 Quality Engineering (Part 2) EIN 3390 Manufacturing Processes Summer A, 2012.
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
FREQUANCY DISTRIBUTION 8, 24, 18, 5, 6, 12, 4, 3, 3, 2, 3, 23, 9, 18, 16, 1, 2, 3, 5, 11, 13, 15, 9, 11, 11, 7, 10, 6, 5, 16, 20, 4, 3, 3, 3, 10, 3, 2,
Xoft Routine Per Article Manufacturing Testing of the Axxent ® Source S. Axelrod, T.W. Rusch, M. Powell; Xoft, Inc., Fremont, CA  Purpose: To select sources.
An Overview. Definitions (1)  Quality Control - QC refers to the measures that must be included during each assay run to verify that the test is working.
Fiducial Cuts for the CLAS E5 Data Set K. Greenholt (G.P. Gilfoyle) Department of Physics University of Richmond, Virginia Goal: To generate electron fiducial.
Spatial Smoothing and Multiple Comparisons Correction for Dummies Alexa Morcom, Matthew Brett Acknowledgements.
Observing Transfer Functions For Multimode Spectrometers.
Abhilash Nair STAR Collaboration University of Illinois at Chicago 1 STAR.
1 SMU EMIS 7364 NTU TO-570-N Control Charts Basic Concepts and Mathematical Basis Updated: 3/2/04 Statistical Quality Control Dr. Jerrell T. Stracener,
ERT 207 Analytical Chemistry ERT 207 ANALYTICAL CHEMISTRY Dr. Saleha Shamsudin.
Machine Vision Edge Detection Techniques ENT 273 Lecture 6 Hema C.R.
Update on Diffractive Dijets Hardeep Bansil University of Birmingham 12/07/2013.
MBF1413 | Quantitative Methods Prepared by Dr Khairul Anuar 8: Time Series Analysis & Forecasting – Part 1
Measurement Technique A technique was developed for measuring the radioactive concentration of breast milk samples for Tc-99m labelled radiopharmaceuticals.
The Effects of Small Field Dosimetry on the Biological Models Used In Evaluating IMRT Dose Distributions Gene Cardarelli,PhD, MPH.
Adapting A Clinical Medical Accelerator For Primary Standard Dosimetry
36.3 Inspection to Control Quality
Lab1 A VISIBLE ABSORPTION SPECTROMETER
Unit #6 - Basic Quality Control for the Clinical Laboratory
Novel Techniques for the Position Calibration of FAUST
FiDeL: the model to predict the magnetic state of the LHC
Beam Gas Vertex – Beam monitor
COS FUV Flat Fields and Signal-to-Noise Characteristics
PCB 3043L - General Ecology Data Analysis.
Linac Commissioning Overview
Laboratory Quality Control
Lecture 4(Unit II): Gas-Filled Detector Quality Control
Honors Statistics Chapter 4 Part 2
Choice of Methods and Instruments
MBF1413 | Quantitative Methods Prepared by Dr Khairul Anuar
NanoBPM Status and Multibunch Mark Slater, Cambridge University
Ch 10. A System of Dosimetric Calculations
Residuals and Residual Plots
Quality Control Quality control is a process that is used to ensure a certain level of quality in a product or service. Most often, it involves thoroughly.
Project HW 6 (Due 3/4) points You are given the following dataset to analyze using TDA Mapper a.) What do you expect the output of TDA mapper to.
Introduction To Medical Technology
Quality Control Lecture 3
Xbar Chart By Farrokh Alemi Ph.D
16. Mean Square Estimation
CISE-301: Numerical Methods Topic 1: Introduction to Numerical Methods and Taylor Series Lectures 1-4: KFUPM CISE301_Topic1.
IR/MDI requirements for the EIC
Clinical instrumental analysis
Presentation transcript:

Comparing the Matrix and EPID Flatness/Symmetry/Output Measurement Raymond Hoang, Elaine Conneely Introduction Method (continued) Discussion As for the output given by the flatness and symmetry measurement, it is important to determine the use of things. To keep consistency, the Elekta system (also known as IEC 60976:2007) of measuring flatness and symmetry is used. To complicate things, the open field image is actually 2 images, where the 1st image measures from y = -20cm to 0, and the 2nd image measures from y = 0 to 20 cm. As a result, the image looks misshaped: To compensate, measuring from the y axis required “stitching” the two images together. A Gaussian filter was then applied, then a sample line (5 pixels wide, and both traverse and longitudinal) is drawn, averaged out, and had the Savitzky–Golay filter applied. This is repeated for the other image. The entire image is then linearly regressed with the matrix measurements. There is one factor that may effect the reading on the output measurement, and that is the measurement. For one, there could be some form of long term deterioration in either the EPID panel, or the matrix device. This could result in But until more information on the rate of EPID panel and matrix panel deterioration, it will be difficult to determine whether the EPID panel will be an acceptable substitute The largest problem when it came to the symmetry measurement was that there was not enough variation in the symmetry, to the point where the day to day changes in the measurement of symmetry could be caused by the measurement error. In delivering patient dose, it is important to know that the beam shape, and the output will remain consistent over time. To ensure this, QA is done on the machine. However, this requires the use of a 2D ion chamber array matrix (or matrix device), particularly when it comes to flatness and symmetry measurements. As a result, it is only limited to be used monthly. In this project, the use of EPID panel to compare flatness, symmetry and output. Method When measuring output, one has to compare the dose measurements from both the matrix device and the EPID panel. To do this, a region of interest is drawn over the center of the beam in this manner. This is to reduce variations in the beam shifting in the EPID panel, while minimizing the chances that a single region of interest will span multiple detector blocks. It’s then averaged out. A few other corrections needed includes having to correct for large changes, including any seasonal changes that was observed in the matrix device. Next Steps Further analysis on the decay of matrix device is ideal, to rule out the decay of the matrix device as the cause of the lack of correlation between the two output measurements. Also, the symmetry calculation should be further improved to improve the correlation factor. Results ACKNOWLEDGEMENTS The results showed that there is only a moderate correlation in symmetry measurements in the flatness measurements between the matrix device and the EPID Panel it ranged from 0.45 to 0.71. For example, on one of the machines, the r^2 value was 0.65: However, the output and symmetry measurements are not correlated at all: I cannot thank enough the entire team at Acumyn for helping with this project, especially when it comes to getting information. Special thanks to Dr. Daniel Letourneau and Dr. Elaine Conneely for supervising the project. REFERENCES [1] Medical electrical equipment - Medical electron accelerators - Functional performance characteristics IEC 60976:2007 Accessed February 26, 2018 https://webstore.iec.ch/publication/408 Raymond Hoang (hoang117@uwindsor.ca) Program: Physics Co-op Co-op Work Term: Winter2018 Employer: Acumyn Supervisor: Dr. Elaine Conneely Figure 1. Plot of the output measured by the matrix device. The blue line represents the data before the correction in the change of output, while the yellow line represents the final corrected output. The red line is a sine curve fitted to the blue line.